HNXC Special Cables-1
HNXC Special Cables-1
www.cncuxc.com 1
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation
Multipairs, Twisted in Bundles,Collective Screen .............................................................................................................. 4
Single Pair or Triple, Collective Screen .............................................................................................................................. 6
Multipairs, Layers, Collective Screen ................................................................................................................................. 7
Multipairs, Layers, Individual and Collective Screen ......................................................................................................... 9
Multitriples, Layers, Collective Screen ............................................................................................................................. 10
Multitriples, Layers, Collective Screen ............................................................................................................................. 12
Multitriples, Layers, Individual and Collective Screen..................................................................................................... 13
Multitriples, Layers, Individual and Collective Screen..................................................................................................... 15
Single Pair, Collective Screen , Galvanized Steel Wire Armour ....................................................................................... 16
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour ............................................................................ 17
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour ............................................................................ 19
Individual and Collective Screen, Galvanized Steel Wire Armour ................................................................................... 20
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour .................................................... 22
PE Insulation
Multipairs, Twisted in Bundles, Collective Screen ........................................................................................................... 23
Single Pair or Triple, Collective Screen ............................................................................................................................ 25
Multipairs, Layers, Collective Screen ............................................................................................................................... 26
Multipairs, Layers, Collective Screen ............................................................................................................................... 28
Multipairs, Layers, Individual and Collective Screen ....................................................................................................... 29
Multipairs, Layers, Individual and Collective Screen ....................................................................................................... 31
Multitriples, Layers, Collective Screen ............................................................................................................................. 32
Multitriples, Layers, Collective Screen ............................................................................................................................. 34
Multitriples, Layers, Individual and Collective Screen..................................................................................................... 35
Multitriples, Layers, Individual and Collective Screen..................................................................................................... 37
Single Pair, Collective Screen, Galvanized Steel Wire Armour ........................................................................................ 38
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour ............................................................................ 39
Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour ............................................................................. 41
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour .................................................... 42
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour .................................................... 44
Multicores, Layers, Overall Screen of Tinned Copper Wire Braid .......................................................................... 45
Single Pair, Collective Screen of Tinned Copper Wire Braid ........................................................................................... 46
Multipairs, Layers, Overall Screen of Tinned Copper Wire Braid .................................................................................... 47
Multipairs, Layers, Overall Screen of Plain or Tinned Copper Wire Braid ...................................................................... 48
Fire Resistant Cables
Multipairs, Layers, Collective Screen, Stranded Conductor ............................................................................................. 51
Multipairs, Layers, Collective Screen, Stranded Conductor ............................................................................................. 53
Multipairs, Layers, Individual and Collective Screen, Stranded Conductor ..................................................................... 54
Multipairs, Layers, Individual and Collective Screen, Stranded Conductor ..................................................................... 56
Multicores, Unscreened, Stranded Conductor................................................................................................................... 57
Multipairs, Layers, Collective Screen, Stranded Conductor ............................................................................................. 58
Multicores, Unscreened, Solid Conductor ........................................................................................................................ 59
2 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Solid Conductor ................................................................................................... 60
Multicores, Unscreened, Flexible Conductor.................................................................................................................... 61
Multipairs, Layers, Collective Screen, Flexible Conductor .............................................................................................. 62
Solid Copper Conductors
PVC Insulation, PVC Sheathed ........................................................................................................................................ 63
Stranded Copper Conductors
PVC Insulation, PVC Sheathed ........................................................................................................................................ 64
PVC Insulation, Copper Tape Screened, PVC Sheathed................................................................................................... 65
PVC Insulation, Copper Tape Screened, PVC Sheathed................................................................................................... 66
PVC Insulation, Steel Tape Armoured, PVC Sheathed ..................................................................................................... 67
PVC Insulation, Steel Tape Armoured, PVC Sheathed ..................................................................................................... 68
PVC Insulation, Steel Wire Armoured, PVC Sheathed ..................................................................................................... 69
PVC Insulation, Steel Wire Armoured, PVC Sheathed ..................................................................................................... 70
PVC Insulation, Steel Wire Armoured, PVC Sheathed ..................................................................................................... 71
PVC Insulation, Steel Wire Armoured, PVC Sheathed ..................................................................................................... 72
Unscreened Twisted Pairs(UTP)
Data Cable – Category 5e ............................................................................................................................................. 73
Foil Screened Twisted Pairs(STP)
Data Cable – Category 5e ............................................................................................................................................. 74
Unscreened Twisted Pairs(UTP)
Data Cable – Category 6 ............................................................................................................................................... 75
Telephone Cable
PVC Insulated Multipairs.................................................................................................................................................. 76
PVC Insulated Multipairs.................................................................................................................................................. 77
PVC Insulated Multipairs.................................................................................................................................................. 78
Coaxial Cables
MATV Cables ................................................................................................................................................................... 80
MATV Cables ................................................................................................................................................................... 81
RG Cables ......................................................................................................................................................................... 82
RG Cables ......................................................................................................................................................................... 83
Automotive Wires
PVC Insulation .................................................................................................................................................................. 84
Heat – Resistant PVC Insulation ................................................................................................................................... 85
Heat – Pressure Resistant PVC Insulation .................................................................................................................... 86
Cold – Resistant PVC Insulation................................................................................................................................... 87
Concentric Conductors with PVC Insulation .................................................................................................................... 88
PVC Thin Insulation ......................................................................................................................................................... 89
Flexible PVC Cables
HO5VV-F .......................................................................................................................................................................... 90
HO3VV-F .......................................................................................................................................................................... 91
Flat Cords
By To Multiply By To obtain ................................................................................................................................... 104
www.cncuxc.com 3
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Twisted in Bundles,Collective Screen
Application:
Standard:
BS 5308-2
Rated Voltage: Wrapping:
300/500 V Polyester tapes
Conductor: Collective Screen:
Stranded annealed plain copper Aluminum polyester tape with tinned drain wire and wrapped by
Insulation: polyester tapes
Polyvinylchloride TI1 to BS 6746 Sheath:
Assembly: Polyvinylchloride TM1 to BS 6746 colour black or grey or blue
Cores twisted to form pairs, 4 pairs twisted to form a bundle, Minimum bending radius:
bundles twisted in concentric layers, 2 pairs twisted as star 7.5*d (d= overall diameter)
quad Temperature rating:
Colour code: +5oC up to + 50oC during operaion
One Pair : Blue / Red Packing:
Two Pairs : Grey / Yellow On non-returnable wooden drums
Three Pairs : Green / Brown
Four Pairs : White / Black
Bundles are identified by coloured polyester Tapes.
TECHNICAL INFORMATION
Conductor Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs insulation
Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20℃
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 1 7.9 80
4 7 x 0.3 39.2 0.6 1 10.1 100
8 7 x 0.3 39.2 0.6 1 12.1 160
0.5
12 7 x 0.3 39.2 0.6 1.2 14.4 230
16 7 x 0.3 39.2 0.6 1.2 16.1 300
20 7 x 0.3 39.2 0.6 1.2 18.5 360
4 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
24 7 x 0.3 39.2 0.6 1.4 20.3 450
2 7 x 0.43 18.4 0.6 1 8.9 100
4 7 x 0.43 18.4 0.6 1 12 160
8 7 x 0.43 18.4 0.6 1.2 16 300
1 12 7 x 0.43 18.4 0.6 1.4 20 430
16 7 x 0.43 18.4 0.6 1.4 22 550
20 7 x 0.43 18.4 0.6 1.4 24.3 660
24 7 x 0.43 18.4 0.6 1.6 26.7 800
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 5
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Single Pair or Triple, Collective Screen
Application:
These cables are used in the chemical and petrochemical industries for the transmission of analogue and digital
Standard: Screen:
BS 5308-2 Collective screen aluminum polyester tape with
Rated Voltage: tinned drain wire and wrapped by polyester tapes
300/500 V Sheath:
Conductor: Polyvinylchloride TM1 to BS 6746 colour black or grey
Stranded annealed plain copper or blue
Insulation: Minimum bending radius:
