Ahmedabad Mumbai: 255P12 255P13 255P14 CH: 255514 CH: 255554 CH: 255595

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

12 11 10 9 8 7 6 5 4 3 2 1

This drawing is the property of LARSEN & TOUBRO LTD and must not be passed on to any person or body not
MUMBAI AHMEDABAD authorised by us to receive it nor be copied or otherwise made use either in full or in part by such person or body
without our prior permission in writing.

NOTES:
255P12 CH : 255514 255P13 CH : 255554 255P14 CH : 255595 1. FOR SPAN ARRANGEMENT REFER DRAWING NO. : O20361-C-VIA-03-GA-42236.
2. WATER STOPPER CONCRETE DRAWING :
40000 41000
O20361-C-VIA-00-NU-42623 & 42626.
255GR12 (SBS) 255GR13 (SBS)
H O20361-C-VIA-00-NR-42624 TO 42625 & H
CL OHE MAST FDN. CL OHE MAST FDN. O20361-C-VIA-00-NR-42627 TO 42630, 42749
15375 24625 13375 27625 13375 3. NOISE BARRIER (TYPE - A & B) :
50 50 50 50 50 50 O20361-C-VIA-00-NU-42631,42859,42862 & 42865
9950 9950 10000 10000 9950 8180 8180 8180 8180 8180 8180 O20361-C-VIA-00-NR-42632,42633,42860,42861,42863,42864,42866 & 42867
O20361-C-VIA-00-NR-42641.
4. ADDITIONAL PART OF NOISE BARRIER : O20361-C-VIA-00-NU-42640.
8062 EJ FOR TRACK BED (TYP) 5. METAL FENCE FOR EACH OHE MAST FOUNDATION : O20361-C-VIA-00-NU-42634 TO 42637,42868 TO 42871
9975 9975 9975 9975 9975 8180 8180 8180 8180 8180 8180 6. METAL FENCE AT EXPANSION JOINT GAP :

2420
O20361-C-VIA-00-NU-42642 & 42643.
CL OF DN TRACK 7. METAL FENCE FOR COMBINED EJ & OHE MAST :

WIDE DECK
O20361-C-VIA-00-NU-42750 & 42751.
CL OF ALIGNMENT

11900
CL OF EVACUATION WATER STOPPER (TYP)

2080
LEVEL PEG 8. EVACUATION BARRIER :
BARRIER TRACK BED DRAINAGE SPOUT (TYP) (REF. NOTE NO. : 16)
O20361-C-VIA-00-NU-42740 & 42741.
CL OF UP TRACK 9. CABLE PULL PIT AND CONDUIT FOR INSTALLATION OF EMERGENCY STOP BUTTON AT LIGHT SECTION

2420
(TYP)
800 (SESB) :

