MODEL: "AQ-8/10"
DESCRIPTION
The fresh water maker has a distillate production capacity of 8 t/day with condensation
seawater at temp. Max. 32ºC; and engine jacket cooling water temperature between
70ºC and 95ºC (other temperatures are available under request).
The fresh water maker consists of one vessel (one stage). The condensation water,
which is supplied by seawater cooling/ejector pump at a maximum temperature of 32ºC,
enters the plant at the condenser, flows through this condenser and condensates the
vapour produced.
From the condenser outlet, the unit feeds with seawater the brine/air ejector (where
brine and air is take off), and at same time supplies the required quantity of sea water (3
times the production) to be boiled.
The pressure inside the chamber is less than atmosphere (vacuum), in this way the
boiling temperature is low, but in any way bigger than 50ºC. The vapour arise from the
brine level in the heater tube bundle, flows through the demister where atomised brine
in the vapour is separated and pure steam flows to be condensate in the condenser.
The brine level is regulated through the flow control valve and the hot box in any
condition.
As heating medium, engine jacket cooling fresh water will be used. If it is required other
heating sources can be used, please advice.
EQUIPMENT/FITTINGS/ACCESORIES/MATERIALS:
The fresh water maker AQ-8/10 is a packaged unit. All components and accessories as
distillate pump,salinometer/control panel, accessories, interconnecting pipe work are
included.
Seawater cooling/ejector pump, salinometer control panel and scale inhibitor liquid
container (30 litres) will be supplied separately.
AQ08-INF-TEC-ING 1
1.0.Vessels with inspection window CuNi 90/10
2.0.Condenser of U tube
3.0.Demisters Monel
6.0.Pipework
8.0.Brine/Air ejector
AQ08-INF-TEC-ING 2
9.0.Distillate Pump (1 H.P)
9.1. Pump type Centrifugal
9.2. Manufacturer GEFICO
9.3. Type GEF-AD-152-4-1
9.4. Capacity 1,5 m3/h
9.5. Pump head 20 m.c.w.
9.6. Speed 2810 rpm / 3420 rpm
9.7. Construction
9.7.1.- Horizontal
9.7.2.- No self priming
9.7.3.- Inlet connection: 1" BSP
9.7.4.- Outlet connection: 3/4" BSP
9.8. Materials
9.8.1.- Casing: Bronze casting
9.8.2.- Impeller: Bronze casting
9.8.3.- Shaft: Stainless steel AISI316
9.8.4.- Shaft seal: Mechanical seal
9.9.Electric motor
9.9.1.-Size: 80-KX2
9.9.2.-Power: 0,75 KW / 0,90 KW
9.9.3.-Nominal current: 1,9 Amps.
9.9.4.-Starting current: 4,8 * In
9.9.5.-Power factor: 0,84
9.9.6.-Noise level: 73 dB
AQ08-INF-TEC-ING 3
11.0.Control equipment and instrumentation
11.1. Electrical control panel, incorporating
salinometer, motor starters,
alarms, transformer and
connection for remote alarm ......... Makers stand
AQ08-INF-TEC-ING 4
TECHNICAL DATA SHEET
For Fresh Water Generator AQUAMAR AQ-8/10
1).- Type : AQ-8/10
2).- Distillate produced : 8 t/24h
3).- Heat consumption : 247 KW
4).- Performance ratio : 0,74 kwh/kg distillate
5).- Residual salt content : <4 ppm NaCl
6).- Distillate temperature : 40ºC
7).- Seawater quantity : 20 m3/h
8).- Max. Seawater temperature : 32ºC
9).- Total dissolved solids : 35000 PPM
10).-Brine quantity : 833 ltrs/h
11).-Max. Brine temperature : 50ºC
12).-Brine outlet temperature : 42ºC
13).-Brine outlet pressure(max) : 0,3 bar(g)
HEATING MEDIUM, jacket water
14).-Quantity : 20 m3/h
15).-Operating pressure : < 6 bar
16).-Inlet temperature : 70 to 90ºC
17).-Outlet temperature : Variable
EJECTOR, seawater
18).-Sea water quantity : 20 m3/h
19).-Outlet back-pressure(max) : 0,3 bar(g)
20).-Inlet pressure : 3,5 bar < P < 6 bar
DIMENSIONS OF THE UNIT
21).-Length : 1325 mm.
22).-Width : 725 mm.