Polyvinylchloride TI1 to BS 6746 7.5*d (d= overall diameter)
Assembly: Temperature rating:
cores twisted to form a pair or triple and +5oC up to + 50oC during operaion
wrapped by polyester tapes Packing:
Colour code: On non-returnable wooden drums
Pair : White / Black
Triple : Black / White / Red
TECHNICAL INFORMATION
Conductor
Nominal insulation Nominal sheath Approximate Approximate net
Cable Size
Max. DC Res. At thickness thickness overall diameter weight
No.x dia.
20°C
TECHNICAL INFORMATION
Conductor
Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs insulation
Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.3 39.2 0.6 1 10.3 122
4 7 x 0.3 39.2 0.6 1 11.1 140
8 7 x 0.3 39.2 0.6 1.2 14.7 240
12 7 x 0.3 39.2 0.6 1.3 17 340
0.5
16 7 x 0.3 39.2 0.6 1.3 18.9 433
20 7 x 0. 3 39.2 0.6 1.3 21 518
24 7 x 0. 3 39.2 0.6 1.5 23.7 636
30 7 x 0. 3 39.2 0.6 1.5 26.3 867
www.cncuxc.com 7
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1 11.2 149
4 7 x 0.37 24.6 0.6 1 11.9 165
8 7 x 0.37 24.6 0.6 1.2 15.8 291
12 7 x 0.37 24.6 0.6 1.3 18.3 409
0.75
16 7 x 0.37 24.6 0.6 1.3 20.4 523
20 7 x 0.37 24.6 0.6 1.3 22.8 631
24 7 x 0.37 24.6 0.6 1.5 25.7 770
30 7 x 0.37 24.6 0.6 1.7 26.4 902
8 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of Max. DC Res. insulation
thickness overall diameter weight
pairs No.x dia. At thickness
20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.43 18.4 0.6 1.2 12.2 172
4 7 x 0.43 18.4 0.6 1.2 13.1 201
8 7 x 0.43 18.4 0.6 1.3 17.2 351
12 7 x 0.43 18.4 0.6 1.3 19.7 486
1.0
16 7 x 0.43 18.4 0.6 1.3 21.9 626
20 7 x 0.43 18.4 0.6 1.5 25.0 670
24 7 x 0.43 18.4 0.6 1.5 27.6 923
30 7 x 0.43 18.4 0.6 1.7 30.5 1253
2 7 x 0.49 14.2 0.6 1.2 12.8 195
4 7 x 0.49 14.2 0.6 1.3 14.0 245
8 7 x 0.49 14.2 0.6 1.3 18.2 425
12 7 x 0.49 14.2 0.6 1.3 20.3 615
1.3
16 7 x 0.49 14.2 0.6 1.5 23.2 790
20 7 x 0.49 14.2 0.6 1.5 27.0 880
24 7 x 0.49 14.2 0.6 1.7 31.2 1100
30 7 x 0.49 14.2 0.6 2.0 34.5 1450
2 7 x 0.53 12.6 0.6 1.2 14.1 228
4 7 x 0.53 12.6 0.6 1.2 15.4 273
8 7 x 0.53 12.6 0.6 1.3 20.3 480
12 7 x 0.53 12.6 0.6 1.5 24.0 700
1.5
16 7 x 0.53 12.6 0.6 1.5 26.7 904
20 7 x 0.53 12.6 0.6 1.7 30.2 1119
24 7 x 0.53 12.6 0.6 2.0 34.0 1370
30 7 x 0.53 12.6 0.6 2.2 37.4 1845
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 9
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Collective Screen
Application:
These cables are used in the chemical and petrochemical industries for the transmission of analogue and
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
triples No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.3 39.2 0.6 1.0 10.1 125
4 7 x 0.3 39.2 0.6 1.0 10.8 150
8 7 x 0.3 39.2 0.6 1.2 14.6 245
12 7 x 0.3 39.2 0.6 1.3 16.5 347
0.5
16 7 x 0.3 39.2 0.6 1.3 18.7 450
20 7 x 0.3 39.2 0.6 1.3 21.2 565
24 7 x 0.3 39.2 0.6 1.5 24.0 670
30 7 x 0.3 39.2 0.6 1.5 27.7 975
10 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1.0 10.9 145
4 7 x 0.37 24.6 0.6 1.0 11.8 190
8 7 x 0.37 24.6 0.6 1.3 15.9 375
12 7 x 0.37 24.6 0.6 1.3 17.9 435
0.75
16 7 x 0.37 24.6 0.6 1.3 20.2 535
20 7 x 0.37 24.6 0.6 1.5 23.8 675
24 7 x 0.37 24.6 0.6 1.5 26.0 970
30 7 x 0.37 24.6 0.6 1.7 30.0 1175
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 11
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Collective Screen
TECHNICAL INFORMATION
Conductor
Nominal
Number of Nominal sheath Approximate Approximate
Conductor size insulation
triples Max. DC Res. thickness overall diameter net weight
No.x dia.No. x thickness
At 20°C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
12 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Individual and Collective Screen
Application:
Standard: Wrapping:
BS 5308-2 Polyester tapes
Rated Voltage: Collective Screen
300/500 V Aluminum polyester tape with tinned drain wire
Conductor: and wrapped by polyester tapes
Stranded annealed plain copper Sheath:
Insulation: Polyvinylchloride TM1 to BS 6746 colour black or
Polyvinylchloride TI1 to BS 6746 grey or blue
Assembly: Minimum bending radius:
Cores twisted to form triples, triples screened 7.5 x d (d= overall diameter)
by aluminum polyester tapes, screened triples Temperature rating:
twisted in concentric layers, and wrapped by +5oC up to + 50oC during operation
polyester tapes Packing:
Colour code: On non-returnable wooden drums
Black / White / Red, continuously numbered,
or identification tapes numbered
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate
Conductor size insulation
triples Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20°C
www.cncuxc.com 13
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
24 7 x 0.3 39.2 0.6 1.5 26.6 835
30 7 x 0.3 39.2 0.6 1.7 29.2 1130
2 7 x 0.37 24.6 0.6 1 12.5 165
4 7 x 0.37 24.6 0.6 1.2 14.1 235
8 7 x 0.37 24.6 0.6 1.3 18.3 395
12 7 x 0.37 24.6 0.6 1.3 21.1 550
0.75
16 7 x 0.37 24.6 0.6 1.5 24.2 720
20 7 x 0.37 24.6 0.6 1.7 26.7 875
24 7 x 0.37 24.6 0.6 1.7 28.8 1030
30 7 x 0.37 24.6 0.6 2 32.4 1325
14 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate
Conductor size Max. DC Res. insulation
Triples No.x dia. thickness overall diameter net weight
At 20°C thickness
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 15
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Single Pair, Collective Screen, Galvanized Steel Wire Armour
Application:
These cables are used in the chemical and petrochemical industries for the transmission of analogue
TECHNICAL INFORMATION
Conductor
Nominal Nominal Approximate
Conductor Number of steel wire Approximate
insulation sheath overall
size pairs Max. DC Res. diameter net weight
No.x dia.No. x thickness thickness diameter
At 20oC
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
16 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Galvanized Steel
Wire Armour
Standard: numbered
BS 5308-2 Screen:
Collective screen of aluminium polyester tape with
Rated Voltage: tinned drain wire and wrapped by polester tapes
300/500 V Bedding:
Conductor: Polyvinylchloride
Stranded annealed plain copper Armouring;
Insulation: Galvanized steel wire armour to BS 1442
Polyvinylchloride TI1 to BS 6746 Sheath:
Assembly: Polyvinylchloride TM1 to BS 6746 colour black or blue
Cores twisted to form a pairs, pairs twisted Minimum bending radius:
in concentric layers and wrapped by 10 x d (d= overall diameter)
polyester tapes Temperature rating:
Colour code: +5oC up to + 50oC during operation
Black / White continuously Packing:
numbered, or identification tapes On non-returnable wooden drums
TECHNICAL INFORMATION
Conductor
Number Nominal Nominal Approximate Approximate
steel wire
Conductor size of insulation sheath overall net
Max. DC Res. diameter
pairs No.x dia. thickness thickness diameter weight
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm mm Kg/Km
mm
www.cncuxc.com 17
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 344
4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 395
8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 665
12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 800
0.5
16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 920
20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1220
24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1370
30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1710
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 395
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 440
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 760
12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 905
0.75
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1240
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1390
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1580
30 7 x 0.37 24.6 0.6 1.6 2.0 36.1 1800
18 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
Conductor
Nominal Nominal Approximate
Conductor Number of steel wire Approximate
insulation sheath overall
size pairs Max.DC Res. diameter net weight
No.x dia. thickness thickness diameter
At 20°C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 19
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Individual and Collective Screen, Galvanized Steel Wire
Armour
Application:
Standard: Screen:
BS 5308-2 Collective screen of aluminum polyester tapes with
Rated Voltage: tinned drain wire and wrapped by polyester tapes
300/500 V Bedding:
Conductor: Polyvinylchloride
Stranded annealed plain copper Armouring;
Insulation: Galvanized steel wire armour to BS 1442
Polyvinylchloride TI1 to BS 6746 Sheath:
Assembly: Polyvinylchloride TM1 to BS 6746 colour black or blue
Cores twisted to form a pairs, pairs screened Minimum bending radius:
by aluminium polyester tapes, screened pairs 10 x d (d= overall diameter)
twisted in concentric layers and wrapped by Temperature rating:
polyester tapes +5oC up to + 50oC during operation
Colour code: Packing:
Black / White continuously numbered, or On non-returnable wooden dru
identification tapes numbered
TECHNICAL INFORMATION
Conductor
Number Nominal Nominal Approximate Approximate
Conductor steel wire
of insulation sheath overall net
size Max. DC Res. diameter
pairs No.x dia. thickness thickness diameter weight
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm mm Kg/Km
mm
2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 390
0.5 4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 450
8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 760
20 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 940
16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1260
20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1420
24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1660
30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 2015
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 440
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 490
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 850
12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1210
0.75
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1390
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1620
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1880
30 7 x 0.37 24.6 0.6 2 2.0 36.1 2590
www.cncuxc.com 21
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel
Wire Armour
TECHNICAL INFORMATION
Ohm
mm2 No. No. x mm mm mm mm mm Kg/Km
/Km
2 7 x 0.43 18.4 0.6 1.25 1.5 17.2 570
4 7 x 0.43 18.4 0.6 1.25 1.5 18.6 660
8 7 x 0.43 18.4 0.6 1.25 1.7 23.1 960
12 7 x 0.43 18.4 0.6 1.6 1.7 26.3 1335
1
16 7 x 0.43 18.4 0.6 1.6 1.8 28.7 1570
20 7 x 0.43 18.4 0.6 1.6 1.9 32 1870
24 7 x 0.43 18.4 0.6 1.6 1.9 34.6 2120
30 7 x 0.43 18.4 0.6 2 2.1 38.3 2830
2 7 x 0.49 14.2 0.6 1.25 1.5 18.2 680
4 7 x 0.49 14.2 0.6 1.25 1.6 20.3 850
8 7 x 0.49 14.2 0.6 1.6 1.7 26.4 1350
12 7 x 0.49 14.2 0.6 1.6 1.8 29.5 1560
1.3
16 7 x 0.49 14.2 0.6 1.6 1.9 32 1860
20 7 x 0.49 14.2 0.6 2 2 36.6 2300
24 7 x 0.49 14.2 0.6 2 2.1 39.3 3200
30 7 x 0.49 14.2 0.6 2 2.2 44.2 3900
2 7 x 0.53 12.6 0.6 1.25 1.7 22.8 1000
4 7 x 0.53 12.6 0.6 1.25 1.7 24.1 1130
8 7 x 0.53 12.6 0.6 1.6 1.8 30.4 1690
12 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2130
1.5
16 7 x 0.53 12.6 0.6 1.6 2 38.7 2280
20 7 x 0.53 12.6 0.6 2 2.2 43.3 3430
24 7 x 0.53 12.6 0.6 2 2.3 48.5 4420
30 7 x 0.53 12.6 0.6 2.5 2.5 52.8 5390
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
22 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Twisted in Bundles, Collective Screen
Application:
These cables are used in the chemic al and petrochemical industries for the transmission of analogue and
digital signals for measurements and process control purposes.
TECHNICAL INFORMATION
www.cncuxc.com 23
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 X 0.43 18.4 0.6 1 8.9 85
4 7 X 0.43 18.4 0.6 1 12 140
8 7 X 0.43 18.4 0.6 1.2 16 165
1 12 7 X 0.43 18.4 0.6 1.4 20 390
16 7 X 0.43 18.4 0.6 1.4 22 500
20 7 X 0.43 18.4 0.6 1.4 24 640
24 7 X 0.43 18.4 0.6 1.6 26 780
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
24 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Single Pair or Triple, Collective Screen
Application:
Standard: Wrapping:
BS 5308-2 Polyester tapes
Rated Voltage: Collective Screen:
300/500 V Collective screen of aluminum polyester tapes with
Conductor: tinned drain wire and wrapped by polyester tapes
Stranded annealed plain copper Sheath:
Insulation: Polyvinylchloride TM1 to BS 6746 colour
Polyethelene type 03 to BS 6234 black or blue
Assembly: Minimum bending radius:
Cores twisted to form a pair or triple and 7.5 x d (d= overall diameter)
wrapped by polyester tape Temperature rating:
Colour code: +5oC up to +50oC during operation
Pair: Black / White Packing:
Triple: Black / White / Red On non-returnable wooden drums
TECHNICAL INFORMATION
Conductor
Nominal insulation Nominal sheath Approximate Approximate net
Cable Size Max. DC Res. At
No.x dia. thickness thickness overall diameter weight
20°C
mm2 No. x mm Ohm /Km mm mm mm Kg/Km
1 x 2 x 0.5 7 x 0.3 39.2 0.6 0.8 5.3 40
1 x 3 x 0.5 7 x 0.3 39.2 0.6 0.8 5.6 50
1 x 2 x 0.75 7 x 0.37 24.6 0.6 0.8 6.4 56
1 x 3 x 0.75 7 x 0.37 24.6 0.6 0.8 6.7 65
1 x 2 x 1.0 7 x 0.43 18.4 0.6 0.8 6.8 66
1 x 3 x 1.0 7 x 0.43 18.4 0.6 0.8 7.1 75
1 x 2 x 1.3 7 x 0.49 14.2 0.6 0.8 7.1 75
1 x 3 x 1.3 7 x 0.49 14.2 0.6 0.8 7.4 85
1 x 2 x 1.5 7 x 0.53 12.6 0.6 0.8 7.6 85
1 x 3 x 1.5 7 x 0.53 12.6 0.6 0.8 8 104
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 25
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen
TECHNICAL INFORMATION
Conductor
Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs insulation
Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 1 9.3 98
4 7 x 0.3 39.2 0.6 1 10 112
8 7 x 0.3 39.2 0.6 1.2 13.2 189
12 7 x 0.3 39.2 0.6 1.2 15 252
0.5
16 7 x 0.3 39.2 0.6 1.2 16.7 318
20 7 x 0.3 39.2 0.6 1.3 18.7 387
24 7 x 0.3 39.2 0.6 1.3 20.6 452
30 7 x 0.3 39.2 0.6 1.5 23.3 640
26 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1 10.1 120
4 7 x 0.37 24.6 0.6 1 10.8 134
8 7 x 0.37 24.6 0.6 1.2 14.3 232
12 7 x 0.37 24.6 0.6 1.2 16.3 315
0.75
