PLC m5
PLC m5
Recent articles
a day ago
Tags
SCADA is a system of hardware and software elements that facilitate process control. This central control
system consist of communication equipment, network interfaces, input/ output devices and software. It allows
organizations to carry out following functions:
· Direct interaction with devices like valves, motors, pumps, valves using Human Machine Interface (HMI)
software.
History of SCADA
Earlier, the controlling of industrial plants and manufacturing floors can be done manually with the help of analog
equipment and push-buttons. As the industry’s size is growing, so they employed timers and relays to provide
supervisory control to a fixed level for minimal automation. So, a fully automated with a more efficient system
was necessary for all the industries.
We know that, for industrial control purposes, computers were implemented in the year 1950. After that, the
concept of telemetry was implemented for data transmission as well as virtual communication. In the year 1970,
the SCADA system was developed along with the microprocessors as well as PLC.
So these concepts were fully helped while developing automation that is operated in industries remotely. The
distributed SCADA systems were implemented in the year 2000. After that, new SCADA systems were developed
to monitor & control real-time data anyplace in the globe.
Architecture
Operator: Human operator who monitors the SCADA system and performs supervisory control functions for the
remote plant operations
Human machine interface (HMI): Presents data to the operator and provides for control inputs in a variety of
formats, including graphics, schematics, windows, pull-down menus, touch-screens, and so on.
Master terminal unit (MTU): Equivalent to a master unit in a master/ slave architecture. The MTU presents data
to the operator through the HMI, gathers data from the distant site, and transmits control signals to the remote
site. The transmission rate of data between the MTU and the remote site is relatively low and the control method
is usually open loop because of possible time delays or data flow interruptions.
Communications means: Communication method between the MTU and remote controllers. Communication can
be through the Internet, wireless or wired networks, or the switched public telephone network.
Remote terminal unit (RTU): Functions as a slave in the master/slave architecture. Sends control signals to the
device under control, acquires data from these devices, and transmits the data to the MTU. An RTU may be a PLC.
The data rate between the RTU and controlled device is relatively high and the control method is usually closed
loop
In addition to the hardware, the software components of the SCADA architecture are important. Here are some of
the typical SCADA software components:
Desirable properties
A good description of the desired properties of a SCADA system is given in the North American Electric Reliability
Council (NERC) definition of SCADA reliability objectives
Adequacy: The capacity to meet system demand within major component ratings in the presence of scheduled
and unscheduled outage of generation and transmission components or facilities
Security: A system’s capability to withstand system disturbances arising from faults or unauthorized internal or
external actions without further loss of facilities, compromise of human safety, and loss of production
Features of SCADA
The important features of SCADA are the following :
1. Alarm Handling
Alarms Handling
Alarm handling consists essentially of time stamped alarms to 1 millisecond precision. Single network
acknowledgment and control of alarms with Sharing and Displaying of Alarms to all clients in chronological order.
It performs Dynamic allocation of alarm pages and keeps track of deviation and rate of change monitoring for
analog alarms. It has the option of Historical alarm and event logging. It is capable of performing On-line alarm
disable and threshold modification with the option of preparing Event-triggered alarms and Alarm-triggered
reports
Trends
Trend curves and patterns consists of Trend zooming and display of data. It performs Export and Archiving of
historical trend data with Event based trends for Short and long term trend display. It has the option of On-line
change of time-base and retrieval of archived historical trend data.
Real time access and data retrieval consists of Direct, real-time access to data by any network user as well as
Third-party access to real-time data. It has Network compatibility for read, write and exec to all I/O device points.
Support for Direct SQL commands or high level reporting
Computer Networking and processing aspect of supports all compatible networks and protocols. It has
Centralized alarm, trend and report processing – data available from anywhere in the network and Dual networks
for full LAN redundancy. Open architecture design with Real-time multitasking are important features with
Client/server fully supported with Distributed project updates and Concurrent support of multiple display nodes.
Minicomputers were used in the earlier Supervisory Control and Data Acquisition systems. Monolithic systems
were developed during times when ordinary network services were unavailable. These were designed to be
independent systems without any connection to other systems.
All the remote terminal unit sites would connect to a back-up mainframe system for achieving the first generation
SCADA system redundancy, which was used in case of failure of the primary mainframe system. The functions of
the monolithic SCADA systems in the early first generation were limited to monitoring sensors in the system and
flagging any operations in case of surpassing programmed alarm levels.
In the second generation, the sharing of control functions is distributed across the multiple systems connected to
each other using Local Area Network (LAN). Hence, these were termed as distributed SCADA systems. These
individual stations were used to share real-time information and command processing for performing control
tasks to trip the alarm levels of possible problems.