800
EVACUATION BARRIER
(TYP) O20361-C-VIA-00-NU-42742, (BD-JIC-E1-DRW-ALL-GNL-T06-10027-000)
O20361-C-VIA-00-NR-42743 &
O20361-C-VIA-00-NR-42744.
G 9a. EQUIPMENT INSTALLATION WIDENING AND CABLE CROSSING PIPE CONDUIT G
METAL FENCE (TYPE - A) EARTHING CABLE (TYP) METAL FENCE (TYPE - A) (FOR LCX RELAY)
OHE MAST FDN. EJ FOR ADJUSTING CONCRETE (TYP) FOR OHE MAST (TYP.) NOISE BARRIER (TYP) OHE MAST FDN.
FOR EJ (TYP.) (REF. NOTE NO. : 13) O20361-C-VIA-00-NU-42716. (BD-JIC-E1-DRW-ALL-GNL-T06-10003-000)
875 875 875 875 PRECAST DUCT (TYP) 875
9b. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
B1-1 B2-1 B3 A1 A1 B3 B2-1 B1-1 B2-2 B1-3 C2 B1-3 B1-2 B1-2 C1 B1-2 B2-2 B1-1 B2-1 B3 A1 A1 B'3 B2 B1-1 B'1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-1 B1-1 B2 B'3 A1 A1 B'3 B2 B1-1 B'1-3 O20361-C-VIA-00-NU-42753. (BD-JIC-E1-DRW-ALL-GNL-T06-10001-000)
2350 2600 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2600 2350 2350 2600 2500 2500 2500 9c. CONDUIT FOR INSTALLATION OF EMERGENCY STOP BUTTON AT LIGHT SECTION (SESB) :
2500 2500 2100 2350 2350 2100 2500 2500 2500 2500 1750 2500 2500 2500 1750 2500 2500 2500 2500 2100 2350
O20361-C-VIA-00-NU-42756. (BD-JIC-E1-DRW-ALL-GNL-T06-10028-000)
562 562 562 537 537 9d. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
1x900 NB
12x1000 NB 1426 19x1000 NB 10x1000 NB 1440 24x1000 NB 10x1000 NB O20361-C-VIA-00-NU-42757. (BD-JIC-E1-DRW-ALL-GNL-T06-10012-000)
1x750 NB 9e. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
3x750 NB 3x700 NB 3x700 NB 3x750 NB 573
3x700 NB 1x700 NB 3x700 NB O20361-C-VIA-00-NU-42715. (BD-JIC-E1-DRW-ALL-GNL-T06-10002-000)
9f. TRANSVERSE CONDUIT FOR TELEPHONE LINE AT SMD/RAMP LOCATION.
PLAN AT DECK SLAB LEVEL O20361-C-VIA-00-NU-42745. (BD-JIC-E1-DRW-ALL-GNL-T06-10028-000)
(SCALE 1:200) 10. DRAINAGE PLAN FOR BOX GIRDER :
O20361-C-VIA-00-NU-42611 TO 42614.
11. OPENING IN DECK SLAB (TYPE 1 TO 3) :
O20361-C-VIA-00-NU-42648 TO 42650. (SD-JIC-C01-DRW-ALL-VDT-B99-10404-004,10405-004,10406-002)
O20361-C-VIA-00-NR-42654 TO 42657.
F DECK SLAB OPENING TYPE 1 & 3 SHALL BE PROVIDED ON BOTH GIRDERS AT EJ F
LOCATION.
12. ANCHOR FOUNDATION :
O20361-C-VIA-00-NU-42659. (SD-JIC-C01-DRW-ALL-VDT-B99-10502-008)
255P14 CH : 255595 255P15 CH : 255636
O20361-C-VIA-00-NU-42663. (SD-JIC-C01-DRW-ALL-VDT-B99-10506-006)
41000
O20361-C-VIA-00-NR-42661. (SD-JIC-C01-DRW-ALL-VDT-B99-10504-008)
255GR14 (SBS)
O20361-C-VIA-00-NR-42665 (SD-JIC-C01-DRW-ALL-VDT-B99-10508-006)
CL OHE MAST FDN. O20361-C-VIA-00-NR-42666 (SD-JIC-C01-DRW-ALL-VDT-B99-10509-004)
13375 27625 13375 13. EARTHING ARRANGEMENT FOR VIADUCT INTERMEDIATE AND CENTER POLE - BOX GIRDER
50 50 50 50 O20361-E-VIA-00-GA-59511 (SD-JIC-C01-DRW-ALL-VDT-B99-10602-008)
8180 8180 8180 8180 8180 8180 8180 13a. EARTHING ARRANGEMENT FOR VIADUCT END POLE - BOX GIRDER
O20361-E-VIA-00-GA-59512 (SD-JIC-C01-DRW-ALL-VDT-B99-10602-008)
13b. EARTHING ARRANGEMENT FOR MISCELLANEOUS STRUCTURES ON VIADUCT
EJ FOR TRACK BED (TYP) 14423 O20361-E-VIA-00-GA-59513
8180 8180 8180 8180 8180 8180 8180 14. PRECAST DUCTS :
O20361-C-VIA-00-NU-42667 TO 42669.
CL OF DN TRACK O20361-C-VIA-00-NU-42672 & 42673.
O20361-C-VIA-00-NU-42676 TO 42679.
E CL OF EVACUATION CL OF ALIGNMENT E
O20361-C-VIA-00-NR-42670 & 42671.
TRACK BED BARRIER
O20361-C-VIA-00-NR-42674 & 42675.
EARTHING CABLE (TYP) CL OF UP TRACK O20361-C-VIA-00-NR-42680 & 42681.
ADDITIONAL CONCRETE
O20361-C-VIA-00-NR-42683 TO 42688.
COVER (TYP) EVACUATION BARRIER O20361-C-VIA-00-NU-42841 & 42842.
O20361-C-VIA-00-NU-42845 & 42846.
O20361-C-VIA-00-NU-42848 & 42849.
O20361-C-VIA-00-NR-42843 & 42844.
O20361-C-VIA-00-NR-42847.
OHE MAST FDN. EJ FOR ADJUSTING CONCRETE (TYP) NOISE BARRIER (TYP) OHE MAST FDN. O20361-C-VIA-00-NR-42850 TO 42856.
875 875
15. PANEL SIZE FOR ADJUSTING CONCRETE FOR ELECTRICAL CABLE DUCT ARE MARKED IN THIS DRAWING.
B1-1 B2 B'3 A1 A1 B'3 B2 B1-1 B'1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-1 B1-1 B2 B'3 A1 A1 B'3 B2 B1-1 FOR DOWEL , ADDITIONAL REINFORCEMENT IN DECK SLAB AND OTHER DETAILS REFER DRAWING NO. :
2500 2500 2600 2350 2350 2600 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2600 2350 2350 2600 2500 2500 O20361-C-VIA-00-NR-42692 TO 42695, 42747,42748,42872,42836 & 42837
16. DETAILS OF LEVEL PEGS :
537 537 O20361-C-VIA-00-MS-61305.
1x900 NB 1x900 NB
17. PANEL SIZE FOR TRACK BED ARE MARKED IN THIS DRAWING. FOR DOWEL AND OTHER DETAILS REFER
10x1000 NB 1440 24x1000 NB 10x1000 NB
1x750 NB 1x750 NB DRAWING NO. :
D 573 573 D
1x700 NB 3x700 NB 1x700 NB 3x700 NB O20361-C-VIA-00-NR-42732 & 42733, O20361-C-VIA-00-NR-42737 & 42738.
PLAN AT DECK SLAB LEVEL 18. FOR INSPECTION LADDER REFER DRAWING NO. :
(SCALE 1:200) O20361-C-VIA-00-NU-42699.
19. TRANSVERSE CONDUIT FOR BRANCH LIGHTING AND MAINTENANCE OUTLET :O20361-C-VIA-00-NU-42746
20. OHE FOUNDATION DETAIL REFER RESPECTIVE GIRDER DRAWING.
21. RAILING, ACCESS LADDER, LANDING AND DOOR DETAILS FOR MAINTENANCE GALLERY
O20361-C-VIA-00-NU-42638,42639 & 42714