16 7 x 0.37 24.6 0.6 1.3 18.3 410
20 7 x 0.37 24.6 0.6 1.3 20.3 490
24 7 x 0.37 24.6 0.6 1.3 22.5 575
30 7 x 0.37 24.6 0.6 1.5 24.3 683
www.cncuxc.com 27
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen
TECHNICAL INFORMATION
Conductor Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs insulation
Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20°C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
28 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen
Application:
These cables are used in the chemical and petrochemical industries for the transmission of analogue and
TECHNICAL INFORMATION
Conductor Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs Max. DC Res. insulation
No.x dia. thickness overall diameter net weight
At 20°C thickness
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 1 10.3 118
4 7 x 0.3 39.2 0.6 1 11.1 136
8 7 x 0.3 39.2 0.6 1.2 14.7 234
12 7 x 0.3 39.2 0.6 1.3 17 325
0.5
16 7 x 0.3 39.2 0.6 1.3 18.9 413
20 7 x 0.3 39.2 0.6 1.3 21 495
24 7 x 0.3 39.2 0.6 1.5 23.7 606
30 7 x 0.3 39.2 0.6 1.5 26.3 822
www.cncuxc.com 29
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1 11.2 145
4 7 x 0.37 24.6 0.6 1 11.9 159
8 7 x 0.37 24.6 0.6 1.2 15.8 280
12 7 x 0.37 24.6 0.6 1.3 18.3 390
0.75
16 7 x 0.37 24.6 0.6 1.3 20.4 500
20 7 x 0.37 24.6 0.6 1.3 22.8 602
24 7 x 0.37 24.6 0.6 1.5 25.7 736
30 7 x 0.37 24.6 0.6 1.7 26.4 864
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
30 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
Conductor Nominal
Nominal sheath Approximate Approximate
Conductor size Number of pairs insulation
Max. DC Res. thickness overall diameter net weight
No.x dia. thickness
At 20°C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 31
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Collective Screen
Application:
These cables are used in the chemical and petrochemical industries for the transmission of
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate
Conductor size Max. DC Res. insulation
Triples No.x dia. thickness overall diameter net weight
At 20°C thickness
32 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
30 7 x 0.3 39.2 0.6 1.5 27.7 960
2 7 x 0.37 24.6 0.6 1 10.9 130
4 7 x 0.37 24.6 0.6 1 11.8 175
8 7 x 0.37 24.6 0.6 1.3 15.9 355
12 7 x 0.37 24.6 0.6 1.3 17.9 415
0.75
16 7 x 0.37 24.6 0.6 1.3 20.2 515
20 7 x 0.37 24.6 0.6 1.5 23.8 645
24 7 x 0.37 24.6 0.6 1.5 26 955
30 7 x 0.37 24.6 0.6 1.7 30 1150
www.cncuxc.com 33
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Collective Screen
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate
Conductor size Max. DC Res. insulation
Triples No.x dia. thickness overall diameter net weight
At 20°C thickness
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.43 18.4 0.6 1.2 12.1 160
4 7 x 0.43 18.4 0.6 1.2 13.6 240
8 7 x 0.43 18.4 0.6 1.3 17.6 420
12 7 x 0.43 18.4 0.6 1.3 20.3 570
1
16 7 x 0.43 18.4 0.6 1.3 22.8 730
20 7 x 0.43 18.4 0.6 1.5 25.6 900
24 7 x 0.43 18.4 0.6 1.5 27.6 1050
30 7 x 0.43 18.4 0.6 1.7 33.2 1295
2 7 x 0.49 14.2 0.6 1.2 12.8 190
4 7 x 0.49 14.2 0.6 1.3 14.4 275
8 7 x 0.49 14.2 0.6 1.3 18.8 485
12 7 x 0.49 14.2 0.6 1.3 21.7 685
1.3
16 7 x 0.49 14.2 0.6 1.5 25 910
20 7 x 0.49 14.2 0.6 1.5 27.4 1100
24 7 x 0.49 14.2 0.6 1.7 29.6 1300
30 7 x 0.49 14.2 0.6 2 35.6 1590
2 7 x 0.53 12.6 0.6 1.2 14 220
4 7 x 0.53 12.6 0.6 1.3 15.9 300
8 7 x 0.53 12.6 0.6 1.3 20.8 545
12 7 x 0.53 12.6 0.6 1.5 24.8 785
1.5
16 7 x 0.53 12.6 0.6 1.5 27.9 1100
20 7 x 0.53 12.6 0.6 1.7 30.7 1250
24 7 x 0.53 12.6 0.6 2 33.1 1460
30 7 x 0.53 12.6 0.6 2.2 37.3 1920
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
34 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Individual and Collective Screen
Application:
TECHNICAL INFORMATION
Conductor
Nominal
Number of Max. DC Nominal sheath Approximate Approximate net
Conductor size insulation
triples No.x dia. Res. At thickness overall diameter weight
thickness
20°C
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 1 11.7 145
4 7 x 0.3 39.2 0.6 1.2 13.2 195
8 7 x 0.3 39.2 0.6 1.3 17 320
12 7 x 0.3 39.2 0.6 1.3 19.6 430
0.5
16 7 x 0.3 39.2 0.6 1.3 22 560
20 7 x 0.3 39.2 0.6 1.5 24.7 680
24 7 x 0.3 39.2 0.6 1.5 26.6 800
30 7 x 0.3 39.2 0.6 1.7 29.2 1100
www.cncuxc.com 35
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1 12.5 160
4 7 x 0.37 24.6 0.6 1.2 14.1 220
8 7 x 0.37 24.6 0.6 1.3 18.3 380
12 7 x 0.37 24.6 0.6 1.3 21.1 530
0.75
16 7 x 0.37 24.6 0.6 1.5 24.2 690
20 7 x 0.37 24.6 0.6 1.7 26.7 845
24 7 x 0.37 24.6 0.6 1.7 28.8 1000
30 7 x 0.37 24.6 0.6 2 32.4 1300
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
36 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multitriples, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 37
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Single Pair, Collective Screen, Galvanized Steel Wire Armour
Application:
These cables are used in the chemical and petrochemical industries for the transmission
of analogue and digital signals for measurements and process control purposes, where
TECHNICAL INFORMATION
Conductor
Nominal Nominal Approximate
Conductor Number of Steel wire Approximate
Insulation Sheath Overall
Size Pairs diameter Net Weight
Max. DC Thickness thickness diameter
No. x dia
Res.At 20º
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
38 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Galvanized Steel
Wire Armour
TECHNICAL INFORMATION
Conductor Nominal Nominal Approximate
Conductor Number of Steel wire Approximate
insulation sheath overall
size pairs Max. DC diameter net weight
No.x dia. thickness thickness diameter
Res.At 20°C
mm2 No. No. x mm Ohm /Km mm mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 330
4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 370
8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 630
0.5 12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 770
16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 880
20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1170
24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1340
www.cncuxc.com 39
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1660
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 370
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 410
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 720
12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 880
0.75
16 7 x 0.37 24.6 0.6 1.6 1.7 27 1200
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1350
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1530
30 7 x 0.37 24.6 0.6 1.6 2 36.1 1730
40 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour
TECHNICAL INFORMATION
Conductor
Number Nominal Nominal Approximate Approximate
Conductor steel wire
of insulation sheath overall net
size Max. DC Res. diameter
pairs No.x dia. thickness thickness diameter weight
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm mm Kg/Km
mm
2 7 x 0.43 18.4 0.6 0.8 1.5 15.2 420
4 7 x 0.43 18.4 0.6 0.8 1.5 16.4 470
8 7 x 0.43 18.4 0.6 1.25 1.6 21.1 820
12 7 x 0.43 18.4 0.6 1.6 1.7 24.4 1170
1.0
16 7 x 0.43 18.4 0.6 1.6 1.7 26.4 1350
20 7 x 0.43 18.4 0.6 1.6 1.8 28.8 1530
24 7 x 0.43 18.4 0.6 1.6 1.9 31.8 1760
30 7 x 0.43 18.4 0.6 2 2.0 35.0 2390
2 7 x 0.49 14.2 0.6 0.8 1.5 15.6 430
4 7 x 0.49 14.2 0.6 1.25 1.5 18.1 600
8 7 x 0.49 14.2 0.6 1.25 1.6 22.2 860
12 7 x 0.49 14.2 0.6 1.6 1.7 25.3 1240
1.3
16 7 x 0.49 14.2 0.6 1.6 1.8 28.1 1460
20 7 x 0.49 14.2 0.6 1.6 1.8 30.4 1600
24 7 x 0.49 14.2 0.6 1.6 1.9 32.5 1900
30 7 x 0.49 14.2 0.6 2.0 2.0 35.9 2850
2 7 x 0.53 12.6 0.6 1.25 1.6 18.2 600
4 7 x 0.53 12.6 0.6 1.25 1.6 19.7 705
8 7 x 0.53 12.6 0.6 1.6 1.7 25.2 1190
12 7 x 0.53 12.6 0.6 1.6 1.8 28.1 1460
1.5
16 7 x 0.53 12.6 0.6 1.6 1.9 31.3 1800
20 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2090
24 7 x 0.53 12.6 0.6 2.0 2.0 38.3 2680
30 7 x 0.53 12.6 0.6 2.0 2.2 41.6 3220
www.cncuxc.com 41
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen,
TECHNICAL INFORMATION
Conductor
Number Nominal Nominal Approximate Approximate
Conductor steel wire
of insulation sheath overall net
size Max. DC Res. diameter
pairs No.x dia. thickness thickness diameter weight
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm mm Kg/Km
mm
42 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 315
4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 410
8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 690
12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 820
0.5
16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1160
20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1320
24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1580
30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 1930
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 355
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 450
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 755
12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1110
0.75
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1260
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1540
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1760
30 7 x 0.37 24.6 0.6 2 2.0 36.1 2470
www.cncuxc.com 43
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel
Wire Armour
TECHNICAL INFORMATION
Conductor
Nominal Nominal Approximate
Conductor Number of Steel wire Approximate
Insulation Sheath Overall
Size Pairs Max. DC Res. diameter Net Weight
No. x dia Thickness thickness diameter
At 20º
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
44 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multicores, Layers, Overall Screen of Tinned Copper WireBraid
Application:
Standard: Screen:
BS 5308-1 Collective screen of tinned copper wire braid with
Rated Voltage: coverage from 60% up to 80% and wrapped by
300/500 V polyester tapes
Conductor: Sheath:
Stranded annealed plain copper Polyvinylchloride TM1 to BS 6746 colour black or blue
Insulation: Minimum bending radius:
Polyethelene 03 to BS 6234 7.5x d (d= overall diameter)
Assembly: Temperature rating:
Cores twisted in concentric layers and +5oC up to + 50oC during operation
wrapped by polyester tapes Packing:
Colour code: On non-returnable wooden drums
Black continuously numbered
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate
Conductor size Max. DC Res. insulation
Cores No. x dia. thickness overall diameter net weight
At 20°C thickness
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.43 18.1 0.6 1.2 7.2 95
3 7 x 0.43 18.1 0.6 1.2 7.6 110
5 7 x 0.43 18.1 0.6 1.3 10.3 150
1 7 7 x 0.43 18.1 0.6 1.3 11.1 180
12 7 x 0.43 18.1 0.6 1.4 14.2 270
19 7 x 0.43 18.1 0.6 1.4 16.3 380
24 7 x 0.43 18.1 0.6 1.6 19.2 465
2 7 x 0.53 12.1 0.6 1.2 9 125
3 7 x 0.53 12.1 0.6 1.2 9.4 145
5 7 x 0.53 12.1 0.6 1.3 11.2 200
1.5 7 7 x 0.53 12.1 0.6 1.3 12 240
12 7 x 0.53 12.1 0.6 1.4 15.4 375
19 7 x 0.53 12.1 0.6 1.5 18 545
24 7 x 0.53 12.1 0.6 1.6 21 670
www.cncuxc.com 45
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Single Pair, Collective Screen of Tinned Copper Wire Braid
Application:
These cables are used in the chemical and petrochemical industries for the transmission of analogue
Standard: Screen:
BS 5308-1 Collective screen of aluminium polyester tapes and
Rated Voltage: tinned copper wire braid with coverage from 60% up
300/500 V to 80% and wrapped by polyester tapes
Conductor: Sheath:
Stranded annealed plain copper Polyvinylchloride TM1 to BS 6746 colour black or blue
Insulation: Minimum bending radius:
Polyethelene 03 to BS 6234 7.5 x d (d= overall diameter)
Assembly: Temperature rating:
Cores twisted to form a pair wrapped by +5oC up to + 50oC during operation
polyester tapes Packing:
Colour code: On non-returnable wooden drums
Black / White
TECHNICAL INFORMATION
Conductor
Nominal
Nominal sheath Approximate overall Approximate net
Conductor size insulation
Max. DC Res. thickness diameter weight
No.x dia. thickness
At 20°C
No. x
mm2 Ohm /Km mm mm mm Kg/Km
mm
1 X 2 X 0.5 7 x 0.3 39.2 0.6 0.8 6.3 40
1 X 2 X 0.75 7 x 0.7 24.6 0.6 0.8 6.6 46
1 X 2 X 1.0 7 x 0.43 18.4 0.6 0.8 7.0 53
1 X 2 X 1.3 7 x 0.49 14.2 0.6 0.9 7.6 65
1 X 2 X 1.5 7 x 0.53 12.6 0.6 0.9 8.2 73
46 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Overall Screen of Tinned Copper Wire Braid
Application:
These cables are used in the chemical and petrochemical industries for the transmission
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size insulation
pairs Max. DC Res. thickness overall diameter weight
No.x dia. thickness
At 20°C
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.3 39.2 0.6 1 9.3 95
4 7 x 0.3 39.2 0.6 1 10 115
6 7 x 0.3 39.2 0.6 1.2 12.3 175
0.5
8 7 x 0.3 39.2 0.6 1.2 13.2 190
10 7 x 0.3 39.2 0.6 1.2 14.5 220
12 7 x 0.3 39.2 0.6 1.2 15 250
2 7 x 0.37 24.6 0.6 1 10.1 120
4 7 x 0.37 24.6 0.6 1 10.8 134
6 7 x 0.37 24.6 0.6 1.2 13.8 220
0.75
8 7 x 0.37 24.6 0.6 1.2 14.3 230
10 7 x 0.37 24.6 0.6 1.2 15.8 275
12 7 x 0.37 24.6 0.6 1.2 16.3 320
www.cncuxc.com 47
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Overall Screen of Plain or Tinned Copper Wire
Braid
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.43 18.4 0.6 1.0 10.8 135
4 7 x 0.43 18.4 0.6 1.0 11.6 160
6 7 x 0.43 18.4 0.6 1.2 12.8 255
1.0
8 7 x 0.43 18.4 0.6 1.2 15.4 280
10 7 x 0.43 18.4 0.6 1.3 17.2 345
12 7 x 0.43 18.4 0.6 1.3 17.8 400
2 7 x 0.49 14.2 0.6 1.0 11.4 165
4 7 x 0.49 14.2 0.6 1.2 13.5 195
6 7 x 0.49 14.2 0.6 1.3 14.7 260
1.3
8 7 x 0.49 14.2 0.6 1.3 16.6 340
10 7 x 0.49 14.2 0.6 1.3 18.1 410
12 7 x 0.49 14.2 0.6 1.3 20.2 480
2 7 x 0.53 12.6 0.6 1.2 12.9 195
4 7 x 0.53 12.6 0.6 1.2 14.1 230
6 7 x 0.53 12.6 0.6 1.3 17.8 390
1.5
8 7 x 0.53 12.6 0.6 1.3 18.6 405
10 7 x 0.53 12.6 0.6 1.3 20.6 490
12 7 x 0.53 12.6 0.6 1.3 21.3 564
48 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multicores, Layers, Collective Screen, Stranded Conductor
Application:
These cables are used in fire fighting alarm systems in hazardous area where the safety is highly required
during fire condition.
