Saso2663: 2021
Saso2663: 2021
Saso2663: 2021
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Introducing the new requirements for SASO 2663:2021 standard -
Disclaimer
Disclaimer
• This presentation is intended to ensure that all relevant bodies are aware of the issuance of
SASO 2663:2021 standard. This document and all presented information shall not be
considered as the official reference, where the official standard can be found in WASIF portal
at https://wasif.saso.gov.sa/
Overview: Similarity between the requirements for SASO 2663:2021
and SASO 2663:2018 standards
Standard • This Minimum Energy Performance Requirements (MEPS) and the Criteria for acceptability are
Clauses the same and have not been changed, as follows:
4) Minimum MEPS are based on the rated cooling capacity for the rated EER at rating conditions (T1) and
Energy (T3), according to Table 2, below.
Performance
Standard Table 2 – MINIMUM REQUIRED EER (MEPS) APPLICABLE
(MEPS) Rated Cooling Capacity (CC) categories EER Values (Btu/h)/W
Air conditioner appliance type
at test condition (T1) in (Btu/h) (or W) T1 T3
- 4.1) General Single package of Window type – category A CC ≤ 24,000 (7,050W) 9.80 7.00
24,000 (7,050W) < CC
Single package of Window type – category B 9.00 6.20
≤ 65,000 (19,050 W)
Split type ducted and non-ducted using air-
cooled condensers, heat pumps using air cooled CC ≤ 65,000 (19,050 W) 11.80 8.30
condensers
5. CRITERIA FOR • Tested cooling capacity at all specified points………….……………. ≥ 0.95 x rated cooling capacity at all specified points
ACCEPTABILITY • Tested power at all specified points………………..…………………..… ≤ 1.05 x rated power at all specified points
OF PRODUCTS AT • Tested EER at full load operation at (T1 and T3)………………..…… ≥ MEPS and ≥ 0.95 x rated EER at full load operation (T1 and T3)
• Tested COP………………………..………………………………..…………………. ≥ 0.95 x rated COP
REGISTRATION • Rated COP (Electrical Resistance)…..………………………………………. ≤ 1.0 (W/W)
• Tested voltage…………………...………………………………………………..… (refer to the standard mentioned in Clause 2)
• Test Frequency …………………...…………………………….………………..… 60 Hz ±2%
Overview of SASO 2663:2021 standard (1/7)
SASO 2663:2021 AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW-CAPACITY
WINDOW AND SINGLE-SPLIT TYPES
Standard 5) Criteria for A test report from an accredited laboratory or a laboratory approved by SASO shall be
Clauses acceptability presented for registration. This test report shall include the mandatory test results as shown
of products at
below in Table 4 for test characteristics at T1 and T3.
registration
Table 4 – Temperature and Humidity Conditions
- 5.3) Product
using test Two- Multi-
Test Characteristics Fixed Variable Default Values
report to stage stage
Standard Cooling Full capacity ∅𝑓𝑢𝑙 (46) (W) or (Btu/h)
justify the
performance
Capacity
Full power input 𝑃𝑓𝑢𝑙 (46) (W) ▪ ▪ ▪ ▪ —
Indoor: Half capacity ∅ℎ𝑎𝑓 (46) (W) or (Btu/h) 0.859 x ∅ℎ𝑎𝑓 (35)
› 5.3.1) DB 29°C WB 19°C — — D D
Half power input 𝑃ℎ𝑎𝑓 (46) (W) 1.25 x 𝑃ℎ𝑎𝑓 (35)
General Minimum capacity ∅𝑚𝑖𝑛 (46) (W) or (Btu/h) 0.859 x ∅𝑚𝑖𝑛 (35)
Outdoor: — D D D
DB 46°C WB 24°C Minimum power input 𝑃𝑚𝑖𝑛 (46) (W) 1.25 x 𝑃𝑚𝑖𝑛 (35)
Standard 5) Criteria for A test report from an accredited laboratory or a laboratory approved by SASO shall be
Clauses acceptability presented for registration. This test report shall include the mandatory test results as shown
of products at
below in Table 4 for test characteristics at T1 and T3.
