Leica Viva TS16 DS
Leica Viva TS16 DS
Leica Viva TS16 DS
Data sheet
leica-geosystems.com
Leica TS16 Total Station
ANGLE MEASUREMENT
Accuracy 1 Hz and V n Absolute, continuous, diametrical 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon),
5’’ (1.5 mgon)
DISTANCE MEASUREMENT
Range 2 n Prism (GPR1, GPH1P) 3 0.9 m to 3,500 m
n Non-Prism / Any surface 4,9 R500: 0.9 m to >500 m
R1000: 0.9 m to >1,000 m
Accuracy / Measurement time n Single (prism) 2,5 1 mm + 1.5 ppm / typically 2.4 s
n Single (prism fast) 2,5 2 mm + 1.5 ppm / typically 1.5 s 11
n Single (any surface) 2,4,5,6 2 mm + 2 ppm / typically 2 s 7
Laser dot size At 50 m 8 mm x 20 mm
Measurement technology System analyser Coaxial, visible red laser
IMAGING
Overview camera n Sensor 5 megapixel CMOS sensor
n Field of view 19.4°
n Frame rate Up to 20 frames per second
AUTOMATIC AIMING - ATRplus
Target aiming range2 / Target locking range2 n Circular prism (GPR1, GPH1P) n 1,500 m / 1,000 m
n 360° prism (GRZ4, GRZ122) n 1,000 m / 1,000 m
Accuracy 1,2 / Measurement time ATRplus angle accuracy Hz, V 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon),
5’’ (1.5 mgon) / typically 3-4 s
LASER GUIDE
Spot Size8 / Range n Daylight: 30 mm @250 m 250 m
n Darkness: 65 mm @300 m 500 m
POWERSEARCH
Range / Search time 360° prism (GRZ4, GRZ122) 300 m / typically 5 s
GUIDE LIGHT (EGL)
Working range / Accuracy 5 - 150 m / typically 5 cm @ 100 m
GENERAL
Field Software Leica Captivate with apps
Processor TI OMAP4430 1GHz Dual-core ARM® Cortex™- A9 MPCore™
AutoHeight module for automatic n Distance accuracy 1.0 mm (1 Sigma)
instrument height measurement n Distance range 0.7 m to 2.7 m
Display and keyboard 5“ (inch), WVGA, colour, touch, face I standard / 37 keys, illumination
face II optional
Power management Exchangeable Lithium-Ion battery Operating time up to 8 h
Data storage Internal memory / Memory card 2 GB / SD card 1 GB or 8 GB
Interfaces RS232, USB, Bluetooth®, WLAN
Weight Total station including battery 5.1 - 5.8 kg
Environmental specifications n Working temperature range –20°C to + 50°C
n Dust & Water (IEC 60529) / Humidity IP55 / 95%, non-condensing
LEICA TS16 TOTAL STATIONS TS16 M TS16 A TS16 G10 TS16 P TS16 I
Angular measurement ✔ ✔ ✔ ✔ ✔
Laser Guide ✗ ✗ ✔ ✗ ✗
PowerSearch (PS) ✗ ✗ ✗ ✔ ✔
Overview camera ✗ ✗ ✗ ✗ ✔
1
Standard deviation ISO 17123-3 7
Up to 50m; max. measurement time 15 s for full range.
2
Overcast, no haze, visibility about 40 km, no heat shimmer 8
Typical laser beam diameter on white, smooth surfaces with intensity 100%
3
0.9 m to 2,000 m for 360° prisms (GRZ4, GRZ122) 9
TS16G R30: 0.9 m to 30 m
4
Object in shade, sky overcast, Kodak Gray Card (90% reflective) 10
Angle accuracies 1“ to 3“, PinPoint R30 & R1000 variants available
5
Standard deviation ISO 17123-4 11
Initial measurement time typically 2 s
6
Distance > 500m: Accuracy 4mm+2ppm, Measurement time typ. 6s
Leica Geosystems AG
Heinrich-Wild-Strasse
9435 Heerbrugg, Switzerland
+41 71 727 31 31