0% found this document useful (0 votes)
56 views

Graph

The document summarizes the results of a particle size distribution test on a coarse aggregate sample. It shows that 44.17% of the sample was retained on the 16mm sieve. The D60 particle size was 17.36mm, the D30 was 13.11mm, and the D10 was 7.9mm. The uniformity coefficient (D60/D10) was 2.2.

Uploaded by

aneeshp_4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Graph

The document summarizes the results of a particle size distribution test on a coarse aggregate sample. It shows that 44.17% of the sample was retained on the 16mm sieve. The D60 particle size was 17.36mm, the D30 was 13.11mm, and the D10 was 7.9mm. The uniformity coefficient (D60/D10) was 2.2.

Uploaded by

aneeshp_4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Particle Size Distribution-CA

100
90
80 CA- Test Sample

70
% Passing

60
50
40
30
20
10
0
1 10
Sieve size in mm

Coarse Aggregate
Weight % Weight % Weight Cummulative % wt
IS Seive Seive Size
retained retained passing retained
25mm 25 0.048 1.61 98.39 1.61
20mm 20 0.276 9.25 89.14 10.86
16mm 16 1.318 44.17 44.97 55.03
12.5mm 12.5 0.54 18.1 26.87 73.13
10mm 10 0.259 8.68 18.19 81.81
6.3mm 6.3 0.431 14.44 3.75 96.25
4.75mm 4.75 0.085 2.85 0.9 99.1
Pan 0.027 0.9 0 100
Total 2.984 100
Result
D60 17.36 D60/D10 2.2
D30 13.11
D10 7.9