Engineering Specification:
Resistant Cables
Standard: Colour code:
IEC 60502 Black continuously numbered
Rated Voltage: Screen:
600 / 1000 V Collective screen of aluminum polyester tapes
Conductor: with tinned drain wire and wrapped by polyester
Stranded plain / tinned annealed tapes
copper Sheath:
Insulation: Halogen free, low smoke thermoplastic material,
Flame barrier mica tape, cross-linked red colour
polyethylene Minimum bending radius:
Assembly: 7.5 x d (d= overall diameter)
Cores twisted together in concentric Fire resistant property:
layers and wrapped by polyester tapes 750oC according to IEC 331
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.52 12.1 0.7 1.8 10.5 115
5 7 x 0.52 12.1 0.7 1.8 12.8 204
7 7 x 0.52 12.1 0.7 1.8 13.8 212
10 7 x 0.52 12.1 0.7 1.8 17.2 352
1.5
12 7 x 0.52 12.1 0.7 1.8 17.8 402
19 7 x 0.52 12.1 0.7 1.8 20.6 582
24 7 x 0.52 12.1 0.7 1.8 23.9 720
30 7 x 0.52 12.1 0.7 1.8 25.3 870
www.cncuxc.com 49
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
37 7 x 0.52 12.1 0.7 1.8 27.3 1040
2 7 x 0.67 7.41 0.7 1.8 11.4 146
5 7 x 0.67 7.41 0.7 1.8 14.1 260
7 7 x 0.67 7.41 0.7 1.8 15.2 325
10 7 x 0.67 7.41 0.7 1.8 19.0 435
2.5 12 7 x 0.67 7.41 0.7 1.8 19.6 500
19 7 x 0.67 7.41 0.7 1.8 22.8 700
24 7 x 0.67 7.41 0.7 1.8 26.6 860
30 7 x 0.67 7.41 0.7 1.9 28.4 1040
37 7 x 0.67 7.41 0.7 1.9 30.1 1250
50 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Stranded Conductor
Application:
These cables are used in fire fighting alarm systems in hazardous area where the safety is highly
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.3 39.2 0.6 1.2 11.1 98
4 7 x 0.3 39.2 0.6 1.2 12.8 145
6 7 x 0.3 39.2 0.6 1.2 15.3 200
8 7 x 0.3 39.2 0.6 1.3 17.0 270
10 7 x 0.3 39.2 0.6 1.3 18.8 310
0.5
12 7 x 0.3 39.2 0.6 1.4 19.9 355
16 7 x 0.3 39.2 0.6 1.4 22.5 454
20 7 x 0.3 39.2 0.6 1.5 25.0 560
24 7 x 0.3 39.2 0.6 1.5 27.1 650
30 7 x 0.3 39.2 0.6 1.6 30.1 800
www.cncuxc.com 51
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.37 24.6 0.6 1.2 11.8 110
4 7 x 0.37 24.6 0.6 1.2 13.7 175
6 7 x 0.37 24.6 0.6 1.3 16.6 245
8 7 x 0.37 24.6 0.6 1.3 17.7 305
10 7 x 0.37 24.6 0.6 1.3 20.1 370
0.75
12 7 x 0.37 24.6 0.6 1.4 21.3 435
16 7 x 0.37 24.6 0.6 1.4 24.1 555
20 7 x 0.37 24.6 0.6 1.5 26.8 685
24 7 x 0.37 24.6 0.6 1.5 29.1 800
30 7 x 0.37 24.6 0.6 1.6 32.3 990
52 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Stranded Conductor
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size insulation
pairs Max. DC thickness overall diameter weight
No.x dia. thickness
Res.At 20°C
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
2 7 x 0.43 18.4 0.6 1.2 13.1 142
4 7 x 0.43 18.4 0.6 1.3 15.5 230
6 7 x 0.43 18.4 0.6 1.3 18.6 325
8 7 x 0.43 18.4 0.6 1.3 19.8 405
10 7 x 0.43 18.4 0.6 1.3 22.6 490
1
12 7 x 0.43 18.4 0.6 1.4 23.9 585
16 7 x 0.43 18.4 0.6 1.5 27.4 760
20 7 x 0.43 18.4 0.6 1.6 30.4 940
24 7 x 0.43 18.4 0.6 1.6 33 1100
30 7 x 0.43 18.4 0.6 1.7 36.7 1360
2 7 x 0.53 12.6 0.6 1.2 14 166
4 7 x 0.53 12.6 0.6 1.3 16.7 286
6 7 x 0.53 12.6 0.6 1.3 20.1 400
8 7 x 0.53 12.6 0.6 1.3 21.5 505
10 7 x 0.53 12.6 0.6 1.3 24.5 620
1.5
12 7 x 0.53 12.6 0.6 1.4 26 735
16 7 x 0.53 12.6 0.6 1.5 29.7 960
20 7 x 0.53 12.6 0.6 1.6 33 1185
24 7 x 0.53 12.6 0.6 1.7 36.1 1410
30 7 x 0.53 12.6 0.6 1.7 40 1725
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
• We can meet all other standard as BS 5308 and IEC 502.
www.cncuxc.com 53
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen, Stranded
Conductor
Application:
These cables are used in fire fighting alarm systems in hazardous area where the safety is highly
required during fire condition.
Engineering Specification:
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
54 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 7 x 0.3 39.2 0.6 1.2 11.8 110
4 7 x 0.3 39.2 0.6 1.2 13.7 170
6 7 x 0.3 39.2 0.6 1.2 16.4 234
8 7 x 0.3 39.2 0.6 1.3 17.7 296
10 7 x 0.3 39.2 0.6 1.3 20.1 360
0.5
12 7 x 0.3 39.2 0.6 1.4 21.3 425
16 7 x 0.3 39.2 0.6 1.4 24.1 540
20 7 x 0.3 39.2 0.6 1.5 26.8 670
24 7 x 0.3 39.2 0.6 1.5 29.1 780
30 7 x 0.3 39.2 0.6 1.6 32.3 960
2 7 x 0.37 24.6 0.6 1.2 12.5 126
4 7 x 0.37 24.6 0.6 1.2 14.5 200
6 7 x 0.37 24.6 0.6 1.3 17.7 285
8 7 x 0.37 24.6 0.6 1.3 18.8 350
10 7 x 0.37 24.6 0.6 1.3 21.5 430
0.75
12 7 x 0.37 24.6 0.6 1.4 22.7 505
16 7 x 0.37 24.6 0.6 1.4 25.8 650
20 7 x 0.37 24.6 0.6 1.5 28.7 800
24 7 x 0.37 24.6 0.6 1.5 31.1 935
30 7 x 0.37 24.6 0.6 1.6 34.6 1155
www.cncuxc.com 55
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Individual and Collective Screen, Stranded
Conductor
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.43 18.4 0.6 1.2 13.1 142
4 7 x 0.43 18.4 0.6 1.3 15.5 230
6 7 x 0.43 18.4 0.6 1.3 18.6 325
8 7 x 0.43 18.4 0.6 1.3 19.8 405
10 7 x 0.43 18.4 0.6 1.3 22.6 490
1
12 7 x 0.43 18.4 0.6 1.4 23.9 585
16 7 x 0.43 18.4 0.6 1.5 27.4 760
20 7 x 0.43 18.4 0.6 1.6 30.4 940
24 7 x 0.43 18.4 0.6 1.6 33.0 1100
30 7 x 0.43 18.4 0.6 1.7 36.7 1360
2 7 x 0.53 12.6 0.6 1.2 14.0 166
4 7 x 0.53 12.6 0.6 1.3 16.7 286
6 7 x 0.53 12.6 0.6 1.3 20.1 400
8 7 x 0.53 12.6 0.6 1.3 21.5 505
10 7 x 0.53 12.6 0.6 1.3 24.5 620
1.5
12 7 x 0.53 12.6 0.6 1.4 26.0 735
16 7 x 0.53 12.6 0.6 1.5 29.7 960
20 7 x 0.53 12.6 0.6 1.6 33.0 1185
24 7 x 0.53 12.6 0.6 1.7 36.1 1410
30 7 x 0.53 12.6 0.6 1.7 40.0 1725
56 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multicores, Unscreened, Stranded Conductor
Application:
TECHNICAL INFORMATION
Conductor
Number Nominal
Nominal sheath Approximate Approximate net
Conductor size of insulation
Max. DC Res. thickness overall diameter weight
pairs No.x dia. thickness
At 20°C
No. x
mm2 No. Ohm /Km mm mm mm Kg/Km
mm
2 7 x 0.43 18.1 0.6 0.8 6.6 65
1.0 3 7 x 0.43 18.1 0.6 0.8 7.0 79
4 7 x 0.43 18.1 0.6 0.8 7.6 98
2 7 x 0.52 12.1 0.6 0.8 7.1 81
3 7 x 0.52 12.1 0.6 0.9 7.8 103
4 7 x 0.52 12.1 0.6 0.9 8.5 128
www.cncuxc.com 57
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Stranded Conductor
Application:
These cables are used for communication and signaling in fire alarm systems.
Engineering Specification:
TECHNICAL INFORMATION
Conductor
Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC Res. insulation
pairs thickness overall diameter weight
No.x dia. At thickness
20°C
mm2 No. No. xmm Ohm /Km mm mm mm Kg/Km
2 7 x 0.53 12.6 0.6 1.2 12 155
4 7 x 0.53 12.6 0.6 1.2 14 253
8 7 x 0.53 12.6 0.6 1.3 18.1 457
12 7 x 0.53 12.6 0.6 1.3 21.6 652
1.5
16 7 x 0.53 12.6 0.6 1.5 24.7 860
20 7 x 0.53 12.6 0.6 1.5 27.5 1058
24 7 x 0.53 12.6 0.6 1.7 30.2 1270
30 7 x 0.53 12.6 0.6 2 33.9 1600
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
58 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multicores, Unscreened, Solid Conductor
Application:
TECHNICAL INFORMATION
Conductor Nominal Nominal
Number of Approximate Approximate net
Conductor Size Max.dc Resis. Insulation Theath
Cores No.x Dia overall Diameter Weight
At 20C thickness Thickness
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 59
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Solid Conductor
Application:
These cables are used for communication and signaling in fire alarm systems.
Engineering Specification:
TECHNICAL INFORMATION
Conductor Nominal Nominal
Number of Approximate Approximate net
Conductor Size Max.dc Resis. Insulation Theath
Pairs No. x Dia overall Diameter Weight
At 20C thickness Thickness
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
60 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multicores, Unscreened, Flexible Conductor
Application:
TECHNICAL INFORMATION
Conductor Nominal Nominal
Number of Approximate Approximate net
Conductor Size Insulation Theath
Cores Max.dc Resis. overall Diameter Weight
No.x Dia thickness Thickness
At 20C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 61
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Multipairs, Layers, Collective Screen, Flexible Conductor
Application:
These cables are used for communication and signaling in fire alarm systems.
TECHNICAL INFORMATION
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
62 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, PVC Sheathed
Application:
For outdoor and indoor installations in damp and wet locations, connecting signaling and control units
in industry, in railways, in traffic signals, in thermopower and hydropower stations. They are laid in air, in ducts,
in trenches, in steel support brackets or direct in ground, when well protected.
Engineering Specification:
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC Res. insulation
cores No.x dia.No. x thickness overall diameter weight
At 20oC thickness
mm2 No. mm Ohm /Km mm mm mm Kg/Km
5 1x1.38 12.1 0.8 1.8 11.8 200
7 1x1.38 12.1 0.8 1.8 12.7 250
10 1x1.38 12.1 0.8 1.8 15.7 340
12 1x1.38 12.1 0.8 1.8 16.2 385
14 1x1.38 12.1 0.8 1.8 17 435
1.5 16 1x1.38 12.1 0.8 1.8 17.8 490
19 1x1.38 12.1 0.8 1.8 18.7 560
24 1x1.38 12.1 0.8 1.8 21.7 700
30 1x1.38 12.1 0.8 1.8 23.8 850
37 1x1.38 12.1 0.8 1.8 24.7 1000
44 1x1.38 12.1 0.8 1.8 28.4 1200
www.cncuxc.com 63
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, PVC Sheathed
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC Res. insulation
Cores No.x dia. thickness overall diameter weight
At 20°C thickness
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
5 1x1.78 7.41 0.8 1.8 12.9 260
7 1x1.78 7.41 0.8 1.8 13.8 330
10 1x1.78 7.41 0.8 1.8 17.2 450
12 1x1.78 7.41 0.8 1.8 17.7 540
14 1x1.78 7.41 0.8 1.8 18.6 600
2.5 16 1x1.78 7.41 0.8 1.8 19.6 670
19 1x1.78 7.41 0.8 1.8 20.6 780
24 1x1.78 7.41 0.8 1.8 24 1030
30 1x1.78 7.41 0.8 1.8 25.4 1160
37 1x1.78 7.41 0.8 1.9 27.4 1410
44 1x1.78 7.41 0.8 2 31.2 1670
5 1x2.26 4.61 1 1.8 15.3 430
7 1x2.26 4.61 1 1.8 16.5 480
10 1x2.26 4.61 1 1.8 20.8 670
12 1x2.26 4.61 1 1.8 21.5 780
14 1x2.26 4.61 1 1.8 22.6 890
4
16 1x2.26 4.61 1 1.8 23.8 1000
19 1x2.26 4.61 1 1.9 25.1 1170
24 1x2.26 4.61 1 2 29.6 1460
30 1x2.26 4.61 1 2.1 31.6 1830
37 1x2.26 4.61 1 2.2 34.1 2320
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
64 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Copper Tape Screened, PVC Sheathed
Application:
For outdoor installations in damp and wet locations, connecting signaling and control units in
industry in railways, in traffic signals, in thermopower and hydropower stations. Where electrical
interference could alter signal transmission, They are laid in air, in ducts, in trenches, in steel
support brackets or direct in ground, when well protected.
