Pag. 1 of 2
The spacer dampers must be installed in a position perpendicular to the THE SPACER DAMPERS MUST BE INSTALLED WITHIN 24
axis of sub-conductors, as shown in the figure below. Any deviation from HOURS FROM THE STRINGING OPERATIONS
this condition, in vertical and horizontal sense, must not be more than 3°. INSTALLATION MUST BE MADE USING A BUCKET TRUCK OR
BY PLACING PERSONNEL ON THE CONDUCTORS THROUGH
CORRECT INSTALLATION WRONG INSTALLATION !!
THE USE OF A CONDUCTOR CAR.
FOR A CORRECT AND EASIER INSTALLATION, THE WEIGHT
OF LINEMAN, CONDUCTOR CAR AND EQUIPMENT MUST BE
EQUALLY DISTRIBUTED TO ALL SUB-CONDUCTORS OF THE
PHASE.
THE LOCATION ALONG THE CONDUCTORS MUST BE IN
ACCORDANCE WITH THE RECOMMENDED POSITIONING
TABLE OF THE PROJECT.
THE CORRECT LOCATION MUST BE DETECTED BY MEANS
OF GROUND TARGETS OR CAR DISTANCE COUNTERS.
CHECK WITH ATTENTION THE CORRECT CLOSURE OF ALL
SPACER DAMPER CLAMPS.
THE PROPER INSTALLATION AND TIGHTENING OF THE
SPACER DAMPER IS SHOWN ON THE FOLLOWING PAGE.
3/15
IITRSD
Rev.02 IIPT-MO-966-ANG19-02085
Pag. 2 of 2
1 2
Unscrew the clamp bolt
until the end of the bolt is
on level with the external
edge of the captive nut.
Do not unscrew the bolt
completely, to avoid
loosing it and its washers. Place the clamp body
If you loose the bolt and/or correctly on the
washers, replace them conductor.
with DAMP spare parts.
Do not replace with
similar ones.
The clamp is designed to
allow installation on the
conductor without removing
the bolt.
3 4
4/15
IIPT-MO-966-ANG19-02085
IMPORTANT NOTES
DAMP's system of in-span positioning shown in the following tables, has been computerized.
DAMP's computer programme is based on many correlated field test results, and analytical studies
concerning the behaviour of all currently employed, bundled conductors.
The in-span positionings tabulated are applicable to currently employed (twin, triple, quad,
hexagonal) conductor bundles in spans with standard dimensions and structural characteristics.
For special conditions, such as, extra long spans, wide river or ravine crossings, at high ground
clearance etc., employing high breaking load conductors at high tensions, a specific study/control
is essential to verify (or modify) the system in relation to the specific and special conditions.
In particular, for twin conductor bundles and/or All Aluminium Alloy conductors, the use of
additional Stockbridge type vibration dampers is necessary in almost all cases.
5/15
IITRSD
Rev.02 IIPT-MO-966-ANG19-02085
Pag. 1 of 2
The spacer dampers must be installed in a position perpendicular to the THE SPACER DAMPERS MUST BE INSTALLED WITHIN 24
axis of sub-conductors, as shown in the figure below. Any deviation from HOURS FROM THE STRINGING OPERATIONS
this condition, in vertical and horizontal sense, must not be more than 3°. INSTALLATION MUST BE MADE USING A BUCKET TRUCK OR
BY PLACING PERSONNEL ON THE CONDUCTORS THROUGH
CORRECT INSTALLATION WRONG INSTALLATION !!
THE USE OF A CONDUCTOR CAR.
FOR A CORRECT AND EASIER INSTALLATION, THE WEIGHT
OF LINEMAN, CONDUCTOR CAR AND EQUIPMENT MUST BE
EQUALLY DISTRIBUTED TO ALL SUB-CONDUCTORS OF THE
PHASE.
THE LOCATION ALONG THE CONDUCTORS MUST BE IN
ACCORDANCE WITH THE RECOMMENDED POSITIONING
TABLE OF THE PROJECT.
THE CORRECT LOCATION MUST BE DETECTED BY MEANS
OF GROUND TARGETS OR CAR DISTANCE COUNTERS.
CHECK WITH ATTENTION THE CORRECT CLOSURE OF ALL
SPACER DAMPER CLAMPS.
