0% found this document useful (0 votes)
410 views7 pages

Manual Olympus

The VISERA Video System is a versatile endoscopy system that offers high-quality imaging solutions. It includes a wide range of autoclavable videoscopes and camera heads that can be connected to a single video system center. The system allows for digital recording of still and moving images. It provides seamless control of endoscopy needs with sophistication and efficiency.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
410 views7 pages

Manual Olympus

The VISERA Video System is a versatile endoscopy system that offers high-quality imaging solutions. It includes a wide range of autoclavable videoscopes and camera heads that can be connected to a single video system center. The system allows for digital recording of still and moving images. It provides seamless control of endoscopy needs with sophistication and efficiency.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

VISERA VIDEO SYSTEM

GENERAL
SURGERY

Vision of the Next Generation

VISERA VIDEO SYSTEM

Printed in Japan R315UB-1105


Superior Lineup

Vision of the Next Generation Dynamic, High-Quality Imaging Solutions


Versatility and Quality
a Level Beyond ● You demand a wide selection of scopes for
any situation, plus the ability to connect
● Videoscopes, plus several high-quality camera heads.
all scopes to a single system.
● Autoclavability, including videoscopes and camera heads.
● Digital recording for both still and moving images. Videoscopes
OTV-S7V
VISERA Video System Center
With a full line of autoclavable surgical videoscopes and camera
heads, digital documentation of still/moving images, and much Fiberscope
Camera Head + or
more. Take control of your imaging needs with the sophistication Telescope
and seamless efficiency of VISERA.
The VISERA Digital Imaging Platform responding to every need
● You demand autoclavable instruments.
in minimally invasive surgery...and to your every demand.
● You demand remote control of functions.

High-Performance
Digital Documentation

Digital Gives You More Control

● You demand digital recording of both still and


moving images for smarter management of
Multi-Interface recorded images.

An extensive lineup for your needs. Adding functions later is also possible.
DV Unit PC Card Unit P in P Unit Orientation Unit
Type B Upgrade for Your Needs!
Type C PC Card P in P Multi- Orientation
Basic DV Unit Unit Unit Freeze Unit
Type D Unit

Type F

Office or
Multi-Specialty Standardized
Operating
Compatibility Control VISERA is also compatible with the EndoALPHA
Room
Olympus Integrated Endosurgery System.
When used with the EndoALPHA Olympus Integrated
VISERA Concept Endosurgery System, VISERA camera functions can be
VISERA allows the interconnection of a variety of videoscopes and camera heads. controlled via voice navigation and touch control, thus
It lets you share equipment and standardize control, enhancing the service, efficiency, greatly improving efficiencies in your operating room.
and affordability of endoscopy in your hospital.

PC Card DV Output
2 3
Superior Lineup
V ideoscopes
Dynamic, High-Quality
LTF TYPE VP/V3 VISERA Laparo-Thoraco Videoscope
Imaging Solutions
The VISERA lineup includes videoscopes with superb image
LTF TYPE VP Superb Image Quality from a Simultaneous- ● Wider Depth of Field and Tip Angulation
Multicolor CCD and Angulation in 4 Directions. in Four Directions
quality, from a simultaneous-multicolor CCD on their distal
The LTF TYPE VP/V3 features a compact The LTF TYPE VP/V3 has a wider depth of field for finer observation
tips. There are also a variety of camera heads, including control section for easy one-handed use. of organs. The tip's angulation range makes it possible to view forceps
The shorter bending section allows smoother from directly above, letting you cut tissues more smoothly.
autoclavable ones, allowing you to choose whichever most
LTF TYPE V3 orientation, even in narrow cavities. LTF-VP/ V3
suits your needs.
Forceps

In Abdominal Cavity On-Monitor Image


A500**A

A500**A VISERA Laparo-Thoraco Videoscope (Autoclavable)


High-Resolution True-Life Images with ● Image Rotation for Thorough Orientation
a Simultaneous-Multicolor CCD. You can rotate the scope using a knob for thorough orientation.
ø5.4mm and ø10mm sizes are
available, each with 0º and 30º
ENDOEYE is the brand name of the LTF TYPE VP/V3 and
direction of view. Those with
A500**A VISERA Laparo-Thoraco Videoscopes.
30º views also allow image-
rotation for thorough orientation.

