0% found this document useful (0 votes)
68 views4 pages

Naptha Flowmeter Sizing

This document summarizes the technical evaluation of an Altosonic 5 flow meter. It includes specifications for the meter such as its size, material, pressure and temperature ratings, accuracy, and pressure loss calculations. It also notes that the meter will be calibrated according to OIML-R117 standards at Euroloop_Master Meter facility using 6 points and 3 repeats. The meter is rated to measure fuel oil flow rates from 200-1500 cubic meters per hour at pressures from 3-6.5 kg/cm2(g) and temperatures from 60-90 degrees C.

Uploaded by

ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views4 pages

Naptha Flowmeter Sizing

This document summarizes the technical evaluation of an Altosonic 5 flow meter. It includes specifications for the meter such as its size, material, pressure and temperature ratings, accuracy, and pressure loss calculations. It also notes that the meter will be calibrated according to OIML-R117 standards at Euroloop_Master Meter facility using 6 points and 3 repeats. The meter is rated to measure fuel oil flow rates from 200-1500 cubic meters per hour at pressures from 3-6.5 kg/cm2(g) and temperatures from 60-90 degrees C.

Uploaded by

ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Technical Evaluation ALTOSONIC 5

Quotation no. 999010163-3 Creation date : 28-7-2021


Requisition no. KOG190566 Created by : su
Check date :
Client RASCO Checked by :
End user RASCO Project nr. : 999010163
Location Libya ID nr : 941

V-number_Sensor VN914FA1C3B06001A0003311010011
V-number_Converter VN924L1163A010100003100
V-number_Calibration VN934F000110100

APPLICATION Medium fuel oil

Process conditions Design conditions


Min. Norm. Max. Unit P design 16.5 kg/cm2(g)
Flow range 200 700 1500 m3/h T design 90 °C
Pressure 3 5 6.5 kg/cm2(g) -10 °C
Temperature 60 75 90 °C
Density 0.96 0.96 0.96 SG Phydro 29.0 bar(g)
Viscosity 50 50 50 cSt Full rating @ 20°C / 68°F

Single Liquid Visc. @ Kinematic Visc. Temperature 1 Ref


2 Ref

Sizing Tag no. SN


Meter ALTOSONIC 5 7+1 Velocity Pipe line
Min. 1.10 m/s
No. of items 4
Norm 3.80 m/s
Size 10 inch
Max. 8.20 m/s
Class 150 #
Measuring section
Facing RF
Min. 1.70 m/s
Schedule STD
Norm 5.90 m/s
Material 2.2 Stainless Steel
Max. 12.70 m/s
D connect 254.5 mm
D inside 204.0 mm Kinematic viscosity
Length 900 mm Min. 50.0 cSt
Weight 230 kg Max. 50.0 cSt
Reynolds
Min. 5560
Studbolts 24 Max. 41697
Size 22.2 mm Accuracy
Length 115 mm +/- 0.15 %

Title : Altosonic 5 Evaluation


V1.4 R210517 L200403 21-7-2021 14:03:50 29-7-2021 15:15:47 Dep : CT_products
V1.0 R20180101 C1.1 R20190905 CT044 NLD1FILEMAK CT059 NLD1FILEMAK Revision : 01
Date rev : 20210301
Author : Ztn
Printed: 29-7-2021
Page: 1
Technical Evaluation ALTOSONIC 5
Quotation no. 999010163-3 Creation date : 28-7-2021
Requisition no. KOG190566 Created by : su
Check date :
Client RASCO Checked by :
End user RASCO Project nr. : 999010163
Location Libya ID nr : 941

Pressure loss

7.1 ° 7.1 °

α α
d1 d3 d1 d5 d1 d3
V1 d3 V3 V5
305.3 254.5 254.5 204.0 254.5 254.5 305.3

203 2544.6 900 1272.3 203


Total Length Total Length Total Length

Ploss Reducer FC 0.0000 Ploss Outlet 0.0094


Flow actual Q 700 m3/h
Ploss Reducer 0.0000 Ploss Straightner Outlet 0.0000
ρ
Density 959.1 kg/m3
Ploss Straightner Inlet 0.1213 Ploss Expander 0.0011
Kinematic viscosityυ 50.0 [cSt]
Ploss Inlet 0.0188 Ploss Expander FC 0.0000
Dynamic viscosity μ 47.95 [cP]
Ploss meter 0.0301 Ploss Total 0.1915 [bar]

