NIOS 7.3.

0 Release Notes

INTRODUCTION ...................................................................................................................... 2
Supported Platforms............................................................................................................ 2

NEW FEATURES...................................................................................................................... 7
NIOS 7.3.0 ........................................................................................................................ 7

CHANGES TO DEFAULT BEHAVIOR ............................................................................................ 11


NIOS 7.3.0 Release............................................................................................................ 11
NIOS 7.2.x Releases .......................................................................................................... 12
NIOS 7.1.x Releases .......................................................................................................... 12
NIOS 7.0.x Releases .......................................................................................................... 13

CHANGES TO Infoblox API and RESTful API (WAPI) ........................................................................ 13


WAPI Deprecation and Backward Compatibility Policy ............................................................... 14
NIOS 7.3.x Release ............................................................................................................ 14
NIOS 7.0.x Releases .......................................................................................................... 16

UPGRADE GUIDELINES ........................................................................................................... 16


Upgrading to NIOS 7.3.x ..................................................................................................... 16
Upgrading to NIOS 7.2.x ..................................................................................................... 16
Upgrading to NIOS 7.0.x ..................................................................................................... 17

BEFORE YOU INSTALL ............................................................................................................ 18

ACCESSING GRID MANAGER ..................................................................................................... 19

ADDRESSED VULNERABILITIES .................................................................................................. 20

RESOLVED ISSUES ................................................................................................................. 23


Fixed in 7.3.0 .................................................................................................................. 23

KNOWN GENERAL ISSUES ........................................................................................................ 31

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 1 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

INTRODUCTION

Infoblox NIOS 7.3.x software, coupled with Infoblox appliance platforms, enables customers to deploy large,
robust, manageable and cost-effective Infoblox Grids. This next-generation solution enables distributed
delivery of core network services—including DNS, DHCP, IPAM, TFTP, and FTP—with the nonstop availability and
real-time service management required for today’s 24x7 advanced IP networks and applications.

Please note the following:

 NIOS 7.3.x is not supported on the following appliances: IB-250, IB-250-A, IB-500, IB-550, IB-550-A,
IB-1000, IB-1050, IB-1050-A, IB-1550, IB-1550-A, IB-1552, IB-1552-A, IB-1852-A, IB-2000, IB-2000-A,
IB-VM-250, IB-VM-550, IB-VM-1050, IB-VM-1550, IB-VM-1850, IB-VM-2000, and Trinzic Reporting TR-2000
and TR-2000-A series appliances. You cannot upgrade to NIOS 7.3.x on these appliances. See Upgrade
Guidelines on page 16 for additional upgrade information.

 Infoblox does not recommend operating the physical Trinzic TE-820 appliance as the Grid Master
running NIOS 6.10.x or later due to memory constraints. Grid Manager (the Infoblox GUI) might appear
sluggish after an upgrade or new installation. On rare occasions, running NIOS 6.10.x or later on the
Trinzic TE-820 might result in less than optimal performance. To address this issue, you can deploy the
latest version of the Infoblox 820 virtual appliance (IB-VM-820) as the Grid Master.

 You cannot upgrade to NIOS 7.3.x if your Grid uses a physical TE-810, TE-820, or an IB-VM-810 virtual
appliance as the Grid Master or Grid Master Candidate. For the IB-VM-820 virtual Grid Master however,
you can upgrade to NIOS 7.3.x provided that the virtual appliance is currently running NIOS 6.10.x or
later. After the upgrade, ensure that you change the “Resource Allocation” for the appliance to reflect
the 4 GB of RAM; or you can download and install the latest .ovf file for the IB-VM-820 to enable the 4
GB of RAM.

 Infoblox Reporting and Analytics: There are some significant changes in the functionality and user
interface for the Infoblox Reporting solution. Infoblox recommends that you take some time to explore
and navigate through the new user interface to get familiar with the new features and terminologies. If
you are upgrading to NIOS 7.3.x from a previous NIOS release, your custom reports will be affected and
you may need to take some actions to re-create them. For more information about these changes, see
Changes to Default Behavior on page 11.

Supported Platforms

Infoblox NIOS 7.3.x is supported on the following platforms:


 NIOS Appliances
- Infoblox Advanced Appliances: PT-1400, PT-2200, PT-4000, and PT-4000-10GE
- Network Insight Appliances: ND-800, ND-1400, ND-2200, and ND-4000
- Trinzic Appliances: TE-100, TE-810, TE-820, TE-1410, TE-1420, TE-2210, TE-2220, Infoblox-4010, and
Infoblox-4020
- All Trinzic Rev-1 and Rev-2 appliances (For more information about Trinzic Rev-2 appliances, refer to
KB article 17748, available on the Infoblox Support web site at https://support.infoblox.com.)
- Cloud Network Automation: CP-V800, CP-V1400, and CP-V2200
- Trinzic Reporting: TR-800, TR-1400, TR-2200, and TR-4000
- DNS Cache Acceleration Appliances: IB-4030 and IB-4030-10GE

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 2 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

 vNIOS for VMware on ESX/ESXi Servers


The Infoblox vNIOS on VMware software can run on ESX or ESXi servers that have DAS (Direct Attached
Storage), or iSCSI (Internet Small Computer System Interface) or FC (Fibre Channel) SAN (Storage Area
Network) attached. You can install the vNIOS software package on a host with VMware ESX or ESXi 6.x.x,
5.5.x, 5.1.x, or 5.0.x installed, and then configure it as a virtual appliance.

vSphere vMotion is also supported. You can migrate vNIOS virtual appliances from one ESX or ESXi server to
another without any service outages. The migration preserves the hardware IDs and licenses of the vNIOS
virtual appliances. VMware Tools is automatically installed for each vNIOS virtual appliance. Infoblox
supports the control functions in VMware Tools. For example, through the vSphere client, you can shut
down the virtual appliance.

You can deploy certain vNIOS virtual appliances with different hard disk capacity. Some vNIOS appliances
are not supported as Grid Masters or Grid Master Candidates. Note that the IB-VM-800 and IB-VM-1400
virtual appliances are designed for reporting purposes. For more information about vNIOS on VMware, refer
to the Infoblox Installation Guide for vNIOS Software on VMware. For information about vNIOS virtual
appliances for reporting, refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances.

 vNIOS for Microsoft Server 2008 R2, 2012, and 2012 R2 Hyper-V
The Infoblox vNIOS virtual appliance is now available for Windows Server 2008 R2 and Windows Server 2012
and 2012 R2 that have DAS (Direct Attached Storage). Administrators can install vNIOS virtual appliance on
Microsoft Windows® servers using either Hyper-V Manager or SCVMM. A Microsoft Powerscript is available
for ease of installation and configuration of the virtual appliance. Note that vNIOS for Hyper-V is not
recommended as a Grid Master or Grid Master Candidate. With this release, you can deploy certain vNIOS
appliances with a 50 GB, 55 GB, or 160 GB hard disk. You can also deploy the IB-VM-800 and IB-VM-1400
virtual appliances as reporting servers. For more information about vNIOS for Hyper-V, refer to the Infoblox
Installation Guide for vNIOS on Microsoft Hyper-V.
Note: All virtual appliances for reporting purposes are supported only for Windows Server 2012 R2.

 vNIOS for Xen Hypervisor


The Infoblox vNIOS for Xen is a virtual appliance designed for Citrix XenServer 6.1 and 6.2 running Xen
hypervisor and for Linux machines running Xenproject.org 4.3 hypervisor. You can deploy vNIOS for Xen
virtual appliances as the Grid Master, Grid members, or reporting servers depending on the supported
models. Note that the IB-VM-800 virtual appliances are designed for reporting purposes only. For more
information about vNIOS for Xen, refer to the Infoblox Installation Guide for vNIOS for Xen Hypervisor. For
information about vNIOS virtual appliances for reporting, refer to the Infoblox Installation Guide for vNIOS
Reporting Virtual Appliances.

 vNIOS for KVM Hypervisor


The Infoblox vNIOS for KVM is a virtual appliance designed for KVM (Kernel-based Virtual Machine)
hypervisor and KVM-based OpenStack deployments. The Infoblox vNIOS for KVM functions as a hardware
virtual machine guest on the Linux system. It provides core network services and a framework for
integrating all components of the modular Infoblox solution. You can configure some of the supported
vNIOS for KVM appliances as independent or HA (high availability) Grid Masters, Grid Master Candidates,
and Grid members. For information about vNIOS for KVM hypervisor, refer to the Infoblox Installation
Guide for vNIOS for KVM Hypervisor and KVM-based OpenStack.

 vNIOS for AWS (Amazon Web Services)


The Infoblox vNIOS for AWS is a virtual Infoblox appliance designed for operation as an AMI (Amazon
Machine Instance) in Amazon VPCs (Virtual Private Clouds). You can deploy large, robust, manageable and
cost effective Infoblox Grids in your AWS cloud, or extend your existing private Infoblox NIOS Grid to your
virtual private cloud resources in AWS. You can use vNIOS for AWS virtual appliances to provide enterprise-
grade DNS and IPAM services across your AWS VPCs. Instead of manually provisioning IP addresses and DNS

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 3 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

name spaces for network devices and interfaces, an Infoblox vNIOS for AWS instance can act as a
standalone Grid appliance to provide DNS services in your Amazon VPC, as a virtual cloud Grid member tied
to an on-premises (non-Cloud) NIOS Grid, or as a Grid Master synchronizing with other AWS-hosted vNIOS
Grid members in your Amazon VPC; and across VPCs or Availability Zones in different Amazon Regions. For
more information about vNIOS for AWS, refer to the Infoblox Installation Guide for vNIOS for AWS.