Engineering Specification:
Standard: green yellow core
IEC – 60502 Bedding:
Rated Voltage: Polyvinylchoride rated 70oC
600 / 1000 V Screen :
Conductor: Copper tape helically applied over the bedding
Soft annealed stranded copper wire as per Sheath:
class 2 of IEC 228 Flame retardant polyvinylchloride, black or grey
Insulation: colour
Polyvinylchloride rated 70oC or 85oC Minimum bending radius:
Assembly: 15 x d (d= overall diameter)
Cores twisted together to form a round Temperature rating:
assembly cable with fillers whenever +5oC up to + 50oC during operation
necessary Packing:
Colour code: On non-returnable wooden drum
Black cores with white numbers and one
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC insulation
Cores No.x dia. thickness overall diameter weight
Res.At 20oC thickness
www.cncuxc.com 65
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Copper Tape Screened, PVC Sheathed
TECHNICAL INFORMATION
Conductor
Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC insulation
Cores No.x dia. thickness overall diameter weight
Res.At 20oC thickness
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
66 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Tape Armoured, PVC Sheathed
Application:
For outdoor and indoor installations in damp and wet locations, Laid Direct in the ground, where
mechanical damages are expected to occur. They are normally used in connecting signaling
and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations.
Engineering Specification:
Standard: green yellow core
IEC – 60502 Bedding:
Rated Voltage: Polyvinylchoride rated 70ºC
600 / 1000 V Armouring:
Conductor: Double layers of steel tapes are applied helically
Soft annealed Stranded Copper wire as per Sheath:
class 2 of IEC 228 Flame retardant polyvinylchloride, black or grey
Insulation: colour
Polyvinylchloride rated 70oC or 85oC Minimum bending radius:
Assembly: 15 x d (d= overall diameter)
Cores twisted together to form a round Temperature rating:
assembly cable with fillers whenever +5oC up to + 50oC during operation
necessary Packing:
Colour code: On non-returnable wooden drums
Black cores with white numbers and one
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size insulation
cores Max. DC thickness overall diameter weight
No.x dia. thickness
Res.At 20°C
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
5 7x 0.52 12.1 0.8 1.8 15.3 340
7 7x 0.52 12.1 0.8 1.8 15.7 370
10 7x 0.52 12.1 0.8 1.8 18.9 495
12 7x 0.52 12.1 0.8 1.8 19.4 550
14 7x 0.52 12.1 0.8 1.8 20.2 610
1.5 16 7x 0.52 12.1 0.8 1.8 21.1 670
19 7x 0.52 12.1 0.8 1.8 22.1 760
24 7x 0.52 12.1 0.8 1.8 25.3 930
30 7x 0.52 12.1 0.8 1.8 27.5 1115
37 7x 0.52 12.1 0.8 1.9 28.5 1290
44 7x 0.52 12.1 0.8 2 31 1500
www.cncuxc.com 67
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Tape Armoured, PVC Sheathed
TECHNICAL INFORMATION
Conductor Nominal
Number of Nominal sheath Approximate Approximate net
Conductor size Max. DC Res. insulation
Cores No.x dia. thickness overall diameter weight
At 20oC thickness
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
68 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Wire Armoured, PVC Sheathed
Application:
For outdoor and indoor installations in damp and wet locations, laid direct in the ground, where mechanical
damages are expected to occur. They are normally used in connecting signaling and control units in industry,
in railways, in traffic signals, in thermopower and hydropower stations.
Engineering Specification:
Standard: green yellow core
IEC – 60502 Bedding:
Rated Voltage: Polyvinylchoride rated 70oC
600 / 1000 V Armouring:
Conductor: Single layers of steel wire are applied helically
Soft annealed stranded copper wire as per Sheath:
class 2 of IEC 228 Flame retardant polyvinylchloride, black or
Insulation: grey colour
Polyvinylchloride rated 70oC or 85oC Minimum bending radius:
Assembly: 15 x d (d= overall diameter)
Cores twisted together to form a round Temperature rating:
assembly cable with fillers whenever +5oC up to + 50oC during operation
necessary Packing:
Colour code: On non-returnable wooden drums
Black cores with white numbers and one
TECHNICAL INFORMATION
Conductor Nominal Nominal Nominal Approximate
Conductor Number of Approximate
insulation Thickness of sheath overall
size Cores Max. DC Res. net weight
No.x dia. thickness Steel tape thickness diameter
At 20°C
www.cncuxc.com 69
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Wire Armoured, PVC Sheathed
TECHNICAL INFORMATION
Conductor Nominal Nominal Nominal Approximate
Number of Approximate
Conductor size Max. DC Res. insulation Thickness of sheath overall
Cores No.x dia. net weight
At 20oC thickness Steel tape thickness diameter
mm2 No. No. x mm Ohm /Km mm mm mm mm Kg/Km
5 7x 0.67 7.41 0.8 0.2 1.8 16.2 440
7 7x 0.67 7.41 0.8 0.2 1.8 17.3 530
10 7x 0.67 7.41 0.8 0.2 1.8 20.9 710
12 7x 0.67 7.41 0.8 0.2 1.8 21.5 790
14 7x 0.67 7.41 0.8 0.2 1.8 22.4 880
2.5 16 7x 0.67 7.41 0.8 0.2 1.8 23.4 970
19 7x 0.67 7.41 0.8 0.2 1.8 24.5 1090
24 7x 0.67 7.41 0.8 0.2 1.8 28.1 1140
30 7x 0.67 7.41 0.8 0.2 1.9 27.3 1630
37 7x 0.67 7.41 0.8 0.2 1.9 31.9 1875
44 7x 0.67 7.41 0.8 0.5 2.1 36 2500
5 7x 0.85 4.61 0.8 0.2 1.8 18.9 660
7 7x 0.85 4.61 0.8 0.2 1.8 20.3 740
10 7x 0.85 4.61 0.8 0.2 1.8 24.9 960
12 7x 0.85 4.61 0.8 0.2 1.8 25.6 1120
14 7x 0.85 4.61 0.8 0.2 1.8 26.7 1270
4
16 7x 0.85 4.61 0.8 0.2 1.8 28 1390
19 7x 0.85 4.61 0.8 0.2 1.8 29.4 1610
24 7x 0.85 4.61 0.8 0.2 2 34.4 2030
30 7x 0.85 4.61 0.8 0.2 2.1 36.5 2660
37 7x 0.85 4.61 0.8 0.5 2.2 39.4 3250
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
70 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Wire Armoured, PVC Sheathed
Application:
For outdoor and indoor installations in damp and wet locations, laid direct in the ground, where mechanical
damages are expected to occur. They are normally used in connecting signaling and control units in industry,
in railways, in traffic signals, in thermopower and hydropower stations.
Engineering Specification:
TECHNICAL INFORMATION
Conductor Nominal Nominal Nominal Approximate
Conductor Number of Approximate
Max. DC Res. insulation Diameter of sheath overall
size Cores No.x dia. net weight
At 20°C thickness steel wire thickness diameter
www.cncuxc.com 71
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation, Steel Wire Armoured, PVC Sheathed
TECHNICAL INFORMATION
Conductor
Nominal Nominal Nominal Approximate
Conductor Number of Approximate
insulation Diameter of sheath overall
size Cores net weight
Max. DC Res. thickness steel wire thickness diameter
No.x dia.
At 20°C
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
72 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Data Cable – Category 5e
Application:
The cable is used for Local Area Computer Networks mainly in office or business environments.
Type: Sheath:
UTP- Cat 5e Flame retardant PVC Grey RAL 7032, 5.86mm
Standard: nominal diameter
TIA / EIA 568 A, ISO / IEC 11801 Pair Colours:
Conductor: One Pair : blue & white / blue
24 AWG (0.528mm) solid bare conductor Two Pairs : orange & white / orange
Insulation: Three Pairs : green & white / green
Solid polyethylene, diameter 0.95mm Four Pairs : brown & white / brown
Pairs: Bending radius:
2 insulated conductors twisted together, Lay 8 x O.D during installation
varied to minimize crosstalk Temperature range during operation:
Assembly: +5oC up to + 50oC
4 pairs twisted together
ELECTRICAL CHARACTERISTICS
Minimum Structural
Characteristic impedance Maximum Attenuation Near End Cross talk
Frequency (MHz) Return Loss (dB) at
(ohms) ( dB /100m @ 20oC ) Minimum
100mm
www.cncuxc.com 73
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Data Cable – Category 5e
Application:
The cable is used for Local Area Computer Networks mainly in electrically noisy office or
industrial environments.
Type: Screen:
STP- Cat 5e Aluminium polyester tape and 0.5mm plain
Standard: or tinned copper drain wire
TIA/ EIA 568 A, ISO / IEC 11801 Pair Colours:
Conductor: One Pair : blue & white / blue
24 AWG (0.528mm) solid bare conductor Two Pairs : orange & white / orange
Insulation: Three Pairs : green & white / green
Solid polyethylene, diameter 1.09mm Four Pairs : brown & white / brown
Pairs: Bending radius:
2 insulated conductors twisted together, lay 8 x O.D during installation
varied to minimize crosstalk Temperature range during operation:
Assembly: +5oC up to + 50
4 pairs twisted together
ELECTRICAL CHARACTERISTICS
0.772 - 1.8 64 -
1 100 ± 15% 2 62 23
4 100 ± 15% 4.1 53 23
10 100 ± 15% 6.5 47 23
16 100 ± 15% 8.2 44 23
20 100 ± 15% 9.2 42 23
31.25 100 ± 15% 11.7 39 21
62.5 100 ± 15% 17 35 18
100 100 ± 15% 22 32 16
125 100 ± 15% 25 32 16
Pakaging
Available in easy – pull boxes of 1000 feet (305m) capacity.
This assures the cable will not be damaged during installation due to
the “figure 8” internal coiling. It also enables easy, tidy storage before and during installation.
74 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Data Cable – Category 6
Application:
Type: Sheath:
UTP- Cat 6 Flame retardant PVC Grey RAL 7032, 5.94mm
Standard: nominal diameter
TIA/ EIA 568 A, ISO / IEC 11801 Pair Colours:
Conductor: One Pair : blue & white / blue
24 AWG (0.54mm) solid bare conductor Two Pairs : orange & white / orange
Insulation: Three Pairs : green & white / green
Solid polyethylene, diameter 0.97mm Four Pairs : brown & white / brown
Pairs: Bending radius:
2 insulated conductors twisted together, Lay 8 x O.D during installation
varied to minimize crosstalk Temperature range during operation:
Assembly: +5oC up to + 50ohC
4 pairs twisted together
ELECTRICAL CHARACTERISTICS
Characteristic Maximum Minimum
Frequency Near End Cross
impedance Attenuation Structural Return Loss
(MHz) talk Minimum
(ohms) ( dB /100m @ 20℃ ) (dB) at 100mm
www.cncuxc.com 75
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulated Multipairs
Application:
The cable is used for Indoor installation and interconnection of Transmission, Telephone, Telegraph
and Electronic equipment.
Engineering Specification:
Standard:
IEC-189 & TC-113
Conductor:
Solid, plain / tinned copper.
Insulation:
PVC rated 70oC as per IEC 189.2
Assembly:
Telephone Cable
Cores are twisted into pairs and pairs twisted
together to form a cable core
Sheath:
Polyvinylchloride as per IEC 189-2 and rip
cord is provided under the sheath for easy
stripping
Temperature rating:
+5ºC to +50ºC during operation
Colour of
No. of Pairs A Wire B Wire No. of Pairs A Wire B Wire Unit No.
Bindings
76 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulated Multipairs
TECHNICAL INFORMATION
Conductor Nominal Nominal
Number of Approximate overall Approximate net
Conductor size Max. DC insulation sheath
pairs No.x dia. diameter weight
Res. At 20℃ thickness thickness
www.cncuxc.com 77
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
40 1x0.5 97.8 0.15 0.9 14.9 280
50 1x0.5 97.8 0.15 0.9 16.5 340
60 1x0.5 97.8 0.15 0.9 17.9 400
80 1x0.5 97.8 0.15 1 20.5 520
100 1x0.5 97.8 0.15 1 22.7 640
200 1x0.5 97.8 0.15 1.5 30.6 1350
300 1x0.5 97.8 0.15 1.6 37 2000
TECHNICAL INFORMATION
Conductor
Nominal Nominal
Number of Max. DC Approximate overall Approximate net
Conductor size insulation sheath
pairs No.x dia. Res. At diameter weight
thickness thickness
20℃
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km
1 1x0.6 67.9 0.15 0.6 3.6 19
2 1x0.6 67.9 0.15 0.6 5.1 31
3 1x0.6 67.9 0.15 0.6 5.2 38
4 1x0.6 67.9 0.15 0.6 5.8 47
5 1x0.6 67.9 0.15 0.6 6.4 57
6 1x0.6 67.9 0.15 0.7 7.1 69
7 1x0.6 67.9 0.15 0.7 8.7 77
10 1x0.6 67.9 0.15 0.7 10.5 103
15 1x0.6 67.9 0.15 0.8 12 150
20 1x0.6 67.9 0.15 0.9 13.2 195
0.6
25 1x0.6 67.9 0.15 0.9 14.3 235
30 1x0.6 67.9 0.15 0.9 16.2 275
40 1x0.6 67.9 0.15 0.9 17.9 355
50 1x0.6 67.9 0.15 0.9 19.6 430
60 1x0.6 67.9 0.15 1 22.3 515
80 1x0.6 67.9 0.15 1 25.1 670
100 1x0.6 67.9 0.15 1.2 26 845
150 1x0.6 67.9 0.15 1.4 26.7 1240
200 1x0.6 67.9 0.15 1.5 30.71 1260
250 1x0.6 67.9 0.15 1.6 34 2000
0.8 1 1x0.8 37.5 0.25 0.7 6.4 30
78 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
2 1x0.8 37.5 0.25 0.7 6.5 50
3 1x0.8 37.5 0.25 0.7 7.3 62
4 1x0.8 37.5 0.25 0.7 7.9 78
5 1x0.8 37.5 0.25 0.7 9 91
6 1x0.8 37.5 0.25 0.9 9.5 115
7 1x0.8 37.5 0.25 0.9 11 128
10 1x0.8 37.5 0.25 0.9 13.1 171
15 1x0.8 37.5 0.25 0.9 14.8 240
20 1x0.8 37.5 0.25 0.9 16.5 310
25 1x0.8 37.5 0.25 1 17.9 385
30 1x0.8 37.5 0.25 1 20.3 450
40 1x0.8 37.5 0.25 1 22.9 580
50 1x0.8 37.5 0.25 1.2 24.8 735
60 1x0.8 37.5 0.25 1.2 28.7 865
80 1x0.8 37.5 0.25 1.4 31.7 1150
100 1x0.8 37.5 0.25 1.4 32.5 1410
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 79
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
MATV Cables
Application:
TV patented coaxial cables for satellite and digital installations.
Engineering Specification:
TECHNICAL INFORMATION
Type: RG - 59 / U MATV
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Diameter Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
0.81 3.71 100% Al /PET 6.16 75 + 2% 53 82 100 8.2
Tape + 40% 200 11.5
T. CU braid 400 16.1
700 21.3
Type: RG - 11 / U MATV
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Diameter Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
1.63 7.25 100% Al /PET 10.3 75 + 2% 53 82 100 3.9
Tape + 40% 200 5.6
T. CU braid 400 7.9
700 11.5
80 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
MATV Cables
TECHNICAL INFORMATION
Type: RG - 6 / U MATV
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Diameter Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
1.02 4.59 100% Al /PET 7 75 + 2% 53 82 100 6.6
Tape + 40% 200 9.2
T. CU braid 400 13.1
700 17.4
Type: CF -160 MATV
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Diameter Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
1.14 5.1 100% Al /PET 7 75 + 2% 53 82 100 6
Tape + 70% 300 9
T. CU braid 500 13
800 16
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 81
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
RG Cables
Application:
Cables used for transmitting and receiving high frequency signals in
radio frequency devices and connections.
Engineering Specification:
Conductor:
TECHNICAL INFORMATION
Type: RG - 58 / U
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Mat. /Const. Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
82 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
RG Cables
Type: RG -216
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Mat. /Const. Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
CU / 7 x 0.4 7.25 95% 10.8 75 + 2% 67.3 66 100 6.6
2 CU braid 200 9.5
400 13.8
700 19
Type: RG - 8 / U
Nominal
Conductor Insulation Shield type & Outer Nominal Nominal Nominal Attenuation
Velocity of
Mat. /Const. Diameter Coverage Diameter Impedance Capacitance At 20oC
Propag.
mm mm % mm Ohms PF / m % MHz dB / 100 m
CU / 7 x 0.74 7.16 97% 10.29 52 + 2% 96.8 66 100 6.2
CU braid 200 8.9
400 13.4
700 26.2
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 83
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Insulation
Application:
This wire is used in the manufacture of electrical harnesses for cars and other
automotive products.
Engineering Specification:
Conductor:
Soft annealed stranded fine wires according to DIN ISO 6722, part 3
Insulation:
Polyvinylchloride, according to DIN ISO 6722, part 2, class A
Colour coding :
Two colours are marked by two diametrically opposed longitudinal stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-40oC up to + to 90 oC
TECHNICAL INFORMATION
Conductor
Nominal insulation Approximate Approximate net
Conductor size
Max. DC Res. At thickness overall diameter weight
No.x dia. Approx. Diameter
20
mm2 No. x mm mm Ohm /Km mm mm Kg/Km
0.5 16 x 0.21 1 37.1 0.6 2.2 9
0.75 24 x 0.21 1.2 24.7 0.6 2.4 12
1 32 x 0.21 1.35 18.5 0.6 2.6 15
1.5 30 x 0.26 1.7 12.7 0.6 2.9 20
2 40 x 0.26 2 9.42 0.6 3.2 26
2.5 50 x 0.26 2.2 7.6 0.7 3.6 32
3 60 x 0.26 2.5 6 0.7 3.9 37
4 56 x 0.31 2.75 4.71 0.8 4.4 49
6 84 x 0.31 3.3 3.14 0.8 4.9 68
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
84 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Heat – Resistant PVC Insulation
Application:
This wire is used in the manufacture of electrical harnesses for cars and other
automotive products.
Engineering Specification:
Conductor:
Soft annealed stranded fine wires according to DIN ISO 6722, part 3
Insulation:
Heat – resistant polyvinylchloride, according to DIN ISO 6722, part 2, class B
Colour coding :
Two colours are marked by two diametrically opposed longitudinal stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-40oC up to + to 105 oC
TECHNICAL INFORMATION
Conductor
Nominal
Approximate overall Approximate net
Conductor size insulation
diameter weight
Approx. Max. DC Res. thickness
No.x dia.
Diameter At 20
www.cncuxc.com 85
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Heat – Pressure Resistant PVC Insulation
Application:
This wire is used in the manufacture of electrical harness for cars
and other automotive products.
Engineering Specification:
Conductor:
Soft annealed stranded fine wires according to DIN ISO 6722, part 3
Insulation:
Heat – resistant polyvinylchloride, according to DIN ISO 6722, part 2
class B
(hot pressure resistance test at 120oC)
Colour coding :
Two colours are marked by two diametrically opposed longitudinal
stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-20oC up to + to 125 oC
TECHNICAL INFORMATION
Conductor
Nominal insulation Approximate Approximate net
Conductor size
Max. DC Res. At thickness overall diameter weight
No.x dia. Approx. Diameter
20℃
mm2 No. x mm mm Ohm /Km mm mm Kg/Km
0.5 16 x 0.21 1 37.1 0.6 2.2 9
0.75 24 x 0.21 1.2 24.7 0.6 2.4 11
1 32 x 0.21 1.35 18.5 0.6 2.6 14
1.5 30 x 0.26 1.7 12.7 0.6 2.9 19
2.5 50 x 0.26 2.2 7.6 0.7 3.6 30
3 60 x 0.26 2.5 6.21 0.7 3.9 36
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
86 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Cold – Resistant PVC Insulation
Application:
This wire is used in the manufacture of electrical harness for cars
and other automotive products.
Engineering Specification:
Conductor:
Soft annealed stranded super fine wires
Insulation:
Cold- resistant polyvinylchloride, according to DIN ISO 6722, part 2,
class A.
(Cold pressure resistance test at 120oC)
Colour coding :
Two colours are marked by two diametrically opposed longitudinal
stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-40oC up to + to 90 oC
TECHNICAL INFORMATION
Conductor
Nominal insulation Approximate Approximate net
Conductor size
Max. DC Res. At thickness overall diameter weight
No.x dia. Approx. Diameter
20℃
mm2 No. x mm Mm Ohm /Km mm mm Kg/Km
0.5 28 x 0.16 1.1 37.7 0.6 2.3 9
0.75 24 x 0.16 1.3 25.1 0.6 2.5 12
1 57 x 0.16 0.5 18.8 0.6 2.7 15
1.5 84 x 0.16 1.8 12.4 0.6 3 20
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 87
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Concentric Conductors with PVC Insulation
Application:
This wire is used in the manufacture of electrical harnesses for cars and other automotive
products.
Engineering Specification:
Conductor:
Concentric stranded copper conductor according to DIN ISO 72551, part 6, type A
Insulation:
Polyvinylchloride, according to DIN ISO 72551, part 5
Colour coding :
Two colours are marked by two diametrically opposed longitudinal stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-40oC up to + to 105 oC
TECHNICAL INFORMATION
Conductor
Nominal insulation Approximate Approximate net
Conductor size Max. DC Res. At
No.x dia. Approx. Diameter thickness overall diameter weight
20℃
mm2 No. x mm Mm Ohm /Km mm mm Kg/Km
0.35 7 x 0.26 0.8 52 0.2 1.3 4.5
0.5 19 x 0.19 1 37.1 0.22 1.6 6.6
0.75 19 x 0.23 1.2 24.7 0.24 1.9 9
1 19 x 0.32 1.35 18.5 0.24 2.1 11
1.5 19 x 0.32 1.7 12.7 0.24 2.4 16
2 19 x 0.37 2 9.42 0.24 2.6 22.5
2.5 19 x 0.41 2.2 7.6 0.28 3 26
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
88 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
PVC Thin Insulation
Application:
This wire is used in the manufacture of electrical harnesses for cars
and other automotive products.
Engineering Specification:
Conductor:
Fine wires stranded copper conductor according to DIN ISO 72551,
part 6, type B.
Insulation:
Polyvinylchloride, according to DIN ISO 72551, part 5
Colour coding:
Two colours are marked by two diametrically opposed longitudinal
stripes
Packing:
Cables are packed in carton boxes
Temperature range:
-40oC up to + to 105 oC
TECHNICAL INFORMATION
Conductor Details Minimum
Approximate Minimum Approximate
Conductor size insulation
Approx. Max. DC Res. overall diameter Concent. Factor net weight
No.x dia. thickness
Diameter At 20℃
www.cncuxc.com 89
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
HO5VV-F
Application:
These cables can be used for domestic cooking and heating appliances provided that the cable
does not come into contract with the heating elements.
TECHNICAL INFORMATION
Nominal
Conductor
insulation Nominal Sheath Approximate overall Approximate net
Conductor size
Max. DC Res. thickness Thickness diameter weight
No.x dia.
At 20℃
mm2 No. x mm Ohm /Km mm mm mm Kg/Km
2 x 0.75 24 x 0.2 26.4 0.6 0.8 6.5 61
2 x 1.0 32 x 0.2 19.5 0.6 0.8 6.8 70
2 x 1.5 30 x 0.25 13.3 0.7 0.8 7.7 91
2 x 2.5 50 x 0.25 7.98 0.8 1 9.4 139
2x4 56 x 0.3 4.95 0.8 1.1 10.7 192
3 x 0.75 24 x 0.2 26.4 0.6 0.8 6.9 73
3 x 1.00 32 x 0.2 19.5 0.6 0.8 7.2 85
3 x 1.5 30 x 0.25 13.3 0.7 0.9 8.4 114
3 x 2.5 50 x 0.25 7.98 0.8 1.1 10.2 175
3x4 56 x 0.3 4.95 0.8 1.2 11.6 244
4 x 0.75 24 x 0.2 26.4 0.6 0.9 7.7 91
4 x 1.0 32 x 0.2 19.5 0.6 0.9 8.1 106
4 x 1.5 30 x 0.25 13.3 0.7 1 9.3 142
4 x 2.5 50 x 0.25 7.98 0.8 1.1 11.1 211
4x4 56 x 0.3 4.95 0.8 1.2 12.6 297
90 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
HO3VV-F
Application:
These cables are useful in domestic premises, kitchens, offices or light duties for light portable
TECHNICAL INFORMATION
Conductor
Nominal insulation Nominal Sheath Approximate Approximate net
Conductor size
Max. DC Res. At thickness Thickness overall diameter weight
No.x dia.
20℃
mm2 No. x mm Ohm /Km mm mm mm Kg/Km
2 x 0.5 16 x 0.2 39 0.5 0.6 3.6 x 6.0 30
2 x 0.5 16 x 0.2 39 0.5 0.6 5.2 40
2 x 0.75 24 x 0.2 26.4 0.5 0.6 3.9 x 6.4 40
2 x 0.75 24 x 0.2 26.4 0.5 0.6 5.7 49
3 x 0.5 16 x 0.2 39 0.5 0.6 5.6 48
3 x 0.75 24 x 0.2 26.4 0.5 0.6 6 60
4 x 0.5 16 x 0.2 39 0.5 0.6 6.1 58
4 x 0.75 24 x 0.2 26.4 0.5 0.6 6.6 72
• The above data are approximate and subject to normal manufacturing tolerance.
