Crouzet Pneumatic Logic 357236
Crouzet Pneumatic Logic 357236
Crouzet Pneumatic Logic 357236
Overview
b Switching
b Control systems
b Directional control
www.crouzet.com
Contents Editorial
For over 50 years, Crouzet has
established a reputation for providing
micro-control products, micro-motors
and position sensors. Read on to
discover Crouzet's complete offer of
Pneumatic products for industrial and
explosive atmospheres.
b Presentation of the offer P. 4-5
Always one step ahead of market trends and customer
requirements, Crouzet is continually developing its range of both
standard and customised automation components and solutions to
cover all the latest commercial and industrial applications and meet
the needs expressed by manufacturers of automated equipment
and machinery.
Throughout the world, Crouzet the adaptation specialist provides
you with technical and industrial expertise to ensure seamless
b Overview of the offer P. 6-29
integration, whatever the equipment environment or operating
requirements of the machine.
CST (Custom Sensors & Technologies) Business Unit incorporates
the companies BEI, Crouzet, Crydom & Kavlico. In addition to the
Pneumatic solutions contained in this catalogue, CST also offers
a complete range of detection, motorisation and micro-control
products and solutions. This new organisation means even better
service and technical choices for our customers.
b ATEX Directive Crouzet's Quality Control System has integrated environmental
94/9/EC P. 30-31
management into its processes. The production sites are ISO 9001
and ISO 14001 certified.
b Catalogues
& websites P. 32-33
b Sales and
technical support P. 36
www.crouzet.com
2
support
Exhaust
Open/close
flow control
For more application examples, go to Pneumatic actuators for quarter-turn or proportional taps and valves allow open/close
commands and flow rate changes to be automated.
the Pneumatics section on our website: The pneumatic actuating cylinder is operated by means of an air distributor valve built
www.crouzet.com into the valve body and controlled by a solenoid valve.
www.crouzet.com
3
This guide has been designed to help you quickly identify the appropriate products for your
requirements. Most of our pneumatic components are available in a standard range and a range for use
in explosive atmospheres (ATEX): this information is given in the right-hand column on each page.
b Industrial range
The standard range of pneumatic components is designed to meet
requirements for industrial applications.
The operating characteristics (pressure, flow rate, service life, etc.)
have been optimised to best meet these needs.
www.crouzet.com
4
All our push-in connections are designed to be connected to semi-rigid tubes complying with standard
NFE 49100.
All our products are designed to operate with 50 µ filtered non lubricated air.
Memorise
Amplify
Restric
ATEX version
Signal
Detect
Pilot
Manually operated valves b Flow rate 200 Nl/min b ✔ (1)
P. 6-7-8 b Button Ø 22 mm b ✔ (1)
(1)
Note: Manual control valves are deemed to be simple slow-moving components, without any hot surfaces, and are not subject to ATEX Directive 94/9/EC.
They can be integrated in devices and equipment conforming to the requirements of this Directive without adversely affecting conformity.
Nonetheless, parts of these components made of polymer can have an electrostatic charge and the user must take account of these charges.
www.crouzet.com
5
Products
P r Part number Function Outputs Fixing Environment
3/2 valves Industrial ATEX explosive
81280010 NO Side Frame ✔ ✔ (1)
81280510 NC Side Frame ✔ ✔ (1)
81281010 NO Rear Frame ✔ ✔ (1)
81281510 NC Rear Frame ✔ ✔ (1)
81282010 NO Side Clips ✔ ✔ (1)
81282510 NC Side Clips ✔ ✔ (1)
81283010 NO Side Nut ✔ ✔ (1)
81283510 NC Side Nut ✔ ✔ (1)
www.crouzet.com
6
Toggles
24679174 Toggle, black, 2 positions ✔ ✔ (1)
24679175 Lever toggle, black, 2 positions ✔ ✔ (1)
Key toggles
24679180 Key toggle, 2 positions - removal at 0 ✔ ✔ (1)
(1)
Manual control valves are deemed to be simple slow-moving components, without any hot surfaces, and are not subject to ATEX Directive 94/9/EC.
They can be integrated in devices and equipment conforming to the requirements of this Directive without adversely affecting conformity.
