Contents
Front Cover Contents PTFE - The Optimum Choice For Hose Linings Aflex Hose and Bioflex Bioflex Hose Design and Comparative Properties Bioflex Hose - Special Test Programs Bioflex Temperatures, Pressures & Flow Rates Bioflex Sizes, Grades, Bend Radius and Dimensions Bioflex Sizes, Grades, Pressure Ratings and Weights Bioflex Special Usage Conditions Quality Assurance Certification & Approvals and Hose Testing How to Order Bioflex Bioflex Part Number System HOSE Bioflex Hose Liners Bioflex Hose Braids Bioflex Rubber Covers Bioflex External Protection Systems FLANGE FITTINGS Flange Fittings, Non-Lined Flange Fittings, PTFE Lined CAM AND GROOVE FITTINGS (CAMLOCKS) Female Cam & Groove Fittings, PTFE Lined and Not Lined Male Cam & Groove Fittings, PTFE Lined and Not Lined and Cam Male-to-Flange Adaptors, PTFE Lined SANITARY (TRICLOVER) FITTINGS Mini Sanitary & Sanitary Triclover Fittings, PTFE Lined Sanitary Triclover Fittings, PTFE Lined and Beaded Mini Sanitary & Sanitary Triclover Fittings, Not Lined 90 Elbow Sanitary Triclover Fittings, Not Lined HYGIENIC FITTINGS (EUROPEAN) DIN 11851 Male & Female Fittings, PTFE Lined SMS and RJT Female Fittings, PTFE Lined BSP NPT & JIC THREADED FITTINGS (Not Lined) , NPT & BSPT Fixed Male and NPT Fixed Female Fittings BSP 60 Cone Seat Female Fittings and Lug-Type Female Fittings 37 JIC Female Fittings & Adaptors PTFE Dip Pipes PTFE Dip Pipes, Straight or 90 Elbow 90ELBOW FITTINGS 90 Elbow Fittings, PTFE Lined and Non-Lined HEAT JACKETED HOSE ASSEMBLIES Steam Heated Hose Assemblies (CH Grade) Electrically Trace Heated Hose Assemblies (ETH Grade) BIOFLEX STANDARD AND PURETAG LABELLING & COLOUR CODING CORRECT HOSE CONFIGURATION & LENGTH CALCULATIONS - for Bend Radius - for Abrasion & Torque - for Length Calculation CONDITIONS OF SALE Page 37 Page 38 Page 39 Page 40 Page 34 Page 35 Page 36 Page 33 Page 32 Page 29 Page 30 Page 31 Page 27 Page 28 Page 23 Page 24 Page 25 Page 26 Page 21 Page 22 Page 19 Page 20 Page 15 Page 16 Page 17 Page 18 Page 1 Page 2 Page 3 Page 4 Page 5 Pages 6 & 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14

Page 2

PTFE - The Optimum Choice For Hose Linings


PTFE, or Polytetrafluoroethylene, comprises long-chain

Section from a PTFE Molecule, 16 Angstrom Units long.

molecules of carbon atoms, each linked to two fluorine atoms. The fluorine atoms provide a helical spiral which surrounds the carbon chain and protects it. It is this structure which creates the unique properties for which PTFE is well-known.

Excellent Chemical Resistance


PTFE is renowned as the most chemically resistant material known. Only a very few, very unusual substances and conditions can affect it, like Fluorine gas at high temperature and pressure and liquid, boiling sodium metal. PTFE lined hoses can therefore be used for a wider variety of chemicals than any other hose type, making it the ideal choice for very corrosive chemical applications and multiproduct applications.

= Fluorine Atom = Carbon Atom

Non-Stick Surface
The use of PTFE as a surface for cookware products has demonstrated to the world how easily cleanable PTFE surfaces are. This means that PTFE lined hoses can be purged 100% clean more quickly, easily and reliably than any other type of hose.

Excellent Temperature Range


The cookware application also demonstrates another of PTFEs many attributes - temperature resistance. PTFE itself can be used as a hose liner at temperatures from -150C up to +260C, dependent upon the hose design and the application conditions. This is the widest temperature range of any rubber or plastic hose lining material.

Very High Electrical Resistance


Most aerospace electrical wiring has a PTFE cover, due to the excellent electrical resistance of PTFE. This property is, however, a disadvantage in some hose applications where there is a risk of developing an electrostatic charge inside the hose bore. Aflex Hose have developed a noncontaminant, FDA and USP Class VI compliant solution to this problem.

Hose Design
The only issue with PTFE as a hose lining material is the best way it can be integrated in to the hose design. This is where Aflex Hose have a proven record of success over the last 30 years. Page 3

Aflex Hose and BIOFLEX

The Worlds Leading Manufacturer of PTFE Flexible Hose


Aflex Hose, founded in 1973, pioneered the concept of PTFE lined flexible hose for the transfer of process fluids more than 30 years ago. Corroflon convoluted PTFE hose and other types of PTFE hose, manufactured and supplied by Aflex, are used by major Chemical, Pharmaceutical and Food companies worldwide. Over the years, hundreds of thousands of custom-built hoses have been designed and built to cope with the most difficult of operating conditions, and Aflex have continuously developed and expanded their product range having pioneered and introduced Antistatic hose, Polypropylene Braided hose and many other innovations in response to customer demands.

In 2001, Aflex fulfilled the most stringent demand yet. Customers, worldwide, had always asked for the ultimate PTFE lined flexible hose... one product which incorporates the advantages of both convoluted and smoothbore designs. A product which is sufficiently flexible, like convoluted, yet which retains the advantages offered by smoothbore, like fast flow rate and cleanability. After years of painstaking research and development, Aflex launched such a hose ...

Conventional Convoluted PTFE Liner

Bioflex.

Bioflex is a smooth bore, highly flexible, PTFE lined hose. Its design overcomes the disadvantages of conventional smooth bore and convoluted PTFE flexible hose designs, dramatically improving on many of their individual technical performance parameters. The key feature of Bioflex PTFE hose is the PTFE liner design, which comprises integral rib sections which support the tube against kinking, vacuum and pressure, and highly
Web Section Rib Section

compressed web sections which give a smoothbore inner surface and excellent flexibility. Another feature is the integral PTFE lined and flared end fitting design (see next page) which is available for all the standard end fittings on Bioflex Hose Assemblies.

Bioflex PTFE Liner


This provides clean, full-bore flow through the end fitting without any entrapment points - unlike conventional fittings, which introduce a bore restriction, also a crevice at the end of the fitting tail. This PTFE lining also protects the end fitting from any corrosive media passing through the hose bore. Today, Bioflex has become the established standard in process fluids applications all over the world, and continues to be introduced into new applications every day.

Bioflex is a Patent Protected Product

Page 4

Bioflex Hose-Design and Comparative Properties


Bioflex Hose Design Options
Bioflex Hose Grades are ade up by combining the Design Options, which are designated by 2 or 3 letters as shown below, and fully described on the indicated pages. For example, Bioflex AS, PB, SG defines a hose with an Antistatic PTFE liner (AS) and a Polypropylene braid (PB) and an outer Safegard (SG) spiral HDPE protection sleeve. PTFE Liner Tube Options - GP or AS - Page 15 Braid Options - TO, SS, HB, PB, KYB - Page 16 External Rubber Cover Options - RC, SI, FP and RC-300 - Page 17 External Protection Options - KR, SR, SG and PC - Page 18

BIOFLEX GP, SS WITH A PTFE LINED FLANGE FITTING


Stainless Steel Spigot

Stainless Steel Wire Braid (SS)

Ferrule, crimped to secure braid to spigot

Swivelling Flange

Bioflex in Comparison with Convoluted PTFE Hose


Hygienic Cleanability - much better, due to no internal convolutions. Flow Rates - more than 2x higher. Pressure Ratings - more than 1.5x higher. Gas Permeation Resistance - more than 3x better. Self Draining - 100% self draining when at an angle (The Internal Convolutions in Convoluted hose retain fluid).

Bioflex in Comparison with Conventional Smoothbore FEP, PFA or PTFE Lined Rubber Hose
No Adhesives - No toxic adhesives used in the Bioflex construction, eliminating the possibilities of Process Fluid contamination in service. Flexibility - Much better flexibility, particularly sizes 1 and above.

Natural PTFE liner tube (GP)extended through the end fitting, then flared out to form the sealing face

Bioflex in Comparison with Silicone Rubber Hose


Hygienic Cleanability - much better, due to the non-stick PTFE Liner. Chemical Resistance - considerably improved, particularly to strong oxidising acids and bases. Temperature & Pressure Ratings - much higher temperature and pressure capability. Steam Resistance - permanently resistant to steam sterilising (unlike silicone hose, which has a limited life).
Page 5

Bioflex PTFE liner tube: - externally convoluted - smooth bore, with slight ripples - internal surface finish is mirror smooth, generated by hot polishing during manufacture

Bioflex Hose - Special Test Programs (1)


Bioflex has been designed to fulfil the most demanding of customer expectations and, as such, has been subjected to a highly complex and rigorous Proof Testing Programme in comparison with competitive hose products.

Test No. 1. The Rolling U Test.


Bioflex samples were run side by side with competitors products, including smoothbore FEP PTFE or PFA lined Rubber hose products, and , also smooth flex products, on a Rolling U test rig.

The 1 bore samples were Rolled at the minimum bend radius and at the maximum working pressure quoted for the competitors product. Results were as follows:

Rubber Covered Bioflex Hose - 1,500,000 cycles, no failure. - No leakage occurred, so test discontinued. No signs of damage, or wear. Competitors smoothbore FEP lined Rubber Covered Hose - 9,149 cycles to failure. - Hose leakage caused by severe failure of the hose liner, breakage of the helix wire and damaged rubber and braid. Competitors convoluted smooth flex type hose, SS Braid - 7,151 cycles to failure. - Hose leakage caused by very severe failure of the hose liner and braid components.

These remarkable results confirm the claims made by Aflex, that Bioflex is the best designed, toughest and most reliable PTFE lined hose product available today.