• Other types can be provided on specific request.
www.cncuxc.com 91
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Suitable Cables:
HO3VV-F : 2 x 0.75
HO5VV-F : 2 x 0.75
HO5VV-F : 2 x 1.0
Group:
PVC Pug for Safety Class II
Voltage rating
300 / 300 V & 300 / 500 V only allowed for double insulated appliances
Description:
Straight flat plug without earthing contract
Material :
Glass – reinforced polyamide, black or white colour
Permitted Voltage:
250 V AC
Pins:
4.0 mm Ø solid metal
Pins, nickel – plated
92 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Suitable Cables:
HO5VV-F : 3 G 0.75
HO5VV-F : 3 G 1.0
HO5VV-F : 3 G 1.5
Group:
PVC Pug for Safety Class I
Voltage rating
300 / 500 V
Description:
2- pin angled plug with double earthing system
Material :
PBTP 30% glass – reinforced, anthracite black or white colour
Pins:
4.8 mm Ø solid metal
Pins, nickel – plated
www.cncuxc.com 93
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Suitable Cables:
HO3VV-F : 3 G 0.75
HO5VV-F : 3 G 0.75
HO5VV-F : 3 G 1.0
Group:
PVC Plug for Safety Class I
Voltage rating:
300 / 300 V & 300 / 500 V
Description:
2 - pin angled plug with lateral earthing
system
Material :
PBTP 30% glass – reinforced, anthracite black
or white colour
Pins:
4.8 mm Ø solid metal
Pins, nickel – plated
94 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
DC resistance of conductor:
DC resistance per unit length of the conductor at another conductor temperature t is given by:
R=RO [1+ α20 (t-20OC)]
Where:
R = DC resistance at temperature to C Ω/Km
Ro = DC resistance at temperature 20oC Ω/Km
t = conductor temperature C
o
AC Resistance of Conductor:
To calculate the AC resistance of the conductor at its operating temperature the following formula is used:
Rac = R ( 1 + Kp + Ks)
Where:
KP and KS are proximity effect and skin effect factors
Inductance:
Self mutal inductance is defined as follows:
25
L = K + 0.2 Ln ( )
d
Where:
L = Inductance in mH / Km
K = A constant depending on the number of wires in the conductor
d = Conductor diameter in mm
n = Axial spacing between cables in trefoil formation in mm
= 1.26 x axial spacing between cables in flat formation in mm
www.cncuxc.com 95
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Capacitance:
The mutual capacitance of the pairs or adjacent cores shall not exceed a maximum of 250 PF/m at a frequency
of 1KHz
1- Mutual capacitance of unshielded twisted pair
7.218
C
1.3D
log( )
fd
2- Mutual capacitance of shielded twisted pair
21.14
C
1.2 D
log( )
fd
3- Mutual capacitance of overall shielded & cables
9.515
C
1.5D
log( )
fd
Where:
C : Mutual Capacitance In PF/m
ε : Dielectric constant of insulation material
D : Diameter over insulation in mm
d : Diameter over conductor in mm
L / R ratio:
The L / R ratio for adjacent cores shall not exceed the following maximum value:
96 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Impedance Zo (ohms):
310
1- Unshielded twisted pair : Zo
C
276 1.2D
2- Shielded twisted pair : Zo log( )
f(d)
347 1.5D
3- Overall shield & cabled : Zo log( )
f(d)
Where:
C : Mutual Capacitance In PF/m
ε : Dielectric constant of insulation material
f : Stranding factor depend on no. of wires in conductor
D : Diameter over insulation in mm
d : Diameter over conductor in mm
Attenuation:
The power loss in an electrical system, in cables, generally expressed in decibels (dB) per unit length
RGW
: A) 86.8
Attenuation (
2
Where:
A: Attenuation in dB per 100 ft
R: Resistance (AC)
G: Conductance
W: 2Π f (f= test frequency MHz)
Velocity of Propagation:
The speed of an electrical signal down a length of cable compared to speed in free space expressed as a percent.
It is inversely proportional to the dielectric constant. Lowering the dielectric constant. Lowering the dielectric
constant increases the velocity
1 1
Vp orVp
Lc
Where:
E : Dielectric constant
L: Inductance
C: Capacitance
www.cncuxc.com 97
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Vp
Dielectric medium or material
(%)
Air 100
Solid polyethylene 65.9
Foamed polyethylene 80
PVC 45
98 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Fire Resistant cables:
A cable can be described as fire resistant when it complies with the severe test in IEC 331 in which the middle
portion of a sample of cable 1200 mm long is supported by two metal rings 300 mm apart and exposed to the
flame from a tube type gas burner at 750oC. Simultaneously the rated voltage of the cable is applied continuously
throughout the test period. Furthermore, not less than 12 hours after the flame has been extinguished, the cable is
reenergized. No electrical failure must occur under these conditions.
Halogen Free Material:
What are Halogens?
Halogens are salts of the elements Fluorine, Chlorine, Bromine and lodine.
Fluorine and chlorine are important in cable design. For example; Flourine, Chlorine and Bromine are common
components of flame protection additives.
When is a cable Halogen–free?
The burning behavior of cables is very important for the safety of buildings and also in control plants.
Consequently the following points are important:
•Behavior under flame influence ie. the inflammability as the propagation of fire.
•Development of smoke density (darkening of emergency exits, hindrance of the fire fighters).
Cables produced of non halogen – free materials such as those with chlorine in the molecule – chain :
polyvinylchloride (PVC), chloroprene rubber (CR), chlorinated polyethylene (CM), have a better behavior in case
of fire.
These are barely combustible or not flammable and self-extinguishing, in case of fire molecules of Chlorine (or Fluorine) are released
which hinder the access of oxygen at the fire location and hence suffocate the flame.
The disadvantage of these materials is that the released Chlorine (or Flourine) atoms combine with hydrogen
which is decomposed from the plastic material as wel as hydro choleric acid or hydroflouoric acid from the existing
air. These compounds are extremely corrosive and toxic in consequence, damage by corrosion may be higher
than the damage caused by fire.
Halogen-free cables contain no halogens, le. the insulation and sheath materials of these cables are composed
of polymers of pure hydrocarbons. Burning these materials, produce no corrosive compounds or toxic gases, only
water vapor and carbon dioxide gas.
For maximum security halogen free cable must be hardly flammable and self-extinguishing . This is achieved by
using special polymer compounds, containing high percentages of flame protective materials .
Application:
Halogen-free cable are increasingly specified for public buildings and areas where large numbers of people may
be present.
LAN Cables:
The necessity to communicate through digital information, to share data, to reach calculation – resources and
to share costly devices has encourages the development of local area networks. A local area network (LAN) is
a computer network linking users in a small area. Generally, a local area network connects users located either
in the same office, or at the same floor, or in the same building. The success of local area networks is due to their
ability to satisfy communication needs at a reasonable price. Compatibility is a critical element.
Local area networks require high–speed channels for data–transmission, permitting the transfer of large blocks of
data, images, and video-signals.
The technology used in local networks can reach a transmission rate which is higher that 100 Mbps, Ie. higher
www.cncuxc.com 99
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
than that of traditional direct connections. Moreover, the traditionally low transfer – capacity of public
telecommunications is increasing therefore the distinction between direct connection, local area networks and
wide area networks is going to loose significance, at least as far as transmission – capacity is concerned.
The transmission media is the cable. Common media are phone-pairs, coaxial cables and purpose designed LAN
cables which are essentially extremely high performance telephone pairs, sometimes provided with shielding. This
kind of shielded cable is more immune to electrical interference and permits high speed transmission over longer
distances. Pairs are still the most versatile media for transmission and are often the best choice for new network
installations.
Attenuation:
The reduction in a transmitted signal as it passes through wires or equipment in an electrical circuit.
100 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Near end crosstalk loss (Next):
The near–end crosstalk loss of a link shall meet or exceed the values shown in table below, and
shall be consistent with the design values of cable length and cabling materials used.
(MHz) dB
1< F < 10 18
10< F < 16 15
16< F < 20 15
20< F < 100 10
www.cncuxc.com 101
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Coaxial Cable :
A cable consisting of two cylindrical with a common axis, separated by a dielectric
Electrical Parameters:
138 D
1- Characteristic Impedance: Zo log( )
d
100%
2- Velocity of Propagation: Vp
24.148
3- Capacitance: C PF/m
D
log( )
d
D
4- Inductance: L 0.459log( )
d
5- Braiding Details:
2 e p
Braid angle: tan( )Degrees
-1
C
0.394 c tan
Braid picks per cm: p
2 M
r
Braid resistance: R
n C cos
Where:
D = Diameter under shield in mm n = number of wires in one carrier
d = conductor diameter in mm M = D + build of braid on one shield wall in mm
ε = dielectric constant of insulation e = diameter of each wire in mm
= 1.56 cellular polyethylene R = DC resistance of the braid in ohm/km
= 2.26 solid polyethylene r = DC resistance of each wire in ohm/km
C= number of carriers p = picks per cm
102 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Packing:
1- LAN Cable:
Available in easy – pull boxes of 1000 feet (305m) capacity.
This assures the cable will not be damaged during installation due to the
“figure 8” coiling.
It also enables easy, tidy storage before and during installation.
2 - Coaxial Cable:
Available in easy – pull boxes of 100 m or 500m on wooden drum.
3 - Telephone Cable:
Cables supplied on coils of (200m) or in non-returnable wooden drums.
4 - Automotive wires:
Wires are packed in Carton boxes which reduces storage area & cost.
Boxes may be delivered individually or as a solid cube on wooden pallet.
www.cncuxc.com 103
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
5- Instrumentation, Fire Resistant and Control Cables:
International practice is to supply cables on wooden drums. At the customers request
we will also supply on steel drums for improved on-site performance and handling.
DRUM DIMENSIONS
D D d1 B1 B2 W1 W2
600 300 85 410 530 16 300
700 350 85 410 530 20 350
800 400 85 410 530 24 400
1000 500 85 610 710 46 800
1250 580 85 580 680 60 1700
1400 700 85 800 950 160 2000
1600 700 110 800 950 170 2500
1800 920 110 900 1050 240 3000
2000 1020 110 1200 1350 335 4000
Where:
D : Flange diameter mm.
d : Barrel diameter mm.
d1: Axis hole diameter mm.
B1 : Distance between flanges mm.
B2 : Overall width mm.
W1: Approximate net weight of drum Kg.
W2: Maximum gross weight of drum Kg.
By To Multiply By To obtain
104 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Weight – Imperial Length – Imperial
Ounces 28.495 grams Mils 0.001 Inches
Pounds (AV) 453.59 grams Mils 0.0254 mm
Pounds (AV) 0.45359 kilograms Inches 1000 Mils
Tons (short) 907.19 kilograms Inches 25.40 Mm
Tons (long) 1016.05 kilograms Inches 2.54 Cm
Weight – Metric Feet 30.48 Cm
Grams 0.03527 Ounces Feet 0.3048 Meters
Grams 0.002205 Pounds Feet (thousands of) 0.3048 Kilometers
Kilograms 35.274 Ounces Yards 0.9144 Meters
Kilograms 2.2046 Pounds miles 1.3093 Kilometers
Kilograms 0.001102 Tons (short) Length-metric
Kilograms 0.0009842 Tone (long) Millimeters 39.37 Mils
Millimeters 0.03937 inches
Miscellaneous – Imperial Centimeters 0.3937 Inches
Pounds per 1000 feet 1.48816 Kg/ Km Centimeters 0.032808 Feet
Pounds per mile 0.28185 Kg/ Km Meters 39.37 Inches
Pounds per square inch 0.0007031 Kg. per square mm. Meters 3.2808 Feet
Pounds per square inch 0.07031 Kg. per square cm Meters 1.0936 Yards
Pounds per cubic 27.68 Grams per cubic cm Kilometers 3280.83 Feet
Feet per second 18.288 Meters per minute Kilometers 0.62137 Miles
Feet per second 1.09728 Kilometers per hour
Miles per hour 1.60935 Kilometers per hour Area – Imperial
Ohms per 1000 feet 3.28083 Ohms per kilometer Square mils 1.2732 Circular mils
Ohms per mile 0.62137 Ohms per kilometer Square mils 0.000001 Square inches
Decibels per 1000 feet 3.28083 Decibels per kilometer Circular mils 0.7854 Square mils
Decibels per mile 0.62137 Decibels per kilometer Circular mils 0.0000007954 Square inches
Decibels 0.1153 nepers. Square mils 0.0005037 Square mm.
Square inches 1000000 Square mils
Miscellaneous – Metric Square inches 1273240 Circular mils
Kg / Km 0.67197 Pounds per 100 feet Square inches 645.16 Square mm
Kg / Km 3.54795 Pound per mile Square inches 645.16 Square cm.
Kg. per square mm 1422.34 Pound per square inch Square feet 0.09290 Square meters
Kg. per square cm 14.2234 Pound per square inch Square yards 0.8361 Square meters
Grams per cubic cm 0.03613 Pound per cubic inch
Meters per minute 0.05468 Feet per second Area – Metric
Kilometers per hour 0.91134 Feet per second Square millimeters 1973.52 Circular mils
Kilometers per hour 0.62137 Miles per hour Square millimeters 0.00155 Square inches
Ohms per kilometer 0.3048 Ohms per 1000 feet. Square centimeters 0.155 Square inches
Ohms per kilometer 1.6093 Ohms per mile Square meters 10.7638 Square feet
Decibels per kilometer 0.3048 Decibels per 1000 feet Square meters 1.19599 Square yards
Decibels per kilometer 1.6093 Decibels per mile
www.cncuxc.com 105
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Volume – Imperial
Temperature Cubic inches 16.38716 Cubic cm.
Fahrenheit 5/9(*F)-32 *Celsius Cubic feet 0.028317 Cubic meters.
Celsius 9/5 (*C)+32 * Fahrenheit Volume – U. S.
Quarts (liquid) 0.9463 Liters
Gallons 3.7854 Liters
Volume – Metric
Cubic cm 0.06102 Cubic incuse
Cubic meters 35.3145 Cubic feet.
Liters 1.05668 Quarts.(liquid U.S)
Liters 0.26417 Gallons (U.S.)
106 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
A direct current resistance.
Area of conductor Active current
The size of conductor cross-section measured in circular mils, In an alternating current, a component in phase with the
square inches, etc. voltage. The working component as distinguished from the
Armor idle or wattles component.