The following table shows available vNIOS virtual appliances and their specifications:

Trinzic Series Overall # of Memory Virtual vNIOS vNIOS vNIOS vNIO vNIOS Supported
Virtual Disk (GB) CPU Allocation CPU Core for for MS for S for for as Grid
Appliances Core Frequency VMware Hyper-V Xen KVM AWS Master and
s Limit Grid
Master
Candidate
IB-VM-100 55 1 1 GB 1300 MHz      No

IB-VM-800 300 2 Range: 2 – 8 3000 MHZ 3   1  No


(for reporting (Primary & GB  
only; 1 GB Reporting) Default: 8 GB
daily limit)

IB-VM-800 300 2 Range: 4 – 8 3000 MHZ 3     No


(for reporting (Primary & GB 
only; 2 GB Reporting) Default: 8 GB
daily limit)

IB-VM-810 55 2 2 GB 2000 MHz      No

IB-VM-810 160 2 2 GB 2000 MHz      No

IB-VM-820 55 2 4 GB 3000 MHz      Yes2

IB-VM-820 160 2 4 GB 3000 MHz      Yes2

IB-VM-1400 555 4 Default: 8 GB 8000 MHz 3     No


(for reporting (Primary & 
only; 5 GB Reporting)
daily limit)

IB-VM-1410 55 4 8 GB 6000 MHz      No

IB-VM-1410 160 4 8 GB 6000 MHz      Yes2

IB-VM-1420 160 4 8 GB 8000 MHz      Yes2

IB-VM-2210 160 4 12 GB 12000 MHz      Yes2

IB-VM-2220 160 4 12 GB 12000 MHz      Yes2

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 4 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Network Overall # of Memory Virtual vNIOS vNIOS vNIOS vNIO vNIOS Supported
Insight Virtual Disk (GB) CPU Allocation CPU Core for for MS for S for for as Grid
Appliances Cores Frequency VMware Hyper-V Xen KVM AWS Master and
Limit Grid
Master
Candidate

ND-V800 160 2 8 GB 3000 MHz 3     No

ND-V1400 160 4 16 GB 8000 MHz 3     No

ND-V2200 160 8 24 GB 24000 MHz 3     No

Cloud Overall # of Memory Virtual vNIOS vNIOS vNIOS vNIO vNIOS Supported
Platform Disk (GB) CPU Allocation CPU Core for for MS for S for for as Grid
Virtual Cores Frequency VMware Hyper-V Xen KVM AWS Master and
Appliances Limit Grid
Master
Candidate

CP-V800 160 2 2 GB 2000 MHz      No

CP-V1400 160 4 8 GB 6000 MHz      No

CP-V2200 160 4 12 GB 12000 MHz      No

NOTES:
1
For KVM hypervisor only. Not supported for KVM-based OpenStack. Does not support Elastic Scaling.
2
vNIOS virtual appliance for Hyper-V is not recommended as a Grid Master or Grid Master Candidate. The
Identity Mapping feature is not supported on the IB-VM-810 and IB-VM-820 appliances. When configuring
IB-VM 820 as the Grid Master, ensure that you upgrade the memory allocation to 4 GB.
3
Does not support Elastic Scaling.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 5 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

vNIOS for VMware on Cisco UCS Express/SRE-V


The Infoblox vNIOS for VMware software can run on Cisco SRE-V (Services Ready Engine Virtualization),
which is part of the Cisco UCS (Unified Computing System) Express. Infoblox has certified running vNIOS for
VMware on Cisco SRE-V 2.0 (for ESXi 5.0 and ESXi 6.0). Cisco SRE-V enables the VMware vSphere Hypervisor
to be provisioned on Cisco SRE 700/710 and 900/910 Service Modules. The Cisco SRE Service Module can
reside on Cisco 2900 and 3900 series ISRs G2.

The following table lists the supported vNIOS for VMware virtual appliances on SRE 700/710 and SRE
900/910:

vNIOS on VMware Disk (GB) # of CPU Memory Virtual CPU Cisco SRE Cisco SRE
Virtual Appliances Cores Allocation Core 700/710 900/910
Frequency

IB-VM-100 55 1 2 GB 2000 MHz Yes Yes


IB-VM-810 55 2 2 GB 2000 MHz Yes Yes
IB-VM-810 160 2 2 GB 2000 MHz Yes Yes
IB-VM-820 55 2 2 GB 3000 MHz Yes Yes
IB-VM-820 160 2 2 GB 3000 MHz Yes Yes

Note that all vNIOS for VMware virtual appliances running on Cisco SRE-V are not recommended as Grid
Masters or Grid Master Candidates. The IB-BOB virtual appliance has been renamed to IB-VM-100. For new
installation, use the 55 GB software image. IB-VM-100 only supports configuration as a Grid member.

 vNIOS for Riverbed® Steelhead Appliances


Infoblox has certified the vNIOS for Riverbed software with the following Riverbed Steelhead models and
software versions:

Riverbed Models Supported EX and RiOS versions


EX 1.0 with RiOS 7.0.x
EX560, EX760, EX1160, EX1260 EX 2.5 with RiOS 8.0.x
EX 3.1 with RiOS 8.5.x

The vNIOS for Riverbed virtual appliance can only operate as an independent Grid member. For additional
information, refer to the Infoblox Installation Guide for vNIOS Software for Riverbed Steelhead Platforms.

NOTE: You can upgrade a Grid with supported Riverbed virtual members to NIOS 7.x. Ensure that the
Riverbed model has 64 bit support.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 6 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NEW FEATURES

This section lists new features in the 7.3.0 release.

NIOS 7.3.0

Amazon Route 53 Integration


Infoblox DDI for AWS integrates the AWS Route 53 DNS service, providing a unified DNS view across AWS and
hybrid cloud deployments through a centralized console that improves visibility and performance. Without
Infoblox, AWS deployments utilizing Route 53 have limitations with private hosted zones, which restrict DNS
resolution from outside AWS and hinder hybrid cloud deployments.

Enhancements for Cloud Network Automation


This NIOS release adds the following enhancements for Cloud Network Automation:
 Delegated objects: You can now add, modify, and delete fixed addresses and reservations in delegated
networks and address ranges through the Grid Manager UI in addition to using cloud API calls.
 vDiscovery: vDiscovery now automatically removes unmanaged and discovered data for VMs that have
been deleted in vSphere, OpenStack, and/or AWS EC2. Clear all discovered data; remove discovered
data from vDiscovery tasks; perform vDiscovery jobs directly in the Cloud tab.
 Visibility: A new report and dashboard widget to show dynamic license utilization has been added.

Infoblox Reporting and Analytics


Infoblox Reporting and Analytics delivers an enhanced reporting interface so you can now create custom
dashboards, reports, and alerts. You can continue to use the traditional NIOS reports in the new interface and
customize them to meet your specific requirements, or you can create new custom dashboards and reports
from the ground up using a powerful search and visualization language or a simple graphical interface.

Cisco ISE Integration


Infoblox integration with Cisco pxGrid (Cisco Platform Exchange Grid) enables Network Insight and Cisco ISE
(Cisco Identity Services Engine) to exchange valuable networking, user, device, and security-event information,
enriching both Infoblox DDI and ISE data. The pxGrid publish/subscribe architecture enables users to combine
pxGrid ecosystem products into a unified solution that enhances security-response accuracy and timeliness;
expands visibility of networks, users, and devices; and improves overall IT operations by sharing information
between network and security teams. Infoblox participation in the pxGrid community makes Infoblox data
indispensable for Cisco ISE customers.

STIX/TAXII Support
This release adds the TAXII (Trusted Automated eXchange of Indicator Information) service that enables NIOS to
integrate with other security software using the TAXII/STIX protocol for cyber threat mitigation. In this release,
the TAXII server is able to receive a mitigation request from a STIX/TAXII enabled third-party security platform
that adds to the DNS Firewall (RPZ) an IP address or domain that is deemed malicious. This enables the third-
party security platform to use the Infoblox Grid to apply a distributed mitigation policy.

Infoblox DNS Threat Analytics


DNS Threat Analytics mitigates DNS data exfiltration by employing analytics algorithms to detect DNS tunneling
traffic. When you enable the analytics service, NIOS starts analyzing incoming DNS data and applying
algorithms to detect security threats. Once threats are detected, NIOS blacklists the domains and transfers
them to the designated mitigation RPZ (Response Policy Zone), and traffic from offending domains is blocked.
DNS Threat Analytics also includes a whitelist that contains trusted domains on which NIOS allows DNS traffic.
These are known good domains that carry legitimate DNS tunneling traffic for tools such as Avast, Sophos,
McAfee, Boingo, Barracuda, and others. The whitelist is extensible so new whitelisted domains can be added
and rolled out accordingly. This release provides automatic updates for Threat Analytics modules through Grid
© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 7 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Manager. When you configure automatic updates for Threat Analytics modules, NIOS automatically download
the module set periodically. You can also view the current whitelist version and module set version in the
Updates tab in the Grid Threat Analytics Properties editor.
NOTE: Infoblox highly recommends that you run the analytics service for a limited time to monitor and preview
what has been detected before actually blocking any domains. To do so, set Policy Override to Log Only
(Disabled) when you create the designated local RPZ. You can carefully review the list of detected domains
and decide which domains you want to continue blocking and which domains you want to add to the analytics
whitelist. You should review the blacklisted domains on a regular basis to make sure that no legitimate use of
DNS tunneling is blocked. You can update the analytics whitelist by adding new custom whitelisted domains,
moving legitimate domains from the blacklisted domain list, or using CVS import and export. Due to memory
and capacity required to perform analytics, ensure that you install the Threat Analytics and RPZ licenses and
enable the threat analytics service on an appliance that has big enough capacity. Following are the supported
Infoblox appliance models on which you can run the threat analytics service: IB-4010, IB-4030, IB-4030-10GE,
TE-2210, TE-2220, PT-2200, PT-4000, PT-4000-10GE, IB-VM-2220, and IB-VM-4010.

VRF Integration for Network Insight


Through Infoblox Network Insight, the NIOS appliance is now able to discover network devices that are
configured or deployed within virtual networks, such as VRF-based (Virtual Routing and Forwarding) networks.
You now have visibility of your complete virtual network infrastructure, which allows you to view and manage
overlapping IP addresses, VRF-specific data from VRF-enabled devices, and discovered end host data.

Security Visibility (RFE-5732)


Grid Manage now provides the following features to increase visibility of your Infoblox security infrastructure:
 A comprehensive Security dashboard that displays the current security data, including Threat
Protection events and RPZ hits. You can view information such as the top N Grid members by events,
top N rules by volume, and more. To ensure that the Security dashboard displays correct data, use NTP
to synchronize the time of the Grid members with that of the Grid Master.
 Threat Protection widgets that display security data based on the new “grouping” feature.
 New reports that display security information related to Infoblox External DNS Security and Infoblox
Internal DNS Security.