Page 6

Bioflex Hose - Special Test Programs (2)

Test No. 2. The Permeability Test.


Fixed lengths of Bioflex were pressurised to 30 Bar with Helium Gas, and compared with samples of standard convoluted PTFE hose.

Results
Bioflex has more than 2.5 x the permeation resistance of standard convoluted hose. Under identical conditions, the permeation levels were: 1 Bioflex = 138 millilitres of helium per metre per hour

1 Convoluted = 371 millilitres of helium per metre per hour The permeability, or diffusion of gases and some fluids through PTFE is a problem in certain, very specific applications. Bioflex hose offers significant advantages in such applications.

Test No. 3. The Flow Rate Test.


The test apparatus illustrated opposite was used to measure the flow rate of Bioflex, both in a straight configuration and coiled to its Minimum Bend Radius. The test medium was water.

Results
Comparisons were made with samples of standard convoluted hose with the same diameter on the inside of the convolutions as the Bioflex inside diameter. These show that Bioflex is capable of delivering 2 - 3 times the flow rate of convoluted hose, in both the hose configurations. Additional tests have shown that the flow rate through a Bioflex hose is actually greater than that of a convoluted hose which is one size larger. For example, 11/2 Bioflex has a higher flow rate than 2 convoluted hose. It is therefore possible to use a smaller Bioflex hose, fitted with full size end fittings, to replace a convoluted hose more effectively, and more economically! This remarkable improvement is due to the fact that the turbulent flow created by the convolutions in the standard product is virtually eliminated by the much smoother bore of Bioflex.

Page 7

Bioflex Specifications. Temperatures, Pressures & Flow Rates


Temperature & MWP Graph for Bioflex GP SS and AS, SS ,

Temperature vs Pressure
Due to its extremely strong construction, Bioflex has outstanding resistance to temperature and pressure, much higher than that of conventional convoluted PTFE lined hose.

MAXIMUM WORKING PRESSURE IN BARS

Hose Size: 3/ 8
1/ 2 5/ 8 3/ 4 7/ 8

Maximum Working Pressure (MWP) Variation with Temperature:


Hose with SS Braid as per Graph. Hose with PB Braid, pressure as listed (Page 10) from -30C to +80C and 50% less from 80C to 100C. Hose with RC, FP and SI grades as per Graph, BUT only within the temperature range for the particular grade of rubber cover, as given below.

1 1 1/ 4 1 3/ 8 /1 1 / 2 1 7/ 8 2

Maximum Operating Temperatures (Internal Fluid Only):


SS PB SS,RC & SS, FP SS, SI KYB -70C -30C -40C -40C -40C to to to to to +260C +100C +140C +200C +120C

TEMPERATURE IN DEGREES CENTIGRADE

Temperature vs Vacuum
All sizes of Bioflex GP SS and AS, SS are usable at full vacuum up to , 130C. Above this, the vacuum resistance should be reduced 1% for every degree above 130C. Other hose grades the same, BUT ONLY within the temperature limits for the particular hose grade. All sizes of Bioflex GP TO and AS, TO are fully vacuum resistant up to , 100C

(Subtract 20C from the above maximum temperature limits if the temperature is external to the hose).

Flow Rates
In practice, flow rates will vary with hose flexing, fluid viscosity, end fitting design and other parameters, but Bioflex hose flow rates are always around 2 times better than convoluted PTFE hose, when comparing hose assemblies with PTFE lined (non bore-restricted) end fittings. Bioflex Hose - Flow Rate Calculation If it is required to determine the flow rate of a particular hose assembly, or if it is required to determine the pressure required to generate a certain flow rate, then this can sometimes be approximately calculated by the Bioflex supplier. It should be noted that calculations can only be made for fluids with a viscosity equal to water, and for hose assemblies with PTFE lined end fittings (no bore restrictions at the ends of the hose). The following information should be given to the supplier: To calculate the Flow Rate in Cubic Metres per Hour: - Pressure in Bars at the Entry into the Hose Assembly - Pressure in Bars at the Exit from the Hose Assembly

- The hose configuration (roughly straight, or 33% Bends, or 66% Bends, or 100% Tightly Coiled) OR To Calculate the Pressure Drop in bars over the length of the Hose Assembly: - Required Flow Rate in Cubic Metres per Hour - The hose configuration (roughly straight, or 33% Bends. or 66% Bends, or 100% Tightly Coiled)

>

(Subtracted to calculate Pressure Drop over the Hose Length)

Non-Whistling
The whistling noise created by turbulent flow when steam or other gases are passed through a convoluted hose is completely eliminated when using Bioflex.

Page 8

Bioflex Sizes, Grades, Bend Radius and Dimensions


Nominal Hose Bore Size in
3

Actual Bore Size in


3

Bioflex Grade (Braid & Cover)

O/D of Tube, Braid or Rubber in mm


12.0 12.8 17.4 15.5 16.6 19.5 21.0 21.0 17.5 19.4 20.6 23.3 25.0 25.0 21.5 23.2 24.5 27.9 30.4 30.4 26.0 27.0 28.2 32.0 33.2 33.2 29.7 31.0 32.3 37.7 37.7 37.7 33.4 37.3 39.5 44.3 44.3 44.5 39.7 41.2 43.1 47.8 48.1 48.1 42.9 45.0 47.0 50.8 52.0 52.0 47.7 55.2 57.1 62.0 62.1 62.1 57.3 59.1 61.0 66.0 66.0 66.0 61.7

Minimum Bend Radius in


13/8 3 /4 3 /4 23/8 11/2 11/2 11/2 11/2 11/2 21/2 13/4 13/4 13/4 13/4 21/2 3 2 2 2 2 3 31/2 23/8 23/8 23/8 23/8 31/2 43/4 23/4 23/4 23/4 23/4 43/4 51/2 4 4 4 4 51/2 61/2 43/4 43/4 43/4 43/4 61/4 7 51/2 51/2 51/2 51/2 7 11 71/2 71/2 71/2 71/2 11 12 8 8 8 8 12

*Maximum Continuous Hose Length Ft


60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 56 56 56 56 56 56 43 43 43 36 36 43 33 33 33 26 26 33

mm
10

mm
9.5 TO SS RC TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB

mm
35 19 19 60 38 38 35 35 35 64 45 45 45 45 64 75 50 50 50 50 75 90 60 60 60 60 90 110 70 70 70 70 110 140 100 100 100 100 140 160 120 120 120 120 160 180 140 140 140 140 180 280 190 190 190 190 280 300 200 200 200 200 300

Mtrs
18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 17 17 17 17 17 17 13 13 13 11 11 13 10 10 10 8 8 10

/8

/8

0.47 0.50 0.68 0.60 0.65 0.77 0.83 0.83 0.69 0.76 0.81 0.92 0.98 0.98 0.85 0.91 0.96 1.10 1.20 1.20 1.62 1.06 1.11 1.26 1.31 1.31 1.17 1.22 1.27 1.48 1.47 1.47 1.31 1.47 1.56 1.74 1.75 1.75 1.56 1.62 1.70 1.88 1.90 1.90 1.69 1.77 1.85 2.00 2.05 2.05 1.88 2.17 2,25 2.44 2.45 2.45 2.25 2.33 2.40 2.60 2.60 2.60 2.43

/2

15

/2

12.7

/8

16

/8

16.0

/4

20

/4

19.0

/8

22

/8

22

25

25.4

11/4

32

11/4

32

13/8

35

13/8

34.9

11/2

40

11/2

38

17/8

48

17/8

47.6

50

50.8

*Maximum Continuous Lengths - for sizes from 3/8, 10mm up to 1, 25mm lengths of up to 36 mtrs, 120 ft, can be supplied to special order. Page 9

Bioflex Sizes, Grades, Pressures & Weights


Nominal Hose Bore Size Actual Bore Size Bioflex Grade (Braid & Cover) Maximum Working Pressure of Hose* Bar (N/m2)
TO SS RC TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB TO SS PB RC/FP SI KYB 5 80 80 5 70 35 70 70 10 5 65 33 65 65 10 5 60 30 60 60 10 4 55 27.5 55 55 10 4 50 25 50 50 10 3 45 23 45 45 6 2 40 20 40 40 6 2 40 20 40 40 6 2 35 18 35 35 6 2 30 15 30 30 6

Burst Pressure

Weight per Unit Length

in
3

mm
10

in
3

mm
9.5

psi
72 1160 1160 72 1015 500 1015 1015 145 72 940 480 940 940 145 72 870 440 870 870 145 60 800 400 800 800 145 60 720 360 720 720 145 43 650 330 650 650 87 29 580 290 580 580 87 29 580 290 580 580 87 29 500 250 500 500 87 29 430 215 430 430 87

Bar (N/m2)
20 500 500 20 400 140 400 400 40 20 380 130 380 380 40 20 300 120 300 300 40 16 220 110 220 220 40 16 200 100 200 200 30 12 180 90 180 180 24 8 160 80 160 160 20 8 160 80 160 160 20 8 140 72 140 140 16 8 120 60 120 120 12

psi
290 7200 7200 290 5800 2000 5800 5800 580 290 5500 1900 5500 5500 580 290 4350 1750 4350 4350 580 230 3200 1600 3200 3200 580 230 2900 1450 2900 2900 430 175 2600 1300 2600 2600 350 115 2320 1160 2320 2320 290 115 2320 1160 2320 2320 290 115 2000 1040 2000 2000 230 115 1750 870 1750 1750 175

Kg/Mtr
.06 .14 .22 .15 .29 .22 .39 .39 .19 .17 .35 .25 .47 .47 .20 .20 .40 .28 .55 .55 .24 .28 .52 .38 .74 .74 .33 .36 .63 .47 .92 .92 .41 .45 .85 .72 1.15 1.15 .53 .54 1.00 .86 1.38 1.38 .68 .66 1.10 .90 1.55 1.55 .78 .82 1.38 1.12 1.94 1.94 .97 1.25 1.90 1.60 2.56 2.56 1.42

lb/ft
.04 .09 .15 .10 .19 .15 .26 .26 .13 .11 .23 .17 .31 .31 .13 .13 .27 .19 .37 .37 .16 .19 .35 .25 .50 .50 .22 .24 .42 .31 .62 .62 .27 .30 .57 .48 .77 .77 .35 .36 .67 .58 .92 .92 .45 .44 .74 .60 1.04 1.04 .52 .55 .92 .75 1.30 1.30 .65 .84 1.27 1.07 1.71 1.71 .95