A Variety of
Camera Heads Autoclavable Camera Heads
Three types of autoclavable camera heads are available: Normal, Quick and Cost-Effective Autoclave Sterilization
Eyepiece-Integrated, and Quick-Lock Integrated, letting you
Lets You Keep Up with Higher Numbers of Surgeries.
choose the one that best suits your needs.
It only takes approx. 10 to 60 minutes to autoclave,
so you don't have to worry about higher numbers of surgeries.
Autoclaving is also cost-effective and known for its safety.

Non-autoclave equipment allows With autoclavable equipment, two surgeries


only one surgery per day (one in the a.m., another in the p.m.)
are possible.
Focus Free Camera Heads (Autoclavable) A.M. P.M. A.M. P.M.
The Focus Free function lets you Monday Monday
concentrate on your procedures Tuesday Tuesday
without taking time out to adjust Wednesday Wednesday
the focus.

Convenient Remote Control


OTV-S7V/CLV-S40
with LCD Monitor Electronic Zoom P in P, Rotated, or Mirrored Image Display*
Remote control switches are built into the control sections of You can remote-control You can enlarge an image to 1.2x, 1.5x, or 2x. You can display another image (such as ultrasonic, CT, or MRI)
the videoscopes and camera heads. Frequently used functions can be functions such as simultaneously with the endoscopic image and switch between
programmed, letting you control them without looking away from them using the main and sub-display. Rotated or mirrored image
what you're doing. ● VTR Recording/Pause display lets another doctor view images from the same angle.
● Zoom
● Capture * Available with Type C.
(on SmartMedia* via a PC card adapter)
● P in P, Rotated/
Mirrored Image Display
● Automatic White Balance
Normal 1.5x
* SmartMedia is a trademark of TOSHIBA Corporation. Normal Rotated Mirrored

4 5
Digital Documentation

Digital Gives You


More Control
VISERA lets you record images using remote control switches.
Once recorded digitally, both still and moving images can be
quickly sorted and easily edited.

SmartMedia*

● Conferences
xD-Picture Card

Record Still Images

Digital Data
in Various Formats

Store Directly to Extensive Application ● Meetings


PC Hard-Disks
Digitally Recorded Images Make Editing Easy
for Conferences, Meetings, and More
Editing moving images is easy, letting you use
image data in a variety of ways.

Record Moving Images


● Quick Search Using a Server
● Quick Transmission Using a LAN (Local Area Network)

Smooth Recording
Still/Moving Image Recording with Smart Storage and
Remote Control Switches
Volume Ratio
Only 8%
Management
of VHS
Compact and Convenient
Both still and moving images can be stored as
VHS tape DV tape compact digital data. A server and network
* SmartMedia is a trademark of TOSHIBA Corporation. Digital Videotapes via IEEE
● Space-Saving Digital Videotape make managing them hassle-free.
6 7
System Chart
OTV-S7V
VISERA Video System Center
AR-TL12S (Compatible with EndoALPHA)
MH-999S Video Adapter OTV-S7H-N/1N/1D
Rigid Endoscope Video Coupler (Screw) Camera Head

Eyepiece
AR-T10S/T12S, Type B
SmartMedia * xD-Picture Card

AR-T10SA/T12SA
MH-999E Video Adapter OTV-S7H-NA-10E/12E
Video Coupler (Eyepiece)
OTV-S7H-1NA-10E/12E
Autoclavable Camera Head
AR-T10/T12 Type C
Rigid Endoscope MH-999Q Video Adapter
Video Coupler
(Quick-Lock)
PC Card Adapter
OTV-S7H-NA-10Q/12Q
AR-TZ2 for xD-Picture Card/SmartMedia
OTV-S7H-1NA-12Q
Video Adapter Autoclavable Camera Head Type D
AR-T10Q/T12Q,
A3298 AR-T10QA/12QA
Light Guide Cable Video Adapter

Light Guide Cable OTV-S7H-NA/1NA


Camera Head Type F
MAJ-1173
AR-TF08E/TL08E S6 Camera Head
Video Adapter Connecting Unit
For S7V

Fiberscope OTV-S7H-FA/1FA-E
Autoclavable Focus Free Camera Head
AR-T10E/T12E, AR-T10EA/12EA OEV191H/191
Video Adapter LCD Monitor
OTV-S6
OES VIDEO SYSTEM
MAJ-944
OTV-S7H-FA-Q Light Control Cable
LTF-VP/V3 Autoclavable Focus Free Camera Head
Deflectable-Tip Video Laparoscope
MAJ-1345
Lens Cleaning Sheath For LTF-V3

MAJ-1124
Note: The Olympus VISERA Video System can be configured for cardiac applications only when Type CF Keyboard For OTV-S7
applied parts (camera heads and light guide cables) bearing the symbol are used. MAJ-1200
OTV-S7H-1D-F08E/L08E CLV-S40 Universal Light MAJ-1324
Camera Head Xenon Light Source Guide Adapter P Converter
A500**A
Rigid Videoscope
* SmartMedia is a trademark of TOSHIBA Corporation.

