0% found this document useful (0 votes)
121 views2 pages

SLW Series: Years in Process Control Instrumentation

The document describes a conductivity level limit switch called the SLW Series that uses electrodes to sense the level of conductive liquids in tanks and can control pumps and valves. It works by applying a low AC voltage between an electrode probe and the tank wall to detect when liquid makes contact. The SLW Series is available in different models for single-point switching, pump control logic, and multiple-point level detection applications.

Uploaded by

dklike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
121 views2 pages

SLW Series: Years in Process Control Instrumentation

The document describes a conductivity level limit switch called the SLW Series that uses electrodes to sense the level of conductive liquids in tanks and can control pumps and valves. It works by applying a low AC voltage between an electrode probe and the tank wall to detect when liquid makes contact. The SLW Series is available in different models for single-point switching, pump control logic, and multiple-point level detection applications.

Uploaded by

dklike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Grown...

to meet challenges 30+ years in Process Control Instrumentation

SLW Series ­ Conductivity Level Limit Switch Version 2.1

Conductivity level limit switches are based on the principle of measuring level
through the electrical properties of the process material. As the name suggests,
the switch senses the level of water or other liquids that have free ions, and are
successfully used in processing plants for conductive liquids of conductivity not
less than 25 Siemens.

Principle
A low AC voltage is applied between the probe electrode and the tank wall (or reference
electrode in case of insulated tanks). When the liquid comes in contact with the electrode
tip, a conductive path is established between the sense electrode and the tank wall /
reference electrode. This current is sensed, amplified and made to operate a relay whose
contacts in turn can be used for annunciation / control.

ApprovalssCE Marking, RoHS Compliance


Features Parts
• No moving parts, hence free from maintenance The parts of SLW are explained in the Figure 1. All
• No special cable required for signal transmission dimensions are in millimeters. Figure 2 describes the
• Economical to install system diagram of SLW.
• Allows long connectivity between probe and evaluation unit
• AC on probe prevents electrodes' electrolytic deterioration
• Low voltage on probe for operational safety Φ85 200 (
C/C)
Cast aluminium
• Variety of probes for unique process conditions housing
weatherproof
• Variety of control functions, installation systems
90

/C)

Cable entry
6 0 (C

Applications
Mounting thread
• Switch pumps off when tank is full, to avoid overflow
• Maintain a constant level to avoid material wastage Seperator

• Switch off pumps when running dry EVALUATION UNIT


(Overal size : 215x195x85
• Identify empty tank to avoid wear­tear,production stoppage
Excluding cable gland)

Why Sapcon
• Sapcon ~ Synonymous with Level Measurement. Reference probe
• Pioneers in this field with over 32 years of expertise. Low level probe

• Understanding your problems, always ready with solutions. High level probe
Figure 1: Parts of SLW
• Masters in customization.
• Offering accelerated delivery, saving your inventory costs.
Manufacturing Level Instruments & Speed Monitoring Systems

SAPCON INSTRUMENTS PVT. LTD.


An ISO 22000 company
131 Palshikar Colony, Indore, Madhya Pradesh, PIN ­ 452004, India
+91­731­4757575 (100 lines) Fax: +91­731­2475475
www.sapconinstruments.com Email: [email protected]
Model Selection
SLW SERIES

MODEL

121­ SINGLE POINT SWITCH (1 RELAY)

221­ SINGLE­ POINTSWITCH (2 RELAYS IN PARALLEL)

321­ SINGLE­ POINT SWITCH (WITH TIME DELAY)

521­ PUMP CONTROL LOGIC (WITH ONE RELAY)


Figure 2: System Diagram of SLW
721­ PUMP CONTROL LOGIC (WITH 2 RELAYS IN PARALLEL)

Technical Specifications 821­ TWO­POINT SWITCH (1 RELAY FOR EACH SET POINT)

Evaluation Unit 8P1­ ONE PUMP­ CONTROL + SINGLE­ POINT SWITCH

Housing: Cast aluminium, stoving enamel 8P2­ TWO PUMP CONTROL (1 RELAY FOR EACH POINT)

painted suitable for back panel / 921­ THREE­POINT LEVEL SWITCH

wall mounting in safe area 9P1­ ONE PUMP CONTROL + 2 POINT SWITCH

Protection: IP­65 9P2­ SINGLE POINT + TWO PUMP CONTROL

Cable Entries: 3 * 1/2" NPT, DC gland brass 9P3­ 3 PUMP CONTROL

nickel plated ENCLOSURE

Outputs in Models: W­ WEATHER PROOF SQUARE

SLW 121: 1 * SPDT Relay rated at 6A at PF­ FLAMEPROOF PROBE HEAD ONLY

230V AC for non­inductive loads SERVICE TEMPERATURE

SLW 821: 2 * SPDT Relay rated at 6A at S­ STANDARD UPTO 80°C

230V AC for non­inductive loads H2­ HIGH TEMPERATURE 150­ 250°C

SLW 921: 3 * SPDT Relay rated at 6A at POWER SUPPLY

230V AC for non­inductive loads A­ 230 VAC

Mains: 24 V DC B­ 110 VAC

Fail­safe Mode: Field­selectable (High and Low) C­ 24 VDC

Dimensions: 215 mm * 195 mm * 85 mm PROBE TYPE

Temperature: Operating: ­20°C to 60°C RD­ ROD PROBE

Power Consumption: 0.5 W (maximum) RP­ ROPE PROBE

PROBE MOUNTING ARRANGEMENT

Probe T­ THREADED

Type: PTFE Insulated Rod / Rope F­ FLANGED

probe SS 316 O­ OTHER

Housing: Pressure die­cast aluminium INSULATED MATERIAL

weatherproof stoving enamel PV­ PVC

painted PT­ PTFE (TOTAL TEFLON)

Cable Entries: 1 * 1/2" NPT, DC gland brass WETTED PARTS

nickel plated MS­ MS (PLATED)

Probe Orientation: Top mounting S4­ SS 304

Probe Temperature: Standard: Up to 80°C S6­ SS 316SL

Insulation: Part­PTFE (Tip up to 50mm) SL­ SS 316L

Mounting Connection: Screwed 1 1/2" BSP, Slip on HC­ HASTLE ALLOY C

Flange 2" ASA, 10mm thick (with PC­ PTFE COATED

nut, bolt and gasket) SLW 121 W S A RD T PV MS

Probe Length: As per requirement

Connect to us