A braid or wrapping of metal, usually steel, used for mechanical Aerial cable
protection. A cable suspended in the air on poles or other overhead
Armored cable structure.
A cable having a metallic covering for protection against Air core cable
mechanical injury. A telephone cable in which the interstices in the cable core
Astm are not filled with a moisture bloking material.
The American society for Testing and materials Air spaced coaxial cable
Attenuation One in which air is the essential dielectric material. A spirally
The reduction in a transmitted signal as it passes through wires wound synthetic filament or spacer may be used to center
or equipment in an electrical circuit. the conductor.
AWG Alpeth
Abbreviation for American wire gauge. A telephone cable having an aluminum shield and a
Abrasion Resistance: polyethylene jacket.
Ability of a material or cable to resist surface wear. Alternating current (A.C.)
A.C. Resistance An electric current that continually reverses its direction giving
The total resistance offered by a device to alternating current a rebetitive plus and minus wave form at fixed intervals.
circuit due to inductive and capacitive effects, as well as the
Alternating voltage: of heat to render it less brittle
The voltage developed across a resistance or impedance Anode
through which alternating current is flowing. The electrode through which a direct current enters the
Ambient temperature liquid, gas or other discrete part of an electrical circuit; the
The romal temperature within a given area positively charged pole of an electrochemical cell.
American wire gauge Appliance wire and cable
A standard used in the determination of the physical size Appliance wiring material is a classification of underwriters’
of a conductor determined by its circular mil area. Usually laboratories, inc., covering insulated wire and cable, internal
expressed as AWG. Also referred to as brown and sharpe wiring of appliances and equipment. Each construction
(B&S) wire gauge. satisfies the requirements for use in particular applications.
Ampacity: B
The maximum current an insulated wire or cable can safely Balance circuit
carry without exceeding either he insulation or jacket material A circuit so arranged that the impressed voltage on each
limitations (Same as current carrying capacity). conductor of the pair are equal in magnitude but opposite in
Ampere polarity with respect to ground.
The unit current. One ampere is the current flowing thought Band width
on ohm of resistance at one volt potential . The frequency range of transmitted electrical signals,
Anneal expressed
To subject to high heat wit subsequent cooling. When in Hertz.
annealing copper, the act of softening the metal by means Bare conductor
www.cncuxc.com 107
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
A conductor having no covering. A conductor with no coating or cladding on the copper.
Bedding
A layer of material applied to a cable immediately below the and the axis of the cable being shielded.
armoring. Breakdown of insulation
Binder Failure of an insulated conductor resulting in a flow of current
A spirally served tape or thread used for holding assembled through the insulation. It may be caused by the application of
cable components in place awaiting subsequent excess voltage or by defects or decay.
manufacturing operations. Breakdown voltage
Bonded flat cable The voltage at which the insulation between two conductors
Flat cable consisting of individually insulated conductors lying breaks down.
parallel and bonded together typically for application in Bunched Strand
electronics, telecommunications. Or computers. Any number of conductor strands twisted together in one
Braid direction with the same lay length.
A fibrous or metallic group of filaments interwoven in cylindrical Buried Cable
form to form a covering over one or more wires. A cable installed directly in the ground without use of
Braid angle underground conduit. Also called “ direct burial cable”.
The smaller of the two angles formed by the shielding strand
C circuits.
Colour Code Core
A colour system for circuit identification by use of solid colours, In cables, a term used to denote a component or assembly of
tracers, braids , surface printing, etc. components, over which other materials are applied, such as
Composite cable additional components, shied, sheath, or armor.
A cable consisting of two or more different types or sizes of Cross-Sectional Area
wires. The area of the cut surface of an object cut at right angles to
Concentricity the length of the object.
In a wire or cable, the measurement of the location of the Crosstalk
center of the conductor with respect to the geometric center Signal interference between nearby conductors caused by
of the circular insulation. pickup of stray energy. It is also called induced interference.
Concentric Stranding Cure
A group of wires twisted so as to contain a center core with one To change the physical properties of a material by chemical
or more distinct layers of spirally wrapped, wires laid overall. reaction, by the action of heat and catalysts, alone or in
Conductance combination, with or without pressure.
The ability of a conductor to carry electric current. It is the Current
reciprocal of resistance and is measured in Mhos. The rate of flow of electricity in a circuit , measured in
Conductivity amperes.
A term used in describing the capability of a material to carry an Current Carrying Capacity
electrical charge. Usually expressed as a percentage of copper The maximum current an insulated conductor or cable can
conductivity copper being one hundred (100%) percent. continuously carry without exceeding its temperature rating. It
Conductor is also called ampacity.
Any material capable of transferring electrical charge easily. Current, Direct (D.C.)
Control cable Electrical current whose electrons flow in one direction only ; it
A multi-conductor cable made for operation in control or signal may be constant or pulsating as long as their movement is in
108 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
the side-to-side, pair – to- pair unbalance.
same direction. Capacitance unbalance to ground
Cycle An inequality of capacitance between the ground
The complete sequence of alternation or reversal of alternation capacitance the conductors of a pair which results in
or reversal of the flow of an alternating electric current. (See a pickup of external source energy, usually from power
Hertz) transmission lines.
Cable Capacitance coupling
A group of individually insulated conductors in twisted or Electrical interaction between two conductors caused by
parallel configuration, with or without an overall covering. the capacitance between them.
Cable, Star Quad Characteristic impedance
A multicore radio or television relay cable in which the The impedance that , when connected to the output
conductors are arranged in quads and each quad terminals of a transmission line of any length, makes the
consists of four conductors twisted together, the diagonally line appear infinitely long. The ratio of voltage to current
opposite conductors constituting a pair circuit. Also known at every point along a transmission line on which there are
as spiral four cable. no stranding waves.
Cabling Charge
The act of twisting together two or more insulated The quantity of electricity held statically in a capacitor or
components by machine to form a cable. an insulated conductor.
Capacitance: Circular Mil
Storage of electrically separated charges between two A measurement used in determining the area of wire.
plates having different potentials. The area of a circle one thousandth (.001) of an inch in
The value depends on the surface area of the plates and diameter.
the distance and material between them. Coating
Capacitance, Direct: A material applied to the surface of a conductor to
The capacitance measured directly with all other prevent environmental deterioration, facilitate soldering
conductors, including shield, short circuited to ground. or improve electrical performance.
Capacitance, Mutual Coaxial Cable
The capacitance between two conductors with all other A cable consisting of two cylindrical conductors with a
conductors, including shield, short circuited to ground. common axis, separated by a dielectric.
Capacitance unbalance Cold Test
The inequalities of the capacitances of the wires of a Any test to determine the performance of cable during
telephone circuit to other wires or to earth which produce or after subjection to a specified low temperature for a
interference. Various forms of unbalance arise according specified time
to the circuits concerned in the measurement, hence
D The ratio of the capacitance of a capacitor (or consoles)
www.cncuxc.com 109
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Dielectric test Foamskin
A test in which a higher than the rated voltage is applied for Polyethylene foam insulation
a specified time to determine the adequacy of the insulation Frequency
under normal conditions. Number of times an alternating current reverses itself in
Direct capacitance one second. Expressed in Hertz (Hz), which is one cycle per
The capacitance measured directly from conductor to second.
conductor through a single insulation layer. G
Flame Resistance Hz
Ability of the material to extinguish flame once the source Abbreviation for Hertz.
of heat is removed E
110 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Embossing IEC
A means of identification or lettering usingheat and or International Electrotechnical Commission, Similar to the
pressure to leave raised lettering on the sheath material of ISO in structure and scope.
the cable. IEEE
Emergency overloads Institute of Electrical and Electronic Engineers.
Loads which occur when larger than normal currents are F
carried through a cable or wire oven a short period time. Farad
Extrusion A unit of electrical capacity
The process of continuously forcing a plastic or elastomer Fext
and a conductor core through a die, thereby applying a Far end crosstalk
continuous coating of insulation or jacket to the core or Figure 8 cable
conductor. An aerial cable configuration in which the conductors and
I the strand which supports the cable are integrally jacketed
www.cncuxc.com 111
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
also be included. A term denoting 1000 watts.
MCM Next
One thousand circular Mils. Near end crosstalk
Megohm O
One million ohms Ohm
Mho Unit of resistance such that a constant current of one
The unit of conductivity. The reciprocal of an ohm. ampere produces a force of one volt.
Mhz Overall Diameter
Megahertz (one million cycles per second) Finished diameter over wire or cable
Microphonics Over Current
Noise in a system caused by mechanical vibration of The Current which causes and excessive temperature
components within the system. rise in a conductor.
Microwave Overload Capacity
A short (usually less than 30cm.) Electrical wave. The maximum level of current, voltage, or power which
Mill a device can withstand before it is damaged.
A unit used in measuring diameter of a wire or L
thickness of insulation over a conductor. One onethousandth Lay Direction
of an inch (0.001”). The direction in which the strands of a conductor run
Moisture Resistance over the top of the conductor as they recede from and
The ability of a material to resist absorbing moisture observer looking along the axis of the conductor.
from the air or when immersed in water. Leakage Current
Multi-Conductor The undesirable flow of current through or over the
More than one conductor within a single cable. surface of an insulation
Mutual inductance RFI
The ratio of voltage induced in one conductor to Radio Frequency Interference.
the time rate of current change in the separate RG/U
conductor causing this induction. Radio Government, Universal. RG is the military designation
Mylar for coaxial cable and U stands for “ general Utility”.
DuPont trademark for polyethylene terephthalate Round Conductor
(polyester) film used in the form of a tape. A conductor whose cross-section is substantially circular
J Oxygen index
Jacket Percentage of Oxygen necessary to support combustion
A material covering over a wire insulation or an of specified material.
assembly of components. An overall jacket on a P
complex cable grouping is also often referred to as Pair
a sheath. Two insulated wires of a single circuit associated
K together.
Kilohertz Peak Voltage
1.000 Hertz (cycles per second) The maximum instantaneous voltage.
Kilovolt Percent Conductivity
A term denoting 1000 volts. Conductivity of a material expressed as a percentage of
Kilowatt that of copper
112 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
Polyester Shield Coverage
Polyethylene terephthalate which is used extensively in The physical area of a cable that is actually covered by
the production of a high strength moisture resistant film the shielding material and is expressed in percentage.
used as cable core wrapping material. Signal
Polyethylene Current used to convey information, either digital,
A family of insulating materials derived from polymerization analogue, audio or video.
of ethylene gas. They are basically pure hydrocarbon Single cable
resins, with excellent dielectric properties. A cable designed to carry current of usually less than one
Polypropylene ampere per conductor.
A thermoplastic polymer of propylene. Skin Effect
Polyvinlychloride (PVC). The tendency of alternating current, as its frequency
A thermoplastic material composed of polymers of increases, to travel only on the surface of a conductor.
vinylchloride which may be rigid or eleastomeric, Solid Conductor
depending on specific formulation. A conductor consisting of a single wire.
Power Factor Spark Test
The ratio of resistance to impedance. The ratio of the A test designed to locate imperfections (usually pinholes)
actual power of an alternating current to apparent in a wire insulation by application of an electrical
power. Mathematically, the cosine of the angle between potential across the material for a short period of time
the voltage applied and the current resulting. while the wire is drawn through an electrode field with
Propagation time one end of the wire grounded.
The required for an electrical wave to travel between two Specific Gravity
points on a transmission line. The ratio of the weight of any volume of substance to
Pulse a weight of an equal volume of some substance taken
A current or voltage which changes abruptly from one as a standard, usually water for liquids and hydrogen for
value to another and back to the original value in a finite gases.
length of time. Square Mil
Pulse Cable The area of a square on mil by one mil.
A type of coaxial cable constructed to transmit repeated Stranded conductor
high voltage pulses without degradation. A conductor composed of individual groups of wires
S twisted together to form an entire unit.
Sheath Strand Lay length
The material, usually an extruded plastic or elastomer, A distance of advance of on strand of a spirally stranded
applied outermost to a wire or cable. Very often refereed conductor, in one turn, measured axially.
to as a jacket. Q
Shield Quad
A metallic layer around an insulated conductor or group A four- wire unit of insulated conductors. See star quad
of conductors to prevent electrostatic or electromagnetic R
interference between the enclosed wires and external Rated Temperature
fields. This shield can be braided or served wires, foil The maximum temperature at which an electric
wrap, foil backed tape, a metallic tube , or conductors, component can operate for extended periods without
the shielding effectiveness is in proportion to the amount loss of its operating properties
of coverage, usually expressed in percentage. Rated Voltage
www.cncuxc.com 113
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *
The maximum voltage at which an electric component Twin Cable
can operate for extended periods without degradation A cable composed of two separated insulated stranded
of performance or safety hazard. conductors laid parallel under a common covering.
Thermal Rating pressure that will cause one ampere of current in one ohm
The maximum and / or minimum temperature at which a of resistance.
material will per form its functions without undue degration. Voltage
Thermal Shock The term most often used in place of electromotive
A test to deter mine the ability of a material to withstand force, potential, potential difference, or voltage drop, to
heat and cold by subjecting it to rapid and wide change designate electric pressure that exists between two points
in temperature. and is capable of producing a flow of current when a
114 www.cncuxc.com
Add: INDUSTRIAL PARK, GONGYI, HENAN, P. R. CHINA/Code:450042
Tel.:0086-371- 5508-3768 /Fax:0086-371- 5508-3768
*HNXC--- TRANS MORE *