APAQ C130
Digital 2-wire transmitter
for Pt100 and Pt1000 with
wireless communication
APAQ C130 is a modern transmitter with high reliability and great performance. External influences such
as ambient temperature, vibration, moisture and EMC interference have minimal influence on the meas-
urement result, thanks to the robust design.
What characterizes APAQ C130 is simplicity. You can easily configure the transmitters wirelessly via NFC
with your smartphone or tablet. There is no need for expensive configuration tools or fixed workstations
for transmitter configuration.
Measurements with Pt100 & Pt1000 sensors Designed for harsh conditions
in 2-,3-, 4-wire connection Rugged design tested for 10 g vibrations.
APAQ C130 accepts inputs from Pt100 & Pt1000 sensors in
2-, 3-, 4-wire connectios acc. to IEC 60751 (α=0.00385) Mounting, wiring and testing
APAQ C130 is designed to fit inside connection heads type
DIN B or larger. The large centre hole, dia. 7 mm / 0.28
Temperature linear output inch, the robust terminals with test connections and the
Fully temperature linear 4-20 mA output.
low height greatly simplify the mounting, wiring and testing
High accuracy procedure.
With an accuracy of ±0,15 K or ±0,15 % of span (the largest
apply) APAQ C130 offers an outstanding performance in its Wireless configuration
class. Configure APAQ C130 wirelessly with your smartphone
without power supply and cables
Compact design for easy installation
The head-mounted variant is only 10.5 mm high and can INOR Connect, easy-to-use app for configuration
easily be installed in all DIN B connection heads. The simple and user friendly app, INOR Connect, is used
for transmitter configuration in seconds. All parameters
Reliable over time are set in the app and then transferred to the transmitter
Minimal drift of ±0.05°C or ±0.05% of span/ year reduces via NFC.
the need for calibration.
INOR Process AB, PO Box 9125, SE-200 39 Malmö, Sweden, Phone: +46-40-31 25 60, Fax: +46-40-31 25 70, E-mail: [email protected]
INOR Transmitter OY, Unikkotie13, FI-01300 Vantaa, Finland, Phone:+358-10-421 7900, Fax: +358-10-421 7901, E-mail: [email protected]
INOR Transmitter GmbH, Am See 24, 47279 Duisburg, Germany, Phone: +49-203-7382 7620, Fax: +49-203-7382 7622, E-mail: [email protected]
KROHNE Temperature Division INOR, 55 Cherry Hill Drive, Beverly, MA 01915, USA, Phone: +1-978-826 6900, Fax: +1 978 535 1720, Email: [email protected]
www.inor.com
Specifications
Input RTD
Pt100 (IEC 60751, α=0.00385) 2-, 3-, 4-wire connection -200... +850°C / -328...+1562°F
Pt1000 (IEC 60751, α=0.00385) 2-, 3-, 4-wire connection -200... +850°C / -328...+1562°F
Sensor current ≤ 0.5 mA
Maximum sensor wire resistance 50 Ω/wire
Monitoring
Sensor break and sensor short circuit indication Upscale (≥21.0 mA) or downscale (≤3.6 mA) action
Adjustments
Zero adjustment Any value within range limits
Minimum span 20 °C / 36 °F
Output
Output signal 4...20 mA, temperature linear
NAMUR compliance Current limitations and failure currents acc. to
NAMUR NE 43
Adjustable filtering level 0.4 to 26 s
Permissible load, see load diagram 818 Ω @ 24 VDC
General data
Isolation Not galvanically isolated
Power supply, polarity protected 6...32 VDC
Environment conditions
Ambient temperature Storage and operation -40...+85°C / -40...+185°F
Humidity 0...98% RH (non-condensing)
Vibrations Acc. to IEC 60068-2-6, test Fc, 10...2000 Hz, 10 g
Rough Handling Acc. to IEC 60068-2-31:2008, test Ec
EMC Standards Directive: 2014/30/EU
Harmonized standards: EN 61326-1, EN 61326-2-3
Immunity performance ESD, Radiated EM-field, Magnetic Fields: Criteria A
Burst, conducted RF: Criteria A
Surge: standard deviation 1% of span
Accuracy and stability
Basic accuracy Max of ±0,15K or ±0,15% of span
Temperature influence Deviation from 20 °C / 68 °F Max. of ±0,015°C / °C or ±0,015 % of span / °C
Max. of ±0,015°F / °F or ±0,008 % of span / °F
Sensor wire influence 2-wire: Compensation for 0 to 100 Ω loop resistance
3-wire: Negligible, with equal wire resistence
4-wire: Negligible
Supply voltage influence Negligible
Long-term stability ±0.05 % of span per year
Housing
Material, Flammability (UL) PC/ABS + PA, V0
Mounting DIN B-head or larger, DIN rail (with mounting kit)
Connection Single/stranded wires, Max. 1.5 mm2, AWG 24…12
Weight 32 g / 0.07 lb
Protection, housing / terminals IP 65 / IP 00
2
Input connections Output load diagram
RLOAD(Ω) =(U-6)/0.022
* RTD Pt100 / Pt1000
2-wire connection
RTD Pt100 / Pt1000
3-wire connection
Supply voltage U (V DC)
RTD Pt100 / Pt1000
4-wire connection
Dimensions
* Short terminals 1 and 2 on the transmitter,
max 50 Ω on each wire
Output connections
mm/inches
IOUT RLOAD
Ordering information
APAQ C130 RTD 70C1300011
Head mounting kit 70ADA00017
DIN-rail Adapter + Screw (10 pcs) 70ADA00027
All information subject to change without notice.
© INOR 03/2020 - 1000646971