Infoblox Security Infrastructure Enhancements (RFEs: 5635, 5267, 5641, 5670, 5607, 5369, 4974, 5595,
6172, and 5712)
This release adds a few enhancements to the Infoblox Security Infrastructure features, as follows:
 Ability to reset the appliance to use the default Threat Protection ruleset.
 Specify the interface for downloading the latest ruleset.
 Configure the MGMT port as the interface for Reporting traffic.
 Display FQDN information for Threat Protection rule match the syslog.
 Display the current active ruleset version in Grid Manager

Data Collection Virtual Appliances


Infoblox introduces phase one of the Data Collection feature in this release. You can set up a newly developed
Data Collection appliance as the data collector to work with the Infoblox Reporting member for report
generation. The purpose is to enhance the collector in a future release to enable scalable distribution of Grid
data to the Reporting server and other third-party destinations.

DNS Record Scavenging


The DNS record scavenging feature allows you to remove stale DNS resource records from zone data to prevent
the accumulation of invalid records. A scavenging operation determines, based on predefined rules, which
records became stale, i.e. reclaimable, and removes them.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 8 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Secure Dynamic DNS Updates


The secure DDNS updates feature provides the following mechanisms to restrict DDNS updates:
 Protecting specific resource records so that clients cannot update them.
 For authenticated updates, tracking the Kerberos GSS-TSIG principal that created a record and
preventing DDNS updates to the record created by a different GSS-TSIG principal.
 Defining FQDN patterns for domain names that prevent DDNS updates to matching FQDNs.
To handle principal authentication-based secure updates even more flexibly, you can create dynamic update
groups.

Elastic Scaling for vNIOS for KVM and vNIOS for VMware Appliances
This release adds Elastic Scaling support for the following vNIOS virtual appliances: vNIOS for KVM and vNIOS for
VMware. You can now provision and deploy Trinzic virtual appliances for these hypervisors as the Grid Master or
Grid members using Elastic Scaling. For information about supported vNIOS models, see the table on page 4.

Improved Support for vNIOS for KVM on OpenStack


Issues with deploying vNIOS for KVM on certain OpenStack distributions (e.g., Red Hat Enterprise Linux
OpenStack Platform 6) have been resolved. Property injection through cloud-init and ability to assign IP
addresses and network properties via OpenStack DHCP for vNIOS for KVM network interfaces is now supported.
Qcow2 images are now available in addition to OVA images.

Auto-creation of DNS Records for Discovered VMs


When you configure a vDiscovery job, you can now enable the appliance to automatically create or update Host
records or A/AAAA or PTR records for discovered VM instances in authoritative zones. You can also enter a
formula that NIOS uses to create the DNS names for the discovered IP addresses based on their VM parameters
such as vm_name or discovered_name. By doing so, NIOS is able to automatically create and update DNS
records for private and public IPs discovered through vDiscovery.

Support for HTTP or HTTPS Proxy Servers


NIOS now supports the configuration of HTTP or HTTPS proxy servers for automatic updates. You can use this
feature to download automatic updates for Threat Protection rulesets and Threat analytics bundles. For an
AWS cloud deployment, you can configure a proxy server for vDiscovery or use it as the AWS API Proxy.

Enhancements for DNS Traffic Control (RFE-3315)


By adding support for the NAPTR record type to the DTC (DNS Traffic Control) solution, DTC is now in compliant
with the 3GPP standards. You can also add an SNMP health monitor to track server availability and define the
load balancing method for a DTC LBDN (Load Balancing Domain Name) record. DTC now responds to queries
containing the EDNS0 (Extension Mechanisms for DNS) Client Subnet option by leveraging that address
information in performing geographic load balancing.

Support for match-recursive-only BIND option (RFE-469)


You can now enable the match-recursive-only option for the DNS view. When you enable this option, only
recursive queries from matching clients match the selected DNS view. This option can be used in conjunction
with the match client list and match destination list.

Replication of syslog Rotated Files to External Servers (RFE-354/599)


You can configure the appliance to back up rotated syslog files to external servers through FTP or SCP. When
you do so, the appliance forwards the rotated syslog files to the external servers that you configure.
Configuring syslog external backup servers helps you conveniently send (archive) syslog files to different
destinations by their logging categories. This allows you to split syslog files based on the service and efficiently
perform troubleshooting.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 9 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Shared Record Support for CNAMES (RFE-498)


This release adds support for CNAME records to shared record groups.

NIOS Audit Log Reporting (RFE-3777)


The newly added Audit Log Events report provides information about the administrator-initiated events,
including login events, logout events, service restarts, appliance reboots, and write operations such as the
addition, modification, and deletion of objects.

Support for ‘posixGroup’ in LDAP Authentication (RFE-3805)


This release enhances LDAP authentication to include the support for group attributes and allow groups from
the ‘posixGroup’ object class.

Enabling Active Directory Authentication for Nested Groups (RFE-507)


Windows servers support nesting groups in which you can add a group of admin users as a member of another
group. Nested groups consolidate admin accounts and help reduce the number of permissions required for
individual users or groups. In NIOS, you can now enable nested group query so the appliance can recursively
look up and use AD authentication service to authenticate members or admin accounts that are part of a
nested group.

Remote Authentication for Local Groups (RFE-910)


Depending on where admin user credentials are stored, you can configure the NIOS appliance to authenticate
admins locally or remotely. When you configure the authentication type as "local," NIOS authenticates admins
against its local database. When you configure the authentication type as "remote," NIOS authenticates admins
whose user credentials are stored remotely on authentication servers, such as RADIUS servers, AD domain
controllers, LDAP servers, or TACACS+ servers.

Hostname and server-id Options (RFE-1661)


When you configure DNS anycast, more than one DNS name servers share a single IP address. To identify which
DNS name server is answering queries, you can configure the hostname and server ID options so the NIOS
appliance returns the hostname of the DNS name server that is currently answering queries.

Controlling NS Records for AD-replicated Zones (RFE-6268)


When you have assigned a Microsoft server as the primary server for a DNS zone and if the zone is AD-
integrated (Active Directory), you can now configure a list of domain controllers that are allowed to add NS
records to the zone.

DHCP Lease Scavenging (RFE-4594)


This release supports DHCPv6 lease scavenging.

DHCP Failover Recovery (RFE-5142)


You can now perform a DHCP recovery for failover associations through Grid Manager. As result of the recovery,
all conflicts are resolved on the passive node after a restart.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 10 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

CHANGES TO DEFAULT BEHAVIOR

This section lists changes to default behavior in NIOS 7.x releases.

NIOS 7.3.0 Release

 The Infoblox Reporting and Analytics solution delivers an enhanced interface through Grid Manager.
Starting with this release, you will experience the following when using the Reporting solution:

 Product Terminology: Reports and Searches in previous releases are now called dashboards and
Reports respectively in the new user interface.
 Object Management: NIOS no longer manages reporting objects such as searches, alerts, reports,
and smart folders. You will not be able to perform operations such as global search, quick filtering,
bookmarking, and others for these objects. You can now manage these objects through the new
user interface.
 Permissions: Permissions for all reporting objects are migrated to the new Reporting and Analytics
solution and managed through the new user interface after an upgrade. You may see the new built-
in role, Everyone, when configuring Reporting permissions. For best practices, do not alter
permissions for this new built-in role. Note that the Reporting Dashboard and Reporting Search
global permissions have been removed. If an admin group or admin role was granted these
permissions before an upgrade, the permissions will still be displayed after an upgrade. However,
they won’t take any effect. The Grid Reporting Properties permission is retained. In addition,
reporting object permissions for dashboards and searches (including global dashboards and
searches) are migrated. These object permissions are retained for applicable migrated users. If
permissions were granted to a specific admin group for a dashboard or search before an upgrade,
only these admin users and superusers have permissions to access the migrated dashboard and
report after an upgrade. If a limited-access user group is created through the new interface after
the upgrade, users in this admin group will not be able to access the dashboard and report even if
they are granted access to the Infoblox Reporting and Analytics App. Superusers must explicitly
grant permissions to this limited-access admin group for users in this group to access the dashboard
and report.
 Navigation and Visualization: Navigations for some reporting functions, such as searches, alerts,
email and page settings, and email PDF delivery, have changed. You can navigate through the new
user interface to get familiar with the changes in this release. In addition, all pre-defined reports
might look different than the traditional ones depending on your filtering configuration.
 Extensible Attributes: There are some NIOS reports that support filtering by multiple extensible
attributes. These reports are migrated into dashboards in which the new user interface supports
filtering and grouping only by the extensible attribute Site. If you want to filter a report by
multiple extensible attributes, you must clone the dashboards, add filter inputs, and then modify
the view XML to support extensible attributes.
 Searches and Reports: Only NIOS system and global reports and searches are migrated to the new
dashboards and reports respectively after an upgrade. All user private reports are not migrated. If
you want to keep the settings for the user private dashboards and reports, you can do one of the
following:
1. Create global reports using the same private settings before an upgrade so the reports can
be migrated and the same private settings are retained.
2. Clone the corresponding system or global dashboards and reports after an upgrade, and
then reconfigure them using the original private settings such as filters and scheduling
through the new user interface.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 11 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

For detailed information about these changes in the Reporting and Analytics solution, refer to the
Infoblox NIOS Administrator Guide and the Splunk documentation.
 vDiscovery now automatically removes unmanaged and discovered data for VMs that have been deleted
in vSphere, OpenStack, and/or AWS EC2.
 The RIR Organizations tab under the Administration tab of Grid Manager has been changed to RIR. No
functionality is affected; only the name of the tab is changed.
 In this release, the “RIPE Changed” extensible attribute definition for networks, network containers,
and network template has been removed because RIPE has removed the “Changed” field in their
database. During an upgrade to NIOS 7.3.x, the value for this extensible attribute will be removed if it
exists in any networks and network containers.

NIOS 7.2.x Releases

 Starting with NIOS 7.2.3, you can add up to 200 sort lists (instead of 50) on the IB-4030 appliance.

 In previous releases, when you used DNAME in your configuration, querying a DNS zone returned the A
record. In NIOS 7.2.x when DNAME configuration is in effect, querying a DNS zone no long returns the A
record, instead it follows the DNAME redirection.

