1. SPECIFICATIONS
1.1 Features
1.2 Mechanical Specifications
1.3 Absolute Maximum Ratings
1.4 DC Electrical Characteristics
1.5 Optical Characteristics
2. MODULE STRUCTURE
2.1 Counter Drawing
2.2 Interface Pin Description
2.3 Timing Characteristics
2.4 Display Command
3. QUALITY ASSURANCE SYSTEM
3.1 Quality Assurance Flow Chart
3.2 Inspection Specification
4. RELIABILITY TEST
4.1 Reliability Test Condition
5. PRECAUTION RELATING PRODUCT HANDLING
5.1 Safety
5.2 Handling
5.3 Storage
5.4 Terms of Warranty
1. SPECIFICATIONS
1.1 Features
Item Standard Value
Backlight -
Weight -
Other -
Humidity HD - - 90 %RH
VDD=+5V+10%,V SS=0V,TA=25°C
Item Symbol Condition Min. Typ. Max. Unit
Logic Supply voltage VDD - 4.5 5 5.5 V
“H” input voltage VIH - 2.2 - VDD V
“L” input voltage VIL - -0.3 - 0.6 V
“H” output voltage VOH IOH=-0.205mA 2.4 - VDD V
“L” output voltage VOL IOL=1.2mA - - 0.4 V
Supply current IDD VDD=5V - 1.5 2.5 mA
VDD-VO(0℃) - - -
LCD driving voltage VOP VDD-VO(25℃) 4.3 4.5 4.7 V
VDD-VO(50℃) - - -
∅
Z’ θ1 θ2
Y(∅=0°)
Light (when transmitted ) viewing angle θ (∅ fixed)
(θ=90°)
Note : Optimum viewing angle with the
naked eye and viewing angle θ at
Cmax. Above are not always the same
C =
Brightness (reflection) of selected dot (B1)
Brightness (reflection) of
selected dot
(%)
Brightness
(reflection) of
B2 unselected dot
Brightness
(reflection) B1
2. MODULE STRUCTURE
2.1 Counter Drawing
15 A NC
16 K NC
Contrast Adjust
VDD
2
VO
3 LCD MODULE
10~20KΩ
VSS 1
• Read cycle
RS VIH1
VIL1
t SU tH
VIH1 VIH1
DB0-DB7 Valid Data
VIL1 VIL1
tC
• Write cycle
RS VIH1
VIL1
t SU1 t H1
VIH1 VIH1
DB0-DB7 Valid Data
VIL1 VIL1
tC
• Read cycle
VDD=4.5V~5.5V,Ta=25℃
Characteristics Symbol Min. Typ. Max. Unit
E Cycle Time tC 500 - - ns
E Rise / Fall Time tR,tF - - 20 ns
E Pulse Width (High, Low) tW 230 - - ns
R/W and RS Setup Time tSU 40 - - ns
R/W and RS Hold Time tH 10 - - ns
Data Output Delay Time tD - - 120 ns
Data Hold Time tDH 5 - - ns
• Write cycle
Info. Survey
Marketing
& Request Inquiry Design evaluation
Design
Quote
Contract
Design check
Sample
Approval Sample test
Sample approval
Inspection
Shipment
Ship Out
Ship out
Info. Claim
Failure analysis
Sales
Analysis report
Service
Corrective action
Tracking
Assembly parts
10 N.G. Minor
A=( L + W )÷2
D Pad
4. RELIABILITY TEST
4.1 Reliability Test Condition
Applicable
NO Item Test Condition
Standard
Storage At 80 ±2℃ 96~100 hrs
Surrounding Temperature,Then Storage
1 High Temperature Storage MIL-202E
At Normal Condition 4hrs.
5.1.2 If the liquid crystal touches your skin or clothes , please wash it off immediately by
5.2 HANDLING
5.2.1 Avoid any strong mechanical shock which can break the glass.
5.2.2 Avoid static electricity which can damage the CMOS LSI—When working with the
module , be sure to ground your body and any electrical equipment you may be
using.
5.2.4 The polarizing plate of the display is very fragile. So , please handle it very carefully ,
do not touch , push or rub the exposed polarizing with anything harder than an HB
5.2.5 Do not wipe the polarizing plate with a dry cloth , as it may easily scratch the surface
of plate.
5.2.6 Do not touch the display area with bare hands , this will stain the display area.
5.2.7 Do not use ketonics solvent & aromatic solvent. Use with a soft cloth soaked with a
5.3 STORAGE
5.3.1 Store the panel or module in a dark place where the temperature is 25℃ ±5℃
5.3.2 Do not place the module near organics solvents or corrosive gases.
The period is within thirteen months since the date of shipping out under normal
This product has been manufactured to your company’s specification as a part for
according to delivery specifications. For any other use apart from general electronic
nuclear power control equipment , aerospace equipment , fire and security systems
or any other applications in which there is a direct risk to human life and where