Project : Banquet Hall

Address: Khsra No. 1252, T&P- Kulpahar, Tehsil- kulpahar, Distt- Mahoba, U.P,
Client : Savita

LOAD CALCULATION ON BUILDING


Description thickness of wall Density of Brick wall height clear TOTAL LOAD
with plaster (m) (KN-M) OF WALL

230 mm Thk. Wall weight 0.25 19.2 2.69 12.912 KN/M


115 mm Thk, Wall weight 6.456 KN/M
Parapet Wall 0.125 Thk 0.125 19.2 1 2.4 KN/M

Description thickness of wall Density of Brick wall height clear TOTAL LOAD
with plaster (m) (KN-M) OF WALL

DL Of Slab 0.125 25 3.125 KN/M2


Floor Finish 1 KN/M2
4.125 KN/M2

LL for upper residential unit 3.00 KN/M2

Footing-F1
fy 1643 KN 164.3 T
MX 2.52 KN-M 0.252 T-M
MZ 94.61 KN-M 9.461 T-M

Footing-F2
fy 840 KN 84 T
MX 33 KN-M 3.3 T-M
MZ 2.46 KN-M 0.246 T-M

Footing-F3
fy 273 KN 27.3 T
MX 4.71 KN-M 0.471 T-M
MZ 16.55 KN-M 1.655 T-M

Footing-F4
fy 403 KN 40.3 T
MX 2.31 KN-M 0.231 T-M
MZ 22.72 KN-M 2.272 T-M
FLOOR HEIGHT NODES FOR FLOOR LOAD
1st Floor 2nd Floor 3rd Floor Terrace Mumty
5 8.15 11.3 14.45 17.45
5.2 8.35 11.5 14.65 17.65

25% of Load
0.75 4.875
BUILDING INFORMATION
l Z-dir 34.44 m
b X-dir 12.2 m
h y-dir 3.6 m Ground
No. of floor ht (m)
1st 1 3
2nd 1 3
3rd 1 3
FLOORS 1
THAN TOTAL- h 12.6 m

LOAD DESCRIPTION
DLF 3.125 KN/M2 AS PER IS875-PART-1
FLOOR FINISH 1.5 KN/M 2
AS PER IS875-PART-1
TOTAL 4.625 KN/M 2

DLW 13.2 kn/m


LL/IL 3.0 KN/M2 AS PER IS875-PART-2

No Dynamic Effect of wind

zone (z) IV ZONE CATEGORY


(I) OTHER , INDUSTRY BUILDING USES/IMPRTANCE
(R) SMRF FRAME STRUCRURE TYPE
(T) A BUILDING CONDITION (OPEN/GLAZED/STEEL/ BRICK)
(ST) MS SOIL TYPE

Ah Design Horizontal Acceleration spectrum


Z I Sa
X X
Ah = 2 R g

0.24 X 1 X 2.50
Ah = 2 5
= 0.12 X 0.2 X 2.50
Ah = 0.06

Ah Should be taken is less than ' Z/2'


Ah
condition to took the value of Ah as per IS1893-P1-2002

1 where no. of modes to be considered for dynamic analysis,


the value of Ah as defined above for each mode shall be
determined using the natural period of vibration of that mode.
2 for underground structures and foundations at depth of 30m or below
than [Ah=Ah/2]
3 for structures and foundation placed between the ground lvl. & 30m depth
than Ah interpopolated between Ah & 0.5Ah
4 the design acceleration spectrum for vertical motion, when required
may be taken (2/3)Ah
seismic weight of one floor(w) = 3203.78 Kn
Seismic weight of building (W) =(W X No. Of floors) 6407.56 Kn

design seismic base shear or total design lateral forces

VB = Ah X W
= 384.45 Kn

vertical distribution of base shear to different floor levels

Qi = VB x W i X h i 2
n
∑ x Wj x hj
j=1

=
The value of the shaft resistance coefficient, β, for the
estimation of negative skin friction should be
assessed based on basic soil mechanics principles.
However, in the absence of more accurate
assessment, an empirical value of β = 0.25 may be
assumed.

seismic coefficient taken for design 0.1 to 0.3 α0 0.04


importance factor I 1
soil-foundation system factor (β) 1

Design Horizontal Seismic Coefficient (αh)=β Iα0 αh 0.04

2.14 Seismic Coefficients and


Seismic Zone Factors

2.14.1

Basic Seismic Coefficient (αo)—A coefficient


assigned to each seismic zone to give the basic
design acceleration as a fraction of the
acceleration due to gravity.