 The following CLI commands have been deprecated: set holddown, set fetches_per_server,
set fetches_per_zone, and set recursion_query_timeout. You can now use configurable
parameters to mitigate bogus domain attacks through Grid Manager.

 In this release, the former VM Discovery is now called vDiscovery and has been extended to support
discovery of VMs and networks in OpenStack and AWS EC2 environments. vDiscovery uses SSL certificate
validation for all discovery connections.
NOTE: When discovering VMware endpoint servers, ensure that you upload a self-signed certificate to
the Infoblox certification database. Otherwise, VMware connections might fail.

 In this release, the OID numbers for the following have been changed respectively:
ibCPU1Temperature 1.3.6.1.4.1.7779.3.1.1.2.1.2.0
ibCPU2Temperature 1.3.6.1.4.1.7779.3.1.1.2.1.3.0
to
ibCPU1Temperature 1.3.6.1.4.1.7779.3.1.1.2.1.17.0
ibCPU2Temperature 1.3.6.1.4.1.7779.3.1.1.2.1.18.0

 CSRs (Certificate Signing Requests) and self-signed certificates now have new defaults. They are
defaulted to SHA-256 algorithm with 2048 key size instead of SHA-1 with 2048 key size.
 Infoblox DNS Firewall: RPZ (Response Policy Zone) no longer recurses for domains that are already in
the RPZ feed.

NIOS 7.1.x Releases

 In previous releases, a forward-mapping zone defined using the wildcard character asterisk (*) was used
for forwarding to a proxy DNS server for records that did not fall under the main authoritative zone.
Queries that contain these records were forwarded to the proxy server for responses. Starting with this
release, this configuration is invalid.
 Infoblox Advanced DNS Protection: For threat protection rules that contain the Packets per second
parameter, a new parameter Rate algorithm is added. The default for Rate algorithm is set to “rate-

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 12 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

limiting,” which provides a rate-limiting behavior that allows some traffic to go through before the rest
of the traffic is dropped for each drop interval. In previous releases however, these rules adopted the
“blocking” behavior in which the appliance allows client traffic to go through until it hits the rate
limit. It then blocks all traffic for the duration of the drop interval. If client traffic continuously
exceeds the rate limit, the appliance continues to block all traffic for subsequent drop intervals
without letting through any traffic, which could result in an indefinite traffic blockage. You can change
the parameter from “rate-limiting” to “blocking” for any affected rules after an upgrade.
 For CSV Import, the “use_known_clients” and “use_unknown_clients” fields have been deprecated and
merged into the “known_clients_option” and “unknown_clients_option” fields respectively.

 In previous releases, when client traffic triggered DNS tunneling rules, all traffic from the offending
client was blocked. Starting with this release, only DNS tunneling response traffic that matches the
configured DNS packet size is blocked when these rules are triggered. All other traffic is processed by
subsequent threat protection rules.
 In previous releases, there was no limit to the number of RPZs (Response Policy Zones) you could
configure. Starting with NIOS 7.1.0, you can add up to a total of 32 RPZs, including local and FireEye
integrated RPZs. The appliance returns an error when you try to add more than 32 RPZs. If you have
more than 32 RPZs configured in a previous NIOS release, the appliance returns an error in the Upgrade
Test when you upgrade to NIOS 7.1.0 and later.
 In previous releases, RPZ query name recursion was enabled by default. The DNS recursive name server
performed RPZ recursive lookups for the fully qualified domain name that was part of an RPZ. Starting
with NIOS 7.1.0, RPZ query name recursion is disabled by default for all new installations and upgrades.
When RPZ query name recursion is disabled, the DNS recursive name server sends responses for the
domains being queried, without forwarding queries to the authoritative name servers. This can speed
up recursive RPZ lookups by eliminating unnecessary recursions for domains that are known to be
malicious, possibly caused by internal DDoS attacks on the recursive server.
NOTE: Queries to domain names that end with “rpz-xxx” (where xxx can be one of the following: ip,
client-ip, nsdname, or nsip) might hit an RPZ rule before recursion is complete even when the queries
do not match any CLIENT-IP or QNAME rules.

NIOS 7.0.x Releases

 Starting with NIOS 7.0.0, you must have IPv6 addresses for both nodes in an HA pair if one of them has
an IPv6 address. This was optional in previous releases.
 In previous releases when you apply a non-global DHCP option filter to a DHCP range, the appliance
may return option 43 in the response. Starting with 7.0.0, the appliance does not return option 43 in
any responses when you apply a non-global DHCP option filter to a range.

CHANGES TO Infoblox API and RESTful API (WAPI)

This section lists changes made to the Infoblox API and RESTful API in NIOS releases. For detailed information
about the supported methods and objects, refer to the latest versions of the Infoblox API Documentation and
the Infoblox WAPI Documentation, available through the NIOS products and on the Infoblox Support web site.

The latest available WAPI version is 2.3.

This NIOS release supports the following WAPI versions: 1.0, 1.1, 1.2, 1.2.1, 1.3, 1.4, 1.4.1, 1.4.2, 1.5, 1.6,
1.6.1, 1.7, 1.7.1, 1.7.2, 1.7.3, 1.7.4, 2.0, 2.1, 2.1.1, 2.2, 2.2.1, 2.2.2, and 2.3.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 13 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

WAPI Deprecation and Backward Compatibility Policy

This policy covers the interfaces exposed by the Infoblox WAPI and the protocol used to communicate with it.

Unless explicitly stated in the release notes, previously available WAPI versions are intended to remain
accessible and operative with later versions.

The planned deprecation of a given version of the WAPI will normally be announced in the release notes at
least one year in advance. Upon deprecation, the announced WAPI version and all prior versions will no longer
be supported in subsequent releases. For example, if the current WAPI release is v3.4 and the release notes
contain an announcement of the v1.5 deprecation, v1.4 and v1.5 API requests would continue to work with
later releases for one year from the announcement date. After that, some or all requests for these deprecated
versions may not work with versions later than v1.5. API requests adherent to versions later than v1.5 (v2.0 for
example) would continue to work with subsequent releases. Infoblox seeks to avoid any deprecation that has
not been announced in advance, however product modifications and enhancements may affect specific API
requests without a prior announcement; Infoblox does not warrant that all API requests will be unaffected by
future releases. This policy applies to both major and minor versions of the WAPI. Infoblox reserves the right
to change this policy.

NIOS 7.3.x Release

WAPI new objects:


 adminrole : Admin Role object.
 allendpoints : All Endpoints object.
 allrecords : AllRecords object.
 allrpzrecords : DNS All RPZ Records object.
 awsrte53taskgroup : AWS Route53 task group object.
 awsuser : AWS User object.
 bulkhost : Bulkhost object.
 cacertificate : CA Certificate object.
 captiveportal : Captive portal object.
 ciscoise:endpoint : Cisco ISE Endpoint object.
 ciscoise:notificationrule : Cisco ISE notification rule object.
 ddns:principalcluster : DDNS Principal Cluster object.
 ddns:principalcluster:group : DDNS Principal Cluster Group object.
 dhcpfailover : DHCP Failover Association object.
 discoverytask : Discovery Task object.
 dtc:allrecords : DTC AllRecords object.
 dtc:monitor:snmp : DTC SNMP monitor object.
 dtc:record:naptr : DTC NAPTR Record object.
 filterfingerprint : DHCP Fingerprint Filter object.
 filtermac : DHCP MAC Address Filter object.
 filternac : DHCP NAC Filter object.
 filteroption : DHCP filter option object.
 fingerprint : DHCP Fingerprint object.
 grid:dashboard : Grid Dashboard object.
 ipam:statistics : IPAM statistics object.
 member:threatprotection : Member threat protection object.
 network_discovery : Network discovery object.
 orderedresponsepolicyzones : Ordered Response Policy Zones object.
 record:rpz:a : Response Policy Zone Substitute A Record Rule object.
 record:rpz:a:ipaddress : Response Policy Zone Substitute IPv4 Address Rule object.
© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 14 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

 record:rpz:aaaa : Response Policy Zone Substitute AAAA Record Rule object.


 record:rpz:aaaa:ipaddress : Response Policy Zone Substitute IPv6 Address Rule object.
 record:rpz:cname : DNS Response Policy Zone CNAME record object.
 record:rpz:cname:clientipaddress : DNS RPZ CNAMEClientIpAddress record object.
 record:rpz:cname:clientipaddressdn : Substitute Domain Name Based on Client IP Address rule object.
 record:rpz:cname:ipaddress : DNS RPZ CNAMEIpAddress record object.
 record:rpz:cname:ipaddressdn : Substitute Domain Name Based on IP Address rule object.
 record:rpz:mx : Response Policy Zone Substitute MX Record Rule object.
 record:rpz:naptr : Response Policy Zone Substitute NAPTR Record Rule object.
 record:rpz:ptr : Response Policy Zone Substitute PTR Record Rule object.
 record:rpz:srv : Response Policy Zone Substitute SRV Record Rule object.
 record:rpz:txt : Response Policy Zone Substitute TXT Record Rule object.
 ruleset : DNS Ruleset object.
 scavengingtask : DNS scavenging task object.
 taxii : Taxii Member object.
 threatprotection:rule : Member Threat Protection Rule object.
 userprofile : User profile object.
 vdiscoverytask : Discovery task object.
 zone_rp : DNS Response Policy Zone object.

WAPI objects with changed/enhanced functionality:


 view - added 'match-recursive-only' option.
 discovery data structure - extended with new attributes.
 member:dhcpproperties - added the enable_dhcp field.
 member:dns - added the enable_dns field.
 member - create, update, and delete enabled for this object. Added support of new fields and
functions, most of the existing fields made read-write.
 extensibleattributedef – create, update, and delete enabled for this object. Added support of new
fields. Most of the existing fields were also made read-write.
 networkcontainer/ipv6networkcontainer - added support for DHCP options.
 Search - added support for targeted searches by DNS name, DUID, IP address, or MAC address.