/8

/8

/2

15

/2

12.7

/8

16

/8

16.0

/4

20

/4

19.0

/8

22

/8

22

25

25.4

11/4

32

11/4

32

13/8

35

13/8

34.9

11/2

40

11/2

38

17/8

48

17/8

47.6

50

50.8

*MWP: the Maximum Working Pressure of a hose assembly is limited to the lowest of the MWP's of either of the two end fittings, as given
for each end fitting design on pages 19-33, or of the hose itself as listed above. MWP of the hose reduces with Temperature as given on page 8 Page 10

Bioflex Hose: Special Usage Conditions


Cleaning & Sterilising Systems - CIP, SIP and Autoclave CIP & SIP PTFE liner tubes are chemically resistant to all CIP, SIP and Autoclave conditions. The primary consideration is whether the cleaning and purging cycle is likely to develop an electrostatic charge on the internal surface of the liner, in which case AS (Anti-Static) grade hose is required. AS grade hose and Electrostatic charge generating systems are fully described in the hose liner section. CIP systems using high electrical resistivity solvents like Toluene will require AS grade hose. Another electrostatic generation problem arises when wet steam is used, or when the cleaning fluids or WFI are purged out of the line using nitrogen, compressed air or another gas, because droplets of liquid or water in the gas then generate a multiphase condition until they are cleared out, which will generate a static charge, and so will require AS grade hose. In static generating applications where AS grade hose is not acceptable due to the black PTFE liner, alternative solutions are available please consult Aflex Hose for advice. Autoclave Autoclave sterilisation does not normally involve any high flow rates through the hose bore, so static generation is not a problem. Aflex hose grades GP and AS, with SS or HB braids are fully resistant to all autoclave conditions throughout the service life of the hose. The rubber covered grades EPDM, (RC) and Silicone Rubber (RC, SI) are able to withstand at least 100 x 30 minute autoclave cycles at relatively high autoclave temperatures (upto 135C, 275F). Consult Aflex Hose for more specific information. PTFE Hose-Use with Alkali Metals, Halogens and Halogen containing Chemicals PTFE hose liners react chemically with Fluorine, Chlorine Trifluoride and molten Alkali Metals. When PTFE lined hose is used to carry Chlorine or Bromine, either as gasses or fluids, they will diffuse into and through the PTFE liner wall thickness. Trace quantities will then combine with atmospheric moisture to corrode any braid/rubber outer coverings. Heavily halogenated chemicals, like Hydrogen Fluoride, Hydrogen Chloride, Phosgene (Carbonyl Chloride) Carbon Tetrachloride and other organic chemicals with a high halogen content can also be absorbed and transmitted through the PTFE liner tube. Other Penetrating Fluids and Gases Sulphur Trioxide, Methyl Methacrylate and Glacial Acetic Acid are some other chemicals which can be absorbed and transmitted through the PTFE liner tube wall. Generally, however, as a hydrophobic (non-wetting) material, PTFE is very resistant to the absorption of chemicals. In some cases, PTFE has superior resistance to diffusion, for example to the diffusion of automotive fuels, in comparison with all other plastics and rubbers. Gas/Fluid Cycling There are some applications where the fluid passing through the hose turns into a gas, then back into a fluid, then into a gas etc, in a cyclic sequence. This is normally associated with changes in temperature and/or pressure. For complex reasons these conditions are extremely damaging to the hose liner, whatever material it is made from. For example, hoses are sometimes used to pass steam, water, steam etc into rubber moulding presses, in order to heat the mould, then rapidly cool it before reheating in the next cycle. Hoses of all types fail rapidly in such an application and PTFE lined hoses are no exception. Please contact Aflex Hose for further information if these conditions apply. Connecting Assemblies for Use in Applications The lengths of hose assemblies and their configuration in use when connected into the application must always be in accordance with the Hose Configuration information at the end of this product literature. When being connected for use in applications, the end fittings on hose assemblies must be connected to correct mating parts in the correct way, using the correct tools, spanners, clamps, nuts and bolts etc. The connections must be sufficiently tightened to ensure that the joint is leak free but not be over tightened as this can damage the sealing surfaces, especially with PTFE lined and flared end fittings. In applications involving the transfer through the hose of expensive or dangerous fluids or gases, the hoses and connections must be pressure tested in situ before being put in to service. This should be done with some harmless media to 1 times the maximum working pressure of the hose assembly, as stated in the product literature. If in doubt please contact Aflex Hose for advice. Special Applications Aflex Hose PTFE lined hose products are not rated as suitable for use in the following, special applications: All Radioactive Applications involving high energy radiation, including Gamma radiation (degrades PTFE) All Medical Implantation Applications. All Aerospace Applications.

Page 11

Bioflex and Quality Assurance, Certification and Approvals, and Hose Testing
BS EN ISO 9001:2008
Aflex products are all manufactured in accordance with BS EN ISO 9001: 2008 Quality Management Systems independently assessed and registered by National Quality Assurance Limited (NQA).

USP CLASS VI and ISO 10993-5, 6, 10 and 11 GUIDELINES


Natural and Antistatic PTFE Hose Liners, Platinum Cured Silicone Rubber Covers (White and Clear) and EPDM Rubber Cover (Blue) have been independently tested in accordance with USP protocols and are found to conform to the requirements of USP Class VI Chapter <88>. Natural and Antistatic PTFE Hose Liners now also meet the more stringent USP Class VI and ISO 109936,10 and 11 guidelines at 121C (250F) with a no reaction classification. Natural and Antistatic PTFE Hose Liners and Platinum Cured Silicone Rubber Covers (White and Clear) have also been tested in accordance with USP protocols and are found to conform to the requirements of USP Class VI <87>, the L929 MEM Elution Test and are considered non-cytotoxic. Natural and Antistatic PTFE Hose Liners have now been further tested and have passed the more stringent USP Class VI and ISO 10993-5 guidelines at 121C (250F).

FDA
The Materials used to manufacture the natural PTFE Tube liner conforms to FDA 21 CFR 177.1550, and the antistatic PTFE liner conforms to FDA 21 CFR 178.3297.

3-A Sanitary Standards


The PTFE used in the liner is manufactured solely from materials which meet the requirements of the 3-A Sanitary Standards.

BPSA LEACHABLES and EXTRACTABLES TESTING


Aflex Hose Natural and Antistatic PTFE Hose Liner Tube has been independently tested in accordance with BPSA recommendations, and found to be satisfactory. Copies of the Test Report are available for specific assessments to be made.

Pharmaceutical Manufacturers Approvals


Most of the major pharmaceutical manufacturing companies in the world have audited and/or approved Aflex Hose as a Hose Supplier.

CE Marking (Europe only)

NATION A

Aflex has been assessed by Zurich Engineering and found to comply with the Pressure Equipment Directive 97/23/EC (European Community) Conformity Assessment Module D1, approved to CE Mark applicable hose products, accompanied by a Hose Usage Data Sheet, and a Declaration of Conformity.

UALI TY A LQ
URANCE URANCE URANCE L L L SS SS SS

Attestations of Conformity to ATEX Directive 94/9/EC (Potentially Explosive Atmospheres)


Available for hose and assemblies for components used in Gas Zones 1 & 2 and Dust Zones 21 & 22, when applicable.

Material Certification to EN10204

Available for all the hose or hose assembly components.

Certificates of Conformity to BS EN ISO/IEC 17050


Are available for all products.

Fuel Hose Approval to SAE J1737


Bioflex hose samples have been tested and approved to SAE J1737 for Automotive Fuel Hose applications.

Hose Testing

Each assembly is pressure tested to 1.5 times maximum working pressure before despatch, and pressure test certificates can be supplied.

Page 12

ED TED ITED MIT MI IIIM

How to Order Bioflex


How to Order
The quantity, hose size, liner, braid, cover, protection system, length and fittings must be selected and specified in full. EITHER by a full, written description. The hose grade can be specified by the code initials e.g. Bioflex AS, SS, RC, DRC-300 defines an antistatic PTFE lined hose with an EPDM rubber cover over a SS braid, with a double rubber cover at both ends. The quantity, length and fittings can then be written in - e.g. 4 off x 1 bore Bioflex, AS, SS, RC, DRC-300 hose x 3.00 metres long. Both ends non-lined ANSI 150# S/S Flanges. OR by Part Numbers, as defined on page 14. Example from above 4 off Part No. 16-BFX/AS-RC-00-3.00m-12-12, with DRC 300 at both ends. Any special requirements relating to the hose construction, or information required on Tags, or Certificates, or special testing of requirements, must be specified in full on the enquiry or purchase order.
Grade BS - British Standard AISI - American Standard or C = Casting Grade AISI 316 L CF8M AISI 304 EN - European Norm

Selecting the End Fittings


Bioflex is available with a range of standard end fittings (described on pages 15-32), normally supplied hygienically PTFE lined and flared.

Stainless Steel End Fitting Materials


Non-Lined Spigots - are all made from Grade 316L SS PTFE Lined Spigots - are all made from Grade 316L or Grade 316C SS Cam and Groove Female Fittings - are made from Grade 316C SS (Body) and 316L SS (Spigot) Swivelling Nuts and Flanges - are all made from Grade 304 SS Ferrules - most ferrules are made from Grade 304 SS, except some are made from Grade 3116L SS - consult Aflex Hose if necessary. The equivalent specification for the different Grades of Stainless Steel are listed below: Specification Equivalents List

Selecting the Hose Grade


There are two types of PTFE liner available, natural (GP) and antistatic (AS) and four types of braid, Grade 304 stainless steel (SS) polypropylene (PB), Hastelloy (HB), PVDF or Kynar (KYB). These are described on page 15 & 16. Rubber covering and other external protection systems are also available, described on pages 17 & 18. A hose grade is specified by using the abbreviations given. For example, Bioflex AS,PB would describe a hose with an anti-static PTFE liner and a polypropylene braid.
316L SS 316C SS 304 SS BS 316 S11 BS 316 C16 BS 304 S15

EN 1.4404 EN 1.4408 EN 1.4301

To special order, end fitting components can be made in nonstandard grades of SS such as 1.4435, or other materials such as Hastelloy or Monel.