ABBREVIATIONS
NB - NOISE BARRIER (TYPE - A / B)
EQ - EQUAL
UNO - UNLESS NOTED OTHERWISE
C C
* - NOISE BARRIER AT NARROW LOCATION (TYPE-B).

GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. DIMENSIONS SHALL NOT BE SCALED.
3. LOCATION OF OHE MAST, ANCHOR LOCATIONS AND OPENING SHOWN ABOVE ARE AS TECHNICAL DESIGN
PER EMPLOYER LETTER NO : TCAP/MAHSR/PMC/C4/2022/DN/0760 DATED 15.04.2022
THE CONTRACTOR SHALL ENSURE ALL THE INTERFACE REQUIREMENTS OWNER:

W
AND TCAP/MAHSR/PMC/C4/2022/IFC/1186 DATED 02/07/2022.
KEY PLAN:
4. LOCATION OF S&T SPACE OPENING AND CONDUIT SHOWN ABOVE ARE AS PER DURING ALL THE STAGES OF EXECUTION

N
m

S
EMPLOYER LETTER NO. : NATIONAL HIGH SPEED RAIL

H
K
CH:264.580Km
07. SURAT

ARUC
3.110
TART
TCAP/MAHSR/PMC/C4/2022/INT/0770 DATED 16.04.2022.

0Km

E
06. BILIMORA
B

CH:218.533Km
CH:1 5. VAPI
B CORPORATION LTD.

0Km

CH:393.700Km
C-4 END
5. DRAWINGS GIVEN WITHIN PARENTHESIS ARE CONTRACT DRAWING NUMBERS.

56.60

08. BH
CH:32
C-4 S
2nd FLOOR, ASIA BHAWAN, ROAD NO-205

67.94
6. ANCHOR FOUNDATION AND METAL FENCE (OHE & EJ) SHALL BE OF TYPE-A UNLESS

0
NOTED OTHERWISE. SEC-09, DWARKA, New Delhi -110077

CH:1
7. ADDITIONAL HEIGHT OF NOISE BARRIER, ANCHOR FOUNDATION TYPE-B, METAL FENCE

Km

CH:333.276Km
Km

CH:333.606Km
TYPE-B (OHE & EJ) SHALL BE PROVIDED FOR RESIDENTIAL / URBAN AREAS

10 m

.027
SEC-03

0K
Km

.287
SPECIFICALLY MARKED IN THE DRAWING AND APPOVED BY THE ENGINEER.

77

297
CH 241.
8. WHEREVER S&T EQUIPMENT ARE COMBINED WITH OHE DETOURING, ITS LENGTH

CH:210.273Km

297
CH:210.483Km

5
DWG.NO:

1 .

CH:
SHALL BE AS PER DECK FURNISHING DRAWING. HOWEVER, ITS SERVICE

:24
:

CH:
CH
REQUIREMENTS SUCH AS CONDUITS, PEDESTAL, SPACE ETC, SHALL BE AS PER TD-NHS-LNT-C4-B06-VDT-B99-010135-001 SEC-01 SEC-02 SEC-04 SEC-05
REFERENCE DETAIL DRAWINGS GIVEN IN THE NOTES.

