Wireless Field Interface Product Sheet
Wireless Field Interface Product Sheet
The interface offers significant The WFI Offers a Range of Features to Secure the
benefits for terminals where Greatest Benefits from Industrial Wireless:
• Fully ISA100 compliant, suitable for integration into any ISA100 network
tanks are often widely
• Support for 3rd party gauges allowing GPU emulation
dispersed, communication
• Meshing capabilities for increased redundancy, reduced downtime
cables are missing or the and simplified infrastructure
existing cable network is • Over-the-air key deployment and software upgrades to eliminate
deteriorating or inadequate. tank climbs and boost safety
Building a new, wired • The highest level of security to prevent network intrusions
and cyber security attacks
infrastructure in such cases • Support for local security key deployment (if required by customer
is costly and requires long or regulations)
lead times. • Legal metrology approval for custody transfer applications
With the ISA100 Wireless Device Manager (WDM), the CIU, Entis and
Engauge can be connected using the GPU protocol. It also offers native
Experion® integration and connection to any 3rd party device via MODBUS
Serial/TCP, OPC or HART.
Commissioning
The SmartView handheld tool, available as an option, can be connected
to the WFI for monitoring (such as reviewing signal strength and the
communication status) and to commission the WFI locally.
Figure 5-1 — Main dimensions
of the WFI in mm [inches]
212 [8.346]
206 [8.11]
169 [6.654]
229 [9.016]
Technical Specifications
Mechanical (Dimensions) Connection to SmartView
Width 24.8-cm/9.8-inch The SmartView is a portable tool via which users can communicate with
the WFI. With SmartView, users can use the SmartView board(RI-SMV)
Height 21.2-cm/8.3-inch as an optional board.
Depth 16.9-cm/6.6 inch
Weight approx. 10 kilograms
Cable Entries 2½” NPT or 2¾” NPT via converter
Mounting Rail bracket
Environmental
Connecting WFI with SmartView
Ambient -40 °C to +65 °C (-40 °F to +149 °F)
Temperature
Approvals
Storage -40 °C to +65 °C (-40 °F to +149 °F)
Temperature CE, FCC, ETSI, IC, WPC, WCI, OIML R85