15.

0mm

Metric
'G' Approx~ ~(Compressed Length)
Cable Gland Type
Entry $BCMF.$. 0%.JMJNFUFST
501/421
Entry Thread
(MBOE1/%.4 ATEX

Ø 'B'
Flameproof and Increased Safety

CABLE GLAND SELECTION TABLE 15.0mm 'G' Approx (Compressed Length)

Cable Acceptance Details

Entry Thread
Entry Thread Hexagon

Ø 'B'
Outer Sheath 'B'
Size Size Dimensions
Standard Alternative 'G'
Ref. NPT* Seal Seal (S)
Metric Std./
Across Across 2K Size Cable Gland Design
Option Min. Max. Min. Max. Flats Corners
2K M16 - 3.0 8.0 - - 27 19.0 21.2

501/421 Cable Gland


Application
Os M20 2 ½" 3.0 8.0 - - 32.8 24.0 27.7
Outdoor or Indoor use.
O M202 ½" 7.5 11.9 - - 32.8 24.0 27.7 For use with non-armoured elastomer
A M20 ¾"/½" 11.0 14.3 8.5 13.4 32.8 30.0 34.6 and plastic insulated cables.
B M25 1"/¾" 13.0 20.2 9.5 15.4 33.8 36.0 41.6 See technical section of the catalogue
C M32 1¼"/1" 19.0 26.5 15.5 21.2 35.2 46.0 53.1 for installation rules and regulations.
C2 M40 1½"/1¼" 25.0 32.5 22.0 28.0 36.5 55.0 63.5
D M50 2"/1½" 31.5 /42.31
44.4/
44.4/42.3 27.5 34.8 47.9 65.0 75.1 Features
E M63 2½"/2" 42.5 56.3/54.31 39.0 46.5 46.2 80.0 92.4 Provides a cable retention seal onto the
F M75 3"/2½" 54.5 68.2/65.31 48.5 58.3 48 95.0 109.6 cables outer sheath.
G M80 3½" 67.0 73.0 - - 41 106.4 123.0 When used in increased safety
- - applications, this cable gland may be used
H M90 3½" 67.0 77.6 41 115.0 132.8
with braided cable where the braid and
J M100 4" 75.0 91.6 - - 41 127.0 146.7 the cables outer sheath pass into the
1 Smaller value is applicable when selecting reduced NPT entry option. enclosure.
2 Sizes
Os and O are available with an M16 thread size. For O size with M16 The braid must be suitably terminated
thread, the maximum cable outer sheath diameter is 10.9mm. inside the enclosure.

General Information Technical Data


Flameproof EExd and Increased
All Metric entry threads are 1.5mm pitch medium fit.
Safety EExe. II 2 GD
All dimensions in millimetres (except* where dimensions are in inches).
Baseefa Certificate No.
Assembly instruction data sheet No. A.I. 307. For sizes Os to J.
BAS 01 ATEX 2070X. For Os - F.
Baseefa Certificate No.
BAS 01 ATEX 2294X. For G - J.
Accessories including locknuts, sealing washers, serrated washers, earth tags, Suitable for use in Zone 1, Zone 2,
shrouds, adaptors and reducers available. See pages 44 - 48. Zone 21 and Zone 22.
Suitable for use in Gas Groups
IIA, IIB and IIC.
Construction and test standards
Materials & Finishes EN 50014, EN 50018, EN 50019
The 501/421cable gland is manufactured as standard in brass, stainless steel and EN 50281-1-1.
and aluminium. IEC 60079-0, IEC 60079-1 and
NPT entries, nickel plated as standard. Full nickel plating available. IEC 60079-7.
IP66, IP67 and IP68 (30 metres for 7 days)
ingress protection to IEC 60529,
EN 60529 and NEMA 4X.
Cable Gland Ordering Examples DTS01 deluge protection certified by ITS.
Cable Gland Type/Size/Thread Operating temperature range
-60°C to +100°C as standard.
e.g. 501/421/C/M32 Alternative Certification Options Available.
501/421/C/1¼" NPT Exd IIC/Exe II.
501/421/'/M50/S BR-Exd IIC/Exe II.
Cable Gland with Alternative Seal (S)
GOST R-Exd IICU/Exe IIU.
e.g. 501/421/C/M32/S AUS-Exd IIC/Exe II.
501/421/C/1¼" NPT/S