Nonetheless, parts of these components made of polymer can have an electrostatic charge and the user must take account of these charges.
www.crouzet.com
7
Applications
Pneumatic timing
(setting t1)
2
Cylinder controls
Air supply
Exhaust
Marking
1
Air
Detection of presence of part
1 Presence of part
2 Cylinder control
t1
Pneumatic timing
(setting t1 - setting t2)
1
Fill control
2
Anti-drip withdrawal
control
Air supply
Control pedal
www.crouzet.com
8
Applications
Exhaust
4
1
Emergency stop
1
Air supply
3
1
www.crouzet.com
9
Detectors
Accessories
70507524 Lever 161A R = 25.4 for detector V3 Flat lever
70507529 Lever 161E R = 24.1 for detector V3 Roller
ATEX explosive atmosphere
DDP(3) 3/2 - V3 - actuating force < 0.5 N NC
DDP(3) 3/2 - V3 - actuating force < 0.5 N NO
Miniature
81921501 DDP(3) 3/2 actuating force < 18 N NC Single plunger
81921505 DDP(3) 3/2 threaded barrel Ø M12 NC Single plunger
actuating force < 21 N
81921601 DDP(3) 3/2 actuating force < 18 N NC Single plunger
81921701 DDP(3) 3/2 NC Plastic roller
81921702 DDP(3) 3/2 NC Roller-bearing roller
81921707 DDP(3) 3/2 NC Plastic idle-return roller
81921712 DDP(3) 3/2 NC Roller-bearing idle-return roller
81921714 DDP(3) 3/2 exhaust with barb connector NC Roller-bearing roller
81921716 DDP(3) 3/2 Viton ® O-ring NC Plastic roller
81921717 DDP(3) 3/2 exhaust with barb connector NC Roller-bearing roller
81921718 DDP(3) 3/2 exhaust with barb connector NC Plastic idle-return roller
81921719 DDP(3) 3/2 exhaust with barb connector NC Roller-bearing roller
81921806 DDP(3) 3/2 exhaust with barb connector NC Plastic roller
81921814 DDP(3) 3/2 exhaust with M5 connector NC Roller-bearing roller
81921901 DDP(3) 3/2 exhaust with barb connector NO Plastic roller
81921902 DDP(3) 3/2 exhaust with barb connector NO Roller-bearing roller
81921911 DDP(3) 3/2 exhaust with barb connector NO Plastic roller
81921912 DDP(3) 3/2 exhaust with barb connector NO Roller-bearing roller
Compact
81922010 DDP(3) 3/2 NC Programmable rotary head, no lever
81922205 DDP(3) 3/2 NC Rotary head, action to right - roller-bearing roller lever
81922210 DDP(3) 3/2 NC Programmable rotary head, no lever
81922211 DDP(3) 3/2 NC Programmable rotary head, no lever
81922401 DDP(3) 3/2 smooth barrel NC Roller plunger
81922521 DDP(3) 3/2 smooth barrel NC Single plunger
Accessories
79452103 Roller lever Plastic roller
79452104 Roller lever Roller-bearing roller
79452123 Adjustable roller lever Plastic roller
79452124 Adjustable roller lever Roller-bearing roller
79452133 Rod lever Adjustable rod
Special
81371401 Inductive proximity sensor Change in air flow
Sensing distance 6 - 10 mm Ø M12 (1)
81372201 Movement sensor Break in air flow
Sensing distance 0 - 18 mm, open-ended (1)
81372401 Movement sensor Break in air flow
Sensing distance 0 - 100 mm - Ø M12 (1)
81372901 Sensor with palette (1)- 100 mm/200 mm Palette
81504025 Pressure decay sensor Pressure drop
Tripping threshold at 6 bar: 0.3 bar
81512201 Ball-actuated detector, actuating force Ball
0.8 N (2), with leakage
81512401 Wire-actuated leak sensor, actuating force Wire
0.025 N (2), with leakage
81923001 Threaded barrel plunger detector NC Single plunger
Ø M12, actuating force < 16 N
(1) For use with amplifiers part no. 81510001 - (2) For use with relays for leak detectors part no. 81502435 or part no. 81505435 - (3) DDP: position detector
www.crouzet.com
10
✔
✔
ATEX part number Certification type Approval
81290006 CE ExII2GcIIBT6 INERIS 18408/05
81290506 CE ExII2GcIIBT6 INERIS 18408/05
0.5 - 2.5 bar Barbs for int. tube Ø 2.7 mm -20°C V +70°C ✔
0.5 - 2.5 bar Barbs for int. tube Ø 2.7 mm -20°C V +70°C ✔
0.5 - 2.5 bar Barbs for int. tube Ø 2.7 mm -20°C V +70°C ✔
www.crouzet.com
11
Sequencer modules
81550001 Sequencer module Locking 2 - 8 bar
81550201 Sequencer module Reset 2 - 8 bar
81550401 Sequencer module Offset and locking 2 - 8 bar
81550601 Sequencer module Offset and reset 2 - 8 bar
Logic elements
81501025 YES element With pressure indicators Yellow 2 - 8 bar
81501065 YES element With pressure indicators and manual Yellow 2 - 8 bar
override
81503025 YES element with threshold With threshold and pressure indicators Orange 2 - 8 bar