2.14.2

Seismic Zone Factor (Fo)—A factor to be used for


different seismic zone along with the average
acceleration spectra.

2.14.3

Importance Factor (I)—A factor to modify the


basic seismic coefficient and seismic zone factor,
depending on the importance of a structure.

2.14.4
Soil-Foundation System Factor (β)—A factor to
modify the basic seismic coefficient and seismic
zone factor, depending upon the soil foundation
system.

2.14.5

Average Acceleration Coefficient—Average


spectrum acceleration expressed as a fraction of
acceleration due to gravity.

TABLE 2 VALUES OF BASIC SEISMIC COEFFICIENTS AND SEISMIC ZONE FACTORS IN DIFFERENT ZONES
(Clauses 3.4.2.1, 3.4.2.3 and 3.4.5)
Sl No. Zone No. Method
Seismic
Coefficient
Method
Basic horizontal
seismic
coefficient αo
-1 -2 -3
i) V 0·08
ii) IV 0·05
iii) III 0·04
iv) II 0·02
v) I 0·01
Note—For under ground structures and foundations at 30 m depth or below, the basic seismic coefficient may be take
αo; for structures placed between ground level and 30 m depth, the basic seismic coefficient may be linearly interpola
between αo and 0·5 αo.

The seismic coefficients according to 3.4.2.1 for some important towns and cities are given in Appendix E.

TABLE 3 VALUES OF β FOR DIFFERENT SOIL-FOUNDATION SYSTEM


(Clause 3.4.3)
Sl No. Type of Value
Soil
Piles Passing
Mainly
Through Any
Constituti
Soil, but Resting
ng the
on Soil Type I
Foundatio
n

-1 -2 -3
i) Type I 1·0
Rock or
hard soils

ii) Type II 1·0


Medium
soils
iii) Type III 1·0
Soft soils
Note—The value of β for dams shall be taken as 1·0.
1.5
1.2 foundation
MIC ZONE FACTORS IN DIFFERENT ZONES
nd 3.4.5)
Method
Response Spectrum Method
(see Appendix F)

Seismic zone factor for average


acceleration spectra to be used with Fig.
2, Fo
-4
0·40
0·25
0·20
0·10
0·05
low, the basic seismic coefficient may be taken as 0·5
seismic coefficient may be linearly interpolated

and cities are given in Appendix E.

FOR DIFFERENT SOIL-FOUNDATION SYSTEMS


(Clause 3.4.3)
Values of β for
Piles Not Covered Under Col 3 Raft Combined Isolated Well
Foundatio or Isolated RCC Foundatio
ns RCC Footings ns
Footings Without
with Tie Tie Beams
Beams or
Unreinforc
ed Strip
Foundatio
ns

-4 -5 -6 -7 -8
– 1·0 1·0 1·0 1·0

1·0 1·0 1·0 1·2 1·2

1·2 1·0 1·2 1·5 1·5


Building data

Length 80 m
bay spacing 7.75 m
width 35 m
width bay spacing 7m
Clear ht. 10 m
roof slope 1 20
Angle 2.8624052
building Condition Partial

(Dead load) DL 15 Kg/m2


1.1625 Kn/m

(Live Load) LL 75 Kg/m2


5.8125 Kn/m

Colletrol load(CL) 1 Kg/m2


0.0775 Kn/m

Earthquake Load 0.5(50%of live load)+Dead Load


4.06875 Kn/m

Wind Load

Basic wind speed (Vb) 47 m/s


Risk Coeficient (k1) 1
Tarrain category (k2) 0.98 (class-B, T2)
Topography Factor (k3) 1 (Area Factor Such as Hill, Valley, Plain etc)

Design Wind Speed (Vz) = VbXk1Xk2Xk3 m/s

= 46.06 m/s

Design wind pressure = 0.6Vz2 N/m2


1272.9142 N/m2
1.2729142 KN/m2

internal Coeficient Cpi 0.2 0.5 0.7


Enclosed Partial Open
Enlosed

external Coeficient Cpe h/w 0.286


see table 4
IS875 Part-3
l/w 2.285714
External coeficient Cpe for wall of ractangular clad building
WIND ANGLE Ø A B C D local Cpe
0 0.7 -0.25 -0.6 -0.6
-1
90 -0.5 -0.5 0.7 -0.1
External coeficient Cpe for Pitched roof
Roof Angle Wind Angle Ø= 0˚ Wind Angle Ø= 90˚
EF GH EG FH
2.86 -0.86 -0.4 -0.8 -0.4