Conditions of Sale
Bioflex hose and hose assemblies are only supplied on the basis that the customer has read and accepted the Conditions of Sale as given on page 40.

Selecting the Hose Length (see also pages 37 - 39)


Bioflex hose assemblies are made up to the specific lengths required. The hose length is taken as the length from the sealing face at one end of the hose to the same at the other end. The length tolerance is normally +5%-0%. Closer tolerances are available to special order.
*Bioflex Hose Assembly Length Limitations Nominal Size of Hose in
3

*Used Straight All Types in 3 3 3 3 3 3 4 4 4 4 4 mm 75 75 75 75 75 75 100 100 100 100 100

*Minimum Hose Length Between Fittings *Flexed Thru 90 TO, KYB SS, PB, RC in 3.00 3.00 4.00 4.72 5.71 6.89 8.66 10.04 11.22 17.32 18.70 mm 75 75 100 120 145 175 220 255 285 440 475 in 3.00 3.00 3.00 4.00 4.00 4.33 6.30 7.48 8.66 11.81 12.40 mm 75 75 75 100 100 110 160 190 220 300 315

Maximum Hose Assembly Length

mm 10 15 16 20 22 25 32 35 40 48 50

ft
60 60 60 60 60 60 60 60 55 43 33

mtrs
18 18 18 18 18 18 18 18 17 13 10

/8 /2 /8 /4

1 5 3 7

/8

1 11/4 13/8 11/2 17/8 2

* Listed minimum lengths are for the Bioflex Hose only, and DO NOT INCLUDE THE LENGTHS OF THE FITTINGS AT EACH END. Used straight with fittings in line. Only minimal vibration permitted. These must be found from the end fitting pages and added to calculate the minimum length of the hose assembly. Sizes up to 1 can be supplied in maximum lengths of up to 36 metres (120 ft) to special order. Page 13

Bioflex Hose Assembly Part Number system


If required, Bioflex Hose Assembly can be defined by an individual Part Number, made up of 7 entries as below:
1 Hose Size
3/8 1/2 5/8 3/4 7/8

Size Part No. 06 08 10 12 14 16 22 24 30 32 Type Part No.

&

Assembled End Fitting Description *All Components in Stainless Steel JIC Female Fixed Male Pipe, NPT Thread Fixed Male Pipe, BSPT Thread Fixed Female Pipe, NPT Thread JIC-to-NPT Male Union JIC-to-Female Male Union Straight Sanitary Tri Clamp, 1.984 Diameter 0.870 Exit Diameter (Standard) 1.370 Exit Diameter (Step-Up) Straight Mini Sanitary Tri Clamp, 0.984 Diameter 0.370 Exit Diameter (Standard) 1.620 Exit Diameter (Step-Up) *ANSI 150# Swivelling Flange Non-Lined DIN PN 10/16 Swivelling Flange Non-Lined

End Fitting Part No. 02 03 03/B 06 08 08F 10 10/S 11 11/S 12 12/PN 12L 12L/PN 16 16L 17 17L 23L 24L 26L 27L 33 34

1 13/8 11/2 17/8 2 2 Hose Type Bioflex GP (Natural PTFE Liner) Bioflex AS (Antistatic PTFE Liner) 3

BFX/GP BFX/AS

Braid and Cover Tube Only Stainless Steel Braid Polypropylene Braid Hastelloy Braid Kynar (PVDF) Braid Blue EPDM Rubber Cover (on SS) Transparent Silicone Rubber (on SS) Red Fireproof EPDM Rubber (on SS) RC-300 Rubber Covered End Protection Systems (page 15) see * Note below TO SS PB HB KYB RC SI FP

*ANSI 150# Swivelling Flange, PTFE Lined DIN PN 10/16 Swivelling Flange, PTFE Lined Cam and Groove, Locking Arm Swivelling Female, Non-Lined Cam and Groove Locking Arm Swivelling Female, PTFE Lined Cam and Groove Male, Non-Lined Cam and Groove Male, PTFE Lined DIN 11851 Female, PTFE Lined DIN 11851 Male, PTFE Lined SMS Female, PTFE Lined RJT Female, PTFE Lined BSPP Cone Seat Female BSP Lug Nut Female

*For flange only, Carbon Steel Zinc Plated, add /ZP or Epoxy coated add /EC Notes: ELBOWS - Elbow Fittings for all types are indicated by adding /90 for 90 elbows. TRICLAMPS: For Hot Formed PTFE Lined Triclamps add /HF

External Protection Systems No External Protection System SS Wire Protection Coil Rubber Anti-Scuff Rings Safegard HDPE Spiral Wrap Kink Resistant OO PC SR SG KR Example: a 3/4 bore Bioflex GP RC Hose Assembly with an Antistatic PTFE Liner and , an outer Safegard sleeve. End (1) - a 3/4 ANSI 150# Swivel Flange, PTFE Lined End (2) - a Cam and Groove Swivelling Female, PTFE Lined Length - 4ft 6 inches Hose Assembly Part No. = 12 - BFX/AS - RC - SG - 54in - 12L - 16L 7 1 2 6 5 4 3 ADDITIONAL REQUIREMENTS Any additional requirements which are not included in the Part Number must be written out in full in the Order, including any special labelling or colour coding. * Note - if one of the rubber end protection systems is required, for one or both ends, please define the requirement in writing in addition to the Part Number. Page 14

Length The overall hose length between the sealing faces at each end is given as the Length Part No, either in decimal Metres followed by m or Inches followed by in.

Bioflex Hose Liners


GP - General Purpose Liner AS - Anti-Static PTFE Liner

Purpose Bioflex GP is the General Purpose grade, for use in all applications where fluids or gases are being conveyed which do not generate a risk of static charge development (see AS). Design & Approvals A full list of Approvals is given on Page 12. Bioflex GP is a virgin PTFE liner, manufactured from hose grade PTFE which conforms to the requirements of: FDA 21 CFR 177.1550 Bioflex GP hose liner tube has also been tested, and complies with USP Class VI, at 37C (99F), 70C (158F) and at 121C (250F) - see page 12. Bioflex GP and AS PTFE Liner Tubes have also been tested for Leachables and Extractables in accordance with BPSA recommendations, and were found to be satisfactory. EC - ELECTRICAL CONTINUITY (Also known as Electrically Bonded) All Bioflex hose assemblies are electrically continuous, except Grade TO. Electrical Continuity requires that the hose assembly supplied is electrically continuous, or conductive, between metal end fittings at each end of the hose (whether GP or AS grade). The requirements for this are specified in the German Document BRG 132 and EN ISO 8031:2009 Annex A, when tested in accordance with EN ISO 8031:2009 Clause 5, which requires that the resistance between end fittings shall be <102 ohms per assembly. For hose assemblies which meet this requirement a Grade "M" marking can be applied in accordance with EN ISO 8031:2009 Annex A if requested. The only exception is for assemblies without braid. Grade AS, TO (Antistatic, Tube Only) meets the requirements of , 103 - 108 ohms per assembly, but Grade GP TO (Natural, Tube Only) does , not meet either M or .

Purpose Bioflex AS is an essential requirement in applications where there is the risk of an electrostatic charge build-up on the inside surface of the PTFE tube which may then discharge through the tube wall. Media passing through which create such a risk are fluids which have a Conductance of less than 10-8 S/m (Siemens per Metre), or 104 pS/m such as fuels, solvents, freons, some WFI (ultra-pure Water for Injection) and non-polar organics which are being transferred at a medium to high flow velocity. All twin or multi phase media, and any non-mixing media, such as powder in air, or water droplets in steam, in gases or in oil, also colloidal fluids constitute a particular hazard for static charge generation, and always require grade AS. If in doubt, consult Aflex Hose. Design & Approval Bioflex AS is an anti-static PTFE liner manufactured from FDA 21 CFR 177.1550 approved PTFE, and less than 2.5% of high purity Carbon Black material to FDA requirement 21 CFR 178.3297. The carbon is encapsulated by the PTFE, and in normal, non-abrasive applications will not come loose to contaminate any fluid passing through. Leachables and Extractables testing confirmed that no carbon was found. A typical example involves cleaning systems which create a twin phase mixture passing through the hose a high velocity, such as WFI water purged out with air or nitrogen. Bioflex AS also conforms to USP Class VI, at 37C (99F), 70C (158F) and at 121C (250F) - see page 12. Antistatic Hose Assemblies When "AS" (Antistatic) grade hose is specified, then the hose or hose assembly supplied will be tested in accordance with EN ISO 8031:2009 Clause 7 using electrodes specified in EN ISO 8031:2009 Clause 4.2.2.2 d) (and Clause 4.2.2.2 e if the hose has an antistatic cover) and meet the Antistatic requirements of EN ISO 8031:2009 Annex A. This requires, for an antistatic liner or antistatic cover, that the resistance between an appropriately placed foam electrode and a metallic end fitting will be between 103 to 108 ohms per assembly. For hose assemblies which meet these requirements an appropriate Grade "" marking can be applied in accordance with EN ISO 8031:2009 Annex A if requested. NOTE: When in service, at least one end fitting must be connected to earth, to permit dissipation of the static charge from the end fitting. Page 15

Bioflex Hose Braids


SS - Stainless Steel Braid TO - Tube Only (no braid)

Purpose Stainless Steel braided hose is the general purpose product, and can be used in applications involving high temperatures and working pressures. High tensile AISI 304L stainless steel wire is used, to give maximum pressure resistance and external protection to the hose.