81504025 NO element With pressure indicators Light grey 2 - 8 bar
81506025 NO element with threshold Inhibit with pressure indicators Dark grey 2 - 8 bar
81521501 OR element With pressure indicators Blue 2 - 8 bar
81522501 AND element With pressure indicators Green 2 - 8 bar
81540001 Plug-in OR element Blue 2 - 8 bar
81540005 Plug-in OR element Blue 2 - 8 bar
81541001 Plug-in AND element Green 2 - 8 bar
81541005 Plug-in AND element Green 2 - 8 bar
Memories
81523201 Memory Pressure indicator 2 - 8 bar
81523601 Memory Pressure indicator and manual override 2 - 8 bar
Timers
81503540 Fixed timer (0.4 s) Positive output 2 - 8 bar
81503710 Adjustable timer (0.1 to 15 s) Positive output 2 - 8 bar
81503716 Adjustable timer (0.1 to 5 s) Positive output 2 - 8 bar
81503720 Adjustable timer (0.1 to 30 s) Positive output 2 - 8 bar
81503725 Adjustable timer (0.1 to 60 s) Positive output 2 - 8 bar
81506540 Fixed timer (0.4 s) Negative output 2 - 8 bar
81506710 Adjustable timer (0.1 to 15 s) Negative output 2 - 8 bar
81506720 Adjustable timer (0.1 to 30 s) Negative output 2 - 8 bar
81506725 Adjustable timer (0.1 to 60 s) Negative output 2 - 8 bar
81506920 Adjustable frequency generator 0.04 - 12 Hz 2 - 8 bar
81506940 Adjustable frequency generator 0.02 - 8 Hz 2 - 8 bar
81506944 Adjustable frequency generator 0.02 - 3 Hz 2 - 8 bar
81507540 Fixed-length single pulse generator (0.4 s) Negative output 2 - 8 bar
81507542 Fixed-length single pulse generator (0.8 s) Negative output 2 - 8 bar
81507720 Adjustable-length single pulse generator Negative output 2 - 8 bar
(1 to 30 s)
Accessories
79451698 Panel-mounted adaptor (part no. 81503710 and part no. 81506710)
79451903 Panel-mounted adaptor (part no. 81503720 and part no. 81506720)
79451904 Panel-mounted adaptor (part no. 81507720)
79451905 Panel-mounted adaptor (part no. 81506940)
www.crouzet.com
12
150 Nl/min On sub-base for register (pages 14 - 15) -5°C V +50°C ✔ 81550013 ExII2GDcIIB65°CT6 INERIS 18409/05
150 Nl/min On sub-base for register (pages 14 - 15) -5°C V +50°C ✔ 81550213 ExII2GDcIIB65°CT6 INERIS 18409/05
150 Nl/min On sub-base for register (pages 14 - 15) -5°C V +50°C ✔ 81550403 ExII2GDcIIB65°CT6 INERIS 18409/05
150 Nl/min On sub-base for register (pages 14 - 15) -5°C V +50°C ✔ 81550603 ExII2GDcIIB65°CT6 INERIS 18409/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81501031 ExII2GDcIIB65°CT6 INERIS 18408/05
171 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81501066 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81503028 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81504035 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506027 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81521508 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81522505 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min Push-in for ext. tube Ø 4 mm -5°C V +50°C ✔ 81540015 ExII2GDcIIB65°CT6 INERIS 18408/05
200 Nl/min Push-in for ext. tube Ø 6 mm -5°C V +50°C ✔ 81540017 ExII2GDcIIB65°CT6 INERIS 18408/05
170 Nl/min Push-in for ext. tube Ø 4 mm -5°C V +50°C ✔ 81541015 ExII2GDcIIB65°CT6 INERIS 18408/05
200 Nl/min Push-in for ext. tube Ø 6 mm -5°C V +50°C ✔ 81541017 ExII2GDcIIB65°CT6 INERIS 18408/05
200 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81523205 ExII2GDcIIB55°CT6 INERIS 17564/04
200 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81523608 ExII2GDcIIB55°CT6 INERIS 17564/04
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81503543 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81503728 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81503729 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81503731 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506541 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506714 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506721 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506727 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81506945 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81507543 ExII2GDcIIB60°CT6 INERIS 18410/05
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔
170 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81507724 ExII2GDcIIB60°CT6 INERIS 18410/05