Supported Perl and Dependency Versions for the Infoblox API


Perl Crypt::SSLeay LWP::UserAgent XML::Parser Net::INET6Glue
OS
Version Version Version Version Version
5.22.0
Microsoft Windows 8.1® 0.72 6.13 2.44 0.603
5.12.3

Microsoft Windows 8® 5.22.0 0.72 6.13 2.44 0.603

5.22.0
Microsoft Windows 7® 0.72 6.13 2.44 0.603
5.20.2
Red Hat® Enterprise Linux®
5.16.3 0.72 6.13 2.44 0.603
7.1
Fedora core 2.6.25.6-
5.12.3 0.72 6.13 2.44 0.603
45.fc14.i686
Ubuntu x86_64 GNU/Linux 5.18.2 0.72 6.13 2.44 0.603

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 15 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Apple® Mac OS X 10.10.3 5.18.2 0.72 6.13 2.44 0.603


5.22.0
Apple® Mac OS X 10.9.5 0.72 6.13 2.44 0.603
5.16.2

NIOS 7.0.x Releases


 When executing a RESTful API request from version 2.0 and later, the XML data format has been
updated to accommodate tag names (used primarily in extensible attributes) that contain spaces and/or
invalid XML characters.

UPGRADE GUIDELINES

Upgrading to NIOS 7.3.x

 You cannot upgrade to NIOS 7.3.x if your Grid uses a physical TE-810, TE-820, or the IB-VM-810 virtual
appliance as the Grid Master or Grid Master Candidate. For more information, see INTRODUCTION on
page 1.

 Depending on your appliance model, the distribution step of the upgrade process may take longer than
usual due to improvement made to the swap file space.

 Infoblox Reporting and Analytics delivers an enhanced reporting interface so you can continue to create
custom dashboards, reports, and alerts. When you upgrade from a previous NIOS release, some of the
reporting functions and terminologies might have changed. In addition, your custom reports might be
affected. For information about the changes and new features, see Changes to Default Behavior on
page 11 and refer to the Infoblox NIOS Administration Guide and the Splunk documentation.

 DNS Scavenging: Note the following changes to the last query settings for zones and RRs during an
upgrade to 7.3.x:
 There are no limitation for monitored zones and the lists are no longer available in the Grid and
Member Reporting Properties editors.
 For every monitored zone: The reclamation settings are set to the “overridden” state at the zone
level; and the “Enable zone last queried monitoring,” “Enable RRs last queried monitoring” or both
is set to the Enabled state. In addition, when enabling Grid-wide scavenging, zones with last
queried monitoring enabled prior to an upgrade will not inherit reclamation settings from the Grid
and they will not be part of the Grid-wide reclamation task (either manual or recurring).
 The last queried monitoring for zones and RRs can now be enabled only at a given level (Grid, view,
or zone). Enabling monitoring for a zone does not enable monitoring for sub zones.

Upgrading to NIOS 7.2.x

 In a Multi-Grid configuration, upgrading to NIOS 7.2.0 might fail if there is a Cloud Platform member in
the sub Grid.

 You cannot upgrade to NIOS 7.x on the following appliances: IB-250-A, IB-550-A, IB-1050-A, IB-1550-A,
IB-1552-A, IB-1852-A, IB-2000, IB-2000-A, IB-VM-250, IB-VM-550, IB-VM-1050, IB-VM-1550, IB-VM-1850,
IB-VM-2000, and Trinzic Reporting TR-2000 series appliances. For information about supported
platforms, see Supported Platforms on page 1.

 If your Grid consists of RSP (Riverbed Services Platform) virtual members, upgrading to NIOS 7.x and
later will fail. For information about which Riverbed virtual members are supported, see the vNIOS on
Riverbed® Steelhead Appliances section on page 5.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 16 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

 Note the following if you have scheduling settings configured for discovery, blackout periods, port
polling and threat protection ruleset updates before an upgrade:
o The appliance does not account for non-UTC time zones and DTS (Daylight Savings Time) in your
scheduling settings after an upgrade. To avoid time shifts in your schedules, ensure that you
update all scheduling settings for these features after the upgrade.

 Scheduled full upgrades have the following restrictions:


o Add, modify, or delete DNS zones that are assigned to an NS group or member.
o Add, modify, or delete any name server groups.
o Start or stop DNS service.
o Perform service restarts from Grid Manager.

 When you upgrade to NIOS 7.2.x, RPZ query name recursion (qname-write-recurse) is disabled by
default.

 When you use vDiscovery to discover VMware endpoint servers, ensure that you upload a self-signed
certificate to the Infoblox certification database. Otherwise, VMware connections might fail.

Upgrading to NIOS 7.0.x

Note the following for IPv6 Grid support:


 If your Grid Master is configured with an IPv6 VIP, all Grid Master Candidates must also include an IPv6
VIP. For an HA pair, both nodes of the HA pair must have IPv6 addresses for the Grid Master and the
Grid Master Candidate.
 After you upgrade to NIOS 7.0.x, Infoblox recommends that you back up the configuration after you
change network connectivity to a different mode (IPv4, IPv6, or IPv4 and IPv6 dual mode). Restoring an
old backup by performing a forced restore may prevent some Grid members from rejoining the Grid
after the restore.
 IPv6-only configuration does not support the following:
 HSM
 LCD
 NAT groups
 OSPF and BGP

When you schedule a full upgrade from a previous release to NIOS 7.0.x, the following DNSSEC limitations are
applicable:
 You cannot configure new settings that are added to the authoritative zone object while the upgrade is
still in progress. This restriction is not applicable to future upgrades.
 When you upgrade, you can sign or unsign an authoritative zone only if the Grid Master Candidate and
the associated serving members are upgraded. This restriction is not applicable to future upgrades.
 An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving
members are upgraded. This restriction is not applicable to future upgrades.
 An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all
the serving members are upgraded. This restriction is not applicable to future upgrades.
 You cannot delete keys while the upgrade is still in progress.
 You cannot update DNSSEC related parameters at the member level while the upgrade is still in
progress. Example: rollover mechanism, NSEC3 salt length and iterations, and enable or disable
automatic KSK rollover.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 17 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

BEFORE YOU INSTALL

To ensure that new features and enhancements operate properly and smoothly, Infoblox recommends that you
evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS
release.

Infoblox recommends that administrators planning to perform an upgrade from a previous release create and
archive a backup of the Infoblox appliance configuration and data before upgrading. You can run an upgrade
test before performing the actual upgrade. Infoblox recommends that you run the upgrade test, so you can
resolve any potential data migration issues before the upgrade.

Following is a list of upgrade and revert paths. You can also schedule a full upgrade from these releases.

7.2.4 and earlier 7.2.x releases


7.2.202-LD and earlier 7.2.2xx releases
7.1.8 and earlier 7.1.x releases
7.0.8 and earlier 7.0.x releases
6.12.14 and earlier 6.12.x releases
6.11.12 and earlier 6.11.x releases
6.10.14 and earlier 6.10.x releases
6.10.203 and earlier 6.10.2xx releases

Technical Support
Infoblox technical support contact information:
Telephone: 1-888-463-6259 (toll-free, U.S. and Canada); +1-408-625-4200, ext. 1
E-mail: [email protected]
Web: https://support.infoblox.com
GUI Requirements
Grid Manager supports the following operating systems and browsers. You must install and enable Javascript for
Grid Manager to function properly. Grid Manager supports only SSL version 3 and TLS version 1 connections.
Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM.

Infoblox supports the following browsers for Grid Manager:

OS Browser
Microsoft Windows 8.1 and 8.0® Microsoft Internet Explorer® 11.x*, 10.x*
Mozilla Firefox 37.x, 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 41, 40, 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Microsoft Windows 7® Microsoft Internet Explorer® 11.x*, 10.x*, 9.x, and 8.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Microsoft Windows XP® (SP2+) Microsoft Internet Explorer 7.x and 8.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Red Hat® Enterprise Linux® 7.x Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Red Hat® Enterprise Linux® 6.x Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Red Hat® Enterprise Linux 5.x Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 18 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

Apple® Mac OS X 10.10.x Safari 8.x, 7.x


Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Apple® Mac OS X 10.9.x Safari 7.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Apple® Mac OS X 10.8.x Safari 6.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Apple® Mac OS X 10.7.x Safari 5.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x
Apple® Mac OS X 10.6.x Safari 5.x
Mozilla Firefox 32.x, 31.x, 25.x, 21.x, 16.x, and 10.x
Google Chrome 37.x, 36.x, 30.x, 27.x, 22.x, and 16.x

* NOTE: Grid Manager fully supports Microsoft Internet Explorer® 11.x and 10.x when you enable compatibility
view in the browser. Features in the Reporting tab may not function properly if you disable compatibility view.
In the browser, go to Tools -> Compatibility View to enable the feature.

When viewing Grid Manager, set the screen resolution of your monitor as follows:
Minimum resolution: 1280 x 768
Recommended resolution: 1280 x 1024 or better

Documentation
You can download the Infoblox NIOS Administrator Guide from the appliance. From Grid Manager, expand the
Help panel, and then click Documentation -> Admin Guide.

Training
Training information is available at http://inter.viewcentral.com/events/uploads/infoblox/login.html.

ACCESSING GRID MANAGER

Before you log in to Grid Manager, ensure that you have installed your NIOS appliance, as described in the
installation guide or user guide that shipped with your product, and configured it accordingly.
To log in to Grid Manager:
1. Open an Internet browser window and enter https://<IPv4 address or hostname of your NIOS
appliance> or https://[IPv6 address] of your NIOS appliance. The Grid Manager login page appears.
2. Enter your user name and password, and then click Login or press Enter. The default user name is
admin and password is infoblox.
3. Read the Infoblox End-User License Agreement and click I Accept to proceed. Grid Manager displays
the Dashboard, your home page in Grid Manager.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 19 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

ADDRESSED VULNERABILITIES

This section lists security vulnerabilities that were addressed in the past 12 months. For vulnerabilities that are
not listed in this section, refer to Infoblox KB #2899. For additional information about these vulnerabilities,
including their severities, please refer to the National Vulnerability Database (NVD) at http://nvd.nist.gov/.
The Infoblox Support website at https://support.infoblox.com also provides more information, including
vulnerabilities that do not affect Infoblox appliances.

CERT VULNERABILITY NOTE CVE-2015-8705


In some versions of BIND, an error could occur when data that had been received in a resource record was
formatted to text during debug logging. Depending on the BIND version in which this occurred, the error could
cause either a REQUIRE assertion failure in buffer.c or an unpredictable crash (e.g. segmentation fault or other
termination). This issue could affect both authoritative and recursive servers if they were performing debug
logging. Note that NIOS 7.1.0 through 7.1.8 and NIOS 7.2.0 through 7.2.4 were affected by this vulnerability.

