DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It i76s designed with a matching indoor coil com-
ponent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
TECHNICAL GUIDE • Small Footprint - The compact footprint is a perfect fit for
LX SERIES any application.
• Quality Condenser Coils - The coil is constructed of copper
SPLIT-SYSTEM HEAT PUMPS tubing and enhanced aluminum fins for increased perfor-
13 SEER – R-410A – 1 PHASE mance.
• Coil Protection - Coils are protected from damage by a slot-
1.5 THRU 5 NOMINAL TONS ted, stamped steel coil guard.
MODELS: YHJD18 THRU 60 • Protected Compressor - Compressors are protected inter-
nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high pressure switch. A
factory installed liquid line filter-drier further protects the com-
pressor against moisture and debris.
• Environmentally Friendly Refrigerant - The next genera-
tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.
• Durable Finish - The cabinet is made of G90-equivalent pre-
painted steel, with special primer formulas and matte cham-
pagne texture to insure less fading when exposed to sun-
light. The coated steel wire fan guard and pre-treated,
galvanized steel chassis components resist corrosion and
rust creep.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit is factory charged for a 15-foot lineset. The small base
dimension means less space is required on the ground or
roof.
• Top Discharge - Warm air from the top mounted fan is blown
up, away from the structure and any landscaping. This allows
compact location on multi-unit applications.
• Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
® rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the condenser coil muffle the nor-
mal fan motor and compressor operating sounds.
• Low Maintenance - Long life, permanently lubricated motor-
Due to continuous product improvement, specifications bearings need no annual servicing.
are subject to change without notice.
• Easy Service Access - Fully exposed refrigerant connec-
Visit us on the web at tions and a single panel covering the electrical controls make
www.upgnet.com and www.york.com for easy servicing of the unit.
Additional rating information can be found at • Secured Service Valves - Secured, re-usable service
www.ahridirectory.org valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
WARRANTY SUMMARY* • Agency Listed - Safety certified by CSA to UL 1995 / CSA
Standard 5-Years limited parts warranty. 22.2. Performance certified to ANSI/AHRI Standard 210/240
Standard 10-Years limited compressor warranty. in accordance with the Unitary Small Equipment certification
program.
Extended 10-Years limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
A 42 40-1/4 34 34
7/8
48 40-1/4 34 34
60 40-1/4 34 34 7/8*
* Adapter fitting required for 1-1/8" line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
B Overall length and width include screw heads.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
COIL COOLING
CFM RANGE NET MBH
UNIT MODEL RATED
MODEL WIDTH (Min.-max.) SEER1 EER
CFM TOTAL SENS.
13 SEER HP COIL ONLY RATINGS
FC/MC/PC18 14.5,17.5 450 - 750 600 18.0 14.0 13.00 11.00
FC/MC/PC24 14.5,17.5 450 - 750 600 18.0 14.0 13.50 11.00
YHJD18S41S2 FC/MC/PC30 14.5,17.5 450 - 750 600 18.0 13.7 13.00 11.00
UC24 14.5,17.5 450 - 750 600 18.0 13.8 13.05 11.00
UC30 14.5,17.5 450 - 750 600 18.0 13.8 13.05 11.00
FC/MC/PC32 14.5 600 - 1000 800 23.8 17.1 13.00 11.00
FC/MC/PC35 17.5,21.0 600 - 1000 800 23.6 17.1 13.00 11.00
YHJD24S41S4
FC/MC/PC37 14.5 600 - 1000 800 24.0 17.3 13.00 11.00
FC/MC/PC43 17.5,21.0 600 - 1000 800 24.0 17.3 13.00 11.00