CONTRACTOR: DESIGNER: PROJECT TITLE:


REVISIONS QUALITY ASSURANCE
L&T Construction MUMBAI - AHMEDABAD HIGH SPEED RAIL PROJECT
The responsibility of control, check and verification of accuracy, correctness,
LARSEN & TOUBRO LTD Package No. MAHSR - C - 4 (Km.156.600 - Km.393.700)
completeness, integration, interfacing with other disciplines and full compliance of Heavy Civil Infrastructure,EDRC
contract provisions in respect of design analysis and drawings rests with the DWG TITLE:
A contractor. PROJECT TITLE: SECTION - 03 (Km.241.770 - Km.297.027) A
Design and Construction of Civil and Building Works including Testing and Commissioning
NAME SIGN DATE on Design Build Lump Sum Price Basis for Double Line High Speed Railway involving DECK FURNISHING LAYOUT
DRAWN BY ANIL PADAVAL 25.04.2022
Viaducts, Bridges, Maintenance Depots, Tunnel, Stations (Vapi, Bilimora, Surat and PIER FROM 255P12 TO 255P15
Bharuch), and Surat Depot between Zaroli Village at Maharashtra-Gujarat Border (MAHSR REV:
B 06.09.2022 REVISED IN LINE WITH SRR 12797 COMMENTS BJ SDD SSR KGN DESIGNED BY SUMEET DIVATAGI 25.04.2022 Km. 156.600) and Vadodara (MAHSR Km. 393.700), excluding Works for 04 No. PSC
Bridges and 07 No. Steel Truss Bridges, in the State of Gujarat and the Union Territory of
DWG No: O20361-C-VIA- 03-GA-44249 B
A 25.04.2022 FOR APPROVAL AJP SDD SSR KGN CHECKED BY SAMSON 25.04.2022 SCALE: SIZE:
Dadra and Nagar Haveli for the Project for Construction of Mumbai - Ahmedabad High
CHECKED BY REVIEWED BY APPROVED BY CHECKED BY REVIEWED BY APPROVED BY PRELIMINARY INFORMATION APPROVAL CONSTRUCTION AS SHOWN A1
REV DATE DESCRIPTION DRAWN DSGN CHKD APPD APPROVED BY GANESH K 25.04.2022 Speed Rail
12 11 10 9 8 7 6 5 4 3 2 1
12 11 10 9 8 7 6 5 4 3 2 1
This drawing is the property of LARSEN & TOUBRO LTD and must not be passed on to any person or body not
MUMBAI AHMEDABAD authorised by us to receive it nor be copied or otherwise made use either in full or in part by such person or body
without our prior permission in writing.

255P15 CH : 255636 255P16 CH : 255677 255P17 CH : 255719 NOTES:


41000 42000 1. FOR SPAN ARRANGEMENT REFER DRAWING NO. : O20361-C-VIA-03-GA-42237.
255GR15 (SBS) 255GR16 (SBS) 2. WATER STOPPER CONCRETE DRAWING :
1x750 NB 2x900 NB 550 O20361-C-VIA-00-NU-42623 & 42626.
CL OHE MAST FDN. 725 C OHE MAST FDN.
L
H
13375 27625
9x1000 NB 6x900 NB 7x1000 NB
1x1000 NB
* 2x700 NB
15375
O20361-C-VIA-00-NR-42624 TO 42625 &
O20361-C-VIA-00-NR-42627 TO 42630, 42749
H
50 50 50 50 14375 27625 50 50
3. NOISE BARRIER (TYPE - A & B) :
8180 8180 8180 8180 8180 8180 8380 9762 10000 10000 3761 8200

420
O20361-C-VIA-00-NU-42631,42859,42862 & 42865

440
O20361-C-VIA-00-NR-42632,42633,42860,42861,42863,42864,42866 & 42867

560
O20361-C-VIA-00-NR-42641.
14423 1790 1790 11000
EJ FOR TRACK BED (TYP) 4. ADDITIONAL PART OF NOISE BARRIER : O20361-C-VIA-00-NU-42640.
L=5000
8180 8180 8180 8180 8180 8180 8380 8380 8380 8380 8380 2100 9978 1250 5. METAL FENCE FOR EACH OHE MAST FOUNDATION : O20361-C-VIA-00-NU-42634 TO 42637,42868 TO 42871

2420
32mm UPVC PIPE
CL OF DN TRACK 1400 CL OF EVACUATION 6. METAL FENCE AT EXPANSION JOINT GAP :
1500 SLEEVE ON DECK
O20361-C-VIA-00-NU-42642 & 42643.