Purpose TO grade hose (available in both GP and AS) is a lightweight hose, used in applications where working pressures are low and where there is no need for the physical protection offered by an external braid. TO grade tube is fully vacuum proof up to 100C. TO grade hose assemblies are not Electrically Continuous (EC).

PB - Polypropylene Braid

HB - Hastelloy Braid (C276 grade)

Purpose Purpose Polypropylene braided hose is often preferred to SS in applications involving frequent handling and movement of the hose, and where temperatures are within the range -30C and +100C (-22F to +212F). PB braid is lighter in weight, and any broken strands will not cut the operators hands. In addition, PB braid is not prone to chloride stress corrosion, and has generally good chemical resistance. To ensure *Electrical Continuity between end fittings 2 strands of Monel wire earthing strips are criss-crossed on to the liner, underneath the Polypropylene Braid. These are folded back underneath the ferrule at both end fittings, to make an electrical contact. NOTE: Prolonged exposure to sunlight eventually results in UV degradation of PB braid. Hastelloy Wire Braid is used instead of SS where severe chemical corrosion conditions exist around the outside of the hose. One way in which this can happen is when Chlorine or Fluorine are being transferred. Diffusion of trace quantities of such gases through the PTFE liner can lead to atmospherically wetted fluorine or chlorine attacking the braid material, in which case the Hastelloy Braid would be resistant. Specifications Same as for SS on Pages 9 and 10, except the Burst Pressures and the Maximum Working Pressures are both reduced to 50% of the SS pressures listed.

KYB - Kynar Braid (Polyvinylidene Fluoride Monofilament)

Purpose Kynar Braid is used for the same reasons as HB above, but only in applications where the reduced pressure and temperature ratings of KYB as listed are acceptable. Electrical Continuity is ensured using the same design as for Bioflex PB. Page 16

Bioflex Rubber Covers


RC - Rubber Covered FP - Fireproof Rubber Covered

Purpose For the most rugged applications where the hose may be subjected to rough treatment and severe external abrasion. Also for hygienic applications, where the external smoothness and cleanability of the hose is of prime importance. Design An SS braided hose assembly has a smooth finish, blue EPDM external rubber cover extruded over and vulcanised directly onto the braid. EPDM has excellent chemical resistance, and the hose has a temperature range from -40C, -40F up to +140C, +284F (internal fluid) or +120C, +248F (external temperature). Black anti-static EPDM, and alternative colours of rubber, and strips with alternative text titles are available to special order. Specifications The Blue EPDM rubber cover has been tested and conforms to the requirements of USP Class VI.

Purpose As for RC hose, but where the hose is also required to resist failure in the event of fire, in accordance with Specification BS5173 Section 103.13 part 6.3 (Fireproof). This specification calls for an 1100C (2012F) flame to be applied to the hose at minimum bend radius, maximum operating pressure (water), and one end fitting under vibration. The hose must withstand at least 15 minutes without leakage. Design As for RC hose, but the red EPDM rubber is specially compounded to be fire resistant. Black, anti-static EPDM Fireproof rubber is also available as an option to special order.

RC-300 - Rubber Covered 300mm End Protection

SI - Silicone Rubber Cover

Purpose In applications where excessive flexing of the hose at the end fitting occurs, it is sometimes necessary to stiffen the hose in this area, to prevent kinking. Design Purpose As for RC hose, but where the hose may be required to withstand temperatures from -73C, -100F up to +204C, +400F. SI grade hose is semi-transparent, allowing visual monitoring of the braid, with a very smooth external surface finish. Design An SS braided hose assembly has a platinum cured silicone rubber cover extruded directly onto the braid, with a very smooth external surface finish. Specifications The Silicone rubber cover has been tested and conforms to the requirements of USP Class VI. The rubber used is normally Blue EPDM, but if the hose is FP or SI , covered, then the same type and colour of rubber would be used (DFP-300 or DSI-300). Limitations Cannot be applied to PB or KYB braided hose. If required for a PB hose, consult Aflex Hose for an alternative EPR system. (EPR includes a 300mm (12 inch) length of loose rubber hose jubilee clipped to the ferrule). A layer of rubber is applied and vulcanised directly to the ferrule, and 300mm (12 inch) along the hose from the fitting. This can be done either on an SS braided hose (RC-300) or on a rubber covered hose as a 300mm (12 inch) long double layer of rubber at the end (DRC300).

Page 17

Bioflex External Protection Systems


KR - Kink Resistant SR - Scuff Rings

Purpose For applications where there is a risk that the hose might be severely flexed anywhere along its length, and possibly kinked as a result. NOTE: The rubber cover hose has a cloth finish, not the very smooth finish normally available. Design KR is only available on hoses which also have a SS wire braid and a rubber cover (RC, FP or SI). An SS reinforcement wire is helically wound on to the SS wire braid, then the rubber cover is applied on top of the helical wire. Limitations Only available for sizes 1/2 and above. Specifications as for the relevant RC or SI hose grade on pages 10 & 11.

Purpose For medium duty applications where the hose requires some protection against abrasion when dragged over the ground, but where a full rubber cover would be too heavy and cumbersome. Also for PB and KYB braided hose, which cannot be Rubber Covered. Design Specially moulded abrasion resistant rubber scuff rings are placed every half metre along the hose. Limitations Available for hose sizes 1 (25mm) to 2 (50mm) only. The operating temperature should not exceed 140C (284F) (internal).

SG - Safegard Protection Sleeve

PC - Protection Coil

Purpose To protect the hose against external abrasion and mechanical damage. For use in applications where maximum external protection is required with minimum extra hose weight. Particularly useful with PB or KYB hose, where a rubber cover is not an option. Design A lightweight black, HDPE (High Density Poly Ethylene) strip spirally wound around the outside of the hose over its whole length, secured to each end fitting by crimping under a SS ferrule. Limitations Safegard is applicable to all hose types and all hose sizes from
1/2

Purpose For applications where the hose requires protection against abrasion when dragged over the ground, but where any rubber reinforcement is not permissible due to temperature, chemicals etc. Design A stainless steel wire helix is wound onto the braid and welded to the ferrules at each end. Limitations Available for all sizes and Grades of Bioflex Hose. Specifications As for the relevant Hose Grade.

up to 4.

Safegard is limited to use within a temperature range from -40C (-40F) up to +100F (212F). Internal fluid temperatures up to 120C (250F) are acceptable, when external temperatures are ambient. Other hose usage limitation specifications are not altered by the addition of Safegard. Page 18

Bioflex Non Lined Swivel Flange Fittings

Flange Specification - ANSI B16.5 (also ASME B16.5) Class 150# and 300# - *DIN PN10, PN16 and PN40 - JIS 10K - Other Pressure Ratings and Flange Specifications are also available. *DIN PN10, PN16 and PN40 Flanges all have the same dimensions, and so are fully interchangeable. Maximum Pressure Ratings for Flange Fittings - ANSI 150# = 16 Bar (230 psi), ANSI 300# = 32 Bar (460 psi). - DN PN10 = 10 Bar (145 psi), DN PN16 = 16 Bar (230 psi) - PN40 = 40 Bar (580 psi)

End Fitting Materials - Flanges in Grade 304 SS - Flange Retainers in Grade 316L SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316 SS Alternative Options for Flange Component only: - Zinc Plated Carbon Steel - Blue Epoxy Coated Carbon Steel

Retainer Spigot

Ferrule Flange *Fitting Length A (Bioflex RC) in 2.79 3.15 3.27 4.10 4.17 mm 71.0 80.0 83.0 104.0 106.0 Flared Diameter D ASA150 PN10/16 in 1.38 1.69 2.00 2.88 3.63 mm 35.0 42.9 50.8 73.0 92.0 in 1.77 2.28 2.68 3.47 4.02 mm 45.0 58.0 68.0 88.0 102.0 in 0.38 0.63 0.79 1.25 1.75 Fitting Inside Diameter I mm 9.53 15.88 20.24 31.75 44.45

Nominal Hose Size in


1/2 3/4

mm 13 20 25 40 50

1 11/2 2

*Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades.

Page 19

Bioflex Integral PTFE Lined Flange Fittings & StepUp Design


Flange Specification - ANSI B16.5 (also ASME B16.5) Class 150# and 300# - *DIN PN10, PN16 and PN40 - JIS 10K - Other Pressure Ratings and Flange Specifications are also available. *DIN PN10, PN16 and PN40 Falnges all have the same dimensions, and so are fully interchangeable. Maximum Pressure Ratings for Flange Fittings - ANSI 150# = 16 Bar (230 psi), ANSI 300# = 32 Bar (460 psi) - DN PN10 = 10 Bar (145 psi), DN PN16 = 16 Bar (230 psi) - PN40 = 40 Bar (580 psi) End Fitting Materials - Flanges in Grade 304 SS - Flange Retainers in Grade 316L SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS Alternative options for Flange component only: - Zinc Plated Carbon Steel - Blue Epoxy Coated Carbon Steel. 90 Elbow Flange Fittings 90 Elbow Integral PTFE lined Flange Fittings are available for sizes 1, 11/2 and 2 - see page 33.

integral PTFE Lined Swivel Flange Fittings

(See full description on page 5)


Flared Diameter D ANSI 150# in 1.25 1.690 2.00 2.875 3.625 mm 32 43 50 73 92 DIN PN10/16 in 1.25 1.69 2.50 3.50 4.00 mm 32 43 63 88 102 Fitting Inside Dia. and Hose Bore I in
1/2 3/4

Nominal Hose Size in


1/2 3/4

*Fitting Length A (Bioflex RC) in 1.850 1.890 2.400 2.360 2.720 mm 47.0 48.0 61.0 60.0 69.0

Recommended Bolt Tightening Torques ft.lbs 8 8 10 15 25 mtr. kgs 1.10 1.10 1.40 2.10 3.50

mm 13 20 25 40 50

mm 12.7 19.0 25.4 38.0 50.8

1 11/2 2

1 11/2 2

*Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades.