www.crouzet.com
13
www.crouzet.com
14
Push-in for ext. tube -5°C V +50°C ✔ 79458018 ExII2GDcIIB90°CT5 INERIS 18410/05
Ø 4 mm
On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81520 602 EXII2GDcIIBT6 INERIS 18410/05
open 30 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81525106 ExII2GDcIIB60°CT6 INERIS 18410/05
open 200 Nl/min On sub-base (pages 14 - 15) -5°C V +50°C ✔ 81526006 ExII2GDcIIB60°CT6 INERIS 18410/05
180 at 300 Nl/h at 4 bars Push-in for ext. tube -5°C V +50°C ✔ 81529013 ExII2GDcIIB60°CT6 INERIS 18410/05
350 at 500 Nl/h at 4 bars Ø 4 mm -5°C V +50°C ✔ 81529014 ExII2GDcIIB60°CT6 INERIS 18410/05
580 at 770 Nl/h at 4 bars -5°C V +50°C ✔ 81529015 ExII2GDcIIB60°CT6 INERIS 18410/05
800 at 1060 Nl/h at 4 bars -5°C V +50°C ✔ 81529016 ExII2GDcIIB60°CT6 INERIS 18410/05
1100 at 1390 Nl/h at 4 bars -5°C V +50°C ✔ 81529017 ExII2GDcIIB60°CT6 INERIS 18410/05
1450 at 1650 Nl/h at 4 bars -5°C V +50°C ✔ 81529018 ExII2GDcIIB60°CT6 INERIS 18410/05
2300 at 2800 Nl/h at 4 bars -5°C V +50°C ✔ 81529020 ExII2GDcIIB60°CT6 INERIS 18410/05
80 at 120 Nl/h at 4 bars -5°C V +50°C ✔ 81529026 ExII2GDcIIB60°CT6 INERIS 18410/05
Push-in for ext. tube -5°C V +50°C ✔ 81551004 ExII2GDcIIBT6 INERIS 18409/05
Ø 4 mm -5°C V +50°C ✔ 81551104 ExII2GDcIIBT6 INERIS 18409/05
Push-in for ext. tube -5°C V +50°C ✔ 81531008 ExII2GDcIIBT6 INERIS 17564/04
Ø 4 mm
-5°C V +50°C ✔ 81532009 ExII2GDcIIBT6 INERIS 18408/05
-5°C V +50°C ✔ 81532109 ExII2GDcIIBT6 INERIS 18408/05
www.crouzet.com
15
Automation controls
Pressure switches
81509080 Pressure switch No manual override Pressure 1.4 ± 0.5 bar 5 A - 220 V a
81509085 Pressure switch With manual Pressure 1.4 ± 0.5 bar 5 A - 220 V a
override
81513501 Pressure switch with On DIN rail No manual override Low pressure 0.3 - 1.2 bar 5 A - 220 V a
pressure indicator (Omega)
81513502 Pressure switch with On DIN rail No manual override Pressure 2 - 8 bar 5 A - 220 V a
pressure indicator (Omega)
81513509 Low-hysteresis On DIN rail No manual override Pressure 3 - 8 bar 5 A - 220 V a
pressure switch with (Omega)
pressure indicator
81513510 Pressure switch With manual Pressure 2 - 8 bar 5 A - 220 V a
override
81513516 Pressure switch No manual override Pressure 2 - 8 bar 5 A - 220 V a
81513518 Pressure switch with On frame No manual override Low pressure -0.3 - 1.2 bar 5 A - 220 V a
Viton ® membrane
81513533 Pressure switch On frame No manual override Pressure 2 - 8 bar 5 A - 220 V a
81513535 Pressure switch with On frame No manual override Pressure 3 - 8 bar 5 A - 220 V a
Viton ® membrane and
pressure indicator
81513552 Pressure switch with On DIN rail With manual Pressure 2 - 8 bar 5 A - 220 V a
pressure indicator (Omega) override
81513561 Pressure switch On DIN rail With manual Pressure 3 - 8 bar 5 A - 220 V a
(Omega) override
81513570 Pressure switch On frame No manual override Pressure 0.5 - 3 bar 5 A - 220 V a
81513574 Pressure switch with On DIN rail No manual override Pressure 2 - 8 bar 5 A - 220 V a
pressure indicator (Omega)
Hysteresis Adjustment Repeat
range accuracy
Pressure switches
81502140 Pressure switch Negative output 60 mbar 50 - 500 mbar 10 %
81502150 Pressure switch Negative output 100 mbar 0.1 - 2.5 bar 4%
81502160 Pressure switch Negative output 320 mbar 2 - 8 bar 4%
81505140 Pressure switch Positive output 60 mbar 50 - 500 mbar 10 %
81505150 Pressure switch Positive output 100 mbar 0.1 - 2.5 bar 4%
81505160 Pressure switch Positive output 320 mbar 2 - 8 bar 4%
81505161 Pressure switch, Positive output 320 mbar 2 - 8 bar 4%
leaf-proof
81508150 Pressure switch 100 mbar 2 - 8 bar
with electrical output
81508160 Pressure switch 250 mbar 0.1 - 2.5 bar
with electrical output
Vacuum switches
81502110 Vacuum switch Negative output 80 mbar -0.1 - 0.9 bar
81505110 Vacuum switch Positive output 80 mbar -0.1 - 0.9 bar
81508110 Vacuum switch with Electrical output 80 mbar -0.1 - 0.9 bar
electrical output
81513522 Vacuum switch On DIN rail No manual override Empty -0.3 - 0.8 bar 5 A - 220 V a
(Omega)
81513523 Vacuum switch On frame No manual override Empty -0.3 - 0.8 bar 5 A - 220 V a
81513525 Vacuum switch with On frame No manual override Empty -0.3 - 0.8 bar 5 A - 220 V a