23).-Height : 1000 mm.
24).-Weight empty : 394 kg
25).-Weight in operation : 534 kg
ELECTRICAL DATAS
26).-Power supplied : 400V/50hz/3 or 440V/60HZ/3
27).-Control : 220V/50-60hz
28).-Seawater pump elect.motor : 5,5 KW / 6,6 KW
29).-Freshwater pump elect.motor : 0,75 KW / 0,9 KW
30).-Salinometer and control board : 0,19 KW.
31).-Starter : D.O.L.
32).-Type: Squirrel cage, 2 pole ,tropicalized, continuous service(S1),
marine design.
33).-Insulation class : IP-55. Class F
AQ08-INF-TEC-ING 5
SAFETY NOTICE
A FIRST AID KIT SHOULD BE AVAILABLE AT ALL TIMES
REMEMBER THAT PLANT CAN BE DANGEROUS
IT MAY START WITHOUT WARNING
INSTALLATION
Before installation of the plant, operators should be aware of the contents of this
manual.
Suitable facilities, for example lifting equipment, must be provided to enable the
plant to be installed safely. Mechanical installation must be completed before
electrical connection; remember that the mixture of water and electricity can prove
fatal.
Suitable arrangements must be provided for the storage of spare parts, lubricants,
preservatives and chemical cleaning materials.
OPERATION
The control and safety system provided is necessary for the safe operation of the
plant. Any device removed or adjusted to facilitate maintenance must be replaced
and/or readjusted before the plant is returned to service.
Operators who are likely to be in contact with the machine lubricants, or the
chemicals used for protection or cleaning must be provided with, and wear,
suitable protective clothing.
MAINTENANCE
Electrical maintenance must only be undertaken by persons suitably experienced
and qualified.
Ensure that electrical supplies are properly isolated before undertaking any
maintenance procedure.
AQ08-INF-TEC-ING 6
The supply should be disconnected by operation of the main switch, circuit
breakers, removal of fuses or other acceptable method. A notice should be placed
at the point of isolation showing:
DANGER
WORK IN PROGRESS
Place a free space surrounding the unit to facilitate the working. Make sure that
you have a clear path of retreat.
Check the explosion risk before using welding equipment or electrical hand tools.
When working in confined spaces, make sure that no dangerous gasses are
present.
CHEMICALS
Read and observe the Health and Safety instructions provided on chemical
containers or data sheets.
Take normal precautions to avoid skin contact and the inhalation of vapors.
Provide adequate ventilation.
If a chemical substance comes into contact with the skin take immediate and
appropriate first aid action and seek medical attention.
AQ08-INF-TEC-ING 7
INSTALLATION DETAILS
The fresh water generator "AQUAMAR" must be installed as close as possible to
the heat source so as to minimize heat looses on the connection pipes between
F.W.Generator and heat source.
Minimum space must be left around the unit for maintenance works.
Pipe size and situation are showed in dimensional and flow drawings for each
Fresh Water Generator.
The seawater pump suction must be as near as possible to the sea chest to avoid
cavitations and always below seawater level (it is a not-self priming pump).
The length and elbows of this pipe will be minimum, to avoid pressure looses.
One inlet valve must be placed in the condenser inlet for insulation and pressure
regulation.
AQ08-INF-TEC-ING 8
4.2.- HEAT SUPPLY
The jacket cooling water from engine (waste heat) must be taken, if it's possible,
before the engine thermostatic valve. An inlet and outlet valve must be fitted on
the Distiller Heater for insulation purposes.
It is necessary to install a by-pass valve between the inlet and outlet of this heater
to regulate the hot water flow to the desalinator and, in this way, the production of
the unit. Anyhow, enough hot water must be supply to the unit for correct
operation. In this manual are included some installation diagrams depending on
the engine characteristics or steam proprieties.
Normally the Fresh Water Generator connections to engine jacket cooling water
circuit must be agreed with engine manufacturer.
For pipe dimensions see dimensional drawing enclosed. These pipes never must
be smaller than the heater connection.
When the operation of the fresh water generator is required and the main engine
is out of service or its thermal energy is not enough to reach the fresh water
nominal capacity, other fluids can be used as heat source. By example: Steam,
pressurized water, thermal oil, electrical heater, etc. In this manual are included
some different installations using these alternative methods.
As it was said in the before chapter, the design of this pipe is critical for good
operation of the unit. Never install a square elbow after the diffuser tube. The
good installation of this brine discharge will allow a good performance of the unit.