FC/MC/PC32 14.5 800 - 1200 1000 29.8 21.8 13.00 11.00
FC/MC/PC35 17.5,21.0 800 - 1200 1000 29.8 21.8 13.00 11.00
YHJD30S41S4
FC/MC/PC37 14.5 800 - 1200 1000 30.0 22.2 13.00 11.00
FC/MC/PC43 17.5,21.0 800 - 1200 1000 30.0 22.2 13.00 11.00
FC/MC/PC37 14.5 1000 - 1400 1200 36.0 26.8 13.00 11.00
FC/MC/PC43 17.5,21.0 1000 - 1400 1200 36.0 26.6 13.00 11.00
YHJD36S41S4
FC/MC/PC48 21.0,24.5 1000 - 1400 1200 36.0 26.6 13.00 11.00
UC48 21.0,24.5 1000 - 1400 1200 36.0 26.8 13.00 11.00
FC/MC/PC60 21.0,24.5 1200 - 1600 1400 41.0 31.8 13.00 11.00
YHJD42S41S4
UC60 21.0,24.5 1200 - 1600 1400 40.5 31.0 13.00 11.00
FC/MC/PC60 21.0,24.5 1400 - 1800 1600 44.0 33.4 13.00 11.00
YHJD48S41S4 FC/MC62 24.5 1400 - 1800 1600 44.5 33.8 13.00 11.00
UC60 21.0,24.5 1400 - 1800 1600 44.0 32.8 13.00 11.00
FC/MC62 24.5 1600 - 2000 1800 57.5 41.0 13.25 11.35
YHJD60S41S5
FC64 24.5 1600 - 2000 1800 56.5 42.5 13.00 11.00
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)
HEATING2
UNIT COIL1
MODEL 47 F 17 F HSPF
MODEL
MBH COP KW MBH COP KW STD
13 SEER HP COIL ONLY RATINGS
FC/MC/PC18 18.0 3.36 1.50 12.7 2.16 1.24 8.20
FC/MC/PC24 18.0 3.36 1.45 10.4 2.60 1.17 8.20
YHJD18S41S2 FC/MC/PC30 18.0 3.42 1.54 11.4 2.18 1.53 7.75
UC24 18.0 3.42 1.54 11.4 2.20 1.52 7.75
UC30 18.0 3.42 1.54 11.4 2.20 1.52 7.75
FC/MC/PC32 24.0 3.36 2.09 13.9 2.38 1.71 7.70
FC/MC/PC35 23.8 3.32 2.10 13.9 2.36 1.73 7.70
YHJD24S41S4
FC/MC/PC37 24.0 3.44 2.04 14.1 2.42 1.71 7.70
FC/MC/PC43 24.0 3.44 2.04 14.1 2.42 1.71 7.70
FC/MC/PC32 27.4 3.28 2.45 16.0 2.30 2.04 7.70
FC/MC/PC35 27.4 3.28 2.45 16.0 2.30 2.04 7.70
YHJD30S41S4
FC/MC/PC37 28.0 3.38 2.43 16.1 2.32 2.03 7.70
FC/MC/PC43 28.0 3.38 2.43 16.1 2.32 2.03 7.70
FC/MC/PC37 34.4 3.42 2.95 22.4 2.62 2.51 7.70
FC/MC/PC43 34.6 3.40 2.98 22.2 2.60 2.50 7.70
YHJD36S41S4
FC/MC/PC48 34.8 3.44 2.96 22.6 2.64 2.51 7.70
UC48 35.0 3.52 2.91 22.4 2.62 2.51 7.70
FC/MC/PC60 40.5 3.72 3.19 23.0 2.50 2.70 7.70
YHJD42S41S4
UC60 40.0 3.68 3.18 22.8 2.48 2.69 7.70
FC/MC/PC60 46.0 3.58 3.76 27.4 2.76 2.91 7.70
YHJD48S41S4 FC/MC62 46.0 3.54 3.81 27.4 2.76 2.91 7.70
UC60 46.0 3.56 3.79 27.4 2.74 2.93 7.70
FC/MC62 58.0 3.44 5.24 39.5 2.66 4.35 7.80
YHJD60S41S5
FC64 58.0 3.36 5.49 40.5 2.76 4.30 7.80
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during
the same period.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
Size Test Condition 63 125 250 500 1000 2000 4000 8000 dBA SQI
Cooling Mode 67 71 66 69 65 59 58 55 70 19.2
18
Heating Mode 68 70 66 68 67 61 60 57 71 19.2
Cooling Mode 68 70 67 69 72 65 66 62 75 19.0
24
Heating Mode 69 69 63 67 67 64 65 62 72 19.1
Cooling Mode 73 70 69 71 72 66 69 63 76 19.2
30
Heating Mode 71 73 69 71 73 68 65 62 76 19.1
Cooling Mode 72 73 71 72 73 67 66 63 76 19.0
36
Heating Mode 70 72 69 70 71 69 65 64 75 19.2
Cooling Mode 71 71 73 73 72 67 67 64 77 19.1
42
Heating Mode 71 71 71 72 72 69 69 65 77 19.1
Cooling Mode 72 71 68 69 66 62 57 53 71 19.1
48
Heating Mode 71 73 70 72 70 68 65 63 75 19.1
Cooling Mode 69 69 69 70 70 65 64 63 74 19.2
60
Heating Mode 68 69 68 69 71 65 63 62 74 19.0
Rated in accordance with ARI Standard 270.
TYPICAL INSTALLATION
TO INDOOR COIL
NOTES:
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. CONTROL
MINIMUM 24” UNIT TO UNIT CLEARANCE. ACCESS
SEAL OPENING(S) WITH
PANEL
PERMAGUM OR EQUIVALENT
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
THERMOSTAT INDOOR UNIT OUTDOOR UNIT
LOW VOLTAGE TERMINAL BLOCK 3,4 DEFROST
IN AIR HANDLER WITH ELECTRIC HEAT CONTROL
R R RED
R CONTACTOR
C BLK
B or C C
Y Y YEL T2 T1
Y
O O ORG M
O
WHT GND.
W W2 W L2 L1 SCREW
L or X PUR
X/L
G G BRN W1/66
1 FIELD
T
2
W1
INSTALLED
E
2
JUMPER BK