RA30 Series PA N E L C O N T R O L S
Features
䡲 30mm diameter, single-turn industrial panel controls 䡲 Wirewound element 䡲 Linear or audio tapers
䡲 Single, tandem and triple units, single shaft; dual unit, dual shaft 䡲 SPST or SPDT switch with 1A or 3A rating
䡲 Shaft lock and center tap models 䡲 Metal shaft and bushing 䡲 Temperature range of ⴑ10ⴗC or ⴑ30ⴗC, up to ⴐ100ⴗC
䡲 Panel mount only 䡲 6mm diameter shafts in slot, flat or round end styles 䡲 Standard 15mm or 20mm shaft length
Specifications
Electrical Environmental
Standard Resistance Range . . . . . . . . . . . B = 5Ω to 20kΩ Temperature Range . . . . . . . . . . . . . . Y = ⴑ10ⴗC to ⴐ100ⴗC
A,C = 100Ω to 5kΩ or X = ⴑ30ⴗC to ⴐ100ⴗC
Resistance Tolerance . . . . . . . . . . . . . . . . . ⴣ10% standard Temperature Characteristics . . . . . . . . . . .ⴐ85ⴗC, 5 hours
(ⴣ5%,ⴣ2% or ⴣ1% special order ) without load
End Resistance . . . . . . . . . . . . . . . . . . R ! 500Ω = 1Ω max. ∆T/R )ⴣ5%
R 0 500Ω = 0.2% max. Low Temperature Exposure . . . . . . . ⴑ10ⴗC ( Y ),ⴑ30ⴗC ( X )
Resistance Taper . . . . B = linear; A = CW audio (logarithm); 1 hour without load
C = CCW audio (logarithm) ∆T/R )ⴣ3%
Power Rating . . . B = 2.5 watts; A,C = 1.25 watts, at ⴐ40ⴗC Load Life . . . . . . . . . . . . ⴐ40ⴗC, 1,000 hours with rated load
Insulation Resistance . . . . . . . 100MΩ minimum at 500VDC ∆T/R )ⴣ3%
Dielectric Strength . . . . . . . . . . . . . . . . . . 500VAC, 1 minute Moisture and Load Life . . . . . . . . . . . .ⴐ40ⴗC, 90-95%RH,
500 hours with 1/10 rated load
Theoretical Resolution
∆T/R )ⴣ5%
Resistance ( Ω ) Resolution ( % ) Resistance ( Ω ) Resolution ( % )
Vibration . . . . . . . . . . . . . . . . . . .10-55Hz, 1.5mm amplitude,
5 1.62 500 0.23
10 0.81 1,000 0.19
2 directions, 2 hours each
20 0.67 2,000 0.15 ∆T/R )ⴣ1%
50 0.45 5,000 0.14
100 0.44 10,000 0.12
Soldering Heat Resistance . . . . . . . . . 350ⴗC, 3.5 seconds;
200 0.32 20,000 0.10 ∆T/R )ⴣ2%
Rotational Life . . . . 15,000 cycles (500 cycles for shaft lock
Mechanical models only) with 1/2 rated load
Mechanical Travel . . . . . . . . . . . . . . . . . . . . . . . . . . 300ⴗⴣ5ⴗ ∆T/R )ⴣ3%
Shaft Torque Standard Rotary Switches
Single Unit . . . . . 70.1 to 306 gf • cm (0.972 to 4.242 oz • in) Switch Rating . . . . . . . . . . 110VAC, 1A or 3A, SPDT or SPST
Tandem Unit . . . . . . 70 to 701 gf • cm (0.97 to 9.718 oz • in)
Other Units . . . . . . . 70 to 450 gf • cm (0.97 to 6.238 oz • in) Contact Resistance . . . . . . . . . . . . . . . . . . . . . . 0.05Ω max.
Stop Strength . . . . . . . . . . . . 10.2 kgf • cm (141.4 oz • in) max. Operating Torque . . . . . . . . 1,500 gf • cm (20.79 oz • in) max.
Mounting Nut Torque . . . . . . 15 kgf • cm (207.94 oz • in) max. Operating Life . . . . . . . . . . . . . . . 10,000 cycles without load
Solderability . . . . . . . . . . . . . . . . . . . . . . . 235ⴗC, 3 seconds R = Total Resistance Value; ∆T/R = Total Resistance Change
Recommended
Panel Mounting Holes
Recommended
Panel Mounting Holes
Recommended
Panel Mounting Holes
RAT30Y Unit: mm
Panel Mount, Single Unit with Center Tap, Single Shaft
Right Angle Ear-Lug Terminals, Tap Lug Terminal 105ⴗ from Terminal #1
Recommended
Panel Mounting Holes
RA30YG
Panel Mount, Ganged Tandem Unit, Single Shaft
Right Angle Ear-Lug Terminals on Each Unit
Recommended
Panel Mounting Holes
RA30YGL
Panel Mount, Ganged Tandem Unit, Single Shaft with Shaft Lock
Right Angle Ear-Lug Terminals on Each Unit
Recommended
Panel Mounting Holes
RAT30YG Unit: mm
Panel Mount, Ganged Tandem Unit with Center Tap, Single Shaft
Right Angle Ear-Lug Terminals, Tap Lug Terminal 105ⴗ from Terminal #1
Recommended
Panel Mounting Holes
RA30YT
Panel Mount, Triple Unit, Single Shaft
Right Angle Ear-Lug Terminals on Each Unit
Recommended
Panel Mounting Holes
RA30YD
Panel Mount, Dual Unit, Dual Concentric Shaft
Right Angle Ear-Lug Terminals on Each Unit
Recommended
Panel Mounting Holes
Refer to Shaft End Styles Specifications and Hardware Specifications for details and availability.
For additional information, refer to Guidelines and Precautions for Using Panel Controls.