THE PROPER INSTALLATION AND TIGHTENING OF THE
SPACER DAMPER IS SHOWN ON THE FOLLOWING PAGE.
6/15
IITRSD
Rev.02 IIPT-MO-966-ANG19-02085
Pag. 2 of 2
1 2
Unscrew the clamp bolt
until the end of the bolt is
on level with the external
edge of the captive nut.
Do not unscrew the bolt
completely, to avoid
loosing it and its washers. Place the clamp body
If you loose the bolt and/or correctly on the
washers, replace them conductor.
with DAMP spare parts.
Do not replace with
similar ones.
The clamp is designed to
allow installation on the
conductor without removing
the bolt.
3 4
7/15
IIPT-MO-966-ANG19-02085
Table DR-7035_08
QUANTITY OF SPACER
Rev. 02
DAMPERS PER SPAN PHASE
Date Januay. 2015
8/15
IIPT-MO-966-ANG19-02085
Note 1: The spacer damper shall be located at min. 2 meters away from
any mid span joint, repair sleeve or any other fitting attachment to the
conductor.
9/15
IIPT-MO-966-ANG19-02085
Reference: DR-7035_08
10/15
IIPT-MO-966-ANG19-02085
Reference: DR-7035_08
11/15
IIPT-MO-966-ANG19-02085
Reference: DR-7035_08
SPACERS N° 8 SPACERS N° 9
LENGTH (m) LENGTH (m)
Span Sub-Span Span Sub-Span
454 30 61 55 48 57 62 55 61 25 517 30 63 54 60 50 56 64 53 62 25
455 30 61 55 49 57 62 55 61 25 518 30 63 54 60 51 56 64 53 62 25
456 30 61 55 49 57 63 55 61 25 519 30 63 54 60 51 56 64 54 62 25
457 30 62 55 49 57 63 55 61 25 520 30 63 54 61 51 56 64 54 62 25
458 30 62 55 49 57 63 55 62 25
459 30 63 55 49 57 63 55 62 25 521 30 63 54 61 51 57 64 54 62 25
460 30 63 55 49 58 63 55 62 25 522 30 63 54 61 51 57 65 54 62 25
523 30 63 55 61 51 57 65 54 62 25
461 30 63 55 49 58 64 55 62 25 524 30 64 55 61 51 57 65 54 62 25
462 30 63 55 50 58 64 55 62 25 525 30 64 55 61 51 57 65 55 62 25
463 30 63 56 50 58 64 55 62 25 526 30 64 55 61 52 57 65 55 62 25
464 30 63 56 50 58 64 56 62 25 527 30 64 55 62 52 57 65 55 62 25
465 30 63 57 50 58 64 56 62 25 528 30 64 55 62 52 57 65 55 63 25
466 30 63 57 50 59 64 56 62 25 529 30 64 55 62 52 58 65 55 63 25
467 30 64 57 50 59 64 56 62 25 530 30 64 55 63 52 58 65 55 63 25
468 30 64 57 50 59 64 57 62 25
469 30 64 57 51 59 64 57 62 25 531 30 64 56 63 52 58 65 55 63 25
470 30 64 57 51 59 64 57 63 25 532 30 64 56 63 52 58 65 55 64 25
533 30 64 56 63 52 58 65 56 64 25
471 30 64 57 51 59 65 57 63 25 534 30 64 56 63 52 59 65 56 64 25
472 31 64 57 51 59 65 57 63 25 535 30 64 56 63 52 59 65 56 64 26
473 31 64 58 51 59 65 57 63 25 536 30 65 56 63 52 59 65 56 64 26
474 31 64 58 51 59 65 57 64 25 537 30 65 56 63 53 59 65 56 64 26
475 31 64 58 51 59 66 57 64 25 538 30 65 56 63 53 59 66 56 64 26
476 31 64 58 51 60 66 57 64 25 539 31 65 56 63 53 59 66 56 64 26
477 31 64 58 51 60 66 57 64 26 540 31 65 56 63 53 59 66 57 64 26
478 31 64 58 52 60 66 57 64 26