Viton ® membrane
81513527 Vacuum switch No manual override Empty -0.3 - 0.8 bar 5 A - 220 V a
www.crouzet.com
16
Push-in for ext. tube Ø 4 mm -10°C V +70°C MH15213R ✔ 81513530 ExII1GExiaIICT6 LCIE 02ATEX6121X
Flow rate
at 4 bars
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81502141 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81502151 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81502162 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81505141 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81505151 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81505164 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81502111 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔ 81505111 ExII2GDcIIB60°CT6 INERIS 18410/05
On sub-base (pages 14 - 15) -5°C V +50°C 170 Nl/min ✔
www.crouzet.com
17
Automation controls
Relays
For leak detectors
81502435 Relay for leak detector Positive output 5 Nl/min - 6 bar
81505435 Negative output 5 Nl/min - 6 bar
Amplifier relays
81502230 Single amplifier Positive output 5 Nl/min - 4 bar 10 - 20 mbar
81502320 Pressure-sensitive Positive output 5 Nl/min - 4 bar 1 - 4 mbar
amplifier
81505230 Single amplifier Negative output 5 Nl/min - 4 bar 10 - 20 mbar
81505320 Pressure-sensitive Negative output 5 Nl/min - 4 bar 1 - 4 mbar
amplifier
81510001 Amplifier relay On frame Positive output 0.5 - 1.5 mbar
Colour
Indicators
84150201 Pneumatic indicator Ø 22 mm Red
84150202 Pneumatic indicator Ø 22 mm Green
84150203 Pneumatic indicator Ø 22 mm Yellow
84150204 Pneumatic indicator Ø 22 mm Blue
Version
Counters
99766001 Flush-mounting Base-mounted 6 digits, no reset
counter
99766002 Flush-mounting Base-mounted 4 digits, with reset
counter
89538201 Preselection counter Base-mounted 5 digits manual/
pneumatic reset
Version Approval
Controls
Two-hand controls
81580503 Two-hand control 4 x 4.2 mm Type III A- EN 574 EN574
81580504 module screws Type III B - EN 574 EN574
Foot switches
81999501 Pneumatic foot switch
NC
Pneumatic relays
81580101 Pneumatic relay for Sub-base Type III A- EN 574 CE test type
two-hand control 0526 520 1690 0197
81580202 Sub-base Type III B - EN 574 CE test type
0526 520 1690 0197
Version
Vacuum generators
81535 301 Vacuum generator Sub-base
www.crouzet.com
18
Push-in for ext. tube 2 - 8 bar -5°C V +50°C ✔ 84150214 ExII2GDcIIB65°CT6 INERIS 18398/05
Ø 4 mm 2 - 8 bar -5°C V +50°C ✔ 84150215 ExII2GDcIIB65°CT6 INERIS 18398/05
2 - 8 bar -5°C V +50°C ✔ 84150216 ExII2GDcIIB65°CT6 INERIS 18398/05
2 - 8 bar -5°C V +50°C ✔ 84150217 ExII2GDcIIB65°CT6 INERIS 18398/05
2 - 8 bar 0 V +60°C ✔
www.crouzet.com
19
Accessories
81513052 LED Interference suppression and readout
81513055 LED Interference suppression and readout
81513058 LED Interference suppression and readout
81513059 LED Interference suppression and readout
81513064 Indicator seal
81537001 Plug-in silencer Plug-in Ø 6 mm
81537201 Plug-in silencer Plug-in Ø 8 mm
81516081 Pneumatic pilot No manual override/push-in for ext. tube Ø 4 mm
81516082 Connector
81516085 Blanking plate
Sub-bases
81514101 End base for miniature solenoid valve Pneumatic indicator
81514161 Intermediate base for miniature solenoid valve Pneumatic indicator
79453569 CNOMO sub-base for miniature solenoid valve CNOMO NFE 49 066 footprint
79452445 Blanking plate
www.crouzet.com
20
24 V c ✔
24 V c 25 Nl/min ✔
12 V c 25 Nl/min 81519334 ExII1GExiaIICT6 LCIE 02ATEX6121X
24 V c 25 Nl/min ✔ 81519335 ExII1GExiaIICT6 LCIE 02ATEX6121X
48 V c 25 Nl/min ✔
12 V c 25 Nl/min 81519634 ExII1GExiaIICT6 LCIE 02ATEX6121X
24 V c 25 Nl/min ✔ 81519635 ExII1GExiaIICT6 LCIE 02ATEX6121X
24 V a - 50 - 60 Hz 12 Nl/min ✔
110 V a - 50 - 60 Hz 12 Nl/min ✔
220 V a - 50 - 60 Hz 12 Nl/min ✔
24 V a - 50 - 60 Hz 12 Nl/min ✔
48 V a - 50 - 60 Hz 12 Nl/min ✔
110 V a - 50 - 60 Hz 12 Nl/min ✔
220 V a - 50 - 60 Hz 12 Nl/min ✔
24 V a - 50 - 60 Hz 12 Nl/min ✔
48 V a - 50 - 60 Hz 12 Nl/min ✔
www.crouzet.com
21
Zone 5
Zone 4
Zone 3
Zone 2
Zone 1
Solenoid control
Control unit valves
Air blowing
b Description
Pressure-relief mattresses for medical applications make use of an automatic
pressure control system to ensure maximum comfort for each patient.