CERT VULNERABILITY NOTE CVE-2015-8704


A DNS server could exit due to an INSIST failure in apl_42.c when performing certain string formatting
operations. Examples included but might not be limited to the following:
 Slaves using text-format db files could be vulnerable if receiving a malformed record in a zone transfer
from their masters.
 Masters using text-format db files could be vulnerable if they accepted a malformed record in a DDNS
update message.
 Recursive resolvers were potentially vulnerable when logging, if they were fed a deliberately
malformed record by a malicious server.
 A server which had cached a specially constructed record could encounter this condition while
performing 'rndc dumpdb'.

CERT VULNERABILITY NOTE CVE-2015-8605


A badly formed packet with an invalid IPv4 UDP length field could cause a DHCP server, client, or relay
program to terminate abnormally, causing a denial of service.

CERT VULNERABILITY NOTE CVE-2015-8000


If responses from upstream servers contained an invalid class parameter for certain record types, DNS service
might terminate with an assertion failure.

CERT VULNERABILITY NOTE CVE-2015-6564


Fixed a use-after-free bug related to PAM support that was reachable by attackers who could compromise the
pre-authentication process for remote code execution

CERT VULNERABILITY NOTE CVE-2015-6563


Fixed a privilege separation weakness related to PAM support. Attackers who could successfully compromise
the pre-authentication process for remote code execution and who had valid credentials on the host could
impersonate other users

CERT VULNERABILITY NOTE CVE-2015-5986


An incorrect boundary check could cause DNS service to terminate due to a REQUIRE assertion failure. An
attacker could deliberately exploit this by providing a maliciously constructed DNS response to a query.

CERT VULNERABILITY NOTE CVE-2015-5722


Parsing a malformed DNSSEC key could cause a validating resolver to exit due to a failed assertion. A remote
attacker could deliberately trigger this condition by using a query that required a response from a zone
containing a deliberately malformed key.

CERT VULNERABILITY NOTE CVE-2015-5477


© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 20 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

A remotely exploitable denial-of-service vulnerability that exists in all versions of BIND 9 currently supported.
It was introduced in the changes between BIND 9.0.0 and BIND 9.0.1.

CERT VULNERABILITY NOTE CVE-2015-6364 and CVE-2015-5366


A flaw was found in the way the Linux kernel networking implementation handled UDP packets with incorrect
checksum values. A remote attacker could potentially use this flaw to trigger an infinite loop in the kernel,
resulting in a denial of service on the system, or causing a denial of service in applications using the edge
triggered epoll functionality.

CERT VULNERABILITY NOTE CVE-2015-1789


The X509_cmp_time function in crypto/x509/x509_vfy.c in OpenSSL before 0.9.8zg, 1.0.0 before 1.0.0s, 1.0.1
before 1.0.1n, and 1.0.2 before 1.0.2b allowed remote attackers to cause a denial of service (out-of-bounds
read and application crash) via a crafted length field in ASN1_TIME data, as demonstrated by an attack against
a server that supported client authentication with a custom verification callback.

CERT VULNERABILITY NOTE CVE-2015-1790


The PKCS7_dataDecodefunction in crypto/pkcs7/pk7_doit.c in OpenSSL before 0.9.8zg, 1.0.0 before 1.0.0s,
1.0.1 before 1.0.1n, and 1.0.2 before 1.0.2b allowed remote attackers to cause a denial of service (NULL
pointer dereference and application crash) via a PKCS#7 blob that used ASN.1 encoding and lacks inner
EncryptedContent data.

CERT VULNERABILITY NOTE CVE-2015-1792


The do_free_upto function in crypto/cms/cms_smime.c in OpenSSL before 0.9.8zg, 1.0.0 before 1.0.0s, 1.0.1
before 1.0.1n, and 1.0.2 before 1.0.2b allowed remote attackers to cause a denial of service (infinite loop) via
vectors that triggered a NULL value of a BIO data structure, as demonstrated by an unrecognized X.660 OID for
a hash function.

CERT VULNERABILITY NOTE CVE-2015-1781


A buffer overflow flaw was found in the way glibc's gethostbyname_r() and other related functions computed
the size of a buffer when passed a misaligned buffer as input. An attacker able to make an application call any
of these functions with a misaligned buffer could use this flaw to crash the application or, potentially, execute
arbitrary code with the permissions of the user running the application.

CERT VULNERABILITY NOTE CVE-2015-4620


A recursive resolver configured to perform DNSSEC validation, with a root trust anchor defined, could be
deliberately crashed by an attacker who could cause a query to be performed against a maliciously constructed
zone.

CERT VULNERABILITY NOTE CVE-2015-0235


Addressed an internal issue in C library (GNU C Library gethostbyname*). Although it was not possible to exploit
this as a security issue in NIOS, it could cause some incorrect error conditions and messages while administering
the product.

CERT VULNERABILITY NOTE CVE-2014-9298


An attacker could bypass source IP restrictions and send malicious control and configuration packets by
spoofing ::1 addresses because NTP's access control was based on a source IP address.

CERT VULNERABILITY NOTE CVE-2014-8500


Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory
exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation.

CERT VULNERABILITY NOTE CVE-2014-8104


The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could
cause a critical denial of service on Open VPN servers through a small control channel packet.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 21 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

CERT VULNERABILITY NOTE CVE-2014-3566


SSL3 is vulnerable to man-in-the-middle-attacks. SSL3 is disabled in NIOS, and connections must use TLSv1
(which is already used by all supported browsers).

CERT VULNERABILITY NOTE CVE-2014-3567


A denial of service vulnerability that is related to session tickets memory leaks.

CERT VULNERABILITY NOTE CVE-2014-7187


Off-by-one error in the read_token_word function in parse.y in GNU BASH through v. 4.3 allowed remote
attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an
unspecified impact through deeply nested for loops (also known as the "word_lineno" issue).

CERT VULNERABILITY NOTE CVE-2014-7186


The redirection implementation in parse.y in GNU BASH through v. 4.3 allowed remote attackers to cause a
denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through
the "redir_stack" issue.

CERT VULNERABILITY NOTE CVE-2014-6271, CVE-3014-6277, CVE-2014-6278, AND CVE-2014-7169


GNU Bash through v. 4.3 processed trailing strings after function definitions in the values of environment
variables, which allowed remote attackers to execute arbitrary code via a crafted environment (also known as
the "ShellShock" vulnerability)."

CERT VULNERABILITY NOTE CVE-2014-3470


Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service.

CERT VULNERABILITY NOTE CVE-2014-0224


A specially crafted handshake packet could force the use of weak keying material in the SSL/TLS clients,
allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server.

CERT VULNERABILITY NOTE CVE-2014-0221


Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service.

CERT VULNERABILITY NOTE CVE-2014-0198


Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that
could cause a denial of service.

CERT VULNERABILITY NOTE CVE-2014-0195


Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS
client or server, resulting in a denial of service.

CERT VULNERABILITY NOTE CVE-2014-0591


A crafted query against an NSEC3-signed zone could cause the named process to terminate.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 22 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

RESOLVED ISSUES

The following issues were reported in previous NIOS releases and resolved in this release. The resolved issues
are listed by severity. For descriptions of the severity levels, refer to Severity Levels on page 30.

Fixed in 7.3.0

ID Severity Summary
NIOS-57442 Critical In certain situations, unable to import DS records even when the delegation NS
records existed in the parent zone.
NIOS-57186 Critical Addressed the following vulnerability:
CVE-2015-8605: A badly formed packet with an invalid IPv4 UDP length field could
cause a DHCP server, client, or relay program to terminate abnormally, causing a
denial of service.
NIOS-57084 Critical On some occasions, the appliance encountered issues when there were bulk AXFR
requests to a zone with bulk hosts configured, causing DNS and DHCP service outage.
NIOS-56925 Critical Under certain circumstances, reporting members in the Grid were not sending traffic.

NIOS-56643 Critical Grid members communicating with the Grid Master through the MGMT port that was
hardcoded with port speed and duplex settings might fail to join the Grid after an
upgrade.
NIOS-56423 Critical Addressed the following vulnerability:
CVE-2015-8000: If responses from upstream servers contained an invalid class
parameter for certain record types, DNS service might terminate with an assertion
failure.
NIOS-56280 Critical In a particular Grid configuration, zone change notifications that included GSS-TSIG
NIOS-55902 keys sent from the DNS primary to the secondary did not function properly.
NIOS-56097 Critical On special occasions, creating a delegated zone could cause DNS outage.

NIOS-56036 Critical Under certain circumstances, DHCP failover peers stayed in the “Communication
Interrupt” state even when connection was established and DHCP service was
restored.
NIOS-55882 Critical When logging in from the serial console, the primary TACACS authentication failed
while using an RSA token.
NIOS-55872 Critical Observed a reduction in GUI performance for superusers.

NIOS-55869 Critical Performing some tasks in Grid Manager, such as adding a comment to a network or
modifying authoritative zones, took longer than expected.
NIOS-55860 Critical Unable to view the syslog messages when the auto synchronization was complete after
joining a member to the Grid.
NIOS-55847 Critical An RPZ (Response Policy Zone) was not properly transferred to the Grid Secondary due
to missing NS records in the zone.
NIOS-55820 Critical Under certain circumstances, the reporting server could not generate reports after a
power outage.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 23 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-55805 Critical Addressed the following vulnerabilities:


CVE-2015-5364 and CVE-2015-5366:
A flaw was found in the way the Linux kernel networking implementation handled UDP
packets with incorrect checksum values. A remote attacker could potentially use this
flaw to trigger an infinite loop in the kernel, resulting in a denial of service on the
system, or causing a denial of service in applications using the edge triggered epoll
functionality.
NIOS-55757 Critical This release addresses the change of IPv4 and IPv6 addresses for the DNS root zone
H.ROOT-SERVERS.NET.
NIOS-55614 Critical Unable to log in to Grid Manager after executing the reset all command.

NIOS-55519 Critical Unable to convert the secondary peer of a DHCP failover association to a regular Grid
member.
NIOS-55491 Critical Standalone HA appliances might not be able to upgrade properly when the interface
port speed was configured to 10/100 Full Duplex instead of auto-negotiate.
NIOS-55373 Critical Under certain memory related circumstances, a process might fail and could not be
restarted.
NIOS-55152 Critical The appliance encountered false RAID array warning messages.

