This document provides information on auxiliary contact blocks for contactors. It includes: 1) Auxiliary contact blocks extend the number of contacts on contactors up to 4 through different combinations and switch on simultaneously with the contactor. 2) They have insulation voltage of 690V and connecting terminals of screw terminals. 3) Auxiliary contact blocks mount vertically on the movable cover of contactors through clamping and can be mounted at a gradient of up to 5 degrees.

Uploaded by

Pajls IV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views1 page

DN22

This document provides information on auxiliary contact blocks for contactors. It includes: 1) Auxiliary contact blocks extend the number of contacts on contactors up to 4 through different combinations and switch on simultaneously with the contactor. 2) They have insulation voltage of 690V and connecting terminals of screw terminals. 3) Auxiliary contact blocks mount vertically on the movable cover of contactors through clamping and can be mounted at a gradient of up to 5 degrees.

Uploaded by

Pajls IV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CONTACTORS

AUXILIARY CONTACT BLOCKS www.elmarkholding.eu

Documents corresponding to the


product:
AUXILIARY CONTACTS
5 YEAR
WARRANTY
*for industrial
usage, 3 years
warranty

Standard EN 60947-4-1
AUXILIARY CONTACTS • insulation voltage: 690V
At necessity the element provide auxiliary number of • Joining terminal: screw terminal
contacts. They are specially designed for mounting • Connecting:
on the movable part of the magnetic core of the ÌÌ flexible conductors with or without cable terminal
contactors LT 1K/D series. ÌÌ rigid conductors

FUNCTIONS: MOUNTING:
• extending the number of the operative contactors • on the movable cover of the contactor through
up to 4 in different pinching
• Combinations • mounting position: vertical gradient – maximum± 5°
ÌÌ switches on simultaneously with the other • Plastic: wear resistance of UV rays and non-
contact system of the contactor flammable (self-extinguishing material)
• Operation class: AC 3
Type Number of contacts Rated current Section of the conductor Catalogue number
(mm2)

LT01-DN02 2NC 6A 0,5-1 23002


LT01-DN11 NO+NC 6A 0,5-1 23011
LT01-DN20 2NO 6A 0,5-1 23020
LT01-DN22 2NO+2NC 6A 0,5-1 23022
Dimensions (mm)
LT01-DN40 4NO 6A 0,5-1 23040
H W L W1 W2
LT01-DN04 4NC 6A 0,5-1 23004
32 40 35 26 45
LT01-KN11 NO+NC 6A 0,5-1 23001
H2 L1 L2
LT01-KN22 2NO+2NC 6A 0,5-1 23003
48 6,5 37

AUXILIARY CONTACTS LT03-DN11


5 YEAR
WARRANTY
*for industrial
usage, 3 years
warranty

Providing on necessity additional number of plug ÌÌ flexible conductors with or without cable end
points and are mounted sideward to the movable part ÌÌ solid conductors
of the magnetic cores of contactors of the series LT1 • Mounting method:
D. Variants with two additional plug points NO and NC ÌÌ mounting position – sideward to the contactor
are offered. • Plastic: resistant to UV and non-burning (self-
CONTACTORS

extinguishing material)
FUNCTIONS:
• expanding the number of the operational plug
points
• switching on simultaneously with the rest of the
contact system
• of the contactor
Dimensions (mm)

72 W1 W2 H L A TECHNICAL CHARACTERISTICS:
73 48 22 12,5 72 • Environment operational regime: АС 3
• Insulation voltage: 690V
• Double connector: screw connector
• Connection:
AUXILIARY CONTACT BLOCKS

Type Rated current Section of the conductor (mm2) Catalogue number

LТ03-DN11 6A 0,5-1 23311

TIME DELAY CONTACT BLOCK LT02-DXX


5 YEAR
WARRANTY
*for industrial
usage, 3 years
warranty

LT02-Dxx is designed to set time intervals from 0.1 to 180s in different control schemes. It is used most frequently
in combination with contactors from LT1-Dxx series to form “star/delta” starters for electrical motor control, as it
provides the necessary time for motor winding.

Type Number of contacts Time delay Catalogue number


Dimensions (mm) LТ02-DT0 NO+NC 0.1~3s 23901
W W2 L1 h1 h2 H LТ02-DT2 NO+NC 0.1~30s 23902
33 45 48 22 14 59 LТ02-DT4 NO+NC 10~180s 23903