Pneumatic valves are used to distribute the patient's weight in the best possible way;
by alternating pressures it is possible to reduce the apparent weight on the mattress
for the relief of pressure sores.
www.crouzet.com
22
NC M5 ✔
NC M5 ✔
NC M5 ✔
NC M5 ✔
NC Barbs for int. tube Ø 2.7 mm ✔
NC M5 ✔
NC Barbs for int. tube Ø 2.7 mm ✔
NC M5 ✔
Weaving unit
Worked yarn
Process control
Unprocessed yarn
b Description
Compressed air is used in the textile industry to control the principal functions in yarn
processing (drawing, twisting, threading, attachment and lifting, etc.), minimising the
contact points to improve the reliability of the process.
The winding units are arranged as independent modules in which pneumatic control
is provided by a set (station) of interconnected pneumatic solenoid valves.
www.crouzet.com
23
Valve modules
Valve modules
3/2
81513100 Poppet valve module 200/300 Nl/min 3/2 NC On sub-base (below)
17.5 mm
81513600 Poppet valve module 200/300 Nl/min 3/2 NO On sub-base (below)
17.5 mm
81519732 Poppet valve module 170 Nl/min 3/2 NC On sub-base for logic 24 V c
81519774 17.5 mm 170 Nl/min 3/2 NC elements (pages 14 - 15) 24 V a - 50 - 60 Hz
81519776 170 Nl/min 3/2 NC 110 V a - 50 - 60 Hz
81519777 170 Nl/min 3/2 NC 230 V a - 50 - 60 Hz
81519832 171 Nl/min 3/2 NO 24 V c
4/2 - 5/2 - 5/3
81513200 Poppet valve module 200/300 Nl/min 4/2 monostable On sub-base (below)
17.5 mm
81516100 Valve module 35 mm 300/400 Nl/min 4/2 pressure/spring On sub-base (below)
81516200 Valve module 35 mm 300/400 Nl/min 4/2 pressure/pressure On sub-base (below)
89541007 Valve module 1400 Nl/min 5/2 pressure/spring On sub-base (below)
(ISO size 1)
89541037 Valve module 1400 Nl/min 5/2 pressure/pressure On sub-base (below)
(ISO size 1)
89541047 Valve module 1400 Nl/min 5/3 pressure/pressure On sub-base (below)
(ISO size 1) closed centre
89541067 Valve module 1400 Nl/min 5/3 pressure/pressure On sub-base (below)
(ISO size 1) centre open for
exhaust
Fixing
Sub-bases/Accessories
81513001 Supply module Push-in for ext. tube Ø DIN rail mounting
6 mm (Omega)
81513011 End base Push-in for ext. tube Ø
6 mm
81513012 End base Gas 1/8
81513060 Sub-base 17.5 mm Push-in for ext. tube Ø
4 mm
81513065 Sub-base 17.5 mm Push-in for ext. tube Ø
6 mm
81516085 Blanking plate Plug
81517101 Sub-base 35 mm (1) Push-in for ext. tube Ø DIN rail mounting
4 mm (Omega)
81517201 Sub-base 35 mm (1) Push-in for ext. tube Ø DIN rail mounting
6 mm (Omega)
81543006 Sub-base Push-in for ext. tube Ø Clips for rod Ø 8
(ISO size 1) 6 mm
81543206 Sub-base Push-in for ext. tube Ø Clips for rod Ø 8
(ISO size 1) 8 mm
(1) Sub-base can take 2 valve modules of length 17.5 mm.
www.crouzet.com
24
www.crouzet.com
25
Assembled modules
Option
Valve modules
catalogue pages 20 to 25
Sub-bases
catalogue pages 20 to 25
Final assembly
www.crouzet.com
26
www.crouzet.com
27
Simulation kit
These kits have been designed to simplify wiring and assembly operations for the modules they contain. They can be used
for simulating the principal simple automation systems and for studying the technology of pneumatic elements
Extension module
Standard
81598941 Supplementary 4 kg v 2 sets of electro-pneumatic interfaces
PUMA kit v 1 set of pneumatic-electrical interfaces
The modular relays are configured so that users can explore logic functions and
produce simple or complex automation systems by direct installation.
