9135 Alarm Codes

The document describes alarm codes and faults that may occur on a Pulsar MX UPS. There are two types of faults: internal faults related to components like the power module, battery, or frame; and environmental faults related to issues like missing modules, overload conditions, or incompatible components. Each fault has a unique code and message displayed on the UPS, and most are stored in an alarm history for service technicians to address.

Uploaded by

gabriel cordero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
226 views4 pages

9135 Alarm Codes

The document describes alarm codes and faults that may occur on a Pulsar MX UPS. There are two types of faults: internal faults related to components like the power module, battery, or frame; and environmental faults related to issues like missing modules, overload conditions, or incompatible components. Each fault has a unique code and message displayed on the UPS, and most are stored in an alarm history for service technicians to address.

Uploaded by

gabriel cordero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

About alarm codes here is how it works on current Pulsar MX:

There are two kinds of fault:


Æ Internal faults
- power module fault (replacement of the power module needed)
- battery fault (replacement of the battery module needed)
- frame fault (replacement of all the UPS needed)
Æ Environment faults

Æ Internal fault :

Stored into Alarm


Title Code Fault display
history
CHARGER FAULT
Internal SERVICE REQUIRED
CHARGER FAULT 500 YES
fault ALARM 500
( ) 3s TO RESET
FAN FAULT
SERVICE REQUIRED
FAN FAULT 007 YES
ALARM 007
( ) 3s TO RESET
UPS TEMPERAT
FAULT
UPS TEMPERAT
004 SERVICE REQUIRED YES
FAULT
ALARM 004
( ) 3s TO RESET
INVERT FUSE
BLOWN
INVERT FUSE BLOWN 701 SERVICE REQUIRED YES
ALARM 701
( ) 3s TO RESET
NORM AC FUSE
BLOWN
NORM AC FUSE
100 SERVICE REQUIRED YES
BLOWN
ALARM 100
( ) 3s TO RESET
RECTIFIER FAULT
SERVICE REQUIRED
RECTIFIER FAULT 305 YES
ALARM 305
( ) 3s TO RESET
DCBUS x TOO xxxx
DC BUS +/- TOO SERVICE REQUIRED
300 YES
HIGH/LOW ALARM 300
( ) 3s TO RESET
INVERTER FAULT
SERVICE REQUIRED
INVERTER FAULT 704 YES
ALARM 704
( ) 3s TO RESET
BATTERY FAULT
SERVICE REQUIRED
BATTERY FAULT 607 YES
ALARM 607
( ) 3s TO RESET
AUTO BYPASS
FAULT
AUTO BYPASS FAULT 207 SERVICE REQUIRED YES
ALARM 207
( ) 3s TO RESET
DC POWER SUP
FAULT
DC POWER SUP
00A SERVICE REQUIRED YES
FAULT
ALARM 00A
( ) 3s TO RESET
INTERNAL COM
INTERNAL COM FAULT
FAULT 005 SERVICE REQUIRED YES
(FRAME FAULT) ALARM 005
( ) 3s TO RESET
INTERNAL COM
INTERNAL COM
FAULT
FAULT
00E SERVICE REQUIRED YES
(POWER MODULE
ALARM 00E
FAULT)
( ) 3s TO RESET
COM FAULT BETW
UPS
COM FAULT BETW
006 SERVICE REQUIRED YES
UPS
ALARM 006
( ) 3s TO RESET
Æ Environment fault :

Stored into Alarm


Title Code Fault display
history
NO POWER MODULE
Environment INSERT MODULE
NO POWER MODULE 703 YES
fault ALARM 703
-------------------------------
NO BATTERY MODULE
NO BATTERY INSERT MODULE
60C YES
MODULE ALARM 60C
-------------------------------
OUTPUT OVERLOAD
REDUCE THE LOAD
OUTPUT OVERLOAD 808 NO
ALARM 808
-------------------------------
INV THERM
OVERLOAD
INV THERM
70A ALARM 70A YES
OVERLOAD
-------------------------------
( ) 3s TO RESET
INVERT LIMITATION
-------------------------------
INVERT LIMITATION 700 YES
ALARM 700
( ) 3s TO RESET
BYPASS AC FREQ
NOK
BYPASS AC FREQ
206 CHECK BYPASS AC NO
NOK
ALARM 206
-------------------------------
FREE RUNNING MODE
CHECK BYPASS AC
FREE RUNNING MODE 709 NO
ALARM 709
-------------------------------
BYPASS AC VOLT NOK
BYPASS AC VOLT CHECK BYPASS AC
209 NO
NOK ALARM 209
-------------------------------
REDUNDANCY LOSS
REDUCE THE LOAD
REDUNDANCY LOSS 00B NO
ALARM 00B
-------------------------------
I/O BAD CONNECTION
CHECK AC WIRING
I/O BAD CONNECTION 00C YES
ALARM 00C
-------------------------------
NO BATTERY
CHECK CONNECTION
NO BATTERY 60D YES
ALARM 60D
-------------------------------
OPERATION LIMITS
B02 : battery
transfer
B03 : bypass ac ALARM OPERATION
nok LIMITS xxx
NO
B04 : UPS SERVICE REQUIRED
overload www.mgeups.com/lcm
B05 : Load level
B06 : Ambient
temp
POWER MODULE
POWER MODULE NOT COMPATIBLE
70C NO
NOT COMPATIBLE ALARM 70C
-------------------------------
UPS1/UPS2
UPS1/UPS2 NOT COMPATIBLE
00F NO
NOT COMPATIBLE ALARM 00F
-------------------------------
SOFT FRAME/POWER
SOFT FRAME/POWER NOT COMPATIBLE
010 NO
NOT COMPATIBLE ALARM 010
-------------------------------

Here is an example of PW fault display: