JA-65 Webmodule
JA-65 Webmodule
Installation manual
The JA-60WEB communicator is designed for JA-63 and JA-65 alarm control panels. The dialer is
used for communication with a central monitoring station via an Ethernet network / the internet. This
installation manual is intended for JA-60WEB version HO61303
The WEB module, when installed in the alarm control panel, enables:
• Data transfer in CID-IP format to one or two Central Monitoring Stations (CMS),
• Programming of the communicator via the web,
• Remote control of appliances via a web page – 3 outputs and 1 input
3 Communicator configuration
Communicator configuration can be done via the system keypad (the control panel must be in
programming mode). To exit programming mode, press the N key. The following settings should be
done in consultation with the network provider / supervisor. Default settings and backup can also be
made by Locator software, which can be found on www.jablotron.com.
3.1 Automatic assignment of IP address (DHCP)
Before attaching the communicator to the LAN network, it is necessary to determine the assignment
of IP address. If DHCP is disabled it is necessary to set parameters according to sequences 3.2, 3.3
and 3.4.
Example: to set Net mask 255.255.255.1 enter 92 255 255 255 001
Example: to set Gateway IP address 192.168.33.1 enter 93 192 168 033 001
4.1.1 Panel
In the panel page the user can:
Monitor the control panel
Operate Hot keys for controlling the control panel quickly
Enter programming or operating sequences in the Sequence input field
See the status and operate the outputs (AUX1-AUX3) and see the status of the input (INP)
4.1.2 Events
To see the 127 latest events
4.1.3 Communicator
In the communicator page the user can:
Configure the network settings such as DHCP, IP address, Netmask and gateway
Set the Idle time for auto logoff, and HTTP port
Set the Function of the input (off - the status of the input will be only shown in the Panel
Page, tamper – when connected to GND, the control panel will trigger the tamper alarm)
Customize Login Name and Password
4.1.4 Control panel
This page is accessible only when the control panel is in programming mode (P). It enables full
setting of the control panel. A detailed description of the parameters can be found in the control
panel manual.
5 Specification
Power supply 12V DC provided by the alarm control panel
Current consumption 40 mA
AUX outputs dry contact, max. 100mA / 60V
INP input reacts to connection to GND, max. voltage 15V
Complies with EN 50131-1, Z1, EN 50136-1
Security grade 2 (low to medium risk)
Enviromental class II indoor-general ( –10 to 40°C)
Safety EN 60950
EMC EN 55022, EN 55024, EN 50130-4
Hereby, Jablotron Ltd., declares that this JA-60WEB is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. (NV 426/2000Sb.)
Original of the conformity assessment can be found at the web page
www.jablotron.com, section Technical support.