registration
Table 4 – Temperature and Humidity Conditions
- 5.3) Product
using test Two- Multi-
Test Characteristics Fixed Variable Default Values
report to stage stage
Low Temperature Full capacity ∅𝑓𝑢𝑙 (29) (W) or (Btu/h) 1.077 x ∅𝑓𝑢𝑙 (35)
justify the D D D
Cooling Capacity —
performance Full power input 𝑃𝑓𝑢𝑙 (29) (W) 0.914 x 𝑃𝑓𝑢𝑙 (35)
Indoor: Half capacity ∅ℎ𝑎𝑓 (29) (W) or (Btu/h) 1.077 x ∅ℎ𝑎𝑓 (35)
› 5.3.1) — — D D
DB 27C WB 19°C Half power input 𝑃ℎ𝑎𝑓 (29) (W) 0.914 x 𝑃ℎ𝑎𝑓 (35)
General Minimum capacity ∅𝑚𝑖𝑛 (29) (W) or (Btu/h) 1.077 x ∅𝑚𝑖𝑛 (35)
Outdoor: — D D D
DB 29°C WB 24°C Minimum power input 𝑃𝑚𝑖𝑛 (29) (W) 0.914 x 𝑃𝑚𝑖𝑛 (35)
Degradation Coefficient
Low Humidity and
Cyclic Cooling Test Full Capacity O — — —
Indoor: Degradation
DB 27°C WB 16°C or Half Capacity — — O — 0.27
Coefficient (𝐶𝐷 )
lower
Outdoor: Minimum Capacity — O O —
DB 35°C WB -
Standard 8) Energy The specified Saudi weather data, presented in table 5, shall be applied to the SASO ISO
Clauses rating 16358-1:2013, Clause 6 (Calculations) and the corresponding changes mentioned in ISO
classification
16358-1:2013/AMD 1:2019 and incorporated into its calculation tool, to find the SEER rating
- 8.2) Saudi and its relevant measurements, such as the Cooling Seasonal Energy Consumption (CSEC).
Arabia’s • Saudi Arabia’s Specific weather bin shall be incorporated into the SLS system.
Specific
Weather Bin. Table 5 – SAUDI ARABIA’S SPECIFIC WEATHER BIN
Outdoor temperature (°C) bin hours (𝐡) Outdoor temperature (°C) bin hours (𝐡)
21 267 34 456
22 279 35 408
23 281 36 395
24 314 37 360
25 309 38 357
26 341 39 335
27 357 40 325
28 366 41 290
29 411 42 240
30 435 43 200
31 464 44 130
32 501 45 78
33 492 46 24
Total: 8415 (h)
Overview of SASO 2663:2021 standard (5/7)
SASO 2663:2021 AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW-CAPACITY
WINDOW AND SINGLE-SPLIT TYPES
Standard 8.3) In order to calculate the Seasonal Energy Efficiency Ratio (SEER) value for products covered
Clauses Calculation within the scope of this standard, the calculation tool shall be applied from ISO 16358-
tool to 1:2013/AMD 1:2019 and based on SASO ISO 16358-1:2013, Clause 6 (Calculations) and the
calculate
corresponding changes mentioned in ISO 16358-1:2013/Amd 1:2019, with the incorporation of
SEER.
Saudi Arabia’s specific weather data under Clause 8.2 within this standard.
• Calculation tool shall be incorporated into the SLS system.
8.4) The Seasonal Energy Efficiency Ratio classification is based on the SEER value, which is calculated
Determination based on the results of the rated values for the cooling capacity and power input at the specified
of the energy testing points mentioned in Table 4, and determined in accordance with the following table.
efficiency class
Table 6 – SEASONAL ENERGY EFFICIENCY (SEER) Classification
Bar color Energy class SEER limits (Rated value) (Btu/W.h)
Dark green أ A SEER ≥ 18.0
Green ب B 18.0> SEER ≥ 15.0
Light green ج C 15.0> SEER ≥ 12.5
Yellow د D 12.5> SEER ≥ 10.0
Orange هـ E 10.0> SEER ≥ 9.0
Red و F 9.0> SEER ≥ 8.0
Dark Red ز G 8.0> SEER
Overview of SASO 2663:2021 standard (6/7)
SASO 2663:2021 AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW-CAPACITY
WINDOW AND SINGLE-SPLIT TYPES
Standard 7.4) The following documents shall be submitted, as a declaration, through the registration system
Clauses Additional electronically via SASO website:
Submittals • Rated cooling capacity and rated cooling power at full load, half load and minimum load operations, for
all testing points mentioned in Table 4 (Including the Degradation Coefficient (CD) test report, if any), as
applicable.
