Flyer Aracus Advance PDF

The document describes the ARACUS advanced amino acid analyzer. It has an extended configuration from the classic model with a second pump drive. This allows independent operation of two fluidic lines and improved signal-to-noise ratio. The system can continuously analyze 96 samples in a cooled autosampler and uses reagents like OPA and ninhydrin for fluorescence detection and quantitative analysis of primary amines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views1 page

Flyer Aracus Advance PDF

The document describes the ARACUS advanced amino acid analyzer. It has an extended configuration from the classic model with a second pump drive. This allows independent operation of two fluidic lines and improved signal-to-noise ratio. The system can continuously analyze 96 samples in a cooled autosampler and uses reagents like OPA and ninhydrin for fluorescence detection and quantitative analysis of primary amines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ARACUS

The Next Generation -


The proven gold standard Amino Acid Analyzer

ARACUS advanced Amino Acid Analyzer


Extended configuration of the ARACUS Classic

The ARACUS „advanced“ is an extended configuration of the ARACUS „classic“ by an additional second pump drive.
The system allows the continous analysis of 96 samples in a cooled autosampler.
The upgraded pump configurations allows the independent operation of two fluidic lines (eluent side and reactive
side).
The use of two pump drives results in an improved signal-to-noise ratio of the chromatogram.
The freely adjustable parameters between the eluent and the reagent pump drives also provide the possibility of
using the reagent OPA (o-phthalaldehyde) for detection of primary amines with a fluorescence detector.
The addition of ninhydrin provides a quantitative analysis statement.
A washing routine of the injection valve and syringe pump avoids cross contaminations
Main technical specifications of the system​
Method
Post column derivatization with ninhydrin

Reproducibility of retention time & area:


< 0.3 % RSD
ca. 1 % RSD

Detection limit
< 2 nmol/mL

Flowchart
The chart shows the structure of the lite setup:
The upgraded pump configurations allows the
independent operation of two fluidic lines (eluent
side and reactive side).
The use of two pump drives results in an
improved signal-to-noise ratio of the
chromatogram.
The system is equipped with an autosampler with
100 µL loop

Options

Manual injection Prime and IQ/OQ/PQ Software 21 CFR


Inert gas
port purge valves documents Part 11 compliance