Manual Olympus
Manual Olympus
GENERAL
SURGERY
High-Performance
Digital Documentation
An extensive lineup for your needs. Adding functions later is also possible.
DV Unit PC Card Unit P in P Unit Orientation Unit
Type B Upgrade for Your Needs!
Type C PC Card P in P Multi- Orientation
Basic DV Unit Unit Unit Freeze Unit
Type D Unit
Type F
Office or
Multi-Specialty Standardized
Operating
Compatibility Control VISERA is also compatible with the EndoALPHA
Room
Olympus Integrated Endosurgery System.
When used with the EndoALPHA Olympus Integrated
VISERA Concept Endosurgery System, VISERA camera functions can be
VISERA allows the interconnection of a variety of videoscopes and camera heads. controlled via voice navigation and touch control, thus
It lets you share equipment and standardize control, enhancing the service, efficiency, greatly improving efficiencies in your operating room.
and affordability of endoscopy in your hospital.
PC Card DV Output
2 3
Superior Lineup
V ideoscopes
Dynamic, High-Quality
LTF TYPE VP/V3 VISERA Laparo-Thoraco Videoscope
Imaging Solutions
The VISERA lineup includes videoscopes with superb image
LTF TYPE VP Superb Image Quality from a Simultaneous- ● Wider Depth of Field and Tip Angulation
Multicolor CCD and Angulation in 4 Directions. in Four Directions
quality, from a simultaneous-multicolor CCD on their distal
The LTF TYPE VP/V3 features a compact The LTF TYPE VP/V3 has a wider depth of field for finer observation
tips. There are also a variety of camera heads, including control section for easy one-handed use. of organs. The tip's angulation range makes it possible to view forceps
The shorter bending section allows smoother from directly above, letting you cut tissues more smoothly.
autoclavable ones, allowing you to choose whichever most
LTF TYPE V3 orientation, even in narrow cavities. LTF-VP/ V3
suits your needs.
Forceps
A Variety of
Camera Heads Autoclavable Camera Heads
Three types of autoclavable camera heads are available: Normal, Quick and Cost-Effective Autoclave Sterilization
Eyepiece-Integrated, and Quick-Lock Integrated, letting you
Lets You Keep Up with Higher Numbers of Surgeries.
choose the one that best suits your needs.
It only takes approx. 10 to 60 minutes to autoclave,
so you don't have to worry about higher numbers of surgeries.
Autoclaving is also cost-effective and known for its safety.
4 5
Digital Documentation
SmartMedia*
● Conferences
xD-Picture Card
Digital Data
in Various Formats
Smooth Recording
Still/Moving Image Recording with Smart Storage and
Remote Control Switches
Volume Ratio
Only 8%
Management
of VHS
Compact and Convenient
Both still and moving images can be stored as
VHS tape DV tape compact digital data. A server and network
* SmartMedia is a trademark of TOSHIBA Corporation. Digital Videotapes via IEEE
● Space-Saving Digital Videotape make managing them hassle-free.
6 7
System Chart
OTV-S7V
VISERA Video System Center
AR-TL12S (Compatible with EndoALPHA)
MH-999S Video Adapter OTV-S7H-N/1N/1D
Rigid Endoscope Video Coupler (Screw) Camera Head
Eyepiece
AR-T10S/T12S, Type B
SmartMedia * xD-Picture Card
AR-T10SA/T12SA
MH-999E Video Adapter OTV-S7H-NA-10E/12E
Video Coupler (Eyepiece)
OTV-S7H-1NA-10E/12E
Autoclavable Camera Head
AR-T10/T12 Type C
Rigid Endoscope MH-999Q Video Adapter
Video Coupler
(Quick-Lock)
PC Card Adapter
OTV-S7H-NA-10Q/12Q
AR-TZ2 for xD-Picture Card/SmartMedia
OTV-S7H-1NA-12Q
Video Adapter Autoclavable Camera Head Type D
AR-T10Q/T12Q,
A3298 AR-T10QA/12QA
Light Guide Cable Video Adapter
Fiberscope OTV-S7H-FA/1FA-E
Autoclavable Focus Free Camera Head
AR-T10E/T12E, AR-T10EA/12EA OEV191H/191
Video Adapter LCD Monitor
OTV-S6
OES VIDEO SYSTEM
MAJ-944
OTV-S7H-FA-Q Light Control Cable
LTF-VP/V3 Autoclavable Focus Free Camera Head
Deflectable-Tip Video Laparoscope
MAJ-1345
Lens Cleaning Sheath For LTF-V3
MAJ-1124
Note: The Olympus VISERA Video System can be configured for cardiac applications only when Type CF Keyboard For OTV-S7
applied parts (camera heads and light guide cables) bearing the symbol are used. MAJ-1200
OTV-S7H-1D-F08E/L08E CLV-S40 Universal Light MAJ-1324
Camera Head Xenon Light Source Guide Adapter P Converter
A500**A
Rigid Videoscope
* SmartMedia is a trademark of TOSHIBA Corporation.
