Growatt MID 612KTL3 XL Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MID6~12KTL3-XL

· Max.efficiency 98.5%

· 40% compact and lighter

· Dual MPP trackers

· Supports export control

· Touch key and OLED display

· Type II SPD on AC and DC side

www.ginverter.com
Datasheet MID6KTL3-XL MID8KTL3-XL MID10KTL3-XL MID11KTL3-XL MID12KTL3-XL

Input Data
Max. recommended PV power
(for module STC) 7800W 10400W 13000W 13000W 15600W

Max. DC voltage 800V 800V 800V 800V 800V

Initial voltage 250V 250V 250V 250V 250V


Nominal voltage 360V 360V 360V 360V 360V

MPPT voltage range 160-800V 160-800V 160-800V 160-800V 160-800V

Full load voltage 280-650V 280-650V 280-650V 280-650V 280-650V

No. of independent MPPT 2 2 2 2 2

No. of PV strings per MPPT 2 2 2 2 2


Max. input current per MPPT 25A 25A 25A 25A 25A
Max. short-circuit current per MPPT 32A 32A 32A 32A 32A

Output (AC)
AC nominal power 6000W 8000W 10000W 11000W 12000W
Max. AC apparent power 6600VA 8800VA 11100VA 12100VA 13300VA
Nominal AC voltage/range 133V/230V 133V/230V 133V/230V 133V/230V 133V/230V

AC grid frequency; range 50/60 Hz; 47.5~52 Hz/55-65 Hz 50/60 Hz; 47.5~52 Hz/55-65 Hz 50/60 Hz; 47.5~52 Hz/55-65 Hz 50/60 Hz; 47.5~52 Hz/55-65 Hz 50/60 Hz; 47.5~52 Hz/55-65 Hz
Max. output current 16.5A 22.1A 27.8A 30.3A 33.3A
Powerfactor @Nominal power >0.99 >0.99 >0.99 >0.99 >0.99
Power factor 0.8 leading - 0.8 lagging 0.8 leading - 0.8 lagging 0.8 leading - 0.8 lagging 0.8 leading - 0.8 lagging 0.8 leading - 0.8 lagging

THDi <3% <3% <3% <3% <3%


AC grid connection type 3W+PE/3W+N+PE 3W+PE/3W+N+PE 3W+PE/3W+N+PE 3W+PE/3W+N+PE 3W+PE/3W+N+PE

Efficiency
Max.efficiency 98.50% 98.50% 98.50% 98.50% 98.50%
Euro - eta 98.10% 98.10% 98.10% 98.10% 98.10%

Protection Devices
DC reverse polarity protection yes yes yes yes yes

DC Switch yes yes yes yes yes


DC Surge protection TypeII TypeII TypeII TypeII TypeII

Insulation resistance monitoring yes yes yes yes yes

AC surge protection TypeII TypeII TypeII TypeII TypeII

Output short circuit protection yes yes yes yes yes

Ground fault monitoring yes yes yes yes yes


Grid monitoring yes yes yes yes yes

Anti-islanding protection yes yes yes yes yes


Residual-current monitoring unit yes yes yes yes yes

String fault monitoring opt opt opt opt opt

AFCI protection opt opt opt opt opt

General Data
Dimensions (W / H / D) in mm 525/395/222 525/395/222 525/395/222 525/395/222 525/395/222
Weight 23kg 23kg 23kg 23kg 23kg
Operating temperature range -25 °C ... +60 °C -25 °C ... +60 °C -25 °C ... +60 °C -25 °C ... +60 °C -25 °C ... +60 °C
Noise emission (typical) ≤40 dB(A) ≤40 dB(A) ≤40 dB(A) ≤40 dB(A) ≤40 dB(A)
Self-Consumption (night) <1W <1W <1W <1W <1W
Topology Transformerless Transformerless Transformerless Transformerless Transformerless
Cooling Narural convection Narural convection Narural convection Narural convection Narural convection
Environmental Protection Rating IP65 IP65 IP65 IP65 IP65
Altitude 4000m 4000m 4000m 4000m 4000m
Relative Humidity 0~100% 0~100% 0~100% 0~100% 0~100%
DC connection H4/MC4(opt) H4/MC4(opt) H4/MC4(opt) H4/MC4(opt) H4/MC4(opt)
AC connection Cable gland+OT terminal Cable gland+OT terminal Cable gland+OT terminal Cable gland+OT terminal Cable gland+OT terminal

Features
Display OLED+LED WIFI+APP OLED+LED WIFI+APP OLED+LED WIFI+APP OLED+LED WIFI+APP OLED+LED WIFI+APP
Interfaces: USB/RS485/WIFI/GPRS/4G yes/yes/opt/opt/opt yes/yes/opt/opt/opt yes/yes/opt/opt/opt yes/yes/opt/opt/opt yes/yes/opt/opt/opt

CE, EN50549, VDE-AR-N4105, CEI 0-21, CEI 0-16, IEC 62116, IEC 61727, G99, AS4777

GROWATT NEW ENERGY TECHNOLOGY Co.,LTD A: No.28 Guangmming Road, Longteng Community, Shiyan, Baoan District, Shenzhen, P.R.China.