Safety Precautions is for using the product safely and correctly in order to prevent Read this data sheet carefully prior to any operation, mounting, installation or 1. Introduction
accidents and danger, so always follow the instructions.
start-up of the product.
DATASHEET The precautions explained here only apply to Smart I/O Series. This datasheet provides brief information about characteristics, configurations,
* MasterLogic-50 Series is available on SoftMaster Ver1.2 or later.
For safety precautions on the PLC system, refer to MasterLogic PLCs User’s manual.
and usages of MasterLogic-50 PLC FEnet I/F Module(MLL-EMTA).
The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the
meanings is represented as follows. Name ML50 Fast Ethernet I/F Module Datasheet 2. General Specifications
If violated instructions, it may cause death, fatal injury or a Code 10310000864
MasterLogic-50 Series Warning considerable loss of property. It describes the General Specifications for of MasterLogic-50 PLC .
FEnet I/F Module Caution
If violated instructions, it may cause a slight injury or a slight Revision History No. Item Specification Standard
loss of property. Operating
1 0 ~ 55C
The symbols which are indicated in the PLC and User’s Manual mean as follows. Publication Version Description temperature
MLL-EMTA 2007. 8 Ver. 1.0 The First Edition 2 Storage temperature -25 ~ 70C
Give warnings and cautions to prevent from risk of injury, fire, or malfunction. 2014.05 Ver1.1 Revised Address 3 Operating Humidity 5 ~ 95%RH, non-condensing
4 Storage humidity 5 ~ 95%RH, non-condensing
Give warnings and cautions to prevent from risk of electric shock.
Occasional vibration
Store this datasheet in a safe place so that you can take out and read whenever Sweep
Frequency Acceleration Amplitude
necessary. Always forward it to the end user. count
10≤f∠57 Hz - 0.075 mm
10 times
5 Vibration 57 ≤f≤150 Hz 9.8 ㎨(1G) -
Warning Continuous vibration
in each IEC61131-2
direction
Frequency Acceleration Amplitude
Do not contact the terminals while the power is applied. for
10≤f∠57 Hz - 0.035 mm
Risk of electric shock and malfunction. X, Y, Z
57≤f≤150 Hz 4.9 ㎨(0.5G) -
Do not drop or insert any metallic object into the product. *Maximum shock acceleration: 147 ㎨(15G)
*Duration time :11 ms
Risk of fire, electric shock and malfunction. 6 Shocks IEC61131-2
*Pulse wave: half sine wave pulse
Do not charge, heat, short, solder and break up the battery. ( 3 times in each of X, Y and Z directions )
Square wave
Risk of injury and fire by explosion and ignition. ±900 V
impulse noise
Electrostatic IEC61131-2
Voltage :4kV(contact discharge)
discharge IEC61000-4-2
Caution Radiated
electromagnetic 27 ~ 500 MHz, 10 V/m
IEC61131-2
7 Noise immunity IEC61000-4-3
field
Ensure to check the rated voltage and terminal arrangement for
Digital/Analog I/O
the module before wiring work. Power
10310000864 Printed in Korea Fast transient Class communication IEC61131-2
Risk of electric shock, fire and malfunction. module
burst noise interface IEC61000-4-4
Tighten the screw of terminal block with the specified torque range. Voltage 2kV 1kV
Risk of fire and electric shock if the terminal screw looses. 8 Atmosphere Free from corrosive gases and excessive dust
9 Altitude for use Up to 2,000m
Use the PLC in an environment that meets the general 10 Pollution level 2 or lower
specifications contained in this datasheet. 11 Cooling method Self-cooling
Risk of electrical shock, fire, erroneous operation and deterioration of the PLC.
Remark
Ensure that external load do not exceed the rating of output module.
1) IEC (International Electro-technical Commission):
Risk of fire and erroneous operation.