VISERA Lineup
Video System Center ■ Specifications (When all B.O.D. units are installed in the OTV-S7V)
Power Supply Voltage 100 - 240 V AC *1 Observation Patient Data Input Patient data can be entered.
VISERA VIDEO SYSTEM CENTER Voltage Fluctuation Within ±10% Menu Patient Data Display Patient data display is set to ON/OFF.
Frequency 50/60 Hz Shutter Shutter is set to ON/OFF.
OTV-S7H-N OTV-S7H-1N
w/built-in moiré-filter
OTV-S7H-1D
w/built-in moiré-filter
LTF TYPE VP/V3
■ Specifications A high-resolution videoscope capable of angulation in 4 directions.
Camera Head Dimensions ø27 x 37 mm (from mount surface)
Weight 40 g (excluding cable) ■ Specifications
Cable ø5.2 mm x 4 m Model LTF TYPE VP LTF TYPE V3
Number of remote control switches: 2
Cleaning/Disinfection Immersible in disinfectant solution with a video adapter attached. Optical System Field Of View 80° 90°
Sterilization Ethylene oxide gas sterilization possible.
Direction Of View 0° (forward viewing)
Depth Of Field 18 - 100 mm 15 - 100 mm
CAMERA HEAD Insertion Portion Distal End Outer Diameter ø5.4 mm ø10 mm
Rigid Portion Outer Diameter ø5.3 mm ø10 mm
OTV-S7H-1D-F08E OTV-S7H-1D-L08E
Eye-piece type, w/finder, w/built-in moiré-filter Eye-piece type, w/built-in moiré-filter Bending Section
Working Length
Angulation Range
370 mm
Up 100°, Down 100°,
330 mm
Up 100°, Down 100°,
Right 100°, Left 100° Right 60°, Left 60°
■ Specifications Total Length 3600 mm
Number of remote control switches: 3
Camera Head Dimensions Endoscopic mount: ø45.2 x 12.1 mm
Finder block: 25W x 17.7H x 17.2D mm
Camera head: ø14 x 45 mm VISERA LAPARO-THORACO VIDEOSCOPE
Weight 45 g (excluding cable)
Cable
Cleaning/Disinfection
ø3.3 x 4 m
Immersible in disinfectant solution. A50001A /A50003A /A50021A /A50023A
Sterilization Ethylene oxide gas sterilization possible.
High-resolution videoscopes with image rotation*.
AUTOCLAVABLE CAMERA HEAD * With 30°-view models.
OTV-S7H-NA OTV-S7H-1NA
w/built-in moiré-filter
■ Specifications
Model A50001A A50003A Model
Number of remote control switches: 3
A50021A A50023A
Display Full Screen Display Full Screen
■ Specifications
Television System NTSC Television System NTSC
Camera Head Dimensions ø29 x 85 mm (from mount surface)
Picture Elements 410,000 Picture Elements 270,000
Weight 125 g (excluding cable)
Direction Of View 0° 30° Direction Of View 0° 30°
Cable ø6.8 mm x 4 m
Number of remote control switches: 2 Field Of View 70° Field Of View 70°
Cleaning/Disinfection Immersible in disinfectant solution with a video adapter attached.
Depth Of Field 20 to 100 mm Depth Of Field 15 to 100 mm
Sterilization Ethylene oxide gas sterilization and steam (autoclave) sterilization possible.
Outer Diameter 10 mm Outer Diameter 5.4 mm
Working Length 300 mm Working Length 300 mm
AUTOCLAVABLE CAMERA HEAD Image Rotation Function Image Rotation Function
OTV-S7H-NA-10E OTV-S7H-1NA-10E
Dedicated Autoclave Tray 595 (L) x 295 (W) x 61 (H) mm Dedicated Autoclave Tray 595 (L) x 295 (W) x 61 (H) mm
■ Specifications
AUTOCLAVABLE CAMERA HEAD
Power Voltage (AC) 120 V, 220 V, 230 V, 240 V Illumination Cooling Forced-air cooling
10 11
VISERA VIDEO SYSTEM
GENERAL
SURGERY