NIOS-55050 Critical The appliance experienced high disk utilization due to data buildup in the reporting
directory.
NIOS-54036 Critical Missing reporting data could occur due to unstable network connection and time
synchronization issues between the Grid Master and members.
NIOS-53494 Critical Under certain circumstances, the appliance experienced high DNS latency issues due
to a large number of bulk hosts.
NIOS-53146 Critical NIOS failed to return a normalized DNAME in lower case for the PTR record, causing a
DNS service outage.
NIOS-52048 Critical When the SCP or FTP server was unavailable, DNS query and response logs could cause
disk usage to grow in the reporting partition.

ID Severity Summary
NIOS-57685 Major Files uploaded to a Grid member through FTP were not properly synchronized to the
Grid Master.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 24 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-57488 Major Addressed the following BIND security vulnerabilities:

CVE-2015-8704: A DNS server could exit due to an INSIST failure in apl_42.c when
performing certain string formatting operations. Examples included but might not be
limited to the following:
 Slaves using text-format db files could be vulnerable if receiving a malformed
record in a zone transfer from their masters.
 Masters using text-format db files could be vulnerable if they accepted a
malformed record in a DDNS update message.
 Recursive resolvers were potentially vulnerable when logging, if they were fed
a deliberately malformed record by a malicious server.
 A server which had cached a specially constructed record could encounter this
condition while performing 'rndc dumpdb'.

CVE-2015-8705: In some versions of BIND, an error could occur when data that had
been received in a resource record was formatted to text during debug logging.
Depending on the version in which this occurred, the error could cause either a
REQUIRE assertion failure in buffer.c or an unpredictable crash (e.g. segmentation
fault or other termination). This issue could affect both authoritative and recursive
servers if they were performing debug logging. Note that NIOS 7.1.0 through 7.1.8 and
NIOS 7.2.0 through 7.2.4 were affected by this vulnerability.

NIOS-57396 Major Unable to delete auto-generated records for IP reservations.

NIOS-57395 Major In situations where the appliance applied a large number of configured ACEs and ACLs
along with restricted access to the remote console and GUI/API access, SSH with
authentication failed (even though the same authentication worked with GUI or HTTPS
access).
NIOS-57283 Major When running a traffic capture over the HA interface, the appliance did not capture
DNS queries sent to the VIP.
NIOS-57188 Major Under certain circumstances, the IB-4030 appliance might go offline if it was
processing a high volume of traffic, such as running top domain/NXDomain reports.
NIOS-57155 Major Cloud Network Automation: When trying to convert an IP address of a VM with
multiple IPs to host, the appliance also selected the first listed IP regardless of which
IP the user selected.
NIOS-57154 Major vDiscovery: Users could not update the secret key for AWS endpoints through the
WAPI.
NIOS-57139 Major Users could not select “Discover Now” from the Action menu for a specific IP address.

NIOS-57111 Major Under certain circumstances, the DNS service restarted due to capturing DNS
responses for reporting.
NIOS-57040 Major In the Infoblox NIOS Administrator Guide, added a note to indicate that traffic
capture files were shared among different admin users.
NIOS-56998 Major Unable to modify IPAM networks using CSV import.

NIOS-56972 Major The DHCP server did not offer a fixed address when the client was identified only
based on the client identifier (DHCP option 61).

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 25 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-56829 Major After executing the set upgrade_forced_end CLI command, some Grid members
stayed in the “Synchronizing” state until the “upgrade_message_sent” file was
cleared.
NIOS-56747 Major The PT-1400 appliance encountered some issues with the smart NIC card.

NIOS-56578 Major Unable to remove an authoritative reverse-mapping zone under certain circumstances.

NIOS-56564 Major Added threat protection rules for DNS tunneling in the Threat Protection Rules
appendix.
NIOS-56541 Major Unable to join a member to the Grid due to invalid IFMAP objects in the database.

NIOS-56476 Major The source IP address for downloading threat protection rules was different between
NIOS releases.
NIOS-56473 Major Multi-Grid Configuration: After upgrading sub Grids, users could not query extensible
attributes and their values through the PAPI.
NIOS-56415 Major Testing LDAP authentication failed against Active Directory servers failed.

NIOS-56402 Major Grid Manager displayed an error in the Dashboard tab -> Status tab after users
removed a Network Insight member from the Grid.
NIOS-56397 Major Unable to configure all Grid member to have a specific Grid member as the
conditional forwarder, which also had a conditional forwarder for the same zone to an
external server.
NIOS-56289 Major Addressed the following issues:
 Instant javascript execution when entering HTML code in the Username field.
 Certain types of Java script were executed when used in the Go to field of the IP
Map and NetMap panels.
 Javascript safe check for Smart Folder names.
NIOS-56282 Major Unable to access Grid Manager when using a certain version of Internet Explorer
browser.
NIOS-56218 Major Some IB-4030 appliances in the Grid experienced intermittent latency peaks in DNS
query responses.
NIOS-56217 Major A scheduled discovery job failed to start if the time zone was configured for UTC/CST.

NIOS-56209 Major A CSV import triggered high CPU utilization.

NIOS-56357 Major After enabling Microsoft synchronization, Grid Manager became sluggish and swap
usage increased.
NIOS-56166 Major DNS integrity check returned a “None” status for a domain that did not have
delegation and had a dotted label between the parent label and the actual domain.
NIOS-56100 Major DNS service failed to start due to an undefined ACL syntax error.

NIOS-56050 Major Unable to remove Microsoft servers from the Grid due to undefined email address for
a zone.
NIOS-56027 Major The appliance logged DNSSEC error messages about missing private key files even
though they were not required for pre-published keys.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 26 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-55986 Major The appliance stopped counting DNS queries after an upgrade even though monitoring
was enabled.
NIOS-55984 Major Unable to save modified member DNS properties.

NIOS-55977 Major In a configuration that supported multiple primaries for a zone (MMDNS support),
DDNS updates sent by one of the Grid members were not resolved for a few days.
NIOS-55901 Major The appliance might send invalid email alerts when a change in the monitoring state
happened without a valid monitoring object.
NIOS-55855 Major The appliance was unable to load Global Smart Folders; and the folders were marked
as invalid in Grid Manager.
NIOS-55851 Major vNIOS for KVM could not run probably on certain NIOS versions.

NIOS-55842 Major The permission table for resources was missing in the “Create Object Permissions”
dialog for a network.
NIOS-55833 Major The DNS Query Rate by Server/Server Group report might display incorrect data on
the IB-4030 appliance due to data parsing issues.
NIOS-55830 Major In the Infoblox NIOS Administrator Guide, added information about remote admin
objects being purged after 180 days without activities.
NIOS-55827 Major Captive Portal service failures occurred after deleting the self-signed certificate.

NIOS-55821 Major High CPU usage was observed after an upgrade due to memory issues related to a
large number of host objects and host address objects.
NIOS-55812 Major Network Insight: The appliance returned an error when users tried to drill down to the
Interface tab of a discovered device.
NIOS-55763 Major DHCP service went into a restart loop on one of the DHCP failover peers, causing DHCP
outage.
NIOS-55693 Major Reporting: Downloading and emailing PDF for reports failed.

NIOS-55688 Major On a Network Insight member, the swap space usage increased unexpectedly.

NIOS-55685 Major WAPI requests for discovered data could fail if the queried objects did not have any
discovered data for display.
NIOS-55667 Major The reporting server failed to display reports for certain Grid members.

NIOS-55630 Major Updated information about NTP service on different interfaces in the Infoblox NIOS
Administrator Guide.
NIOS-55628 Major Addressed the following vulnerabilities:
CVE-2015-6563: Fixed a privilege separation weakness related to PAM support.
Attackers who could successfully compromise the pre-authentication process for
remote code execution and who had valid credentials on the host could impersonate
other users.
CVE-2015-6564: Fixed a use-after-free bug related to PAM support that was reachable
by attackers who could compromise the pre-authentication process for remote code
execution.
NIOS-55594 Major The appliance treated a trailing escape character (\) as an invalid character in a TXT
record.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 27 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-55567 Major In an Anycast configuration, BGP peering was not automatically re-established after
the connection dropped.
NIOS-55545 Major Under certain circumstances, HA members experience DNS outage after an upgrade.

NIOS-55497 Major WAPI: The pxe_lease_time option could only be used to modify an existing setting.
Users could not use this option to configure new settings for any objects except for
host records that were enabled for DHCP.
NIOS-55496 Major This release adds a few enhancements to the DNAME Record wizard and editor to
avoid a DNAME loop, in which the owner name is identical to the RDATA.
NIOS-55489 Major The FTP server failed to provide configuration files to VoIP phones after a PBX reset.

NIOS-55468 Major IPv4 DHCP option logic filters associated with DHCP ranges were no longer visible in
Grid Manager after an upgrade if DHCP option filters were deployed and inheritance
was enabled before the upgrade.
NIOS-55467 Major Unable to set up an HA passive node through the NIOS Setup Wizard.

NIOS-55458 Major Menu items were missing from the Action menu of the static and pool licenses in the
Active Licenses tab.
NIOS-55399 Major Zone transfers between the lead secondary and the PT Grid member functioned only
in the monitoring mode. The zone transfers did not happen in the block mode.
NIOS-55264 Major API: Users were able to configure the IB-100 appliance as a Grid Master, which is not
supported.
NIOS-55239 Major Unable to use the set partnerdown command on the secondary DHCP failover peer
in the maintenance mode.
NIOS-55234 Major The reset all secure command did not remove all data in the
/storage/reporting-capture-data directory.
NIOS-55218 Major Grid Master failed to display reports due to report timeouts, despite proper
communications between the forwarder and indexer.
NIOS-55120 Major Under certain circumstances, DHCP service outage occurred.

NIOS-55079 Major Under certain circumstances, Microsoft synchronization failed for specific servers.

NIOS-55059 Major The passive node of an HA Grid Master encountered a replication failure due to a
heartbeat timeout on the active node.
NIOS-55040 Major The appliance failed to forward Cache Hit Rate statistics to the Reporting server.