The second generation resulted in the reduction of size and cost of each station but there were no standardized
network protocols. Since the protocols were proprietary, very few people understood the security of Supervisory
Control and Data Acquisition system installation and this factor was largely ignored.
These systems use PLC for adjusting and monitoring the flagging operations only when there is a requirement for
major decisions.
The first and second generation SCADA systems are limited to single site networks or single building called as
sealed systems. In these systems, we can not have any risk compared to the third generation SCADA system
which are connected to the internet causing the security risks. There will be several parallel working distributed
SCADA systems under a single supervisor in network architecture.
PLC SCADA
monolithic,
distributed, networked & IoT
Advantages
The advantages of the SCADA system include the following.
· Thousands of sensors can be interfaced with SCADA for controlling and monitoring
· The SCADA system is easily expandable. We can add a set of control units and sensors according to the
requirement.
Disadvantages
The disadvantages of the SCADA system include the following.
1. Power Generation & Distribution: Used to monitor current flow, voltage, circuit breaker functions. Also used
in remotely switching on/ off of power grids.
2. Water & Sewage System: Used by municipal corporations for regulating and monitoring water flow, reservoir
status, pressure in distribution pipes, etc.
3. Industries and Buildings: Used to control HVAC, central air conditioning, lighting, entry/ exit gates, etc.
4. Oil and Gas Industries: Used for regulating and monitoring flow, reservoir status, pressure in distribution
pipes, etc.
5. Communication Networks: Used for monitoring and controlling servers, networks and nodes.
6. Manufacturing: Used for managing inventories for controlling over manufacturing/ stocking. Also used for
monitoring and regulating instrumentation, process and product quality.
7. Public Transport: Used for regulating subway electricity, automating traffic signals/ railway crossing and live
tracking of flights/ trains/ buses
Petroleum Refining
• Petroleum refineries are extremely important elements in a nation’s critical infrastructure.
• Goods and services depend on transportation by planes, trucks, cars, trains, and boats and on the myriad of
engines running on petroleum based
• fuels.
• The principal function of a refinery is to distill and perform various chemical reactions on the crude oil input.
• These operations require temperatures on the order of 500 to 1,000 degrees Fahrenheit
• Pressures ranging from 150 pounds per square inch (psi) to 3,500 psi.
• In addition to the general fuel products, hydrogen (H) is used and generated and the toxic compounds hydrogen
sulfide (H2S) and ammonia (NH3) are generated.
• In a refinery distillation column the component hydrocarbons can be separated because they have diferent
boiling points that reach from approximately 50 degree Farhenheit to 1400 degree farhenheit
• The sulfur is removed through hydrotreating
• A product of this reaction is the toxic gas hydrogen sulphide (H2S), which results from hydrogen atoms combing
with sulfur atoms.
• It is clear that petroleum refinieries must be kept under strict control in all phases of hydrocarbon processing or
serious damage to human life property and eventually the economy will result
• Result of successful SCADA system attacks might include exceeding temperature and floor escape of toxic
liquids and vapors and contamination of catalysis
• As in nuclear power plants, the heat is applied to water, steam is generated, and the steam is used to power
turbines that turn electricity generators.
• The electrical energy is then transmitted and distributed at different voltages to power substations.
• Figure 2-4 provides a geographic overview of a fossil fuel electric plant and
• After purification, the water is pumped through a transmission system to the water consumers.
• Future expandability
For this type of operation a SCADA system is applied to control and monitor the water purification process,
pumping system and pipeline pressures.
Because of the distance involved in same installation, radio models are used to communicate between the
central supervisory stations and the remote locations
Possible attack scenarios on a water purification and transmission system include jamming or interference with
radio communication links, disabling or interrupting the water purification process, inserting false pressure and
pump data to disrupt transmission operation and modifying water reservoir information
Chemical Plant
• These plants or storage facilities manufacture or hold highly toxic chemicals such as chlorine gas, benzene,
anhydrous ammonia, and boron trifluoride.
• The latter is colorless gas that can kill by attacking a person’s mucous membranes
• Benzene Production:
• Benzene is produced by three different methods. These methods are steam cracking, catalytic reforming, and
toluene hydrodealkylation.
• In the toluene hydrodealkylation process, hydrogen reacts with toluene over a catalyst bed with temperatures
between 500 and 600 degrees Celsius and 40 to 60 atmospheres of pressure.
Tags
Anish Jain
If you find any notes, materials missing or want to contact me you can do so by clickng here