cpi 0.5
-0.86 -0.4 -0.86 -0.4
-3.52 0.99 -13.4 -8.88

-0.89 -9.80
0.7 -0.25 0.7 -0.25
11.84 -0.5 2.47 1.97 0.5 -7.40

-0.89 -9.80
suction (0 ˚) windward / leeward pressure (0˚) windward / leeward

-0.8 -0.4 -0.8 -0.4


-2.96 0.99 -12.82 -8.88

3.56 -5.35
-0.5 -0.5 -0.5 -0.5
0.00 -0.5 0.00 -9.87 0.5 -9.87

10.69 1.78
suction (90 ˚) windward / leeward pressure (90˚) windward / leeward
TABLE-4 (AS PER IS 875 PART-3 ) Cpe for Wall
Building Height Building Plan Elevation Wind Cpe for Surface
Plan
ratio Ratio Angle Ø A B C D
1<l/w<3/2 0 0.7 -0.2 -0.5 -0.5
90 -0.5 -0.5 0.7 -0.2
h/w<1/2
3/2<l/w<4 0 0.7 -0.25 -0.6 -0.6
90 -0.5 -0.5 0.7 -0.1
1<l/w<3/2 0 0.7 -0.25 -0.6 -0.6
90 -0.6 -0.6 0.7 -0.25
1/2<h/w<3/2
3/2<l/w<4 0 0.7 -0.3 -0.7 -0.7
90 -0.5 -0.5 0.7 -0.1
1<l/w<3/2 0 0.8 -0.25 -0.8 -0.8
90 -0.8 -0.8 0.8 -0.25
3/2<h/w<6
3/2<l/w<4 0 0.7 -0.4 -0.7 -0.7
90 -0.5 -0.5 0.8 -0.1
l/w=3/2 0 0.8 -0.25 -0.8 -0.8
90 -0.8 -0.8 0.8 -0.25
h/w>ᴔ
l/w=1 0 0.7 -0.4 -0.7 -0.7
90 -0.5 -0.5 0.8 -0.1
l/w=2 0 0.7 -0.4 -0.7 -0.7
90 -0.5 -0.5 0.8 -0.1

TABLE-5 (AS PER IS 875 PART-3 ) Cpe for Pitched Roof h/w<=0.5
Building Height Roof Angle ᾱ Wind Angle Ø= 0˚ Wind Angle Ø= 90˚ ROOF 2.862
Ratio ANGLE
degree EF GH EG FH 0 -0.8
0 -0.8 -0.4 -0.8 -0.4 5 -0.9
5 -0.9 -0.4 -0.8 -0.4 0 -0.4
h/w<= 1/2 10 -1.2 -0.4 -0.8 -0.6 5 -0.4
20 -0.4 -0.4 -0.7 -0.6 0 -0.8
30 0 -0.4 -0.7 -0.6 5 -0.8
45 0.3 -0.5 -0.7 -0.6 0 -0.4
60 0.7 -0.6 -0.7 -0.6 5 -0.4
0 -0.8 -0.6 -1 -0.6
5 -0.9 -0.6 -0.9 -0.6
1/2<h/w<=3/2 10 -1.1 -0.6 -0.8 -0.6
20 -0.7 -0.5 -0.8 -0.6
30 -0.2 -0.5 -0.8 -0.8
45 0.2 -0.5 -0.8 -0.8
60 0.6 -0.5 -0.8 -0.8
0 -0.7 -0.6 -0.9 -0.7
5 -0.7 -0.6 -0.8 -0.8
3/2<h/w<6 10 -0.7 -0.6 -0.8 -0.8
20 -0.8 -0.6 -0.8 -0.8
30 -1 -0.5 -0.8 -0.7
40 -0.2 -0.5 -0.8 -0.7
50 0.2 -0.5 -0.8 -0.7
60 0.5 -0.5 -0.8 -0.7
local Cpe
0.25w

-0.8

-1

-1.1

-1.1

-1.2

-1.2

-1.25

-1.25

-1.25

h/w<=0.5 1/2<h/w<=3/2 3/2<h/w<6

-0.857248 -0.8 -0.857248 -0.7 -0.7


-0.9 -0.7
-0.4 -0.6 -0.6 -0.6 -0.6
-0.6 -0.6
-0.8 -1 -0.942752 -0.9 -0.842752
-0.9 -0.8
-0.4 -0.6 -0.6 -0.7 -0.757248
-0.6 -0.8