Review On IOT Based Transmission Line Fault Detection
Review On IOT Based Transmission Line Fault Detection
https://doi.org/10.22214/ijraset.2023.50719
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue IV Apr 2023- Available at www.ijraset.com
Abstract: The electrical system is made up of numerous unique parts. One of these is the transmission system, which involves
sending electricity from substations and substations to consumers along power lines. This paper provides a review of the
research being done for Internet of Things-based transmission line fault detection.
I. INTRODUCTION
A. About Transmission Line Faults
Transmission lines are used to move electricity from generating units to distant load centres. Faults may develop on these gearbox
lines as a result of lightning, incorrect operation, overload, short circuits, human error, malfunctioning equipment, and ageing. When
a defect develops, the voltage of the affected phase drops, and large currents flow that, if not stopped right once, might burn out the
components. The faults in transmission lines powered by a three-phase power source are, in decreasing order of frequency of
occurrence:
1) Single-phase-to-ground faults (L-G): Single Line-to-Ground Faults (SLG) are the most prevalent form of fault. One conductor
touching the ground or making contact with the neutral wire will result in this kind of fault. It might also be the result of trees
collapsing during a rainstorm.
2) Phase-to-phase faults (L-L): The Line-to-Line fault (LL) is the second most frequent form of fault. Two transmission lines are
said to short-circuit when this happens. For example, if a huge bird were to perch on one transmission wire while touching
another, or if a tree branch were to fall on top of two electricity transmission lines..
3) Double-phase-to-ground faults (L-L-G): The Double Line-to-Ground fault (DLG) in the graphic below represents the third type
of fault. This might be due to a tree falling on two power lines, among other things.
4) Three-phase fault (3-ф): Balanced three phases, which can result from a contact between the three power lines in a variety of
ways, are the fourth and most serious type of fault. This calls for very quick diagnosis and correction of transmission network
faults. A high performance data communication network that meets future operational requirements like real-time monitoring
and control required for smart grid integration must also be installed in order to sustain the outdated transmission line
infrastructure.
B. What is IOT?
The internet of things, or IOT, is a network that connects smart devices that use embedded systems, like processors, sensors, and
communication hardware, to gather, and act on data they gather from their environments. The idea behind IOT is to connect any
device with an ON/OFF switch to the internet and then provide the necessary output.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 2554
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue IV Apr 2023- Available at www.ijraset.com
The users can choose the most precise approach with ease. Because two end methods are less sensitive to faults than one end
methods, they are stronger than one end methods. [1]
This study found that reliable fault detection and classification are essential for effective power distribution to various sites. The
precise protection of transmission lines is ensured by active circuit breaker tripping, and the tripping action of circuit breakers is
dependent on the current and voltage waveforms during the fault. The usage of Discrete Wavelet Transform (DWT) for study of
current waveforms during fault is highlighted. For the purpose of identifying and categorising defects on a transmission line
network, discrete wavelet analysis was evaluated. Classification of flaws had been done based on energy level percentage. [1]
It is discussed how to employ wireless sensors to detect faults in power lines, such as phase-to-phase, short-circuit, and primarily
line-to-ground faults, for more dependable and effective system functioning. In this concept, the power line is separated into WNS
(wireless sensor network) nodes that may detect the power line's fault condition, show it to the operator, and send an SMS to the
service engineer via a GSM modem. This concept effectively and thoroughly investigates the asymmetrical faults that develop in
power lines. The PIC 16F877A microcontroller, which is attached to the current sensor in a Wireless Sensor Network (WNS),
transforms the analogue measured current value into digital form and then communicates the data to the primary first node via
transceiver. principles determined by a PIC 16F877A microcontroller are transmitted GSM technology is used to transmit data to a
control panel or substation so that quick action can be taken.. [2]
The system examined a variety of defect kinds for monitoring purposes. The limit for each error can be set by the NodeMCU when
it is communicated to a web page via a Wi-Fi module. The system notifies the authority's cell phone if any parameter exceeds its
limit. By contrasting the calculated values obtained from a theoretical equation with the actual measured findings, the overhead
transmission line monitoring system is evaluated. In order to increase the system's viability and utility, it might also collaborate with
an IoT system. The Wi-Fi module transmits and receives data from the numerous sensors, which are then saved in a database. The
power company could be informed companies to increase transmission line safety or act as a resource in the power dispatch centre.
