A1-A3-2 Storey Incl Fence & Garage
A1-A3-2 Storey Incl Fence & Garage
A1-A3-2 Storey Incl Fence & Garage
SHEET
OFFICE OF THE BUILDING OFFICIAL
NUMBER
SHEET TITLE / CONTENTS
GENERAL NOTES
1. SEPARATE APPROVALS FOR PERMITS FROM GOVERNING AGENCIES MAY BE 8. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ANY
REQUIRED FOR ALL BUIDING AND SITE IMPROVEMENT SYSTEMS, INCLUDING, BUT DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
NOT NECESSARILY LIMITED TO, FIRE PROTECTION SYSTEMS, WHICH MAY REQUIRE
THE SUBMISSION OF ADDITIONAL ENGINEERING CALCULATIONS OR DETAIL
9. SITE SURVEY DRAWING ARE FOR INFORMATION ONLY. CONTRACTOR SHALL
VERIFY AND PROVIDE ALL SITE SURVEY REQUIRED FOR THE WORK OF THIS
ARCHITECTURAL
DRAWINGS FOR APPROVAL. PREPARATION OF SUCH DOCUMENTS AND
PROJECT.
OBTAINING THE PERMIT(S) SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
10. LOT AND BUILDING BOUNDARIES SHALL BE SUPPORTED BY RETAINING WALLS
2. DO NOT SCALE DRAWINGS AND FENCES. CONTRACTOR SHALL VERIFY EXISTING HEIGHTS, ELEVATIONS, District/ City/ Municipality
3. ALL FLOOR ELEVATIONS SHOWN REFERENCED AS FINISHED FLOOR ELEVATIONS AND OTHER SITE CONDITIONS.
REFER TO TOP OF CONCRETE SLAB UNLESS OTHERWISE NOTED. 11. CONTRACTOR SHALL VERIFY ALL DOOR SIZES, SWINGS, LOCATIONS AND
PERSPECTIVE, SITE DEV'T PLAN, VICINITY
4. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING DETAILS WITH JOB CONDITIONS PRIOR TO FABRICATION AND INSTALLATION. A - 1.0 MAP, TECHNICAL DETAILS, GENERAL
WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS
AND SHALL BE INCLUDED AS PART OF CONTRATORS WORK.
12. FINISHES INDICATED IN WALL AND BASE, COLUMNS SHALL APPLY TO ALL WALLS
AND COLUMNS WITHIN THE AREA, UNLESS OTHERWISE NOTED.
NOTES
5. REFER TO CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, PLUMBING, 13. ALL WORKS HEREIN SHALL BE DONE UNDER THE STRICT SUPERVISION OF DULY
ELECTRICAL, FIRE PROTECTION AND OTHER DISCIPLINE DRAWINGS FOR LICENSED AND EXPERIENCED ARCHITECT/ENGINEER.
GROUND FLR PLAN, SECOND FLOOR
ADDITIONAL GENERAL NOTES.
6. ALL INTERIOR PARTITIONS, FURNITURE LAYOUT, AND LANDSCAPE ELEMENTS ARE
14. THE GENERAL CONTRACTOR, SUB-CONTRACTORS INCLUDING SPECIALTY A - 2.0 PLAN, ROOF PLAN, FRONT ELEVATION,
CONTRACTORS SHALL SUBMIT PROPER SHOP DRAWINGS INCLUDING
INDICATIVE ONLY AND MAY CHANGE. CONTRACTOR SHALL VERIFY THE
MATERIALS SAMPLE PRIOR TO INSTALLATIONS FOR ARCHITECT'S APPROVAL. LEFT SIDE ELEVATION, RIGHT SIDE
DISCIPLINE DRAWINGS.