www.crouzet.com
28
Q = Kv √(∆p/γ)
where:
Q = flow rate (L/min)
∆p = pressure drop (bar)
γ = density of liquid (kg/dm3)
Kv = flow factor for the valve
For water: γ = 1 kg/dm3
Pressures
1 bar = 1.02 kg/cm2 = 0.98 atm = 105 Pa = 100 kPa
= 14.51 psi
1 psi = 0.0689 bar = 0.0703 kg/cm2
Flow rates
Kv in L/min/∆p = 1 bar
Cv in gpm/∆p = 1 psi
1 Kv = 14.28 Cv
1 Cv = 0.07 Kv
6
Kv 20.98 16.67 1 1.166 1.035
5 Ø3
4 Supply pressure:
6 bar
Cv 18 14.3 0.858 1 0.829
3
Ø2
2
1
f 21.7 17.24 0.967 1.206 1
0,5 Ø1 Flow rate
0 100 200 300 400 500 600 700 800 900 (NL/mn)
Factor kv: kv = 1 when 1 litre of water per minute flows through a valve and causes a loss
of pressure of 1 bar
Factor Kv: same definition as for factor kv, but the flow rate is measured in m3 per second
Factor Cv: same definition as for factor kv, but the flow rate is measured in US gallons at
60°F and the loss of pressure is 1 psi
Factor f: same definition as factor Cv, but the flow rate is measured in Imperial gallons
Equivalent cross-section S corresponds to a theoretical port (whose cross-section is expressed
in mm2), located in a pipe and giving rise to the same restriction as the valve in question.
www.crouzet.com
29
General
Classification
b Sparks Heat source b Potentially explosive environments are classified by zone in compliance with
Directive 1999/92/EC. This directive is aimed at users.
It details the minimum requirements for increasing protection of the health and safety
of workers exposed to explosive atmospheres.
b ATEX Directive 94/9/EC defines categories of equipment and protection systems
which can be used in the corresponding zones.
v Categories M1 and M2 relate to mines (group I)
v Categories 1, 2 and 3 relate to other locations (group -II) often referred to as
"Surface industries".
www.crouzet.com
30
Equipment definition
Equipment for surface industry - Group II
Zone 0 20 1 21 2 22
Type of atmosphere
G = Gas G D G D G D
D = Dust
Continuous presence Intermittent presence Fleeting presence
Presence
(or for long periods, (or occasional, (or rare,
Explosive atmosphere
i.e. more than 1000 hours per year) i.e. 10 to 1000 hours per year) i.e. 1 to 10 hours per year)
Category of equipment that
can be used according to 1 2 3
94/9/EC dated 23/03/94
Marking example
Certified products must incorporate marking specific
to Directive 94/9/EC, such as:
CROUZET
Type: 81513530
Serial no:
Year of construction
CE 0081 II 1 G
Ex ia II C T6
LCIE 02 ATEX 6121 X
Max. amb. T: +50°C
Explanation of b Th
The CE marking followed by:
the marking C 0081
CE II 1 G v th
the identification number of the body
example
v the symbol indicating that this product is suitable for use in an explosive
a
atmosphere
v the equipment group (II = surface industries)
- the category: 1 = continuous presence; 2 = intermittent presence; 3 = fleeting
presence
- the type of explosive atmosphere (G = gas; D = dust).
NB: In affixing this CE marking, the manufacturer declares that the product has been manufactured in complete
conformity with the requirements of all the relevant directives.
E
Ex : Symbol indicating that the equipment complies with one or more protection
E ia II C T6 X
Ex methods
ia : Protection method: intrinsic safety
II : Group II (locations other than mines subject to firedamp)
Gas group
C : Subdivision C, including hydrogen, acetylene and carbon disulphide
T6 : Temperature class corresponding to a maximum surface temperature of 85°C
X : Product subject to special conditions for safe usage, as specified on the notice
b Th
The CE Test Certificate type reference (if appropriate).
LCIE 02 ATEX 6121 X
L
LC
b Th
The ambient operating temperature range.