*Step-Up PTFE Lined Flange Fitting Design for Bioflex Hose


Example: a 2 hose to 3 ANSI 150# PTFE Lined Flange Joint Because Bioflex Hose has better flow rates than some larger bore sizes of Convoluted PTFE hose, it represents a superior alternative when fitted with the larger size flanges in some applications. It is, however, necessary to also Step-Up the PTFE-lined bore, to ensure a diameter match with the mating connector. This is best achieved using a solid PTFE Adaptor Plate, as shown in the drawing. 3 PTFE Lined Pipe 2 Bore Hose Solid PTFE Adaptor Plate A = Pipe Inlet Dia. B = Hose Inlet Dia.

3 ANSI 150# Flanges Page 20

Bioflex Female Cam & Groove Fittings PTFE Lined and Non-Lined
End Fitting Specification - Generally in accordance with A-A-59326 (replaces MIL-C-27487) and EN14420-7:2004 interchangeable. Te m p e r a t u r e a n d P r e s s u r e R a t i n g s - All sizes up to 16 Bar (230 psi) - Up to 100C (212F) Buna N Gasket or 200C (400F) FEP Gasket. 9 0 E l b o w C a m & G r o o v e F i t t i n g s ( L I N E D O N LY ) 90 Elbow Integral PTFE lined Cam & Groove Fittings are available for sizes 1, 11/2 and 2 - see page 33. (replaces DIN 2828), and all are fully End Fitting Materials - Spigot in Grade 316L SS - Body in Grade 316C SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS - Standard Gasket is Buna N (Nitrile) Rubber. - FEP encapsulated Silicone Rubber Gaskets also available.

Swivelling, Locking Arm Female Cam and Groove Fittings - Non Lined

Nominal Hose Size in


3/4

*Fitting Length A (Bioflex RC) in 3.22 3.39 3.97 4.09 mm 82.0 86.5 101.0 104.0

Cam Sleeve Inside Diameter D in 1.260 1.456 2.126 2.520 mm 32 37 54 64 in

Fitting Inside Diameter I mm 15.88 20.24 31.75 44.45 0.625 0.797 1.25 1.75

mm 20 25 40 50

1 11/2 2

Fixed or Swivelling, Locking Arm Female Cam and Groove Fitting - Integral PTFE Lined

Nominal Hose Size in


3/4

*Fitting Length A (Bioflex RC) in 2.155 2.716 2.612 2.966 mm 54.75 69.00 66.35 75.35

Cam Sleeve Inside Diameter D in 1.260 1.456 2.126 2.520 mm 32.0 37.0 54.0 64.0 in 0.75 1.00 1.50 2.00

Fitting Inside Diameter I mm 19.0 25.0 38.0 50.0

mm 20 25 40 50

1 11/2 2

*Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades. Page 21

Bioflex Male Cam & Groove Fittings, PTFE Lined & Non-Lined and Lined Flange Adaptors
PTFE Lined or Non-Lined Male Cam and Groove Fittings
End Fitting Specification - Generally in accordance with A-A-59326 (replaces MIL-C-27487) and EN14420-7:2004 interchangeable. Te m p e r a t u r e a n d P r e s s u r e R a t i n g s - Temperature determined by the type of gasket in the Female connecting component. - Pressures up to 16 Bar (230 psi) (replaces DIN 2828), and all are fully End Fitting Materials - Fittings in Grade 316L SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS - Adaptor Flange Only in Grade 304 SS

Integral PTFE Lined Cam & Groove Male Fitting


AL

Non-Lined Cam & Groove Male Fitting

PTFE Lined Male Fitting

Nominal Hose Size in


3/4

Outside Diameter D in
1.260 1.456 2.106 2.480

Non-Lined Fitting Length A in


3.48 3.94 4.86 5.47

Non-Lined Inside Diameter I in


0.625 0.80 1.25 1.75

PTFE Lined Fitting Length AL in


2.82 3.74 3.98 4.61

PTFE Lined Inside Diameter B in


0.71 0.81 1.35 1.72

mm
20 25 40 50

mm
32.0 37.0 53.5 63.0

mm
88.5 100 123.5 139

mm
15.88 20.24 31.75 44.45

mm
71.58 95 101 117

mm
18.13 20.61 34.40 43.75

1 11/2 2

*Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades.

PTFE LINED MALE CAM and GROOVE X FLANGE ADAPTORS

D I

Cam Action Flange Size & Adaptor Size Specification in mm 25 25 40 40 50 50 1 ANSI 1507 DN25/PN16 11/2 ANSI 1507 DN40/PN16 2 ANSI 1507 DN50/PN16 in

D
mm 50 64 73 88 92 102 in 41/8 4 /8 43/8 43/8 4 /8 43/8
3 1

A mm 105 105 118 118 118 118 in 0.84 0.84 1.35 1.35 1.69 1.69

I mm 21 21 34 34 43 43

N o t e : Other Flange Specifications and Pressure Ratings are also available. Non-Lined adaptors and Female Cam and Groove X Flange Adaptors are also available, to special order.

1 1 11/2 11/2 2 2 Page 22

2.00 2.58 2.87 3.47 3.63 4.00

Bioflex Mini-Sanitary and Sanitary Triclover Fittings, PTFE Lined


End Fitting Specification - BS4825 Pt 3 (UK) - ASME BPE-a-2007 (USA) - DIN32676 (Europe, DN Sizes) - ISO 1127 (Europe) (Non Standard, Specials Only) Te m p e r a t u r e a n d P r e s s u r e R a t i n g s - Pressures up to 16 Bar (230 psi) - Temperatures up to 120C (250F) - Higher Pressures & Temperatures possible with Special Clamps and Rubber Seals. End Fitting Materials - Fittings in Grade 316L SS (= BS 316 S11 = EN 1.4404) - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS

Nominal Hose Size in


3/8 1/2 5/8 3/4 3/4 7/8

Nominal Pipe Size

Flange Diameter D in mm 25.0 25.0 34.0 34.0 50.5 50.5 50.5 50.5 50.5 64.0 64.0 64.0

Outlet Diameter I in
3/8 3/8 5/8 3/4 3/4 7/8

*Fitting Length A (Bioflex RC) in 2.20 2.36 2.48 2.56 2.56 2.60 2.84 2.84 3.15 3.15 3.31 3.58 mm 56 60 63 65 65 66 72 72 80 80 84 91

mm 10 13 16 20 20 22 25 35 40 40 48 50
1/2 1/2

mm 9.5 9.5 16.0 19.0 19.0 22.2 26.0 34.9 34.9 38.0 47.6 47.6

0.984 0.984 1.340 1.340 1.984 1.984 1.984 1.984 1.984 2.521 2.521 2.521

DN15 DN20
3/4

1 DN25 11/2 11/2 2 2 2

1 13/8 11/2 11/2 17/8 2

1 13/8 13/8 11/2 17/8 17/8

Note: The 3/8, 5/8, 7/8, 13/8 and 17/8 hose sizes can only be supplied as assemblies with lined Triclover (or I-Lined fittings) at BOTH ends, because other types of fittings (Flanges, Camlocks etc.) are not available for these sizes of hose. *Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades.

Page 23

Bioflex Sanitary Triclover Fittings, PTFE Lined and Beaded


End Fitting Specification - BS4825 Pt 3 (UK) - ASME BPE-a-2007 (USA) - DIN32676 (Europe, DN Sizes) - ISO 1127 (Europe) (Non Standard, Specials Only) Te m p e r a t u r e a n d P r e s s u r e R a t i n g s - Pressures up to 16 Bar (230 psi) - Temperatures up to 180C (356F) - Higher Pressures possible with Special Clamps. End Fitting Materials - Fittings in Grade 316L SS (= BS 316 S11 = EN 1.4404) - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS

Description In this new design, the PTFE hose liner tube is extended through the Triclover end fitting and is flared over the sealing face. It is then hot-formed to conform to the shape of the rubber seal and therefore replaces the rubber seal. This includes the bead shape which is used for concentric location of the seal to the mating components when a joint is made as shown in the drawing. Advantages of the Bioflex PTFE Beaded End Fitting - After connection, the PTFE does not bulge into the bore in the same way that a rubber seal would. This rubber bulge interferes with the flow path and can cause material entrapment but these problems are eliminated by using the new design. - The need to ensure the compatibility of the rubber seal with the media passing through is no longer a problem, due to the all PTFE sealing system. - The joint includes only one sealing face not 2 as with the rubber seal. - The internal section of the moulded PTFE seal, which is squared off to provide a closed sealing edge in the joint, ensure no crevices in which material entrapment might occur. - If hoses are required to be joined together then the Bioflex PTFE Beaded Triclover End Fitting can be connected to a standard Bioflex Triclover Fitting to provide an all PTFE joint between the hoses.

Nominal Hose Size in


3/4 7/8

Nominal Pipe Size

Flange Diameter D in mm 34.0 50.5 50.5 50.5 64.0

Outlet Diameter I in
3/4 7/8

*Fitting Length A (Bioflex RC) in 2.56 2.60 2.84 2.84 3.31 mm 65 66 72 72 84

mm 20 22 25 35 48 DN20 1 DN25 13/4 2

mm 19.0 22.2 26.0 34.9 47.6

1.340 1.984 1.984 1.984 2.521

1 13/8 17/8

1 13/8 17/8

*Fitting Lengths listed are for Bioflex RC, SI and FP hose grades. Shorter lengths apply for other hose grades.

Page 24

Bioflex Mini-Sanitary and Sanitary Triclover Fittings - Not PTFE Lined

End Fitting Specification - BS4825 Pt 3 (UK) - ASME BPE-a-2007 (USA) - DIN32676 (Europe, DN Sizes) - ISO 1127 (Europe) (Non Standard, Specials Only) Te m p e r a t u r e a n d P r e s s u r e R a t i n g s For Standard Clamp and Standard (EPDM) Gasket - Pressures up to 16 Bar (230 psi) - Temperatures up to 120C (250F) - Higher Pressures and Temperatures with Special Clamps and Gaskets.