7. ALL DISTANCES, DATA, AND EXISTING STRUCTURES AND UTILITIES ABOVE OR ELEVATION, REAR ELEVATION, FLOOR
BELOW THE GROUND, WITHIN THE LIMITS OF THIS PROJECT SHALL BE CHECKED
BY THE CONTRACTOR. IN CASE OF CONFLICT, THE ARCHITECT SHALL BE
FINISHES
NOTIFIED IMMEDIATELY IN ORDER THAT A CLARIFICATION MAY BE MADE. LAND USE & ZONING
SECTION-A, SECTION-B, GROUND FLR
A - 3.0 RCP, 2ND FLR RCP, DOOR SCHEDULE,
WINDOW SCHEDULE, TOILET 1&2
DETAILS,
STRUCTURAL
1
S4
1°
0.6
17
ST - 1.0
'E
9M
2
GENERAL NOTES
TS
ST - 2.0
18
5°
4
05
'E
4.5
7M
TS
4
5 SCHEDULE OF BEAMS, SCHEDULE OF
LOT 8, PCS-04-025295 COLUMNS AND SCHEDULE OF SLAB
S4
5°
RO
05
'E
AD
3.9
ARCHITECTURAL
LO
0M
T
TS
3,
PC
S-0
S4
4-0
1°
8
21
1.0
17
PLUMBING
18
9
6
'E
4
M
TS
7
TS
0M
TS
.0
12
M
0
.0
'W
12
PL - 1.0
55
S4
GENERAL NOTES
N4
'E
4°
°
55
5°
S4
05
°
'E
05
44
'W
4.8
5M
4.9
6M
TS
TS
5 LOT 7, PCS-04-025295
1
PL - 2.0 1F SANITARY & STORM LAY-OUT
2F SANITARY & STORM LAY-OUT
N4
5°
05
'W
3.1
0M
5
4
SANITARY & VENT ISOMETRIC LAY-OUT CIVIL / STRUCTURAL
1F WATER LINE LAY-OUT
N4
5°
05
'W
3.9
0M
TS
ELECTRICAL
4.8
5M
TS
GENERAL NOTES
2
3 PERSPECTIVE EL - 1.0 SCHEDULE OF LOADS PLUMBING
A01 SINGLE PANEL DIAGRAM
2 LOT PLAN PANEL DETAIL
A01
PROJECT LEGEND OF ELECTRICAL DEVICES
1F POWER LAY-OUT
LOCATION 2.30 1.21 1.35 1.79
2F POWER LAY-OUT
11.25 6.52 1F LIGHTING LAY-OUT
5.00 4.10 2.15 4.86 1.66 2F LIGHTING LAY-OUT
5
5
7
3
SANITARY
8
N45° 05'W 4.85MTS N45° 05'W 3.10MTS N45° 05'W 4.96MTS
TECHNICAL DESCRIPTIONS :
N45° 05'W 3.90MTS 1.09 MTS
S41° 17'E
2.00
2.00
CABANA CABANA CABANA
3.00
6-1 4.85
ELECTRICAL
S45° 05'E
5.00
TIE LINE: N40° 35'E
9.21
MON 11 BIÑAN
ESTATE to Corner Marked "1"
LOT 9, PCS-04-025295
N48° 43'E 12.00MTS
FOR FUTURE DEVELOPMENT
TECHNICAL DESCRIPTIONS : POOL
4.0 mts x 6.0 mts
4.00
POINTS DIRECTION DISTANCE (m.)
Lot 8, Blk 32 MECHANICAL
1-2 S41° 17'E 0.69
2-3 S45° 05'E 4.57
3-4 S45° 05'E 3.10 C
5.00
3.00
6-7 N45° 05'W 4.96
2.00
7-8 S41° 17'E 1.09
ELECTRONICS
TIE LINE:
643.87 m; From MON 11 BIÑAN
N40° 35'E
1 VICINITY MAP S45° 05'E 3.10MTS 2
0.69MTS
1
S45° 05'E 4.85MTS S45° 05'E 3.90MTS
1
4
5
S41° 17'E
6
3
A01
ESTATE to Corner Marked "1"
GEODETIC ENGINEER
C B' A 4 3 2A 1A 1 A B' C 1 1A 2A 3 4
SMOOTH CEMENT
PLASTERED FIRE WALL
IN ELASTOMERIC PAINT
FINISH. APPLY 2 COATS
WATER PROOFING.