VISERA Lineup
Video System Center ■ Specifications (When all B.O.D. units are installed in the OTV-S7V)
Power Supply Voltage 100 - 240 V AC *1 Observation Patient Data Input Patient data can be entered.
VISERA VIDEO SYSTEM CENTER Voltage Fluctuation Within ±10% Menu Patient Data Display Patient data display is set to ON/OFF.
Frequency 50/60 Hz Shutter Shutter is set to ON/OFF.

OTV-S7V Frequency Fluctuation


Electric Power Consumption
Within ±1 Hz
70 VA
PC Card Frozen image can be recorded to or played back from
SmartMedia.
Fuse Rating 3.15 A, 250 V Picture In Picture *2
The external image from the video input terminal can be
Select the type that meets your needs. Fuse Size ø5 x 20 mm shown on the same video monitor as the main or sub image.
You can add functions later to your selection. Size Dimensions 295 (W) x 80 (H) x 370 (D) mm Reverse Image Mirrored or rotated (180°) images can be displayed on
Weight Type B: 6.5 kg Type C: 6.6 kg Type D: 6.3 kg Type F: 6.6 kg the video monitor.
Classification Type Of Protection Against Electric Shock Class I Multi-Freeze Multi-freeze image can be displayed on the video monitor.
Degree Of Protection Against Electric Shock Depends on the applied part. Preset The OTV-S7V's setting can be saved or loaded for 7 users.
Degree Of Protection The VISERA Video System Center (OTV-S7V) should Clock Time and date can be adjusted.
Against Explosion be kept away from flammable gases. Remote Control The OTV-S7V's functions can be operated by remote
Observation Television System NTSC / PAL Switch Setting control switches on the camera head or videoscope.
Video Signal Output VBS (1.0 Vp-p 75 Ω): 1 Color Mode Setting Color mode is selected from among 5 modes.
Y/C (Y:1.0 Vp-p 75 Ω, C: 0.28 Vp-p 75 Ω): 3 Red Color Adjustment ±8 levels
RGB (R.G.B.: 1.0 Vp-p 75 Ω, SYNC: 4.0 Vp-p 75 Ω): 1 Blue Color Adjustment ±8 levels
DV (IEEE1394 Digital Video Output Signal): 1 Color Bar Output Full-field color bar
Video Signal Input VBS (2.0 Vp-p): 1 Recording VTR Remote Control Remote control of VTR recording possible by connecting
Auto White Balance Automatically adjusted with the white balance switch. the optional MAJ-438 remote control cable.
Brightness Light Source Light reflected from the subject is measured by the SCV-3 Remote Control Remote control of EVIS monitor photo unit (SCV-3: not
B.O.D. B.O.D. Indicator Type B Type C Type D Type F Adjustment Intensity camera head or videoscope in combination with the available in some countries) possible by connecting the
DV Unit For OTV-S7 (OTV-S7BOD-DV) DV/DVC PRO Adjustment specified Olympus light sources. optional MH-986 remote cable.
PC Card Unit For OTV-S7 (OTV-S7BOD-PC) DIGITAL CAPTURE Exposure Level The exposure level switch adjusts brightness ±8 levels. OEP/OEP-3 Remote control of color video printer (OEP/OEP-3) possible
Observation Focus Free Focus free is possible only when a camera head with a Remote Control by connecting the optional MH-987 remote cable.
P in P Unit For OTV-S7 (OTV-S7BOD-PP) P IN P/REVERSE
Menu built-in focus free function is connected. DV Remote Control Remote control of DV recording possible by connecting
Orientation Unit for OTV-S7 (OTV-S7BOD-RT) ORIENTATION Image Enhancement An imaging process which electrically intensifies the the optional IEEE1394 cable.
boundary of an image. Memory Card SmartMedia (128/64/32/16/8MB) and xD-Picture Card
AGC The image can be electrically amplified when the light is inadequate (512/256/128/64/32/16 MB) are specified by Olympus.
because the distal end of the endoscope is too far from the subject. MA-2E and MAPC-10 can be used as PC card adapter.
Iris Exposure area can be selected. *2 Input signals of the P in P display are limited to composite video signals (NTSC standard ).
Freeze Image can be frozen by the video monitor. The P in P display is limited to signals in conformity to RS-170A color video signals (15.734 kHz horizontal and 59.94 Hz vertical).
Black-and-white video signals in conformity to RS-170 (15.75 kHz horizontal and 60 Hz vertical) are not acceptable due to the
*1 When using an NTSC model with a voltage over 120 V AC, use a power cord specific to the voltage. impossibility of synchronizing.
8 9
Camera Head Videoscope
CAMERA HEAD OTV-S7H-N/1N OTV-S7H-1D VISERA LAPARO-THORACO VIDEOSCOPE