479 31 64 58 52 60 66 58 64 26 541 31 65 56 63 53 60 66 57 64 26
480 31 65 58 52 60 66 58 64 26 542 31 65 56 64 53 60 66 57 64 26
543 31 65 56 64 53 60 66 57 64 27
481 31 65 59 52 60 66 58 64 26 544 32 65 56 64 53 60 66 57 64 27
482 31 65 59 53 60 66 58 64 26 545 32 66 56 64 53 60 66 57 64 27
483 32 65 59 53 60 66 58 64 26 546 32 66 56 64 53 60 67 57 64 27
484 32 65 59 53 60 66 59 64 26 547 32 66 57 64 53 60 67 57 64 27
485 32 65 59 53 60 67 59 64 26 548 32 66 57 64 53 60 67 57 65 27
486 32 65 59 53 60 67 59 64 27 549 32 66 57 64 54 60 67 57 65 27
487 32 65 59 53 60 67 59 65 27 550 32 66 57 64 54 61 67 57 65 27
488 32 65 59 53 61 67 59 65 27
489 32 66 59 53 61 67 59 65 27 551 32 66 57 64 54 61 67 58 65 27
490 32 66 59 53 62 67 59 65 27 552 32 66 58 64 54 61 67 58 65 27
553 32 66 58 64 54 61 67 58 65 28
491 32 66 59 53 62 67 60 65 27 554 32 67 58 64 54 61 67 58 65 28
492 32 66 59 53 62 67 60 66 27 555 32 67 58 65 54 61 67 58 65 28
493 32 66 59 54 62 67 60 66 27 556 33 67 58 65 54 61 67 58 65 28
494 32 66 59 54 62 68 60 66 27 557 33 67 58 65 54 61 68 58 65 28
495 32 66 59 54 62 68 60 66 28 558 33 67 58 65 55 61 68 58 65 28
496 33 66 59 54 62 68 60 66 28 559 33 67 58 65 55 61 68 58 66 28
497 33 66 60 54 62 68 60 66 28 560 33 67 58 65 55 61 68 59 66 28
498 33 67 60 54 62 68 60 66 28
499 33 67 60 54 62 68 60 66 29 561 33 68 58 65 55 61 68 59 66 28
500 33 68 60 54 62 68 60 66 29 562 33 68 58 65 56 61 68 59 66 28
563 33 68 58 65 56 61 68 59 66 29
501 33 68 60 54 62 69 60 66 29 564 33 68 58 65 56 62 68 59 66 29
502 33 68 60 54 62 69 61 66 29 565 33 68 58 65 56 62 68 59 67 29
503 33 68 61 54 62 69 61 66 29 566 33 68 58 66 56 62 68 59 67 29
504 33 68 61 54 62 69 61 67 29 567 34 68 58 66 56 62 68 59 67 29
505 33 68 61 54 63 69 61 67 29 568 34 68 58 66 56 62 69 59 67 29
506 33 68 61 55 63 69 61 67 29 569 34 68 59 66 56 62 69 59 67 29
507 34 68 61 55 63 69 61 67 29 570 34 68 59 66 57 62 69 59 67 29
508 34 68 61 55 63 69 62 67 29
509 34 69 61 55 63 69 62 67 29 571 34 69 59 66 57 62 69 59 67 29
510 34 69 61 55 63 69 62 67 30 572 34 69 59 67 57 62 69 59 67 29
573 34 69 59 67 57 62 69 59 67 30
511 34 69 61 56 63 69 62 67 30 574 34 69 59 67 57 63 69 59 67 30
512 34 69 61 56 63 70 62 67 30 575 34 69 60 67 57 63 69 59 67 30
513 35 69 61 56 63 70 62 67 30 576 34 69 60 67 57 63 69 59 68 30
514 35 69 62 56 63 70 62 67 30 577 34 69 60 67 57 63 70 59 68 30
515 35 69 62 56 64 70 62 67 30 578 35 69 60 67 57 63 70 59 68 30
516 35 69 62 56 64 70 62 68 30 579 35 69 60 67 57 63 70 60 68 30
12/15
IIPT-MO-966-ANG19-02085
Reference: DR-7035_08
SPACERS N° 10
LENGTH (m)
Span Sub-Span
580 30 63 58 51 59 53 62 56 65 58 25
581 30 63 58 51 59 53 63 56 65 58 25
582 30 63 58 52 59 53 63 56 65 58 25
583 30 63 58 52 60 53 63 56 65 58 25