PROVIDE 20MM PRE-PAINTED G.I 1"x2" VERTICAL TUBULAR PRE-PAINTED 1"x2" VERTICAL
PRE-PAINTED G.I
GROOVE LINES SHEET ROOF
SHEET ROOF STEEL SUNSHADE G.I SHEET TUBULAR STEEL
FLASHING FLASHING ROOF SUNSHADE
FLASHING
ROOF APEX LINE ROOF APEX LINE
EL + 7.65 M EL + 7.65 M
0.65
0.65
0.65
0.65
1.15
ROOF BEAM LINE ROOF BEAM LINE
EL + 7.00 M EL + 7.00 M
0.50
0.50
0.50
0.50
2F FIN CLNG LINE 2F FIN CLNG LINE
EL + 6.50 M EL + 6.50 M
4.15
4.15
4.04
3.50
D W W W W W
3.00
3.00
3.00
3.00
6.16
W 06 06 03 03 EDILS 04 SLIDE 05
08
EDILS SLIDE
0.90
0.90
8.25
FIXED FIXED
7.95
7.95
7.84
2F FIN.FLR LINE 2F FIN.FLR LINE
EL + 3.50M EL + 3.50M
0.50
0.50
0.50
0.50
0.50
2F FIN. CLNG LINE 2F FIN. CLNG LINE
EL + 3.00 M EL + 3.00 M
1.20
W W
2.10
01 01 W
02
3.50
3.50
3.80
3.80
3.80
3.00
W EDILS FIXED FIXED SLIDE
W EDILS SLIDE
3.30
3.30
D 07 D
08 03 05
SLIDE
W EDILS
D
08 01
2.40
2.10
2.20
0.90
0.90
1F FIN. FLR. LINE 1F FIN. FLR. LINE
0.30
0.30
EL +0.00M EL +0.00M
TOP OF SIDEWALK TOP OF SIDEWALK
EL - 0.30M EL - 0.30M
7 RIGHT SIDE ELEVATION 6 REAR ELEVATION 5 LEFT SIDE ELEVATION 4 FRONT ELEVATION
A02 A02 A02 A02
1 1A 2A 3 4 1 1A 2A 3 4
1 1A 2A 3 4
2.30 1.21 1.35 1.79 2.30 1.21 1.35 1.79
2.30 1.21 1.35 1.79 7.72
11.25 4.86 1.66
0.95 1.20 4.91 1.61
0.80 1.91 0.60 0.40 0.55 1.10 0.95 5.00 4.10 2.15 1.03 2.29 0.79 0.75
7.60
A A
1.00 6.52 A
5
5
2
7
4
3
8
7
05-26-22
N45° 05'W 4.85MTS N45° 05'W 3.10MTS N45° 05'W 4.96MTS
5 6 N45° 05'W 3.90MTS 1.09 MTS
6 7 8
5 8
S41° 17'E
SERVICE
AREA
UTILITY
2.00
2.00
CABANA CABANA CABANA
AREA
2.00
0.60
W W
12 12 12 8 08
11 D
A 03 A
A
0.75
FOR FUTURE DEVELOPMENT D
02
POOL DECK
1.00
KITCHEN TOILET
2.95
3.00
3.00
3.00
BEDROOM &
BATH
3.00
3.00
BALCONY BATH B B
B
D D BAR COUNTER/
06
1.25
02 DINING
5.00
AREA
LANAI
9.20
DN
ROOF LINE ABOVE
7.00
7.00
12.00
LOT 9, PCS-04-025295
N48° 43'E 12.00MTS
2.00
W 05
06 W W
05 02
FOR FUTURE DEVELOPMENT
POOL
10.00
4.05
4.00
4.00
4.00
LANAI TO
LIVING
4.00
4.00
BELOW
0.50
AREA
FAMILY
HALL
W W
1.10
03 01 FOYER
UP
0.40
D
C W 01 W C
C W W W
01 02
03 04 05 PORCH
5.00
FOR FUTURE DEVELOPMENT
1.00
POOL DECK
3.00
3.00
2.15 6.05
6.99
0.69MTS
S45° 05'E 3.10MTS 2
1
S45° 05'E 4.85MTS S45° 05'E 3.90MTS 3
1
4 2
S45° 05'E 4.57MTS
4
5
3 S41° 17'E
6
1
4 3 2 1
1.50 1.64 1.20 0.91 0.60
2.50 2.50
5.00 4.10 2.15 5.85
17.11
0.90
0.90
FIXED FIXED FIXED FIXED FIXED
0.65 0.75 0.75
3.00
3.00
SLIDE EDILS SLIDE