OTV-S7H-N OTV-S7H-1N
w/built-in moiré-filter
OTV-S7H-1D
w/built-in moiré-filter
LTF TYPE VP/V3
■ Specifications A high-resolution videoscope capable of angulation in 4 directions.
Camera Head Dimensions ø27 x 37 mm (from mount surface)
Weight 40 g (excluding cable) ■ Specifications
Cable ø5.2 mm x 4 m Model LTF TYPE VP LTF TYPE V3
Number of remote control switches: 2
Cleaning/Disinfection Immersible in disinfectant solution with a video adapter attached. Optical System Field Of View 80° 90°
Sterilization Ethylene oxide gas sterilization possible.
Direction Of View 0° (forward viewing)
Depth Of Field 18 - 100 mm 15 - 100 mm
CAMERA HEAD Insertion Portion Distal End Outer Diameter ø5.4 mm ø10 mm
Rigid Portion Outer Diameter ø5.3 mm ø10 mm
OTV-S7H-1D-F08E OTV-S7H-1D-L08E
Eye-piece type, w/finder, w/built-in moiré-filter Eye-piece type, w/built-in moiré-filter Bending Section
Working Length
Angulation Range
370 mm
Up 100°, Down 100°,
330 mm
Up 100°, Down 100°,
Right 100°, Left 100° Right 60°, Left 60°
■ Specifications Total Length 3600 mm
Number of remote control switches: 3
Camera Head Dimensions Endoscopic mount: ø45.2 x 12.1 mm
Finder block: 25W x 17.7H x 17.2D mm
Camera head: ø14 x 45 mm VISERA LAPARO-THORACO VIDEOSCOPE
Weight 45 g (excluding cable)
Cable
Cleaning/Disinfection
ø3.3 x 4 m
Immersible in disinfectant solution. A50001A /A50003A /A50021A /A50023A
Sterilization Ethylene oxide gas sterilization possible.
High-resolution videoscopes with image rotation*.
AUTOCLAVABLE CAMERA HEAD * With 30°-view models.
OTV-S7H-NA OTV-S7H-1NA
w/built-in moiré-filter
■ Specifications
Model A50001A A50003A Model
Number of remote control switches: 3
A50021A A50023A
Display Full Screen Display Full Screen
■ Specifications
Television System NTSC Television System NTSC
Camera Head Dimensions ø29 x 85 mm (from mount surface)
Picture Elements 410,000 Picture Elements 270,000
Weight 125 g (excluding cable)
Direction Of View 0° 30° Direction Of View 0° 30°
Cable ø6.8 mm x 4 m
Number of remote control switches: 2 Field Of View 70° Field Of View 70°
Cleaning/Disinfection Immersible in disinfectant solution with a video adapter attached.
Depth Of Field 20 to 100 mm Depth Of Field 15 to 100 mm
Sterilization Ethylene oxide gas sterilization and steam (autoclave) sterilization possible.
Outer Diameter 10 mm Outer Diameter 5.4 mm
Working Length 300 mm Working Length 300 mm
AUTOCLAVABLE CAMERA HEAD Image Rotation Function Image Rotation Function

OTV-S7H-NA-10E OTV-S7H-1NA-10E
Dedicated Autoclave Tray 595 (L) x 295 (W) x 61 (H) mm Dedicated Autoclave Tray 595 (L) x 295 (W) x 61 (H) mm

1.0x, Eye-piece type 1.0x, Eye-piece type, w/built-in moiré-filter


Light Source
OTV-S7H-NA-12E OTV-S7H-1NA-12E
1.2x, Eye-piece type 1.2x, Eye-piece type, w/built-in moiré-filter VISERA XENON LIGHT SOURCE
■ Specifications
Camera Head Dimensions
Weight
ø29 x 85 mm (from mount surface)
215 g (excluding cable)
Number of remote control switches: 3
CLV-S40
Cable ø6.8 mm x 4 m
Cleaning/Disinfection Immersible in disinfectant solution
A high-quality light source with a powerful 300W xenon lamp.
Sterilization Ethylene oxide gas sterilization and steam (autoclave) sterilization possible.

