Switched PDU with

Monitoring

VT604 / Switched PDU with 4 outlets


Device is used for load management and allows to switch on/off or reboot up
to 4 outlets. It has built-in temperature sensor, can connect 2 additional
sensors, 2 dry contacts, two 12V devices, GSM modem & USB-сam.

Compatible with all VT sensors.


Infrastructure monitoring system “VT604 / Switched PDU” brochure

Overview

VT604 has 4 switched outlets. They can be controlled individually or as a group using web interface. Outlets
can also be managed with predefined logic. “VT604” is also used for infrastructure environment monitoring
(room temperature, humidity, leakage, voltage, vibration, access, smoke, ...), notifications (SMS, SNMP,
E-mail, Video, Alarm beacons) and control of cabinets, data centers, outdoor cabinets, telecom sites and
other mission critical facilities.

HARDWARE: SOFTWARE:

• Inlets C14 (240V, 10A) • Web interface

• 4 outlets C13 (110-240 VAC, 50/60Hz) • Outlets switching panel in interface


• Virtual sensors & elements: Group, E-mail,
• CAN port for digital sensors
SNMP trap, SNMP Get, SMS, IP cams, PINGs,
• 2 AutoSense RJ-12 ports for sensors
Triggers, Timers
• 2 dry contact inputs • SNMP traps, SMS & E-mail notifications
• USB port for web camera or for USB flash for • Supports SNMP v.1, v.2c, v.3
saving logs • Notifications: E-mail, SMS, Syslog, Event log,
• Two 12V 0.25A output relays SNMP Trap, SNMP Get

• 100 Mbit Ethernet port • Configurable embedded logic


• Sensor graphing
• LEDs: for 4 outlets
• Multilanguage support
• LEDs: system status, relays, errors & CAN
• User Access and Permissions
• Onboard temperature sensor (1%)
• Internal GSM modem extension slot (GSM OTHER:
modem is ordered separately) • 2 Year warranty
• Manufactured in E.U.

02
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Technical Data

“VT604” has a Linux OS running an 300 MHz ARM CPU. It is TCP / IP compliant and runs lighttpd web
server including HTTPS (SSL), SMTP, DHCP, SNMP, FTP, Syslog, Radius. Web interface is mobile ready and
runs on HTML5.

Multilanguage interface

Web interface is has a multilanguage GUI and can be easily customized at request.

SNMP

All SNMP functions including SNMP v.1, v.2c, v.3 are supported.

Also supports CAN bus commands, easy to configure CAN data to SNMP gateway.

“VT604” has a Built-in Watchdog timer with NTP synchronisation.

SNMP Get function supported.

CAN bus connection

Up to 8 CAN devices can be connected to VT604. When plugged in, user needs to configure CAN units, and
save configuration, then after reboot or energy lost, the system automatically reconfigures sensors.
Using such CAN bus with max length 300 m, it is possible to connect up to 30 different sensor elements to
a single monitoring unit.

5-level sensor thresholds

Sensors with 5-level thresholds allows direct connection to the SCADA system. The thresholds are usually: very low, low,
normal, warning and alarm. Sensor levels can be inverted.

Processor: ARM926EJ 300 MHz Ethernet 10/100 Mbit port


OS: Linux 3.10.101 Built-in clock with time synchronization
ROM: 512 Mbit NAND Flash RADIUS access with Login
RAM: 64 Mb Device Management: Web, SNMP, manually via SMS
Operating temperature: 0 to 60 °C Built-in watchdog timer
Storage temperature: –25 to 85 °C Alert types: FTP, Syslog, SMTP or SNMP, SMS (GSM modem is
Operating humidity: 0 to 90 %, non-condensing ordered separately)
Storage humidity: 0 to 95 %, non-condensing Network protocols: DHCP, HTTP, HTTPS, SNMP, SMTP, SSL, FTP,
Syslog, CAN, Get SNMP, TLS

03
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Outlet managememt

VT604 has 4 switched outlets. They can be controlled individually or as a group using web interface. Outlets
can also be managed with predefined logic.