2.10
2.10
2.10
2.10
2.10
1 1A 2A 3 4 A B C D
0.31
QTY 1 SET QTY 3 SETS QTY 1SET QTY 1 SET QTY 1 SET QTY 1 SET ROOF APEX LINE
0.30
EL + 7.65 M
0.65
1.15
ROOF BEAM LINE
EL + 7.00 M
1.75
0.50
7 DOOR SCHEDULE 2F FIN CLNG LINE
EL + 6.50 M
A03
2.95
4.04
3.00
3.00
2.45
2.00
1.50 2.00 1.00
0.60 1.00 1.00 0.60
W W W
0.90
0.90
12 12 12
0.90
0.90
0.90
FIXED FIXED FIXED
1.00
0.90
FIXED FIXED FIXED FIXED
1.05
1.00 0.60
7.84
2F FIN.FLR LINE
2.10
2.10
EL + 3.50M
0.50
0.50
0.50
0.60
0.45
2.28
3.00
3.00
1.00
FIXED
3.00
1.20
1.20
1.20
FIXED SLIDE
1.05
EDILS SLIDE
EL + 3.00 M
1.50
EDILS SLIDE
0.50
0.60
SLIDE EDILS
0.60
FIXED FIXED
2.10
2.10
1.20
FIXED FIXED 0.57 0.57 0.57 0.57
1.60
0.50 0.50 0.60
0.75 0.75
FIXED
1.00
1.04
2.10
0.90
0.90
0.90
0.90
0.60
FIXED
3.50
FIXED
3.80
3.15
3.30
D
2.45
SLIDE EDILS
03
SLIDING WINDOWS WITH FIXED AWNING WINDOW: AWNING WINDOW: SLIDING WINDOWS WITH FIXED ALUMINUM WINDOWS WITH FIXED FIXED WINDOWS: SLIDING WINDOW WITH FIXED AWNING WINDOW : SLIDING WINDOWS WITH FIXED AWNING WINDOWS :
W WINDOW : W 10MM THK GLASS, ON W 10MM THK GLASS, ON W WINDOW : W GLASS: W 10MM THK GLASS, ON W TRANSOM WINDOW : W 10MM THK GLASS ON W WINDOW : W 10MM THK GLASS ON
01 02 03 04 05 06 07 08 ALUMINUM FRAMING 11 12
2.10
10MM THK GLASS ON ALUMINUM FRAMING ALUMINUM FRAMING 10MM THK GLASS ON 10MM THK GLASS, ON ALUMINUM FRAMING 10MM THK GLASS ON 10MM THK GLASS ON ALUMINUM FRAMING
ALUMINUM FRAMING ALUMINUM FRAMING ALUMINUM FRAMING ALUMINUM FRAMING ALUMINUM FRAMING
LOC
1.05
LOC LIVING AREA LOC 1F STAIRCASE LOC HIGH CEILING LOC FAMILY HALL 2F STAIRCASE LOC HIGH CEILING LOC KITCHEN LOC TOILET AND BATH LOC KITCHEN LOC MASTER BEDROOM
QTY CORNER WINDOW : 1 SETS QTY 1 PC QTY 1 PC QTY 1 SET QTY 1 PC QTY 1 PC QTY 1 SET QTY 2 SETS QTY 1 SET QTY 3 SETS
1F FIN. FLR. LINE
EL +0.00M
TOP OF SIDEWALK
EL - 0.30M
05-26-22 5 6 7 2 3
5 4 6 7
8 8
l k j
1.00
1.00
1.51
1.50
k j
1.31
1.31
w w w w k
0.50
j
0.50
l jkl
D D S
02 02
1.85 1.00
3.00
1.00
3.00
1.85
u
S
FLOOR PLAN 3W tu t m
LED STRIP LIGHTING UNDER OVER-HEAD CABINET
g
z o
op
S
v t t n
b'
h h h g
o
y
t mn
SS
FIN.CLNG.LINE
EL+ 2.40M
FIN.CLNG.LINE a' a'b'
EL+ 2.40M
yz
S
m
v n h
vw i i i g
0.50
0.50
3W tu y p
t u t
S S ghi
S
S S
f f
2.45
2.45
3wd
e q d d
s
1.60
1.65
a' a a
b'
q
b
q
s
a a
3wd
abc
a'
def
e q q rs d
A03 A03 S SS S
r r b'
b b
s s s
a'
c c c c c c
4 3 2 1 6 4 5 3 2
1 1