0% found this document useful (0 votes)
47 views4 pages

Electrical Layout

The document provides a legend and schedules for an electrical wiring plan. The legend defines various electrical components using abbreviations. The conduit and cable schedules specify the sizes of piping and wiring to be used. PVC pipes of 3/4" and 1" diameter are to be used for different applications. Cable sizes of 1.5 mm2, 2.5 mm2 and 4 mm2 are specified for lighting, power, and air conditioning circuits respectively.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views4 pages

Electrical Layout

The document provides a legend and schedules for an electrical wiring plan. The legend defines various electrical components using abbreviations. The conduit and cable schedules specify the sizes of piping and wiring to be used. PVC pipes of 3/4" and 1" diameter are to be used for different applications. Cable sizes of 1.5 mm2, 2.5 mm2 and 4 mm2 are specified for lighting, power, and air conditioning circuits respectively.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

LEGEND:

EM ENERGY METER
MDB MAIN DISTRIBUTION BOARD
EC_MDB EMERGENCY COMMON MAIN DISTRIBUTION BOARD
EMDB EMERGENCY DISTRIBUTION BOARD
FDB FLOOR DISTRIBUTION BOARD.
SB SWITCH BOARD
CL CEILING LIGHT
EL ENERGY LIGHT
TL TUBE LIGHT
SL SECURITY LIGHT
CB CALLING BELL
BP BELL PUSH
GL GATE LIGHT
DN DOWN CONDUCTOR FOR EARTHING
PS 16/20 A PUSH BUTTON SWITCH FOR WATER PUMP.
Q 15/16A, 3 PIN SWITCHED SOCKET OUTLET FOR AC BELOW CEILING
P 15/16A, 3 PIN SWITCHED SOCKET OUTLET 300 MM FROM FFL
G 15/16A, 3 PIN SWITCHED SOCKET OUTLET FOR GEYSER ABOVE FALSE CEILING
R 15/16A, 3 PIN SWITCHED SOCKET AT MAN HEIGHT LEVEL.
S 5/10A, 2 PIN SWITCHED SOCKET AT SWITCH BOARD LEVEL.
EF ESHAUST FAN
C.O.S CHANGE OVER SWITCH
TMDF TELEPHONE MAIN DISTRIBUTION FRAME
TJB TELEPHONE JUNCTION BOX
DCMJB DISH CABLE MAIN JUNCTION BOX
ICMJB INTERCOM MAIN JUNCTION BOX
T TELEPHONE OUTLET
TV TV ANTENNA SOCKET OUTLET
AC AIR CONDITIONER
I/C INTERCOM OUTLET

CH CHANDELIER

CF CEILING FAN
IN INTERNET
H KITCHEN HOOD

CONDUIT PIPE SCHEDULE:

PVC PIPE ELECTRIC GRADE 3/4"(FM SWITCH BOARD TO EACH LOAD).


PVC PIPE ELECTRIC GRADE 1"(FM FDB TO SWITCH BOARD AND FDB INCOMING).
PVC PIPE ELECTRIC GRADE 3/4".
PVC PIPE ELECTRIC GRADE 3/4".

CABLE SCHEDULE:
1.5 mm2 BYA CABLE TO BE USED FOR POINT WIRING.
1.5 mm2 BYA CABLE TO BE USED FOR LIGHT & FAN CIRCUIT.
2.5 mm2 BYA CABLE TO BE USED FOR POWER CIRCUIT.
4 mm2 BYA CABLE TO BE USED FOR AC & GEAGER CIRCUIT.
TOILET KITCHEN BED-04
(4'-11"X6'-2") (6'-0"X8'-0")
12'-0"X11'-5"
7'-2" x 3'-0"
Veranda

BED-02
12'-0"X10'-2"
UP
Collapsible Gate

Veranda
10090807060504030201 TOILET
(7'-0'' X 8'-0'')

(7'-6"X4'-0") 4'-0" x 4'-0"

29'-0"
+2'-6"
±0'-0"
EGL

PL
DRAWING/DINING
11'-4"X19'-9"
7'-2" x 3'-0"
Veranda
BED-01 BED-03
12'-0"X10'-2" 12'-0"X11'-10"
37'-0"
GROUND FLOOR PLAN
N
S
Exh.Fan
P
S
B
FD
_

P
SB
EC

CL
P
CL
CF=56" CF=56"

B
FD
_
EC
P
P SB
P

SB
EC-MDB MDB
Collapsible Gate
(7'-0'' X 8'-0'')

29'-2"
CL
CL CL

SB
CF=56"
±0'-0"
EGL

FDB

SB
P
EC
_F
DB

SB
S

P
CL

B
FD

P
_

SB
EC
TV CF=56"
IN
CF=56" CF=56"
P P
37'-0"
GROUND FLOOR PLAN
N
S
Exh.Fan
P
3'-10"

3'-10"
S
B
FD
_

P
SB
EC

CL
6'-0" 6'-5"
P
CL
CF=56" CF=56"

B
_FD
EC
P
P SB

4'-10"
P

SB
EC-MDB MDB
Collapsible Gate
(7'-0'' X 8'-0'')

5'-6"

29'-2"
CL
CL CL

SB
CF=56"
±0'-0"
EGL

FDB

SB
P
EC
_F
DB

SB
S

P
CL
CF=56" 5'-6" CF=56"

B
FD

P
_
6'-0" 5'-6"

SB
EC
TV CF=56"
IN

5'-4"
3'-10"

5'-4"
P P
37'-0"
GROUND FLOOR PLAN