Sensor Graphing

GUI integrates and displays graphs of all sensor data. The individual graph (seconds, minutes, hours, days)
for each sensor type can be selected. RRD tool is used to build an embedded database of sensor data.
This data can be accessed in interface, or downloaded to Syslog or to FTP or saved on SD card or USB flash.
You can compare sensor data using a Multiplot by plotting a few sensor data along each other.

04
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Configurable logic

Web interface allows you to set up logic rules for alerts, notifications & actions to avoid unplanned downtime
due to overdrawn circuits.

Connect up to 4 IP Cameras

“VT604” can display pictures from a maximum of four IP cameras simultaneously in several sizes, up to
640x480 pixels resolution.

05
Infrastructure monitoring system “VT604 / Switched PDU” brochure

SNMP based NMS software

NMS monitors your network 24/7 to timely alert you to issues before they become emergencies. Allow you to
achieve instant awareness of IT infrastructure problems, so downtime doesn’t adversely affect your business.
Usual NMS software offers complete monitoring and alerting for servers, switches, applications, and services.
By integrating Vutlan’s environmental monitoring systems and PDUs, you achieve a complete control over
your IT infrastructure in one place.

All Vutlan’s master systems support SNMP v.1, v.2c, v.3. Required MIB files are included with all systems.
Some of the supported NMS systems are listed below, for a full list please visit our website.

HP Network Node Manager ServersCheck

IBM Tivoli Zabbix

PRTG Network Monitor Nagios

Open NMS Cacti

Monitorix and many more

Infrastructure monitoring program (Nagios)

We have preconfigured Nagios to automatically work with any of our products. You can download and install
Vutlan plugin directly into Nagios or download a disk image that includes VirtualBox, CentOS 6.5, Nagios
3.5.1 and Vutlan plugin preinstalled into Nagios.

06
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Scalability

Following sensors and devices can be connected to “VT604 / Switched PDU”:

CAN sensors Description


VT408 / Extension unit Allows to increase the number of sensors connected to any monitoring unit. Adds 8 analog sensors.
The unit has all possibilities for rack control, PIR sensor for door control, 2 dry contacts, temperature
VT430 / Rack control unit
and humidity sensors.
Allows to increase the number of dry contacts connected to any Vutlan monitoring unit. Adds 32 or
VT440 / Dry contacts unit
64 dry contacts.
VT460 / Smoke, humidity &
Monitors occurrence of smoke, temperature and humidity inside the building.
temperature sensor
VT470 / PIR, vibration & Sensor is needed for control of movement over an infra-red range and measurement of temperature
temperature sensor and vibration indoors.
VT490 / Humidity &
Monitors temperature and humidity inside the building.
temperature sensor

Embedded modules Description


(ordered separately)
VT700 / GSM modem Adds ability to receive and send SMS for control and notifications.

Analog sensors Description


Switchable contact. Can be used together with equipment, for example for switching ON/OFF air
VT11 / Dry contact OUT
conditioners.
Converter of current loop 4-20mA is used for measurement of constant current on 4-20mA from dif-
VT420 / Converter 4-20mA ferent sensors and converting data into format of IP monitoring system. The system interface allows
you to assign the sensor and to introduce the function data conversion.
VT500 / Temperature sensor For measurement of temperature indoors.
VT501 / Outdoor temperature sensor For measurement of temperature outdoors.
VT510 / Humidity sensor Measures relative humidity 10-95% indoors with relative accuracy 5%.
VT520 / AC voltage monitor Measures AC 110-240V
VT530 / Access sensor Sensor controls the status of a door or a window: opened, closed.
VT540 / Vibration sensor Detects vibration, allows daisy chain connection
VT560 / Smoke detector Detector detects smoke indoors, allows daisy chain connection
VT570 / PIR sensor Infrared motion sensor
VT590 / Leak sensor When water is in contact with the metal cores, the sensor indicates the emergence of moisture.
VT591 / Water leak cable sensor When water is in contact with detection cable, sensor indicates the emergence of moisture.

AC / DC meters Description
Transducer is used together with HOS-100Q1 dc Hall current sensors and converting data into
VT406 / HOS sensor transducer
format of IP monitoring system.
Transducer is used together with HAT-100Q1 current transducer and transferring data into a moni-
VT407 / HAT sensor transducer
toring system.