WIDE DECK
BARRIER L FOR EARTHING (TYP)

8300
1400

9060
CL OF ALIGNMENT CL TC AT SP06 7. METAL FENCE FOR COMBINED EJ & OHE MAST :

11900
WATER STOPPER (TYP)

2080
CL OF YESB AT TRACK
(REF. NOTE CIRCUIT FEEDING SECTION O20361-C-VIA-00-NU-42750 & 42751.
TRACK BED DRAINAGE SPOUT (TYP) TRACK BED NO. : 9b) (REF. NOTE NO. : 9) 8. EVACUATION BARRIER :

45°
150 1150 9000

300
CL OF UP TRACK EARTHING CABLE (TYP) O20361-C-VIA-00-NU-42740 & 42741.

2420
ADDITIONAL CONCRETE
COVER (TYP) 9. CABLE PULL PIT AND CONDUIT FOR INSTALLATION OF EMERGENCY STOP BUTTON AT LIGHT SECTION
(SESB) :
EVACUATION BARRIER
O20361-C-VIA-00-NU-42742, (BD-JIC-E1-DRW-ALL-GNL-T06-10027-000)
O20361-C-VIA-00-NR-42743 &
DECK SLAB
O20361-C-VIA-00-NR-42744.
EARTHING CABLE (TYP) NOTE: 9a. EQUIPMENT INSTALLATION WIDENING AND CABLE CROSSING PIPE CONDUIT
G OHE MAST FDN. EJ FOR ADJUSTING CONCRETE (TYP) NOISE BARRIER (TYP) '1' (REF. NOTE NO. : 13) PRECAST DUCT (TYP)
RB OHE MAST FDN. G
875 875 875 875 1. L=675mm WITHOUT DUCT DETOUR. (FOR LCX RELAY)
2. L=1055mm WITH DUCT DETOUR. O20361-C-VIA-00-NU-42716. (BD-JIC-E1-DRW-ALL-GNL-T06-10003-000)
B2 B'3 A1 A1 B'3 B2 B1-1 B'1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-1 B1-1 B2 B'3 A1 A1 B3 B2 B'1-1 B'1-1 B1-3 C2 B1-3 B'1-2 B1-2 B'1-2 B1-2 C1 B1-2 B'1-1 B'1-1 B2 B3 A1 A1 B3 B2 B1-1 B1-1
SECTION - A-A 9b. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
2500 2600 2350 2350 2600 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2600 2350 2350 2100 2500 2000 2000 2500 1750 2500 2000 2500 2000 2500 1750 2500 2000 2000 2500 2100 2350 2350 2100 2500 2500 2500 (TO BE PROVIDED IN ALL EJ LOCATIONS ON EITHER SIDE OF GIRDER) O20361-C-VIA-00-NU-42753. (BD-JIC-E1-DRW-ALL-GNL-T06-10001-000)
(SCALE 1:15) 9c. CONDUIT FOR INSTALLATION OF EMERGENCY STOP BUTTON AT LIGHT SECTION (SESB) :
537 562 1x1000 NB 550
1x900 NB 1x900 NB 1x900 NB O20361-C-VIA-00-NU-42756. (BD-JIC-E1-DRW-ALL-GNL-T06-10028-000)
10x1000 NB 1440 24x1000 NB 11x1000 NB 1438 9x1000 NB 6x900 NB 7x1000 NB 11x1000 NB 9d. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
1x750 NB 573 1x750 NB 573 1x750 NB 600 3x700 NB O20361-C-VIA-00-NU-42757. (BD-JIC-E1-DRW-ALL-GNL-T06-10012-000)
3x700 NB 3x700 NB
1x700 NB 1x700 NB 2x900 NB 2x700 NB 9e. WIDENING AND TRANSVERSE CONDUIT FOR EQUIPMENT INSTALLATION. :
O20361-C-VIA-00-NU-42715. (BD-JIC-E1-DRW-ALL-GNL-T06-10002-000)
PLAN AT DECK SLAB LEVEL 9f. TRANSVERSE CONDUIT FOR TELEPHONE LINE AT SMD/RAMP LOCATION.
(SCALE 1:200) O20361-C-VIA-00-NU-42745. (BD-JIC-E1-DRW-ALL-GNL-T06-10028-000)
10. DRAINAGE PLAN FOR BOX GIRDER :
255P17 CH : 255719 255P18 CH : 255764 255P19 CH : 255809 O20361-C-VIA-00-NU-42611 TO 42614.
45000 45000 11. OPENING IN DECK SLAB (TYPE 1 TO 3) :
255GR17 (SBS) [BR NO - 1140] 255GR18 (SBS) 570
1x750 NB 2x900 NB 550 1x700 NB O20361-C-VIA-00-NU-42648 TO 42650. (SD-JIC-C01-DRW-ALL-VDT-B99-10404-004,10405-004,10406-002)
CL OHE MAST FDN. CL OHE MAST FDN. 1x750 NB O20361-C-VIA-00-NR-42654 TO 42657.
F 7x1000 NB
1x1000 NB
* 2x700 NB
15375 29625 *
7x1000 NB 19x1000 NB 13375 DECK SLAB OPENING TYPE 1 & 3 SHALL BE PROVIDED ON BOTH GIRDERS AT EJ F
50 50 50 50 15375 L=5000 29625 1x900 NB 50 50 LOCATION.
3761 8200 9250 10000 9250 8200 8000 5524 10000 8000 8000 5376 8180 12. ANCHOR FOUNDATION :
O20361-C-VIA-00-NU-42659. (SD-JIC-C01-DRW-ALL-VDT-B99-10502-008)
O20361-C-VIA-00-NU-42663. (SD-JIC-C01-DRW-ALL-VDT-B99-10506-006)
1790 11000 2000 2000 O20361-C-VIA-00-NR-42661. (SD-JIC-C01-DRW-ALL-VDT-B99-10504-008)
EJ FOR TRACK BED (TYP) 620 1460
L=5000 O20361-C-VIA-00-NR-42665 (SD-JIC-C01-DRW-ALL-VDT-B99-10508-006)
8380 2100 9978 1250 750 9978 9978 9978 4988 9978 9978 5000 9978 9978 4988 8180 8180
