100% found this document useful (1 vote)
3K views2 pages

41 WMM Gradation

The document is a gradation test report for wet mix macadam (WMM) from a highway construction project in Madhya Pradesh, India. It lists the project details, parties involved, sample information including location and date, sieve sizes tested, and results including weight retained and cumulative percentages retained. The test was conducted to check if the gradation of the WMM sample met the specified limits according to Indian standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views2 pages

41 WMM Gradation

The document is a gradation test report for wet mix macadam (WMM) from a highway construction project in Madhya Pradesh, India. It lists the project details, parties involved, sample information including location and date, sieve sizes tested, and results including weight retained and cumulative percentages retained. The test was conducted to check if the gradation of the WMM sample met the specified limits according to Indian standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

FORM NO - QAP/QCF/RATAPANI/41

National Highways Authority of India


Project - :- Four Lanning Of Ratapani Stretch From Kms. 8+300 To Kms.20+680 (Length 12+380 Kms.) Of Obedullaganj- Itarsi
Section Of Nh-46 (Old Nh-69) In The State Of Madhya Pradesh.

EPC CONTRACTOR AUTHORITY ENGINEER CLINT

M/s Bansal Construction Work Pvt Ltd Lion Engineering Consultant Pvt Ltd National Highways Authority of India

GRADATION OF WET MIX MACADAM (WMM)

(AS PER MORTH TABLE 400-11)

Sample No. : Date of Sampling :

Location of Sampling : Date of Testing :

Source of Material : :
Location

Type of Mix Layer

wt. OF Sample :

Specified Limits
IS Sieve Size Weight Retained Cumulative wt. Cumulative %
% Passsing
(gm) Retained (gm) Retained
As per MOST
(mm)
53 100

45 95-100

22.4 60-80

11.2 40-60

4.75 25-40

2.36 15-30

0.600 8-22

0.075 0-8

Tested By (For EPC Contractor ) Checked By (Authority Engineer)