VT410 / DC voltage monitor DC monitor is used for measurement of DC voltage up to 60V and converting data into format of IP
monitoring system.
VT520 / AC voltage monitor Sensor is needed for measurement of AC 110-240V

Accessories (ordered separately) Description


VT112 / Rotatable mounting brackets Package includes 2 rotary brackets which allow to mount monitoring systems at an angle.

Please refer to www.vutlan.com for a complete list of Vutlan products. Products may change over time.
07
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Security, Notifications and Alarms

“VT604” authorization is going through the Radius protocols, that highly increases resistance to forced at-
tacks.

Notifications and alarms can be configured in “Logic menu” of web-interface using the states of sensors, tim-
ers, triggers and so on. In case of a problems the notification scheme can alert user via email, SMS or SNMP,
automatically send pictures and data.

The complete status of the unit and / or sensors can be taken through HTTP, SMS, or SNMP, saved on FTP
and Syslog servers or on installed SD card.

Virtual elements

• E-mail, SNMP trap, SMS notifications


• Timers
• Triggers
• Pings
• IP Cams
• Groups
• Get SNMP

Support and Warranty

• Full Two Year Global Warranty


• Unlimited Lifetime Support
• Free Firmware Updates
• Full, Easy to Follow Documentation

08
Infrastructure monitoring system “VT604 / Switched PDU” brochure

VT604 Features List

• Receive notifications of anomalous events via email, SMS / MMS, SNMP traps.
• Integrates with network management systems via SNMP v.1 and Encrypted SNMP v.3.
• Uses Linux operating system for maximum stability and flexibility.
• Web GUI for PC, smartphones and tablets; free firmware upgrades and utilities.
• Monitor up to 30 different sensors.
• Compatible with full range of different third-party sensors.
• Embedded web server displays sensor information and live video from connected cameras.

Specifications

Dimensions Inputs Operating Environment


Size 440 x 44.45 (1U) x 79 mm 1 inlets Temperature: Min. -10° C - Max.80° C
19” 1U Rack mount CAN open port Humidity : Min. 5%, Max. 80% (Non-
Weight 1. 5 Kg 2 dry contact inputs Condensing)

2 RJ-12 sensor ports


Ethernet 10/100 Mbit/s Expansion Devices
Power Requirements
VT700 / GSM modem
230V / 10A
Network Interface
Ethernet 10/100 Mbit/s Other
Mounting
USB (for USB Camera or or USB Flash for
19” 1U Rack mount saving logs)
Status Indicators
Desktop (rubber feet included) 10A fuse
Accessory “VT112 / Rotatable brackets” LEDs: status of 4 outlets
(allow wall mounting) LEDs: CAN, Power, Relays and Error
Sensors

Power Consumption Temperature sensor (1%)


Outputs
Power supply voltage sensor (1%)
10 W 4 C13 outlets
2 * 12V 0.25A relay outputs
Components
Accessories GSM SMA

VT112 / Rotatable mounting brackets


Manufactured in EU.

09
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Dimensions & Order options

Dimensions (VT604)

Order options (ordered separately)

10
Infrastructure monitoring system “VT604 / Switched PDU” brochure

Connection example

Basic package includes

• 19” rack brackets - 2 pcs • Terminal plug 3 pins, 3.81 mm - 1 pcs


• M3 x 8 Phillips flat-head screws - 6 pcs • Terminal plug 3 pins, 3.5 mm - 1 pcs
• EU Schuko C13 0.5 мм2 230V 10A cable • Short description and connection guide
• RJ-45 1m patch cable • Warranty card
• Self-adhesive rubber foot - 4 pcs

11
28 branches
33
19 countries

www.vutlan.com

Data center & Telecom environment


monitoring and control
Vutlan s.r.o.
43, ul. Svornosti, 82106 Bratislava, Slovak Republic, EU
Tel.: +421 2 4524 1440
Mob.: +421 915 153 817, +421 908 399 047
E-mail: [email protected]
Skype: sky-control.sk, skycontrol.com
www.vutlan.com

You might also like