NIOS-54860 Major Cloud Network Automation: Unable to send WAPI calls using the cloud-api-only admin
group.
NIOS-54762 Major Required and inherited extensible attributes from the parent level were not populated
NIOS-54263 after converting an unmanaged object to a host record.
NIOS-54721 Major Incomplete CSV and PDF files received for exports of reporting data.

NIOS-54407 Major The DHCP server was unable to update DNS entries and received REFUSED responses.

NIOS-54244 Major The IPAM tab displays incorrect usage percentage for a network.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 28 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-52958 Major Did not get leases for fixed addresses when the “Enable immediate fixed address
configuration changes” option was selected in the Grid DHCP Properties editor.
NIOS-51536 Major Performing certain tasks in Grid Manager took longer than expected.

NIOS-48008 Major Unable to retrieve network names from some DHCP ranges.

NIOS-31917 Major Unable to group discovered managed data in smart folders.

NIOS-57690 Minor PAPI: Limited-access users could not perform a VM registration.

NIOS-57512 Minor Clicking the syslog bookmark for a Grid member redirected users to the syslog for
another member.
NIOS-57183 Minor Clarified the online Help related to the “Keep local copy” when scheduling a Grid
backup.
NIOS-57140 Minor PAPI: Under certain circumstances, users could not copy an HA member.

NIOS-56950 Minor Missing sysObjectIDs for PT appliances in the Infoblox NIOS Administrator Guide.

NIOS-56824 Minor The CLI command set partnerdown for a DHCP failover peer did not function
properly.
NIOS-56819 Minor Cloud Network Automation: The VPN communication between the Consolidator and
Probes was not documented.
NIOS-56782 Minor Documented the reason for IP discovery to send packets to the UDP 40125 port.

NIOS-56737 Minor Fixed the OID for IB-DNSQUERYRATE in the Infoblox NIOS Administrator Guide.

NIOS-56654 Minor An SNMP manager failed to receive test SNMP traps from the NIOS appliance.

NIOS-56628 Minor The appliance intermittently returned an error when users opened the Administration
tab in Grid Manager.
NIOS-56606 Minor Threat Protection: The name resolving time out interval was too short for threat
protection test connection.
NIOS-56396 Minor In the Infoblox NIOS Administrator Guide, added information about DHCP Utilization
for network and range to include abandoned addresses or leases.
NIOS-56208 Minor Fixed an error in the description of the set transfer_supportbundle CLI
command.
NIOS-56188 Minor When adding a DNAME record, users could use the domain name of a zone in the
NIOS-55506 DNAME data portion, which could cause a circular reference.
NIOS-56176 Minor Clarified the description for “Proxy Access Control” in the Infoblox NIOS Administrator
Guide.
NIOS-56175 Minor Added timestamp to the show cores CLI command.

NIOS-56170 Minor PAPI: Traffic capture calls using API did not work when the interface was set to
LAN/LAN1.
NIOS-56124 Minor When generating a User Login History report using the filters “User Status equals
Active” and “User Status equals Timed Out,” the report showed incorrect status.
NIOS-56116 Minor A CSV import failed while trying to restore some host records.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 29 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-56105 Minor On some occasions, users were unable to save extensible attribute values because the
Save button was disabled.
NIOS-56083 Minor A limited-access user group encountered an issue when trying to trying to navigate to
a DNS zone.
NIOS-56054 Minor Fixed the documentation to reflect that the IB-4030 appliance fully supports IPv4 and
IPv6 queries.
NIOS-55967 Minor Users encountered some LCD issues on the passive node of the HA Grid Master.

NIOS-55964 Minor Unable to configure the “remove-subnet” field in the CSV import file due to an
incorrect reference (“remove_subnet”) documented in the CSV Import Reference.
NIOS-55854 Minor Secondary zone data was not available for the root zone.

NIOS-55845 Minor Fixed AWS endpoint example in the Infoblox NIOS Administrator Guide.

NIOS-55829 Minor Fixed a typo in the DNS Top RPZ Hits by Client report.

NIOS-55775 Minor Added port information to the Infoblox NIOS Administrator Guide and the Installation
Guide for vNIOS for AWS.
NIOS-55694 Minor Reporting: Search results were not copied to the SCP server based on the
configuration.
NIOS-55643 Minor Updated version 3.0.1 and 3.0.2 of the Installation Guide for IPAM Plug-In for vCO to
reflect the correct information.
NIOS-55629 Minor Added threat protection rules for EARLY PASS UDP in the Infoblox NIOS Administrator
Guide.
NIOS-55627 Minor Unable to set external primary DNS servers to stealth mode.

NIOS-55591 Minor Unable to change permissions for FTP file distributions; and no additional details were
logged to the debug log or the infoblox.log.
NIOS-55583 Minor The SNMP values were swapped between the active and passive nodes of an HA pair.

NIOS-55552 Minor Added a note to the WAPI documentation to remind users to set the zone_format
value when creating reverse-mapping zones.
NIOS-55470 Minor For the “Synchronize Network Users” option in Network Users tab of the Microsoft
Server Properties editor, Grid Manger displayed “Inherited from Upper Level” instead
of “Inherited from Grid.”
NIOS-55444 Minor The Edit menu item was missing from the Action menu of DNS resource records.

NIOS-55405 Minor The audit log history did not record the creation or modification of a host record.

NIOS-55284 Minor Selecting a network view in the Network View Selector could slow down some
operations if the page size for the selector was configured for a larger value.
NIOS-55277 Minor API: Under certain circumstances, users could not retrieve all extensible attribute
definitions through the API.
NIOS-54753 Minor Inconsistent NIOS versioning could cause automated PAPI updates to fail.

NIOS-53793 Minor Microsoft Management: Synchronization test could fail if the “Use same credential as
DNS/DHCP services” option was enabled.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 30 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-53598 Minor Grid Manager performance was affected when adding more than one record to a large
DNS zone.
NIOS-53164 Minor A CSV import filed when an ACL list contain a large number of entries.

NIOS-52351 Minor A host record could appear twice in a smart folder.

NIOS-52035 Minor The traffic capture limit was inadequate for threat protection appliances.

NIOS-51640 Minor The tenant name was not included in the VM Address History report.

NIOS-49306 Minor The modification of BOOTP properties of a host IP address was not recorded in the
audit log.
RFE-6323 Enhance Infoblox now provides an option to set the prefix length limit for RPZ-IP triggers so
you can avoid the possibility of DNS outage resulting from errors in the RPZ policies
received from external sources by the RPZ feed or due to errors in the RPZ rules
added to the local RPZ.

Severity Levels

Severity Description
Critical Core network services are significantly impacted.
Major Network services are impacted, but there is an available workaround.
Moderate Some loss of secondary services or configuration abilities.
Minor Minor functional or UI issue.
Enhance An enhancement to the product.

KNOWN GENERAL ISSUES

ID Summary
N/A Infoblox has upgraded the software for our user community (community.infoblox.com), which
will offer users enhanced features and a more robust experience. This new community software
however, is not compatible with our community dashboard widget. As a result, the functionality
of the Community Dashboard widget is inconsistent. The Community Dashboard widget will
subsequently be removed in the next NIOS maintenance release.
NIOS-58000 In AWS, if the admin-password set as part of the user data is modified later in virtual NIOS
appliance, it will be reverted back to the original user data password during a NIOS upgrade.
NIOS-57932 Reporting and Analytics: Alerts are not generated for some of the reports in the DHCP
Fingerprint category.
NIOS-57930 Reporting and Analytics: Object permissions for certain system searches are not migrated after
an upgrade.
Workaround: Superusers can fix these permissions for limited-access users when necessary.
NIOS-57850 Reporting and Analytics: Custom logos in report PDFs might not appear properly if the logo is in
JPEG format.
Workaround: Use logos that are in PNG format.

© 2016 Infoblox Inc. All Rights Reserved. All registered trademarks are property of their respective owners. Page 31 of 32
400-0619-000 Rev. B 2/1/2016
NIOS 7.3.0 Release Notes

NIOS-56982 Reporting and Analytics: Unable to copy or bookmark a page using the “Link to Job” option in
the Job Settings dialog in the Splunk -> Reports page.
RPTNEXTGEN- Reporting and Analytics: You cannot set any dashboard as the home dashboard. The Set as Home
558 Dashboard option available in the Edit drop-down will not add dashboards to the Home
Dashboard tab.
RPTCLUSTER- Reporting and Analytics: Time zone information is not displayed for the following reports: DNS
337 Domains Queried by Client, Top DNS Clients by Query Type, Top DNS Clients Querying MX
Records, and DNS Domain Query Trend.
RPTCLUSTER- Reporting and Analytics: User might not be authorized to use the reporting service and cannot
331 access the Reporting tab after restoring the NIOS Grid backup.
NIOS-57195 Microsoft Management: After configuring Microsoft AD servers in the Grid, the Microsoft
managing member might go into a “synchronize” mode and restarts continuously.
NIOS-57041 MMDNS: Under certain circumstances, assigning multiple primaries to a Grid member might cause
the member to fail.
NIOS-55312 An RPZ rule that was deleted and then added to an RPZ feed again might not take effect
immediately. This delay is mandated by the effective DNS cache setting and might cause some
traffic to go through before the RPZ rule takes effect.
Workaround: To ensure that the RPZ rule takes effect immediately, clear the DNS cache before
adding the rule.
BEAU-443 Cloud Network Automation: In a scenario when you define extensible attributes that have the
exact same name (such as Tenant ID) as the mandatory cloud extensible attribute before you
install a cloud license in the Grid, the mandatory cloud extensible attribute creation will fail
when you install the cloud license.
Workaround:
1. Uninstalled the cloud license.
2. Delete the extensible attributes that have the same name as the mandatory cloud
extensible attributes.
3. Install the cloud license again.
DNSSDU-163 DNS Secure Dynamic Updates: Analysis might take longer than expected on the IB-4010 that has a
25% database capacity.
DNSSDU-222 DNS Secure Dynamic Updates: A Grid member might go offline if the record type for resource
records is changed from “static” to “dynamic” after a DHCP failover.
ISE-249 Cisco ISE: Unable to create a network active user if the user is configured with Cisco ISE server
using the standby server address.
NETMRI- Network Insight: When adding seed routers through PAPI scripts, ensure that you specify the
26525 network view with which the seed router associates. Otherwise, the seed router object will be
created without a network view association.