For more information on MasterLogic PLCs , contact your nearest Honeywell office . An international nongovernmental organization which promotes internationally cooperated
Do not use the PLC in the environment of direct vibration standardization in electric/electronic fields, publishes international standards and manages
Australia Japan Singapore
Honeywell Ltd. Honeywell Inc. Honeywell Pte Ltd. Risk of electrical shock, fire and erroneous operation. applicable estimation system related with.
Phone : (61) 2-9353-4500 Phone: (81)3-5440-1395 Phone: (65) 6355-2828
Fax : (61) 2-9353-7677 Fax: (81)3-5440-1368 Fax: (65) 6445-3033 2) Pollution degree:
Do not disassemble, repair or modify the PLC. An index indicating pollution level of the operating environment which decides insulation
China South Korea Thailand
Honeywell (Tianjin) Ltd. – Beijing Honeywell Co., Ltd. Honeywell Systems Ltd. Risk of electrical shock, fire and erroneous operation. performance of the devices. For instance, Pollution level 2 indicates the state generally that
Phone: (86-10) 8458-3280 Phone : (82) 2-799-6114 Phone: (662) 693-3099
Fax: (86-10) 8458-3102 Fax : (82) 2-792-9015 Fax: (662) 693-3085 only non- conductive pollution occurs. However, this state contains temporary conduction
When disposing of PLC and battery, treat it as industrial waste.
Honeywell (Tianjin) Ltd. – Shanghai Malaysia Taiwan due to dew produced.
Phone: (86-21) 6237-0237 Honeywell Engineering Sdn Bhd. Honeywell Taiwan Ltd. Risk of poisonous pollution or explosion.
Fax : (86-21) 6237-3102 Phone: (603) 7958-4988 Phone: (886) 2-2245-1000
Fax: (603) 7958-8922 Fax: (886) 2-2245-3241
Indonesia 3. Performance Specification
PT Honeywell Indonesia New Zealand For Countries (SE Asia) Listed
Phone : (62) 21-535-8833 Honeywell Ltd. below, call Honeywell Singapore
Fax : (62) 21-5367-1008 Phone: (64-9) 623-5050 Office It describes the Performance Specification for of MasterLogic-50 PLC FEnet
Fax: (64-9) 623-5060 Pakistan, Cambodia, Laos,
India Myanmar, Vietnam and East Timor I/F module.
Honeywell Automation India Ltd. Philippines Precautions for use
Phone: (91) 20-5603-9400 Honeywell Systems Inc. For Countries Listed below, Items Performance
Fax: (91)-20-5603-9800 Phone: (63-2) 633-2830 call Honeywell India Office Do not install in places other than PLC controlled place.
Fax: (63-2) 638-4013 Bangladesh, Nepal, and Sri Lanka Ensure that the FG terminal is grounded with class 3 grounding which is dedicated to the PLC.
Speed 10/100Mbps
Otherwise, it may cause disorder or malfunction of the PLC.
Transfer System
Base Band
PLC Others PLC Others PLC Others Max. extended distance
-
of Station-to-Station
100m
Max. Segment Length.
< Best > < Good > < Bad > (Node-Hub)
Honeywell Process Solution Max. Node No. Able to link to 9 hub stages (Recommended)
Transfer Node Interval -
Connect expansion connector correctly when expansion modules are needed.
HFS Asia Pacific Spec.
Do not detach PCB from the case of the module and do not modify the module. Max. Protocol Vol. 512Byte
Honeywell Building Turn off the power when attaching or detaching module. Excess Method of
CSMA/CD
17 Changin Business Park Central 1
Cellular phone or walkie-talkie should be farther than 30cm from the PLC. Communication Range
Input signal and communication line should be farther than minimum 100mm from a Frame Error Check 15 14 13
CRC16 = X + X + X + ... + X + X + 1
2
Singapore 486073 high-tension line and a power line in order not to be affected by noise and magnetic
Number of Max.
www.honeywellprocess.com/ field. Installation module 2
8. Dimension
Unit : mm
8 pin RJ-45
connector