Allengers 525 FC-FT-VB
Allengers 525 FC-FT-VB
Allengers 525 FC-FT-VB
PHOTOGRAPH OF EQUIPMENT
Output Power 40 KW
mA Output 500 mA
KV Range 40-125 KV
mAs Range 1.0 to 200 mAs
Exposure Time 5.0 Sec
CONTROL Consisting of Push to On & OFF Switches, with Voltmeter, mA meter,
Quick trip-overload circuit breaker (Automatic safety system to block
unwanted exposure factors beyond Tube Rating), Voltage Compensator,
Major & Minor KV selector, Tube overload indicator provided. Digital
Display of active KVP & mAs. Electronic overload for protection of tube
H.V. Cables & H.T. Tank. Independent Fluoro KVP Selector. In built Ready
& X-Ray Switch on Control.
Compact Heavy Duty Transformer comprising HV Silicon Rectifiers, HT
HV TRANSFORMER
Transformer, Filament Transformer, Federal Bushings all immersed in oil.
Hand Switch with Flexible long cord enables the operator to keep away
from the Radiation area during exposure.
ACCESSORIES
- Aluminum Filter.
- Light Beam Diaphragm.
One Canon (E7239X) Rotating Anode Tube Unit with Dual Focus X-Ray
TUBE UNIT Tube inserts having small Focal Spot 1.0 mm and Large 2.0mm.
ANODE HEAT STORAGE CAPACITY: 140KHU
One Pair of 8 meter High Voltage Cables:
HV CABLE
Sleevings - Straight.
STAND (FC) Floor to Ceiling Stand & with Counter Balanced Tube Head (Rotatable ±
180 Degree), 360 Degree Rotatable; mounted on Floor Ceiling Rails for
convenient movements.
Mechanical Specifications:
1. Longitudinal Movement of Column on Rail: 2950 mm
2. Horizontal Coverage of tube head:445 mm
3. Vertical Carriage Up down movement: 1410 mm
4. Maximum height of Focal Spot from Floor:2000 mm
5. Minimum height of Focal Spot from Floor:500 mm
6. Tube Head rotation : +180o
7. Column rotational : +180o
8. Minimum Recommended Height of Room: 2743 mm
FLOATEX Allengers Floatex table is having a floating table top in 4 directions.
➢ Provided with 2-dimensional movement of table top
➢ Manual Transverse & Longitudinal movements with electromagnetic
locking.
➢ Table is provided with Bucky beneath the table top having manual
movement which is electromagnetically locked and needs to be unlocked
by the foot switch for its movement.
Mechanical Specifications:
• Length of the table top: 2000mm
• Width of the table top: 720mm
• Longitudinal movement of the table: 535mm
• Transverse movement of the table: 200 mm
Available grids: 8:1, 85 lines/inch
VERTICAL BUCKY STAND Vertical Bucky Stand having Bucky with motorized oscillating grid of Ratio
8:1, 85 lines. The Bucky moves up & down & are equipped with a
stainless steel cassette. This stand is floor mounted type & can
accommodate cassettes up to 14” x 17”.
MECHANICAL SPECIFICATIONS:
1. Stand Dimension (LxWxH): 887 x 652 x 2073 mm
2. Vertical Movement Of The Bucky: 1210 mm (without AEC)
3. Min. Height Of Bucky Center From Ground - 460 mm
4. Max. Height Of Bucky Center From Ground–1670 mm (Without AEC)
5. Bucky Rotation – 0o to 90°
6. Maximum Patient Coverage - 1640 mm (Without AEC)
7. Provision Of Manual Brakes - Yes
8. Net Weight Of Stand - 162 Kg (Appx.)
POWER SUPPLY REQUIREMENT 400-440V AC, 50 Hz, Three Phase - Max. Allowable line Regulation ±
10%.