O20361-C-VIA-00-NR-42666 (SD-JIC-C01-DRW-ALL-VDT-B99-10509-004)
1400 CL OF EVACUATION 555 1395 3037 CL OF EVACUATION 13. EARTHING ARRANGEMENT FOR VIADUCT INTERMEDIATE AND CENTER POLE - BOX GIRDER
BARRIER BARRIER O20361-E-VIA-00-GA-59511 (SD-JIC-C01-DRW-ALL-VDT-B99-10602-008)
CL TC AT SP06 CL OF YESB AT TRACK WIDENING AND TRANSVERSE CONDUIT FOR
LEVEL PEG 13a. EARTHING ARRANGEMENT FOR VIADUCT END POLE - BOX GIRDER
(REF. NOTE CIRCUIT FEEDING SECTION EQUIPMENT INSTALLATION (FOR LCX REPEATER)
TRACK BED (REF. NOTE NO. : 16) O20361-E-VIA-00-GA-59512 (SD-JIC-C01-DRW-ALL-VDT-B99-10602-008)
NO. : 9b) (REF. NOTE NO. : 9) (REF NOTE NO. : 9a)
1150 9000 13b. EARTHING ARRANGEMENT FOR MISCELLANEOUS STRUCTURES ON VIADUCT
19580
O20361-E-VIA-00-GA-59513
555 1395 14. PRECAST DUCTS :
EVACUATION BARRIER EVACUATION BARRIER O20361-C-VIA-00-NU-42667 TO 42669.
O20361-C-VIA-00-NU-42672 & 42673.
O20361-C-VIA-00-NU-42676 TO 42679.
E E
O20361-C-VIA-00-NR-42670 & 42671.
METAL FENCE (TYPE - A) OPENING IN DECK TYPE-1 - S & T
OHE MAST FDN. EJ FOR ADJUSTING CONCRETE (TYP) OHE MAST FDN. OHE MAST FDN. O20361-C-VIA-00-NR-42674 & 42675.
PRECAST DUCT (TYP) FOR EJ (TYP.) NOISE BARRIER (TYP) (350X350) (TYP.)LCX REPEATER '2'
875 875 METAL FENCE (TYPE - A) FOR OHE MAST (TYP.) 875 875 (REF. NOTE NO.: 11) 875 O20361-C-VIA-00-NR-42680 & 42681.
B'1-1 B2 B3 A1 A1 B3 B2 B1-1 B1-1 B1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-2 B1-1 B1-1 B2 B3 A1 A1 B3 B2 B1-1 B1-1 B1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-2 B1-1 B1-1 B2 B3 A1 A1 B'3 B2 B1-1 B'1-3 O20361-C-VIA-00-NR-42683 TO 42688.
O20361-C-VIA-00-NU-42841 & 42842.
2000 2500 2100 2350 2350 2100 2500 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2500 2100 2350 2350 2100 2500 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2500 2100 2350 2350 2600 2500 2500 2500
O20361-C-VIA-00-NU-42845 & 42846.
1x1000 NB O20361-C-VIA-00-NU-42848 & 42849.
550 1x900 NB 562 562 O20361-C-VIA-00-NR-42843 & 42844.
7x1000 NB 11x1000 NB 1488 24x1000 NB 12x1000 NB 1418 23x1000 NB 10x1000 NB
O20361-C-VIA-00-NR-42847.
1x750 NB
2x900 NB 2x700 NB
600 3x700 NB 3x700 NB 3x750 NB 3x700 NB 2x700 NB 1x700 NB * 2x750 NB
570
537 3x700 NB O20361-C-VIA-00-NR-42850 TO 42856.
1x750 NB 1x1000 NB
PLAN AT DECK SLAB LEVEL 15. PANEL SIZE FOR ADJUSTING CONCRETE FOR ELECTRICAL CABLE DUCT ARE MARKED IN THIS DRAWING.
FOR DOWEL , ADDITIONAL REINFORCEMENT IN DECK SLAB AND OTHER DETAILS REFER DRAWING NO. :
(SCALE 1:200)
A O20361-C-VIA-00-NR-42692 TO 42695, 42747,42748,42872,42836 & 42837
16. DETAILS OF LEVEL PEGS :
O20361-C-VIA-00-MS-61305.
17. PANEL SIZE FOR TRACK BED ARE MARKED IN THIS DRAWING. FOR DOWEL AND OTHER DETAILS REFER
DRAWING NO. :
D 255P19 CH : 255809 255P20 CH : 255850 32mm UPVC PIPE
O20361-C-VIA-00-NR-42732 & 42733, O20361-C-VIA-00-NR-42737 & 42738. D
SLEEVE ON DECK 750 750
41000 FOR EARTHING (TYP) 18. FOR INSPECTION LADDER REFER DRAWING NO. :
570 255GR19 (SBS) 32mm UPVC PIPE O20361-C-VIA-00-NU-42699.
1x700 NB SLEEVE ON DECK 300 300
CL OHE MAST FDN. 19. TRANSVERSE CONDUIT FOR BRANCH LIGHTING AND MAINTENANCE OUTLET :O20361-C-VIA-00-NU-42746
1x750 NB FOR EARTHING (TYP) (TYP) (TYP)
13375 27625 13375 20. OHE FOUNDATION DETAIL REFER RESPECTIVE GIRDER DRAWING.
1x900 NB 50 50 50 50 21. RAILING, ACCESS LADDER, LANDING AND DOOR DETAILS FOR MAINTENANCE GALLERY
O20361-C-VIA-00-NU-42638,42639 & 42714
5376 8180 8180 8180 8180 8180 8180
GENERAL NOTES:
2000 2000 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. DIMENSIONS SHALL NOT BE SCALED.
4988 8180 8180 8180 8180 8180 8180
3. LOCATION OF OHE MAST, ANCHOR LOCATIONS AND OPENING SHOWN ABOVE ARE AS
2420