CALIBRATION
Facility No. of points No. of repeats Calibration procedure
Euroloop_Master Meter 6 Points 3 repeats OIML-R117 class 0.3 (6p x 3r)

Title : Altosonic 5 Evaluation


V1.4 R210517 L200403 21-7-2021 14:03:50 29-7-2021 15:15:47 Dep : CT_products
V1.0 R20180101 C1.1 R20190905 CT044 NLD1FILEMAK CT059 NLD1FILEMAK Revision : 01
Date rev : 20210301
Author : Ztn
Printed: 29-7-2021
Page: 2
Technical Evaluation ALTOSONIC 5
Quotation no. 999010163-3 Creation date : 28-7-2021
Requisition no. KOG190566 Created by : su
Check date :
Client RASCO Checked by :
End user RASCO Project nr. : 999010163
Location Libya ID nr : 941

CONFIGURATION

V-number_Sensor V-number_Converter
VN914FA1C3B06001A000331101001 VN924L1163A010100003100

Size F DN 250 / 10 " Type L R - IP66 (Remote without display)


Class A ASME B 16.5 / 150 lb RF Power Supply 1 24 V DC (12-24 V)

Approval 1 ATEX Ex zone 1 (Europe) Approval 1 ATEX Ex zone 1 [d] (Europe)

Cable connection C M20 x 1,5 Cable connection 6 M20 x 1,5


Instruction/program 3 English
Converter model 3 A 5 Converter R (Remote)
CT-certification A OIML R117, Class 0.3
Material B SS 316 L - butt weld vers.
Process diagnostics 0 Standard, non tropicalized
Bore 0 Standard, reduced bore (RB)
Housing 1 Standard, aluminum
Schedule 6 40s / STD
Private label 0 KROHNE standard version
Version 0 STD (Standard Meter)
Communication 1 Basic IO
Private label 0 KROHNE standard version
I/O module 1 0 Without carrier, no module possible
Coating 1 KROHNE std., grey
I/O module 2 0 Without carrier, no module possible
CT-certification A OIML R117, Class 0.3 Ambient temperature 0 Standard
Construction 0 Std. documentation, uni-direct-forward. Tagplate 0 Standard, without
QA / QC 0 Standard Manual 3 English
IP-Class 0 IP 66 | NEMA 4X Cable gland material 1 Brass
Name plate 3 316|1.4401 tagplate ( 67 x 25 mm) Destination 0 Standard

Manual 3 English Local display 0 Standard, without

Design code 1 ASME B31.3


Inspection code 1 ASME-V / API 1104 PED 2014/68/EU V-number_Calibration
Extended Dnom 0 Standard VN934F000110100
Cable gland material 1 Brass
Cable length 0 Remote - 5 m | 15 ft, Compact - none Size F DN 250 / 10 "
Destination 0 Standard Calibration Facility 0 Euroloop Liquid - Master meters
Hydrotest witnessing 1 KROHNE-QA Calibration procedure 0 OIML-R117 class 0.3 (6p x 3r)
Characterization 1 1 liquid Flow direction 0 Uni-directional
Calibration products 1 1 Hydrocarbon

Calibration Points 1 6 Points


Repeats 0 3 repeats
Cleaning 1 Euroloop Liquid - cleaning
CAL witnessing 0 Not applicable, without
Extended Dnom 0 Standard

Title : Altosonic 5 Evaluation


V1.4 R210517 L200403 21-7-2021 14:03:50 29-7-2021 15:15:47 Dep : CT_products
V1.0 R20180101 C1.1 R20190905 CT044 NLD1FILEMAK CT059 NLD1FILEMAK Revision : 01
Date rev : 20210301
Author : Ztn
Printed: 29-7-2021
Page: 3
Technical Evaluation ALTOSONIC 5
Quotation no. 999010163-3 Creation date : 28-7-2021
Requisition no. KOG190566 Created by : su
Check date :
Client RASCO Checked by :
End user RASCO Project nr. : 999010163
Location Libya ID nr : 941

General arrangement ST
8.1 L11xx

1.1 L10xx L10xx 1.2


2.1 L11xx L11xx 2.2

3.1 L11xx L11xx 3.2

510 mm
4.1 L11xx L11xx 4.2

5.1 L11xx L11xx 5.2

6.1 L11xx L11xx 6.2

7.1 L10xx L10xx 7.2

254,46 mm
8.2 L11xx
450 mm

Length 900 mm
Weight 230 kg

All dimensions are provided as indication. They can vary slightly with different schedule sizes.