QEM - CONTROL BOXES FOR 4” SINGLE-PH. BOREHOLE PUMPS


MODEL CODE MOTOR POWER CAPACITOR RATED
(P2) CURRENT
Single-phase kW HP CAPACITANCE A
QEM 050 530ECN05A1 0.37 0.50 20 µF 5
QEM 075 530ECN07A1 0.55 0.75 25 µF 6
QEM 100 530ECN10A1 0.75 1 35 µF 7
QEM 150 530EC15A1 1.1 1.5 40 µF 11
QEM 200 530ECN20A1 1.5 2 60 µF 13
QEM 300 530EC30A1 2.2 3 75 µF 18

•• Single-phase 230 V 50 Hz

QET - CONTROL BOXES FOR 4” AND 6” THREE-PH. BOREHOLE PUMPS


MODEL CODE MOTOR POWER RATED
(P2) CURRENT
Three-phase kW HP A
QET 050 530TNF05A 0.37 0.50 1.7
QET 075 530TNF07A 0.55 0.75 2
QET 100 530TNF10A 0.75 1 2.5
QET 150 530TNF15A 1.1 1.5 3.9
QET 200 530TNF20A 1.5 2 4.8
QET 300 530TNF30A 2.2 3 7
QET 400 530TNF40A 3 4 9
QET 550 530TNF55A 4 5.5 11.5
QET 750 530TNF75A 5.5 7.5 15.5
QET 1000 530AD100A 7.5 10 21.5
QET 1250 530AD125A 9.2 12.5 23.5
QET 1500 530AD150A 11 15 27.5
QET 2000 530AD200A 15 20 36
QET 2500 530AD250A 18.5 25 45
QET 3000 530AD300A 22 30 54
QET 4000 530AD400A 30 40 68

•• The control box is fitted with a selector for manual or automatic operation with the
possibility of attaching a float (or a pressure valve, etc.).
•• Three-phase 400 V 50 Hz

402
QSM - CONTROL BOXES FOR 4” SINGLE-PH. PUMPS WITH LEVEL PROBES
MODEL CODE MOTOR POWER CAPACITOR RATED
(P2) CURRENT
Single-phase kW HP CAPACITANCE A
QSM 050 530MFLCN05A1 0.37 0.50 20 µF 5
QSM 075 530MFLCN07A1 0.55 0.75 25 µF 6
QSM 100 530MFLCN10A1 0.75 1 35 µF 7
QSM 150 530MFLC15A1 1.1 1.5 40 µF 11
QSM 200 530MFLCN20A1 1.5 2 60 µF 13
QSM 300 530MFLC30A1 2.2 3 75 µF 18

Level
•• The control box is fitted with a selector for manual or automatic operation with the possibility
probes of attaching a float (or a pressure valve, etc.) and fluid level probes which protect the pump
from operating when dry.
•• Single-phase 230 V 50 Hz

QST - CONTROL BOXES FOR 4”AND 6” THREE-PH. PUMPS WITH LEVEL PROBES
MODEL CODE MOTOR POWER RATED
(P2) CURRENT
Three-phase kW HP A
QST 50 530TFLC05A 0.37 0.50 1.7
QST 75 530TFLC07A 0.55 0.75 2
QST 100 530TFLC10A 0.75 1 2.5
QST 150 530TFLC15A 1.1 1.5 3.9
QST 200 530TFLC20A 1.5 2 4.8
QST 300 530TFLC30A 2.2 3 7
QST 400 530TFLC40A 3 4 9
Level QST 550 530TFLC55A 4 5.5 11.5
probes
QST 750 530TFLC75A 5.5 7.5 15.5
QST 1000 530ADL100A 7.5 10 21.5
QST 1250 530ADL125A 9.2 12.5 23.5
QST 1500 530ADL150A 11 15 27.5
QST 2000 530ADL200A 15 20 36
QST 2500 530ADL250A 18.5 25 45
QST 3000 530ADL300A 22 30 54
QST 4000 530ADL400A 30 40 68