• AC settings for full load, half load and minimum load operation, as applicable
• Specify the compressor stages as per clause 3.2 (Fixed, Two (2)-stage, Multi-stage or Variable capacity)
Overview of draft Seasonal Energy Efficiency Ratio (SEER) standard
(7/7)
SASO 2663:2021 AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW-CAPACITY
WINDOW AND SINGLE-SPLIT TYPES
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Enforcement timeline
Today
• Adhere to the additional requirements
for existing applications
2021 2022
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Recap of the additional submittals
SASO 2663:2021 AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW-CAPACITY
WINDOW AND SINGLE-SPLIT TYPES
Standard 7.4) The following documents shall be submitted, as a declaration, through the registration system
Clauses Additional electronically via SASO website:
Submittals • Rated cooling capacity and rated cooling power at full load, half load and minimum load operations, for
all testing points mentioned in Table 4 (Including the Degradation Coefficient (CD) test report, if any), as
applicable.
• AC settings for full load, half load and minimum load operation, as applicable
• Specify the compressor stages as per clause 3.2 (Fixed, Two (2)-stage, Multi-stage or Variable capacity)
In order to issue a new SEER label, the following is required
Fixed capacity :
• Test report at full load at (T1/ 35 °C) , (T3/ 46 °C).
• Degradation Coefficient (𝐶𝐷 ) test report is optional if the applicant wants to change the set default value of 0.27.
Two-stage:
• Test report at full load at (T1/ 35 °C) , (T3/ 46 °C).
New • Test report at minimum load at (T1/35 °C)
application • Degradation Coefficient (𝐶𝐷 ) test report is optional if the applicant wants to change the set default value of 0.27.
Two-stage:
• Test report at minimum load at (T1/35 °C), otherwise the system will treat the model as fixed capacity .
Upgrade • Degradation Coefficient (𝐶𝐷 ) test report is optional if the applicant wants to change the set default value of 0.27.
Renew application requirements are the same as upgrade application requirement (Previously presented).
Replace an existing EER with a SEER label, the following is
required
On 1st April 2022 ,all applicants who do not upgrade their products to issue the SEER label, the following shall take
place:
• The SEER label will be generated automatically.
Replacement o Two – stages, multi-stages and variable speed compressors will be treated as fixed speed (Resulting in a
lower SEER value and thus, lower model classification).
➢ Models treated as (fixed-speed) can’t be registered as a new application to issue the SEER label
with the same model number.
o Fixed speed will not be allowed to change the default degradation coefficient of 0.27.
AGENDA
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Requirements for Updating the Scope of Registration
To keep your registration valid in this scope; you must achieve the following requirements:
Requirements 1) Update the registration form with the new standard and testing method standards.
for Updating
the Scope of 2) An accreditation from the Saudi Accreditation Center (SAC) or any accreditation body full member
Registration of ILAC in the scope of test method standards mentioned in SASO 2663:2021 standard.
LABs Registration Procedures
Study the
Notes? registration
application
certificate & scope
[email protected]
AGENDA
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Saber Improvements
Adding notification center for users Adding and improving reports feature
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Key questions and takeaways
Key Questions 1. How were the enforcement dates chosen? did SASO considered a sufficient grace period?
2. What should the applicant expect/consider during this time until November 2021 (Start of a new registration)?
3. Following April 1st, 2022, Why EER applications are processed/treated as a fixed-speed type?
4. Why were the Model-numbers - which have treated as (fixed-speed) - will not be allowed to carry-out with new
registrations/applications with same model-numbers?
5. For fixed speed type, do applicants require to submit additional test report? Even if CD value did not change?
Takeaways • Apply for SEER label and upgrade your EER application starting November 2021 (All models)
• Do not exceed April 1st with no action, as this may affect your long-term registration strategy (classification of your
registered model-numbers, downrating your Energy Efficiency level...etc)
• On 1st April, label replacement portal will be available for the market/salespoints
• Following the enforcement dates, old labels in production lines and Markets will be subjected to the relevant
entities violations and related procedures will be applied
AGENDA
Enforcement timeline
Registration requirements
SABER improvements
Q/A
Panelists
Eng. Abdulmajeed
Alabdulkarim
Testing, Inspection and Certification
Department Manager
SEEC