End Fitting Materials - Fittings in AISI 316L = EN 1.4404 = BS 316 S11. Internal Bores all Electropolished to <15in Ra (<0.375 mtr). - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS Outlet Diameters (Inch pipe sizes only) The outlet diameters as listed are in accordance with BS4825. The ASME specification, however, requires these diameters to be 0.005 (0.125mm) less in each case. An Outlet Diameter tolerance of +0.000 -0.005 has therefore been applied, so that the same fitting satisfies requirements of both specifications. MINI-SANITARY TRICLAMP (TRICLOVER) FITTINGS Nominal Hose Size
1/2 1/2 3/4

Nominal Pipe Size


1/2

*Fitting Length A in mm 72 72 79

Flange Dia. D in 0.984 0.984 0.984 mm 25.0 25.0 25.0

*Outlet Dia. I in mm
3/8 5/8 5/8

& DN10
3/4 3/4

2.8 2.8 3.1

9.5 16.0 16.0

SANITARY TRICLAMPS (TRICLOVER) FITTINGS Nominal Hose Size


1/2 3/4 3/4 3/4

Nominal Pipe Size 1 DN15 ISO (DN) 15 ISO (DN) 20 1 DN25 ISO (DN) 25 11/2 11/2 DN40 2 DN50 21/2 DN65 3 DN80

*Fitting Length A in 2.7 3.0 3.0 3.0 3.2 3.2 3.2 3.2 3.9 3.9 4.1 4.1 4.3 4.3 4.3 4.3 mm 69 77 77 77 82 82 82 82 98 98 103 103 110 110 110 110

Flange Dia. D in 1.984 1.156 1.984 1.984 1.984 1.984 1.984 1.984 1.984 1.984 2.516 2.516 3.047 3.047 3.579 mm 50.5 34.0 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 64.0 64.0 77.5 77.5 91.0

*Outlet Dia. I in mm
7/8 5/8

22.2 16.0

0.713 18.10 0.934


7/8

23.7 22.2 26.0 29.7 34.9 34.9 38.0 47.6 50.0 60.3 66.0 73.0 81.0

1 1 1 1 11/2

1 1.170

13/8
13/8 11/2 17/8 1.975 23/8 2.600 27/8

11/2
2 2 2 2 2 2

4.176 106.0 3.191

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex Page 25

Bioflex 90 Elbow Triclover Fittings (90 Elbow Mini-Sanitary & Sanitary Triclamp Fittings)

End Fitting Specification - BS4825 Pt 3 - ASME-BPE-a-2007 Others to Special Order Te m p e r a t u r e a n d P r e s s u r e R a t i n g s For Standard Clamp and Standard (EPDM) Gasket - Pressures up to 16 Bar (230 psi) - Temperatures up to 120C (250F) - Higher Pressures and Temperatures with Special Clamps and Gaskets. End Fitting Materials - Fittings in Grade AISI 316L = EN 1.4404 = BS 316 S11 - Internal Bore average 15in Ra, Electropolished if required - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS Outlet Diameters The outlet diameters as listed are in accordance with BS4825. The ASME specification, however, requires these diameters to be 0.005 (0.125mm) less in each case. An Outlet Diameter tolerance of +0.000 -0.005 has therefore been applied, so that the same fitting satisfies requirements of both specifications. Ferrule Fitting

Nominal Hose Size in


1/2 3/4

*Centre Line To Fitting End A (Bioflex RC) in 5.78 6.41 6.53 7.99 9.33 mm 147 163 166 203 237

Centre Line to Face B in 1.60 1.60 2.00 2.75 3.50 mm 41.0 41.0 51.0 70.0 88.9

Flange Diameter D in 0.984 0.984 1.984 1.984 2.16 mm 25.0 25.0 50.5 50.5 64.0

*Outlet Diameter I in
3/8 5/8 7/8

mm 13 20 25 40 50

mm 9.5 16.0 22.2 34.9 47.6

1 11/2 2

13/8 17/8

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex

Page 26

Bioflex DIN11851 Male & Female Fittings, PTFE Lined, and Female Fittings, Non-Lined
Description DIN11851 male and female fittings, integral PTFE lined and flared. The PTFE sealing face is hot moulded into the correct shape, designed to achieve the optimum pressure seal. 90 elbow PTFE lined fittings are available for some sizes and grades - see page 33. Specification - Generally to German DIN 11851 specifications. NB: The PTFE lined male fitting is designed to be used without a rubber seal. Please note that when connecting to a PTFE Lined DIN 11851 Male, extra spanner tightening of the nut is sometimes required in order to provide a leak free connection. Fitting Materials - Spigots in Grade 316L SS (Non-Lined Spigot in 1.4571) - Nuts in Grade 304 SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS Te m p e r a t u r e & P r e s s u r e R a t i n g s - Sizes up to 11/4 MWP = 40 Bar (580 psi) up to 130C (266F) - Sizes 11/2 & 2 MWP = 25 Bar (360 psi) up to 130C (266F) Except where the applicable hose pressure/temperature ratings are lower (page 8).

DIN11851 MALE & FEMALE FITTINGS, PTFE LINED

PTFE Lined DIN11851 Male Fitting

PTFE Lined DIN11851 Female Fitting

Nominal Hose Size = I Dia. in


1/2 3/4

*Male Fitting Length A (M) (Bioflex RC) mm 15 20 25 32 40 50 in 2.28 2.44 3.00 2.75 2.84 3.47 mm 58 62 76 70 72 88

*Female Fitting Length A (F) (Bioflex RC) in 2.00 2.17 2.75 2.50 3.00 3.55 mm 51 55 70 64 76 90

1 11/4 11/2 2

DIN11851 FEMALE FITTING, NON-LINED


Nominal Hose Size in
1/2 3/4

I Diameters in 0.375 0.625 0.797 1.030 1.250 1.750 mm 9.5 15.9 20.2 26.2 31.8 44.5

*Fitting Length A in 2.58 3.00 3.20 3.82 3.82 3.94 mm 65 76 81 97 97 100

mm 15 20 25 32 40 50

1 11/4 11/2 2

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex Page 27

Bioflex SMS Female Fittings - PTFE Lined, RJT Female Fittings - Non Lined
End Fitting Specification - SMS generally to Swedish SMS1148 specification. - RJT generally to British BS4825 Pt 5 specification. Te m p e r a t u r e a n d P r e s s u r e R a t i n g s - Pressures up to 10 Bar (150 psi) - Temperatures up to 150C (302F) End Fitting Materials - Spigots in Grade 316L SS - Nuts in Grade 304 SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS 90 Elbows PTFE Lined 90 elbow fittings are available for some sizes and grades see page 33.

SMS FEMALE FITTING, PTFE LINED

Nominal Hose Size in 1 11/4 11/2 2 mm 25 32 40 50

*Fitting Length A (Bioflex RC) in 3.39 3.39 3.70 4.10 mm 86 86 94 104

Fitting Inside Diameter I in 1 11/4 11/2 2 mm 25.4 32.0 38.0 50.8

RJT FEMALE FITTING, NON LINED

Nominal Hose Size in 1 11/2 2 mm 25 40 50

*Fitting Length A (Bioflex RC) in 2.95 3.58 3.66 mm 75 91 93

Fitting Inside Diameter I in 0.80 1.25 1.75 mm 20.24 31.75 44.45

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex Page 28

Bioflex NPT and BSPT Fixed Male and NPT Fixed Female Fittings
End Fitting Specification - NPT Taper Threads to American National Standard Pipe Taper Thread design to ANSI B2.1 End Fitting Materials - Fittings in Grade 316L SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS

- BSPT Threads to British Standard Pipe Taper Thread design to BS21 Alternatives - Fittings in Zinc Plated Carbon Steel Alternatives - Parallel Threads, Metric Threads and Others.

FIXED MALE NPT or BSPT

Nominal Hose Size in


1/2 3/4

NPT or BSPT Thread Size in


1/2 3/4

*Fitting Length A (Bioflex RC) in 3.30 3.74 4.13 4.90 5.19 5.78 mm 84 95 105 124 132 142 in 0.38 0.63 0.80 1.00 1.25 1.75

Fitting Inside Diameter I mm 9.53 15.88 20.24 25.40 31.75 44.45

mm 13 20 25 32 40 50

1 11/4 11/2 2

1 11/4 11/2 2

FIXED FEMALE NPT

Nominal Hose Size in


1/2 3/4

NPT ----Thread Size in


1/2 3/4

*Fitting Length A (Bioflex RC) in 3.42 3.66 4.13 4.80 4.96 mm 87 93 105 122 126 in 0.38 0.63 0.80 1.25 1.75

Fitting Inside Diameter I mm 9.53 15.88 20.24 31.75 44.45

mm 13 20 25 40 50

1 11/2 2

1 11/2 2

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex

Bioflex BSP 60 Cone Seat Female Unions and BSP Flat Seat Lug Nut Female
End Fitting Specification - BSPP Threads to British Standard Pipe Parallel Thread design to BS21, 60 Cone Seat design, or Flat Seat. Alternatives - Cone Seat Female Union Fittings can be supplied with a BSPP/BSPT Taper Male Adaptor if required. End Fitting Materials - Spigots in Grade 316L SS - Nuts in Grade 316L SS - Ferrules, most in Grae 304 SS, some sizes in Grade 316L SS Alternatives - Cone Seat Female Unions can be supplied in Zinc Plated Carbon Steel if required. - Lug Nuts can be supplied in Gun Metal (Bronze) if required.