•• The control box is fitted with a selector for manual or automatic operation with the possibility
of attaching a float (or a pressure valve, etc.) and fluid level probes which protect the pump
from operating when dry.
•• Three-phase 400 V 50 Hz

403
CONTROL BOXES
EVOLUTION - CONTROL BOXES FOR 4” AND 6” BOREHOLE PUMPS
MODEL CODE VOLTAGE RATED
CURRENT
A
Single-phase
EVOLUTION-MONO 532DOM003M from 2 to 18
230 V 50 Hz
Three-phase
EVOLUTION-TRI/1 532DOM075T from 2 to 16
400 V 50 Hz
Three-phase
EVOLUTION-TRI/2 532DOM100T from 16 to 22
400 V 50 Hz

•• The control box contains an electronic card which makes it possible to regulate the threshold at
which the protection against power overloads and short circuits intervenes; the electronic card also
controls the value of cos φ in order to prevent dry operating of the pump without the help of fluid
level probes.
•• The control box may be connected to a float switch (or a pressure switch, etc.).

QES - CONTROL BOXES FOR SINGLE-PHASE DRAINAGE PUMPS


MODEL CODE MOTOR POWER CAPACITOR RATED
(P2) CURRENT
Single-phase kW HP CAPACITANCE A

QES 300 MONO 52VX300A1 2.2 3 60 µF 16

QES 300 MONO-AL (*) 52VX300A1AL 2.2 3 60 µF 16

•• The control box is pre-set for connection with the thermal protector inserted in the winding of the
drainage pumps VXCm30, VXCm30-F, MCm30, MCm30-F.
•• Single-phase 230 V 50 Hz
(*) QES 300 MONO-AL, control box with contacts for connection to an auxiliary float switch for
level alarm

QES - CONTROL BOXES FOR THREE-PHASE DRAINAGE PUMPS


MODEL CODE MOTOR POWER RATED
(P2) CURRENT
Three-phase kW HP A
QES 150 532QES150A 1.1 1.5 4.2
QES 200 532QES200A 1.5 2 5.2
QES 300 532QES300A 2.2 3 6.5
QES 400 532QES400A 3 4 8

•• The control box is fitted with a selector for manual or automatic operation with the possibility of
attaching a float, and with the thermal protector inserted in the winding of the drainage pumps
VXC, VXC-F, MC, MC-F
•• Three-phase 380 ÷ 415V 50 Hz

404
QED 1 - ELECTRONIC CONTROL BOX FOR ONE DRAINAGE PUMP
MODEL CODE VOLTAGE RATED
CURRENT
A
Single-phase
QED 1- MONO 533QED01M from 2 to 18
230 V 50 Hz
Three-phase
QED 1- TRI 533QED01T from 2 to 9
400 V 50 Hz

•• The control box contains an electronic card which makes it possible to regulate the value of the
current at which the protection intervenes against power overloads and short circuits.
•• The control box is pre-set for connection with the thermal protector inserted in the winding of the
drainage pumps VXC, VXC-F, MC, MC-F and of three floats (operation, stop and alarm level).

QED 2 - ELECTRONIC CONTROL BOX FOR TWO DRAINAGE PUMPS


MODEL CODE VOLTAGE RATED
CURRENT
A
Single-phase
QED 2- MONO 533QED02M from 2 to 18
230 V 50 Hz
Three-phase
QED 2- TRI 533QED02T from 2 to 9
400 V 50 Hz

•• The control box contains an electronic card which makes it possible to regulate the value of the
current at which the protection intervenes against power overloads and short circuits.
•• The control box is pre-set for connection with the thermal protector inserted in the winding of the
drainage pumps VXC, VXC-F, MC, MC-F of four floats (successive operation of the first pump, operation
of the second pump, stop and alarm level).