AQ08-INF-TEC-ING 9
The maximum total backpressure allowed in the brine discharge is 0,3 bar(g). In
case that this backpressure would be higher, please consult with the factory.
The connecting pipes to the unit must be 1/2” or 1” bigger than the
ones installed in the fresh water generator to prevent pressure losses
in the jacket cooling water and sea water circuits.
Standard connections for small range (up to AQ-3/4) are threat (if it’s required the unit
can be delivery with flanges DIN-2576, PN-10)
Standard connections for medium and big range are with flanges DIN-2576, PN-10.
AQ08-INF-TEC-ING 10
SALINOMETER/SWITCH PANEL (SALTEST V)
Each unit is supplied with its salinometer, control and pump starters inside one
electrical board. There are two different sections:
• Salinometric unit
The pumps can be operated from this board. In the door, there are the pump push
buttons. Inside, there is the transformer, the automatic fuse, contactor and
thermal relay for each pump.
SPECIFICATION
Internal connections:
AQ08-INF-TEC-ING 11
CONTROLS:
AQ08-INF-TEC-ING 12
AQ08-INF-TEC-ING 13
AQ08-INF-TEC-ING 14
AQ08-INF-TEC-ING2 15
AQ08-INF-TEC-ING2 16
AQ08-INF-TEC-ING2 17
L
1 1
P1 1 P2 1
1 3 5 1 3 5 E4 E5
E1 E2 1 2 3 2 5
2 2 4 4
M1 C1 13 C1 21 M2 C2 13 C2 21
220V
1 3 5 2 4 6 2 4 6
R1 R2 1 3 R1 R2
95 95
4 96 96
E6 4 6
C1 A2 C2 A2
2 X1 X1 X1 X1 X1
A1 A1
1 2 3 4 5 6 7 8 9 L0 41 L1 L10 61 L2 L20
X2 E1 14 X2 X2 E2 14 X2 X2
SUMINISTRO
POWER
13 13
2
M M N
220V/50HZ 3 3
380V/50HZ
400V/50HZ BOMBA BOMBA
415V/50HZ
AGUA DULCE AGUA SALADA
220V/60HZ DISTILLATE SEA WATER
440V/60HZ PUMP PUMP
1 27.04.93 DISTRIBUCION MANIOBRA BOMBAS A.F.L. A.F.L A.F.L. A.B.F. THIS DRAWING HAS NOT BEEN PUBLISHED AND IS
THE SOLE PROPERTY OF GEFICO ENTERPRISE AND efico Enterprise
IS LENT TO THE BORROWER FOR HIS CONFIDENTIAL
USE ONLY: ANDIN CONSIDERATION OF THE LOANOF
THIS DRAWING, THE BORROWER PROMISES AND
AGREES TO RETURN IT UPON REQUEST AND A.F.L.
AGREES THAT IT SHALL NOT BE REPRODUCED, A.FDEZ
AQ25A-INF-TEC-ING COPIED, LENT OR OTHERWISE DISPOSED OF
DIRECTLY OR INDIRECTLY, NOR USED IN ANY WAY A.LINAR
DETRIMENTALTO THEINTERESTOF THISCOMPANY. A.F.L.
20
L 1
9
3 RAL 4
1
17 22 23 24
2 1 11 10 3
8
RAL 2 1
4 PA
SALINITY 6 5 22 23 24
+ 3 UNIT 9
7b RAL
1 1 A ALARMA REMOTA SIN TENSION
FREE VOLTAGE ALARM
UNIDAD 19
-
4 SALINOMETRICA
2a
5 6 7 8
3
1 2
PA
4
13 14 15 17 17 16 19
1
2
N 2 17
3 4
A B C
13 14 15 17 16 18 19
11
0 1 2 3 0 4 5 6 0 7 8 9 13 14 15 16 17 18 19 22 23 24
A B C
U V W U V W
M III M III
R S T
0 0 0 220V
TIERRA
TIERRA
TIERRA
GROUND
ALIMENTACION
POWER
GROUND
BOMBA DESTILADO
DISTILLATE PUMP
GROUND
BOMBA AGUA SALADA
SEA WATER PUMP
CELULA SALINOMETRICA
SALINOMETRIC CELL
ALARMA LOCAL
LOCAL ALARM
SOLENOID VALVE