Every bit of information from overhead broadcast is recorded hour by hour. Every time a gearbox line issue arises, it takes time and
costs substantially more to fix it. Additionally, there is a risk to life. Here, the application of IOT to transmission lines will aid in
enhancing transmission line maintenance and monitoring. A quick fix shortens the time it takes to find the problem in the field and
brings the system back up. For real-time monitoring, the system can be tested outdoors. The main energy expense is accounted for
by IOT services on scattered placed devices. Combining different services is one approach to reduce energy costs. minimise the
bandwidth usage on a device to conserve computation and communication power. Therefore, it is crucial, economical, and efficient
to use IOT for transmission line monitoring.. [3]
In the study titled IOT based fault monitoring system, a cost-optimized framework for designing a real-time data transmission
network is described. Sensors are installed in a number of the power network's components to track the power system's status in real
time. These sensors produce a lot of data and are able to take precise measurements of a wide range of electrical or physical
properties. Building an intelligent smart grid requires addressing the fundamental challenge of promptly and cost-effectively
delivering this information to the control centre. A key component of sensor-based transmission line monitoring is network design
because of the massive scale, extensive topography, unusual topology, and crucial timing requirements. mechanical issues, cost
savings brought by by the extensive scale, broad geography, unusual topography, and pressing schedule needs. mechanical issues,
cost savings from condition-based maintenance as opposed to routine maintenance, etc. Applications like analysing mechanical
status and dynamic transmission line ratings make use of sensor networks. Sensors are installed in a number of the power network's
components to track the power system's status in real time. With the intention of installing cellular transceivers on each tower, the
hierarchical model proposes an extremely expensive option. Although such a network can deliver incredibly low latency data
transmission, the significant installation and subscription expenses make this concept very inefficient.. [4]
To ensure safety, reduce equipment damage, and preserve power system stability, the primary purpose of the protection system is to
quickly clear faults from the power system. Understanding system faults, their identification, and safe isolation of the defective
equipment are necessary for the protection of power systems. A basic electrical load evaluation and an inventory of all the necessary
electrical loads can give an indication of how much power the system must generate. Situations involving power fluctuation, such as
the maximum/minimum voltage obtained from the a.c. supply mains, are also taken into account. [5]
This paper explains the GSM-based fault detection approach. An accurate location of the fault occurring in the transmission line
(latitude and longitude) will be sent via GPS coupled to a GSM-based fault detection system. The system can be correctly
programmed to determine the distance between the fault and the substation. When the threshold is bridged, the GSM modem is used
to transmit and receive the fault and position.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 2555
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue IV Apr 2023- Available at www.ijraset.com
The sensing unit includes the sensors for sensing current, voltage, frequency, and temperature in order to help gather electrical
parameters and make the corresponding signals available for the PIC to process. This system's benefit is that it provides precise
details regarding the type of line fault that occurred, such as L, G, L, etc. The system asserts that it is more adaptable than the
current conventional system. [6]
III. CONCLUSION
Compared to the conventional method of fault detection in transmission lines, IoT-based transmission line fault detection offers a
quicker and more efficient solution. In any season, the fault may be accurately located, as well as its position. A number of issues
can be addressed by wireless sensor-based monitoring of transmission lines, but the effectiveness of these applications depends on
the creation of cost-effective, dependable, and responsive network architecture.
REFERENCES
[1] Mr.Nilesh, S.Wani, Dr. R. P. Singh, “TRANSMISSION LINE FAULTS DETECTION”, Volume 7, Issue 2, March-April, 2016. +
[2] S.Leelakrishnan, V.Ganesharavinth, K.Kalpana, P.Sivaranjani, S.Vijaykumar. ‘DISTRIBUTION SIDE FAULT DETECTION AND DISCONNECTION
USING GSM. Vol. 6, Issue 3, March 2017.
[3] Mayur Apotikar, Vishal Chandak, Santosh Daberao, Shoeb Shah. IOT BASED TRANSMISSION LINE MONITORING SYSTEM. Volume 2, Issue2, April
2022. DOI: 10.48175/IJARSCT-3349
[4] R Navaneetha Krishna, Niranjan L, N Shyamsundar, Dr. C Venkatesan. ‘IOT BASED TRANSMISSION LINE FAULT MONITORING SYSTEM’ IJRAR
August 2020, Volume 7, Issue 3.
[5] MD Asaduzzaman Nur, Jahidul Islam, Md. Golam Mostofa & Moshiul Alam Chowdhury, ‘TRANSMISSION LINE FAULT DETECTION USING ANDROID
APPLICATION VIA BLUETOOTH’, Volume 14 Issue 8 Version 1.0 Year 2014.
[6] Rahul Kumar, Ashish Thapa. FAULT DETECTION IN TRANSMISSION LINES USING GSM TECHNOLOGY. April 2019, Volume 6, Issue 4.
www.jetir.org
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 2556