Mangalagiri Final Staircase
Mangalagiri Final Staircase
Mangalagiri Final Staircase
4.5
Thickness of the waist slab 150 mm No. of risers
###
Cover to the reinforcement 45 mm
Main R/F
Area of steel required, Ast = M/(σst j d) = 2075.1 mm²
Min. area of steel = 525 mm²
Dia of main reinforcement = 12 mm
Area of single bar, Ab = 113.1 mm²
Spacing of the bars required = 54.5 mm
Say 100 mm 2010
Percentage of steel, Pt = 1.142 %
Distribution R/F
Dia of main reinforcement = 10 mm
Area of single bar, Ab = 78.5 mm²
Spacing of the bars required = 149.5 mm
Say 125 mm
Reinforcement details
Area of steel required, Ast = M/(σst j d) = 170.5 mm²
Min. area of steel = 446.3 mm²
Dia of main reinforcement = 16 mm
Area of single bar, Ab = 201.1 mm²
No. of bars required = 2.22
Say 3
Percentage of steel, Pt = 0.473 %
Provide main steel of 16mm dia bars of 3 no.s.
Reinforcement details
Area of steel required, Ast = M/(σst j d) = 80.4 mm²
Min. area of steel = 446.3 mm²
Dia of main reinforcement = 16 mm
Area of single bar, Ab = 201.1 mm²
No. of bars required = 2.22
Say 3
Percentage of steel, Pt = 0.473 %
Provide main steel of 16mm dia bars of 3 no.s.
Design constants
Grade of concrete M 30
Grade of steel Fe 500
Compressive stress in columns subjected to direct load σsc = 190 N/mm²
σcbc
Column Width 0.45 m σst
Depth 0.45 m m
Unsupported length of the column (x-axis) 2.075 m k
Clear cover provided 45 mm j
Cross Sectional Area of the Column 202500 mm² Q
Design axial load (Factored) 88.23 kN
Self wt. of the column 10.505 kN
Lateral Ties
Dia of the bar 10 mm
Pitch of the ties 250 mm
Provide lateral ties of 10mm dia bars at 250mm c/c spacing.
(VI) DESIGN OF FOUNDATION SLAB, S₃
DESIGN OF COLUMN FOOTING
Thickness of foundation slab = 450 mm
Depth of footing below ground level = 1.50 m
Safe bearing capacity = 8 t/m²
Max. allowable bearing capacity = 75 kN/m²
Footing projection on from face of column width 0.98 m (Assumed)
Thickness = 0.45 m
Footing projection on from face of column depth 0.98 m (Assumed)
Thickness = 0.45 m
Width of column = 0.3 m
Depth of column = 2.075 m
Total width of footing = 2.25 m
Total length of footing = 2.25 m
Cover to the reinforcement = 45 mm
Load and moments in the footing
(a) Load due to stair case & self weight of column = 98.735 kN
Design of footing
Moment obtained = 2.585 kN-m
Minimum thickness required = 88.1 mm
√(6M/fB) OK
Effective depth provided = 399 mm
Reinforcement details
Area of steel required, Ast = 57.9 mm²
Min. area of steel required = 787.5 mm²
Dia of main reinforcement = 12 mm
Area of single bar = 113.1 mm²
Spacing required = 143.6 mm
Spacing provided = 125 mm