■ Specifications
AUTOCLAVABLE CAMERA HEAD
Power Voltage (AC) 120 V, 220 V, 230 V, 240 V Illumination Cooling Forced-air cooling

OTV-S7H-NA-10Q OTV-S7H-NA-12Q OTV-S7H-1NA-12Q


1.0x, Quick-lock type 1.2x, Quick-lock type 1.2x, Quick-lock type, w/built-in moiré filter
Requirements (see electrical ranging plate)
Frequency 50/60 Hz
Emergency lamp
Emergency Lamp Life
Halogen lamp (without mirror) 24 V 150 W
Approx. 500 hours on continuous use
Input 6 A (120 V) , 3 A (220 V, 230 V, 240 V) (In intermittent use, the lamp life may differ slightly)
■ Specifications Voltage Fluctuation Within ±10% Visual Observation Control Method (automatic) Servo-diaphragm
Camera Head Dimensions ø29 x 113 mm (Diameter of focus ring x total length) Size Dimensions 295 (W) x 125 (H) x 395.4 (D) mm (maximum) Video System Automatic Sensitivity (AUTO) 17 steps
Weight 190 g (excluding cable) Weight 12 kg Front Panel Emergency Lamp Indicator Indicates that the emergency lamp is operating, and
Cable ø6.8 mm x 4 m Illumination Lamp Xenon short-arc lamp (ozone-free) 300 W blinks when the emergency lamp is broken.
Number of remote control switches: 3
Cleaning/Disinfection Immersible in disinfectant solution Lamp Life Approx. 500 hours on continuous use Intensity-Mode Memory Indicator Indicates that Intensity-Mode Memory is selected.
Sterilization Ethylene oxide gas sterilization and steam (autoclave) sterilization possible. (In intermittent use, the lamp life may differ slightly) Standby Mode Indicator Indicates that the standby mode is selected.
Ignition Switching regulator Setting Retention Selected settings are retained when the light source
AUTOCLAVABLE FOCUS FREE CAMERA HEAD Brightness Adjustment Light-path diaphragm control is switched off.
OTV-S7H-FA/1FA-E

OTV-S7H-FA-E OTV-S7H-1FA-E OTV-S7H-FA-Q


■ Specifications Ancillary Equipment
Camera Head Dimensions ø36 x 125 mm (Diameter of focus ring x total length)
Weight 240g (excluding cable)
Cable ø6.8 mm x 4 m Number of remote control switches: 2
Cleaning/Disinfection Immersible in disinfectant solution with a video adapter attached.
OTV-S7H-FA-Q
Sterilization Ethylene oxide gas sterilization and steam (autoclave) sterilization possible.

LCD MONITOR TROLLEY HIGH FLOW INSUFFLATION UNIT


Number of remote control switches: 2

■ Common Specifications OEV191H/191 WM-SC UHI-3


Observation Pickup System Interline type CCD solid-state image pickup, Picture elements 410,000 (NTSC), 470,000 (PAL) Size 19 inch: 430 (W) x 386 (H) x 95 (D) mm Size 1,500 (H) x 605 (W) x 656 (D) mm
Resolution (at center) Horizontal: over 640 lines Weight 8.0 kg Weight 72.25 kg Powerful 35 L/min. insufflation that
Sensitivity 1.3 higher than the OTV-S6 under the same condition.
* LCD is not included. quickly responds to abdominal
OTV-S7H-N/1N/1D/NA/1NA: Minimum illumination 1.4 Lux (F1.4, AGC ON, 30% full video)
S/N Greater than 49 dB (AGC OFF, DARK)
gas leaks.
Classification Degree Of Protection Against Electric Shock Type CF, Type BF (OTV-S7H-1D-F08E/L08E)
(Electro-Medical Equipment) Degree Of Protection Against Explosion The product should be kept away from flammable gases.