Spotcheck SKL-SP2, SKL-WP2, SK-3 Kit - Product Data Sheet - Nov 14 - English

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Product data sheet

spotcheck SKL-SP2
SKL-WP2
SK-3 kit
red penetrants

Penetrant Description Composition Benefits


A blend of petroleum distillates,
SKL-SP2 Solvent-removable (post-emulsifiable) plasticiser and an oil-soluble Broad range of applications.
organic red dye.

A blend of petroleum distillates, Excellent controlled washability


SKL-WP2 Water-washable and solvent-removable non-ionic surfactants and an over a wide temperature range and
oil-soluble organic red dye. variable dwell times.
The SK-3 Kit is a portable visible penetrant inspection kit that includes the following:
SK-3
Penetrant • 2 x 400 ml aerosol cans of SKL-SP2 penetrant • 1 cloth
Inspection • 3 x 400 ml aerosol cans of SKC-S cleaner • 1 set of instructions
Kit
• 3 x 400 ml aerosol cans of SKD-S2 developer • 1 portable carrying case

General Description
Our Spotcheck red colour-contrast penetrants offer maximum reliability in locating surface-open flaws and defects. They exhibit
outstanding penetrating characteristics, producing vivid red indications of flaws which can easily be seen with the naked eye.

Applications
Our red penetrants are used throughout industry wherever a visible penetrant inspection system is suitable for detecting surface
defects. Typical applications include castings, forgings, leak testing, welds and general metal work.

The penetrants can also be used on non-porous ceramics and similar materials. However, we do not recommended them for
inspecting plastic materials, as they may stain, soften or even dissolve the base material under test.

Typical Properties (not a specification)


Property SKL-SP2 SKL-WP2
Colour Dark red Dark red
Flash point > 93oC (bulk product) > 93oC (bulk product)
Density 0.85 g/cm 3
0.88 g/cm3
Viscosity 3.8 mm2/s 8.0 mm2/s
Sulphur content < 300 ppm < 300 ppm
Chloride content < 300 ppm < 300 ppm
Corrosion Meets AMS 2644 Meets AMS 2644
AMS 2644 class Type 2 Method B, C, D Type 2 Method A, C
Storage temperature 10oC - 50oC 10oC - 50oC
Usage temperature Bulk: 2 °C - 65 °C. Aerosol: < 50 C
o

Coverage One aerosol covers approx. 12 -16 m2. One litre covers approx. 30 - 40 m2.
Product data sheet

spotcheck skl-sp2, skl-wp2, sk-3 kit


General Method of Use

SKL-SP2

Solvent wipe method Hydrophilic method

Apply penetrant SKL-SP2 to the clean component Apply penetrant SKL-SP2 to the clean component
and allow contact time. and allow contact time.

Spray component with water to


remove excess penetrant.
Wipe off excess penetrant with a cloth dampened
with cleaner/remover SKC-S.

Immerse component in hydrophilic remover


ZR-10C for the predetermined time.

Dry component, apply developer


(SKD-S2 or ZP-5B) and inspect.
Spray component with water to
remove last traces of penetrant.

Dry component, apply developer


(SKD-S2 or ZP-5B) and inspect.

SKL-WP2

Pre-clean component with cleaner SKC-S.

Apply penetrant SKL-WP2 to the clean component


and allow contact time.

Use SKC-S or spray the component with water to


remove excess penetrant.

Dry component, apply developer


(SKD-S2 or ZP-5B) and inspect.
Product data sheet

spotcheck skl-sp2, skl-wp2, sk-3 kit

General Method of Use Recommended Products


Ensure test part is clean and dry, and free from oil, Product type Product Name(s) Type
grease and other contaminants.
Cleaner/remover SKC-S Solvent-based
Emulsifier ZR-10C Hydrophilic
Apply penetrant by immersion dip, brush, flow on, conven-
tional or electrostatic spray. Cover the test area completely. SKD-S2 Solvent-based
Developer
ZP-5B Water-based
Allow a minimum penetration time of 2 - 5 minutes. 10
minutes should be adequate for most situations, however,
lower temperatures will thicken the penetrant and require a
Specification Compliance
longer penetration time. Specification SKL-SP2 SKL-WP2
AMS2644F  
Remove excess penetrant ASME B & PV Code, Sec V  
• SKL-SP2: use a solvent wipe or by the hydrophilic ASTM D129  
remover method (see previous page).
ASTM E165/E165M  
• SKL-WP2: spray the component with clean water at ASTM E1417/E1417M  
10°C - 40°C, or wipe with a lint-free cloth dampened with
EN ISO 3452-1  
our SKC-S cleaner.
EN ISO 3452-2
(Sensitivity Level 2)  
Once clean, dry the component should before applying a
MIL-STD-2132D  
developer.
MIL-STD-271F  
Apply a thin layer of developer to the surface and allow a
minimum of 10 minutes development time before inspecting
the component under white light. Indications will appear Availability
dark red against the white developer background. SKL-SP2 SKL-WP2
Unit Part numbers (if applicable)
A developer is used to maximise sensitivity and provide a 10 x 400ml aerosol 008A016 008A163
white contrasting background. There are two types: 4 x 5 litre pack 005C076 055C071
• Solvent-based: quick-drying materials which you apply 25 litre container N/A 055C072
by spraying.
The SK-3 Kit is available as follows:
• Water-based (aqueous): apply by dipping or spraying.
• Complete SK-3 Kit - part number 008A038
To ensure penetrant sensitivity, parts should only be
• Carrying case only - part number 053C009
exposed to aqueous developers for short periods of time.

Developer residue can be removed either by wiping with a


cloth or by a water and detergent wash. Penetrant residues
Health and Safety
can be removed by vapour degreasing or solvent soak. Read the relevant Safety Data Sheets for the individual
products before use. Safety Data Sheets are available on
request from your Magnaflux distributor or via the
Magnaflux website:
www.eu.magnaflux.com

Faraday Road, South Dorcan Industrial Estate, Swindon, Wiltshire, SN3 5HE, UK T + 44 (0)1793 524566 E [email protected]
Bahnhofstr 94-98, 73457 Essingen, Germany T +49 (0) 7365 81-0 E [email protected]
P.O. Box 530, 651 12 Karlstad, Sweden T +46 54 29 39 50 E [email protected]
Version 14.1