584 30 64 58 52 60 53 63 56 65 58 25
585 30 64 58 52 60 54 63 56 65 58 25
586 30 64 58 52 60 54 63 56 65 59 25
587 30 64 59 52 60 54 63 56 65 59 25
588 30 64 59 52 60 54 64 56 65 59 25
589 30 64 59 52 60 55 64 56 65 59 25
590 30 64 59 52 60 55 64 56 65 59 26
591 30 64 59 52 60 55 64 56 65 60 26
592 30 65 59 52 60 55 64 56 65 60 26
593 30 65 59 53 60 55 64 56 65 60 26
594 30 65 59 53 61 55 64 56 65 60 26
595 30 65 59 53 61 55 64 56 66 60 26
596 30 65 59 53 61 55 64 57 66 60 26
597 31 65 59 53 61 55 64 57 66 60 26
598 31 65 59 53 61 55 64 57 66 60 27
599 31 65 59 53 61 55 65 57 66 60 27
600 31 66 59 53 61 55 65 57 66 60 27
601 31 66 59 54 61 55 65 57 66 60 27
602 31 66 59 54 61 56 65 57 66 60 27
603 31 66 59 54 61 56 65 58 66 60 27
604 32 66 59 54 61 56 65 58 66 60 27
605 32 66 60 54 61 56 65 58 66 60 27
606 32 66 60 54 62 56 65 58 66 60 27
607 32 66 60 54 62 56 65 58 67 60 27
608 32 66 60 54 62 56 65 58 67 61 27
609 32 66 60 54 62 57 65 58 67 61 27
610 32 66 61 54 62 57 65 58 67 61 27
611 32 67 61 54 62 57 65 58 67 61 27
612 32 67 61 54 62 57 66 58 67 61 27
613 33 67 61 54 62 57 66 58 67 61 27
614 33 67 61 54 63 57 66 58 67 61 27
615 33 67 61 54 63 57 66 58 67 61 28
616 33 67 61 54 63 57 66 59 67 61 28
617 33 67 61 54 63 57 66 59 68 61 28
618 33 67 61 55 63 57 66 59 68 61 28
619 33 67 61 55 63 57 66 59 68 62 28
620 33 67 61 55 63 57 67 59 68 62 28
621 33 68 61 55 63 57 67 59 68 62 28
622 33 68 61 55 63 58 67 59 68 62 28
623 33 68 61 55 63 58 67 59 68 62 29
624 33 68 61 55 63 58 67 60 68 62 29
625 33 68 61 55 63 58 67 60 69 62 29
626 34 68 61 55 63 58 67 60 69 62 29
627 34 68 62 55 63 58 67 60 69 62 29
628 34 68 62 56 63 58 67 60 69 62 29
629 34 68 62 56 64 58 67 60 69 62 29
630 34 68 62 56 64 58 67 60 69 63 29
631 34 68 63 56 64 58 67 60 69 63 29
632 34 68 63 56 64 58 68 60 69 63 29
633 34 68 63 57 64 58 68 60 69 63 29
634 34 68 63 57 64 58 68 61 69 63 29
635 34 69 63 57 64 58 68 61 69 63 29
636 34 69 63 57 65 58 68 61 69 63 29
637 34 69 63 57 65 58 68 61 70 63 29
638 35 69 63 57 65 58 68 61 70 63 29
639 35 69 63 57 65 58 68 61 70 64 29
640 35 69 63 57 65 59 68 61 70 64 29
641 35 69 63 57 65 59 68 61 70 64 30
13/15
IIPT-MO-966-ANG19-02085
VIBRATION DAMPER
MOSDORFER TYPE 9313.006/G/1 - DRAWING N. F1001276
IMPORTANT NOTES
THE VIBRATION DAMPERS MUST BE INSTALLED WITHIN 24 HOURS FROM
SUBCONDUCTORS ADJUSTMENT AND CLAMPING.
14/15
IIPT-MO-966-ANG19-02085
ONE DAMPER X
TWO DAMPERS
X
X
FOUR DAMPERS
X
SIX DAMPERS
NOTES
a – The positioning criteria is applied for span suspension - suspension, suspension -
tension, tension - tension
b – One damper per span: for span suspension – tension place the damper close to the
suspension
c – Smaller damper counterweight tower side (suggested)
15/15