Max. amb. T: +50°C
Ma
www.crouzet.com
31
Available catalogue
www.crouzet.com
32
And also
www.crouzet.com
33
www.crouzet.com
34
www.crouzet.com
35
USA/CANADA
Crouzet North America ITALY INDIA
204 Airline Drive, suite 300 Crouzet Componenti s.r.l. Crouzet India
75019 Coppell Texas Via Viganò De Vizzi, 93/95 Prestige Meridian II
USA 20092 Cinisello Balsamo (Mi) No. 30, 13th Floor,
Tel. : +1 (972) 471 2565 ITALIA Unit No: 1301 & 1302
Fax : +1 (972) 471 2560 Tel. : +39 (02) 66 599 240 Mahatma Gandhi Road
E-mail : [email protected] Fax : +39 (02) 66 599 248 Bangalore 560 001
www.crouzet-usa.com E-mail : [email protected] INDIA
www.crouzet.it Tel.: +91 (0) 80 41132204/05
Fax : +91 (80) 41132206
E-mail : [email protected]
OTHER COUNTRIES www.crouzet.co.in
Crouzet do Brasil Ltda
Rua Gal.Furtado Nascimento, SPAIN/PORTUGAL
740 - sala 77 Crouzet Ibérica TAIWAN
Alto de Pinheiros / 05465-070 C/ Aragón 224, 2° 2a Custom Sensors &
São Paulo - SP 08011 Barcelona Technologies
BRASIL ESPAÑA 3F, No. 39, Ji-Hu Road
Tel. : +55 (11) 3026 9008 Tel. : +34 (93) 484 39 70 Nei-Hu Dist. - Taipei 114
Fax : +55 (11) 3026 9009 Fax : +34 (93) 484 39 73 TAIWAN
E-mail : [email protected] E-mail : [email protected] Tel. : +886 2 8751 6388
www.crouzet.com.br www.crouzet.es Fax : +886 2 2657 8725
E-mail : [email protected]
www.crouzet.tw
EUROPE THE NETHERLANDS
MIDDLE EAST Crouzet BV SOUTH KOREA
Headquartered in Moorpark, California-USA, Custom Industrieweg 17 Custom Sensors &
AFRICA 2382 NR Zoeterwoude
Sensors & Technologies (CST) is made up of the leading NEDERLAND
Technologies
5F, Jeil Bldg.
brands of Crouzet, Kavlico and Crydom, as well as the Tel. : +31 (0) 71-581 20 30 94-46 Youngdeungpo-dong
AUSTRIA Fax : +31 (0) 71-541 35 74 7- ga Youngdeungpo-gu
former divisions of BEI Technologies, including Newall E-mail : [email protected]
Crouzet GmbH Seoul, 150-037
and Systron Donner. CST provides sensors, controls, Zweigniederlassung Österreich www.crouzet.nl SOUTH KOREA
Spengergasse 1/3 Tel. : +82 2 2629 8312
and actuation products to the transportation, industrial, Fax : +82 2 2629 8310
1050 Wien
and aerospace & defense markets. ÖSTERREICH UNITED KINGDOM E-mail : [email protected]
Tel. : +43 (0) 1 36 85 471 Crouzet Ltd www.crouzet.com
www.cstsensors.com Fax : +43 (0) 1 36 85 472 Intec 3 Wade Road
E-mail : [email protected] Basingstoke Hampshire
www.crouzet.at RG24 8NE EAST ASIA & PACIFIC
UNITED KINGDOM Custom Sensors &
Tel. : +44 (0)1256 318 900 Technologies
Fax : +44 (0)1256 318 901 3F, No. 39, Ji-Hu Road
Distributed by : BELGIUM E-mail : [email protected] Nei-Hu Dist. - Taipei 114
Crouzet NV/SA www.crouzet.co.uk TAIWAN
Dieweg 3 B Tel. : +886 2 8751 6388
B - 1180 Uccle Fax : +886 2 2657 8725
BELGIUM E-mail : [email protected]
SWITZERLAND www.crouzet.tw
Tel. : +32 (0) 2 462 07 30 Crouzet AG
Fax : +32 (0) 2 461 00 23 Gewerbepark - Postfach 56
E-mail : [email protected] 5506 Mägenwil
www.crouzet.be SCHWEIZ
Tel. : +41(0) 62 887 30 30
Fax : +41(0) 62 887 30 40
E-mail : [email protected]
www.crouzet.ch Warning:
The product information contained in this
catalogue is given purely as information
and does not constitute a representation,
Crouzet Automatismes SAS Creation-Design: Communication Crouzet warrantly or any form of contractual
commitment. CROUZET Automatismes and
2 rue du Docteur Abel - BP 59 Editing-Publishing: SEDOC, Axess its subsidiaries reserve the right to modify their
products without notice. It is imperative that
26902 Valence CEDEX 9 Photos-Graphics: Daniel Lattard, Schneider Electric we should be consulted over any particular
FRANCE Printing: Imprimerie des Deux Ponts use or application of our products and it is
the responsability of the buyer to establish,
particularly through all the appropriate tests,
www.crouzet.com that the product is suitable for the use or
application. Under no circumstances will
our warranty apply, nor shall we be held
responsible for any application (such as
any modification, addition, deletion, use in
conjunction with other electrical or electronic
CRZ BR 30/A components, circuits or assemblies, or any
Ref. 6760100 EN other unsuitable material or substance) which
has not been expressly agreed by us prior to
07/2008 EN the sale of our products.
Mouser Electronics
Authorized Distributor
Crouzet:
79451905 79451904 79451903 79451698