3037 CL OF DN TRACK PER EMPLOYER LETTER NO : TCAP/MAHSR/PMC/C4/2022/DN/0760 DATED 15.04.2022

675
WIDE DECK

AND TCAP/MAHSR/PMC/C4/2022/IFC/1186 DATED 02/07/2022.


CL OF ALIGNMENT VARIES 100 VARIES
11900

CL OF EVACUATION
2080

4. LOCATION OF S&T SPACE OPENING AND CONDUIT SHOWN ABOVE ARE AS PER
BARRIER EJ GAP
EMPLOYER LETTER NO. :
TCAP/MAHSR/PMC/C4/2022/INT/0770 DATED 16.04.2022.

675
CL OF UP TRACK CL OF EJ
2420

C 5. DRAWINGS GIVEN WITHIN PARENTHESIS ARE CONTRACT DRAWING NUMBERS. C


6. ANCHOR FOUNDATION AND METAL FENCE (OHE & EJ) SHALL BE OF TYPE-A UNLESS
EVACUATION BARRIER NOTED OTHERWISE.
7. ADDITIONAL HEIGHT OF NOISE BARRIER, ANCHOR FOUNDATION TYPE-B, METAL FENCE
TYPE-B (OHE & EJ) SHALL BE PROVIDED FOR RESIDENTIAL / URBAN AREAS
G IN DECK TYPE-1 - S & T 400 400 SPECIFICALLY MARKED IN THE DRAWING AND APPOVED BY THE ENGINEER.
) (TYP.)LCX REPEATER OHE MAST FDN.
875 875
PRECAST DUCT (TYP) NOISE BARRIER (TYP) OHE MAST FDN. A 800
8. WHEREVER S&T EQUIPMENT ARE COMBINED WITH OHE DETOURING, ITS LENGTH
SHALL BE AS PER DECK FURNISHING DRAWING. HOWEVER, ITS SERVICE
B3 A1 A1 B'3 B2 B1-1 B'1-3 C2 B1-3 B1-2 B1-2 B1-2 B1-2 C1 B1-1 B1-1 B2 B'3 A1 A1 B'3 B2 535 535 REQUIREMENTS SUCH AS CONDUITS, PEDESTAL, SPACE ETC, SHALL BE AS PER

2500 2100 2350 2350 2600 2500 2500 2500 1750 2500 2500 2500 2500 2500 1750 2500 2500 2500 2600 2350 2350 2600 2500 1070 DETAIL - '2' REFERENCE DETAIL DRAWINGS GIVEN IN THE NOTES.

