8226-0002-0050 Rev E
8226-0002-0050 Rev E
8226-0002-0050 Rev E
Figure 1: Model 8226 with Optional Mounting Bracket Spectracom offers a Surge Protector Grounding Kit, part number 8226-0002-0600, that serves as a single point ground connection for the Model 8226 GPS Antenna Surge Suppressor. The kit includes a copper grounding plate on melamine-covered particle board, mounting hardware, copper strapping, strap clamps, ground wire, a ground clap, copper paste, an appropriate mounting bracket, and ancillary hardware. A single point ground system is recommended to provide optimum protection from lightning strikes. Mount the grounding panel indoors, preferably close to where the antenna coax enters the building and direct access to the system ground is available. Refer to Figure 2 for installation guidelines. The grounding panel must be connected to a low impedance (both low resistance and low inductance) ground system to assure proper operation of the surge protection equipment. To minimize the inductance between the ground plate and system ground interconnection, keep the copper grounding strap as straight as possible. Limit bends to a radius of 8 inches or larger. Thoroughly clean the copper panel to remove any oxidation or contaminants prior to installation. Apply the supplied copper paste to all junctions on the copper panel to maintain a lowimpedance connection.
USA +1.585.321.5800
Each Model 8226 includes two clamp type male N connectors. These connectors can be used to splice the Model 8226 into the antenna coax. The connectors are compatible with Spectracom CAL7xxx cable assemblies and Times Microwave LMR-400 equivalent coax. Connector assembly instructions are shown in the following pages.
USA +1.585.321.5800
Page 2 of 4
Tools Required Sharp Knife or Razor Blade Cable Cutter Soldering Iron and Solder Ruler Wire Cutters/Scissors 5/8 Open End Wrench 11/16 Open End Wrench Multimeter
Step 1
Cut the cable end squarely and place the nut, washer, and gasket onto the cable as shown. Make certain the gaskets V groove is oriented towards the end of the cable. Cut the cable jacket back to dimension A of 0.460 inches (11.7 mm). Do not cut or knick the braid.
Step 2
Comb out the braid and fold it back to expose the dielectric. Cut the dielectric back to dimension B of 0.234 inches (6.0 mm). Do not cut or knick the center conductor.
Step 3
Comb the braid forward and slide the clamp onto the cable as shown. Make certain that the beveled edge of the clamp is oriented towards the gasket V groove to form a weatherproof seal.
USA +1.585.321.5800
Page 3 of 4
Step 4 Fold the braid back over the clamp. Comb the braid to evenly distribute it over the clamp and trim to the proper length as shown.
Step 5 Verify that there is no braid or dielectric foil that may short against the center conductor. Tin the center conductor and then solder on the male contact as shown.
Step 6 Insert the cable assembly into the connector body. Verify the gasket V grooves fit into the clamp edges. Hold the body with the 11/16 wrench and tighten the nut using the 5/8 wrench. Using the multimeter, measure continuity of the center conductors on each end of the cable. It should be close to 0 . Measure the continuity between the center conductor and connector body. It should be an open circuit.
ECN
2017 2333 2621 2715
Description
Legacy documentation Reformatted instructions for latest style standards. Made minor text edits throughout. Added reference to Grounding Kit, 8226-0002-0600. Updated Figure 1 to accurately represent new hardware. Minor maintenance & adjustments made to reflect hardware changes (cable jacket dimensions). Update Figure 1, additional minor document maintenance.
Date
USA +1.585.321.5800