(TYPE-1 - S & T)
1x900 NB 537 DETAIL - '1' RB (TYP. DETAIL OF EARTHING SLEEVE AT OPENING LOCATION)
10x1000 NB 1440 24x1000 NB 10x1000 NB
METAL FENCE FOR EJ
(SCALE 1:10)
(SCALE 1:15) TECHNICAL DESIGN
THE CONTRACTOR SHALL ENSURE ALL THE INTERFACE REQUIREMENTS
2x750 NB 537 3x700 NB 1x750 NB OWNER:

W
570 573
KEY PLAN:
PLAN AT DECK SLAB LEVEL 1x700 NB DURING ALL THE STAGES OF EXECUTION

N
m

S
NATIONAL HIGH SPEED RAIL

H
K
CH:264.580Km
(SCALE 1:200)

07. SURAT

ARUC
3.110
TART
0Km

E
06. BILIMORA
B

CH:218.533Km
CH:1 5. VAPI
B CORPORATION LTD.

0Km

CH:393.700Km
C-4 END
ABBREVIATIONS

56.60

08. BH
CH:32
C-4 S
2nd FLOOR, ASIA BHAWAN, ROAD NO-205

67.94
0
SEC-09, DWARKA, New Delhi -110077

CH:1
NB - NOISE BARRIER (TYPE - A / B)

Km

CH:333.276Km
EQ - EQUAL

Km

CH:333.606Km
10 m

.027
SEC-03

0K
Km

.287
UNO - UNLESS NOTED OTHERWISE

77

297
CH 241.
CH:210.273Km

297
CH:210.483Km

5
DWG.NO:

1 .

CH:
*

:24
- NOISE BARRIER AT NARROW LOCATION (TYPE-B).

CH:
CH
TD-NHS-LNT-C4-B06-VDT-B99-010136-001 SEC-01 SEC-02 SEC-04 SEC-05

CONTRACTOR: DESIGNER: PROJECT TITLE:


REVISIONS QUALITY ASSURANCE
L&T Construction MUMBAI - AHMEDABAD HIGH SPEED RAIL PROJECT
The responsibility of control, check and verification of accuracy, correctness,
LARSEN & TOUBRO LTD Package No. MAHSR - C - 4 (Km.156.600 - Km.393.700)
completeness, integration, interfacing with other disciplines and full compliance of Heavy Civil Infrastructure,EDRC
contract provisions in respect of design analysis and drawings rests with the DWG TITLE:
A contractor. PROJECT TITLE: SECTION - 03 (Km.241.770 - Km.297.027) A
Design and Construction of Civil and Building Works including Testing and Commissioning
NAME SIGN DATE on Design Build Lump Sum Price Basis for Double Line High Speed Railway involving DECK FURNISHING LAYOUT
DRAWN BY ANIL PADAVAL 25.04.2022
Viaducts, Bridges, Maintenance Depots, Tunnel, Stations (Vapi, Bilimora, Surat and PIER FROM 255P15 TO 255P20
Bharuch), and Surat Depot between Zaroli Village at Maharashtra-Gujarat Border (MAHSR REV:
B 06.09.2022 REVISED IN LINE WITH SRR 12797 COMMENTS BJ SDD SSR KGN DESIGNED BY SUMEET DIVATAGI 25.04.2022 Km. 156.600) and Vadodara (MAHSR Km. 393.700), excluding Works for 04 No. PSC
Bridges and 07 No. Steel Truss Bridges, in the State of Gujarat and the Union Territory of
DWG No: O20361-C-VIA- 03-GA-44250 B
A 25.04.2022 FOR APPROVAL AJP SDD SSR KGN CHECKED BY SAMSON 25.04.2022 SCALE: SIZE:
Dadra and Nagar Haveli for the Project for Construction of Mumbai - Ahmedabad High
CHECKED BY REVIEWED BY APPROVED BY CHECKED BY REVIEWED BY APPROVED BY PRELIMINARY INFORMATION APPROVAL CONSTRUCTION AS SHOWN A1
REV DATE DESCRIPTION DRAWN DSGN CHKD APPD APPROVED BY GANESH K 25.04.2022 Speed Rail
12 11 10 9 8 7 6 5 4 3 2 1