B S P 6 0 C O N E S E AT F E M A L E U N I O N F I T T I N G

Nominal Hose Size in


1/2 3/4

NPT or BSPT Thread Size in


1/2 3/4

*Fitting Length A (Bioflex RC) in 3.27 3.62 3.86 4.65 4.80 mm 83 92 98 118 122 in 0.37 0.63 0.80 1.25 1.75

Fitting Inside Diameter I mm 9.35 15.88 20.24 31.75 44.45

mm 13 20 25 40 50

1 11/2 2

1 11/2 2

B S P F L AT FA C E LU G N U T F E M A L E F I T T I N G

Nominal Hose Size in 1 11/2 2 mm 25 40 50

BSPP Thread Size

*Fitting Length A (Bioflex RC) in 3.70 3.66 3.70 mm 94 93 94

Fitting Bore Diameter I in 0.80 1.25 1.75 mm 20.24 31.75 44.45

in
1 11/2 2

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex Page 30

Bioflex 37 JIC Female Fittings and Male & Female NPT Unions
End Fitting Specification - SAE J514 37 Flare JIC Female Fitting - 37 JIC Male-to-NPT Male/Female Adaptors - NPT Threads to ANSI B2.1 Te m p e r a t u r e a n d P r e s s u r e R a t i n g s Same Maximum Working Pressure and Temperature as for the relevant size of Bioflex Hose, on page 6. End Fitting Materials - Spigots in Grade 316L SS - Nuts in 316L SS - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS Note - Not usable with SAE 45 Flare fittings which have the same thread. Alternatives - Can be supplied in other materials, such as zinc plated carbon steel, Hastelloy, Monel etc.

Swivelling Nut
*Fitting Length A (Bioflex RC) in 2.76 3.07 3.23 4.00 4.33 mm 70 78 82 102 110 in 0.88 1.25 1.50 2.25 2.88 Hex Size H mm 22.2 31.7 38.1 57.1 73.0 in 0.38 0.63 0.80 1.25 1.75 Fitting Inner Diameter I mm 9.5 15.9 20.2 31.7 44.4

Nominal Hose Size in


1/2 3/4

37 JIC Thread Size in


3/4

mm 13 20 25 40 50

-16

11/16 -12 15/16 -12 17/8 -12 21/2 -12

1 11/2 2

JIC TO NPT MALE UNION (Including a JIC MALE-TO-NPT MALE ADAPTOR)

JIC TO NPT FEMALE UNION (Including a JIC MALE-TO-NPT FEMALE ADAPTOR)

Swivelling Nut

Male Adaptor

Swivelling Nut

Female Adaptor Fitting Inner Diameter I in 0.38 0.63 0.80 mm 9.5 15.9 20.2

Nominal Hose Size in


1/2 3/4

*Male Union Length A1 (Bioflex RC) in 4.13 4.92 5.43 mm 105 125 138

*Female Union Length A2 (Bioflex RC) in 4.25 4.80 5.12 mm 108 122 130

mm 13 20 25

*Fitting lengths listed are for Bioflex RC, SI and FP Grades. Shorter lengths apply for other grades of Bioflex Page 31

Bioflex PTFE Dip Pipes, Straight or 90 Elbow


FIXED DIP PIPES
Description Fixed Dip Pipes are fairly rigid, thick wall PTFE tubes, either straight or 90 elbowed, which are directly crimped to the end of Bioflex hoses. They are designed for insertion into drums, tanks and reaction vessels in order to suction drain (or inject) process fluids transferred through the hose. Materials - Standard dip pipes are in anti-static (AS) PTFE - Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS How to order Specify the size and material of the dip pipe, whether it is straight or 90 elbowed. Give the length of the straight leg of the dip pipe and the length of the rest of the hose assembly separately. M a x i m u m Wor k i n g P r e s s u r e s Dip Pipes are normally only tested to 4 Bar Pressure, and are not suitable for use at pressures higher than 3 Bar. They are usable at negative pressure up to full vacuum. If higher pressure ratings are required, consult Aflex Hose. Lengths Dip Pipes are supplied as standard in 1 metre straight lengths, but can be supplied in any length to individual requirements. 11/2 2 40 50 1.54 2.17 39 55 1.00 1.58 27 40 Nominal Hose Bore Size in
3/4

F I X E D D I P P I P E ( 9 0 E L B O W )

Approximate Dip Pipe Dimensions Outside Diameter D in 0.87 1.14 mm 22 29 Inside Diameter I in 0.51 0.83 mm 13 21

mm 20 25

FIXED DIP PIPE (STRAIGHT)


Length of Dip Pipe

I D

DETACHABLE DIP PIPES


Description As Fixed Dip Pipes above, but connected to the hose through an end fitting, not by crimping direct to the hose. Design A straight, or 90 elbowed anti-static PTFE Dip Pipe, fitted with a Flange or Cam & Groove Male PTFE Lined & Flared end fitting. The most usual end fitting is a Cam Male (as shown), so the dip pipe can then be connected to a hose with a Cam Female end fitting. Specifications As above for Fixed Dip Pipes. Page 32 Overall length of dip pipe

D E TA C H A B L E D I P P I P E

Bioflex 90 Elbow Fittings, PTFE Lined and Non-Lined


PTFE LINED 90 ELBOW FITTINGS
S co p e - All of the PTFE lined end fittings described on previous pages can be fitted as 90 elbow PTFE lined fittings to the design shown, to the sizes listed. - All grades of hose can be used, except PB and KYB.

Fitting Length 90 elbowed S/S tube enclosing S/S braided hose

Off-Set 1 Hose = 85mm 11/2 & 2 Hose = 200mm

Elbow welded to ferrule

Length for straight fitting (See Fitting Page)

PTFE Lined Triclover Fitting shown.

Hose Bore Sizes

Off-Set mm

Fitting Length mm 143 237 314

/8 or 1
1

85 200 200

1 /8 or 1 /2
3

1 /8 or 2

NON-LINED 90 ELBOW END FITTINGS


A 90 elbow attached to the hose can be supplied non-PTFE lined, as shown, for any size or grade of hose or type of fittings, to special order.

Length of Fitting

Elbow welded to spigot Swivelling Flange

Elbow welded to stub end

Page 33

Bioflex Steam Heated Hose Assemblies. (CH Grade)


CH Hose Assembly

Purpose For use in applications where the temperature of the process fluid must be maintained as it passes through the hose. This is usually required to prevent solidification or an increase in fluid viscosity. Steam heating is preferred to electrical heating in some applications for reasons of availability or safety, but is less controllable. Description The heating element comprises a small diameter PTFE heating hose, 1/4 or 3/8 bore size, with a single SS wire braid. This is spirally wrapped around the hose, with inlet and outlet ports attached, either both at one end or at opposite ends of the hose assembly. In the case of hose assemblies longer than 3 metres, it is usual to have several heating hoses with inlet ports at opposite ends and along the hose. This reduces the effects of temperature loss over the length of the Hose Assembly. The thermal insulation is usually closed-cell silicone foam rubber. The outer cover is a SS wire braid with a rubber cover if necessary. Design Each hose is custom designed and built to suit the requirements of the particular application. The following information is therefore required: Fluid in Hose Assembly Maintained Temperature of Fluid in Hose Temperature of Steam or Fluid in the Heating Hose Min/Max Ambient Temperature Pressure/Vacuum Applied to Fluid External Conditions of Abrasion etc Specifications As for Bioflex GP SS on pages 9 and 10, except that the minimum , bend radius is tripled, and the outside diameter and weight are significantly increased in line with the particular design. Limitations 1 PTFE lined PN10 flange spigots on heated hoses can only have a maximum flare diameter of 50mm, not 63mm. If the hose is hanging, straight or at 90, under its own weight, special construction is required, so advise Aflex Hose accordingly. Minimum CH Hose Assembly Length 750mm.

Inlet/Outlet for Small diameter PTFE heating hose, coiled along hose Steam Connection Silicone foam rubber thermal insulation Outer braid, or other protective cover

Page 34

Bioflex Electrically Trace Heated Hose Assemblies. (ETH Grade)


Purpose For use in applications where the temperature of the process fluid must be regulated as it passes through the hose. In some applications, an additional melt out facility may also be required. Description The heating element comprises either a resistance or selfregulating element spirally wrapped around the hose assembly. Self regulating elements may require a sensor and controller if a
Temperature sensor Silicone foam rubber thermal insulation Heating element coiled along hose

ETH Hose Assembly


Flexible conduit for heating element connection Flexible conduit for temperature sensor connection

specific maintain temperature is required. Please consult Aflex Hose for clarification. Resistance element heated hoses usually also require a temperature sensor to be built in to the construction and must be used in conjunction with a temperature controller. The power leads and (if applicable) temperature sensor leads emerge from the hose assembly at one end, through glands and conduits. The thermal insulation is foam rubber, silicone foam rubber for temperatures above 80C (176F). The outer cover may be a polypropylene yarn or SS wire braid with a rubber cover if necessary. Design Each hose is custom designed and built. Application details must be supplied by filling in an ETH Hose Questionnaire, available from Aflex Hose. Generally, for Hazardous Areas, particularly ZONE 1, the Self Regulating type of heating element is employed, with or without a temperature sensor and control, and flameproof glands and conduit are also required. The watts per metre of the heating element, the pitch of the spiral on the hose, and the thickness of the thermal insulation are all calculated in accordance with established formulae to give the required maintained temperature. Specifications As for Bioflex GP SS on pages 9 and 10, except that the Minimum , Bend Radius is tripled and the outside diameter and weight are significantly increased in line with the particular design. Maximum ETH Hose Assembly Lengths are as Bioflex GP SS. , Limitations 1 PTFE lined PN10 flange spigots on heated hoses can only have a maximum flare diameter of 50mm, not 63mm. If the hose is hanging, straight or at 90, under its own weight, special construction is required, so advise Aflex Hose accordingly. Minimum ETH Hose Assembly Length, when collars are used 750mm.
Outer braid, or other protective cover

Page 35

Bioflex Standard and Puretag Labelling and Colour Coding Sytems


Standard Labelling
All Bioflex hose assemblies are labelled with the following information: - Manufacturers Name (Aflex Hose Ltd) - Hose Size and Grade - Max. Working Pressure - Unique Serial Number - Month & Year of Manufacture - Aflex Hose Telephone Number - CE Mark (if applicable) This information is normally vibro-etched on to a loose stainless steel Ring mounted on the hose. In some cases, at the discretion of Aflex Hose, the information may be etched on to a thin stainless steel plate which is clamped to the hose, or on to the end fitting ferrule at one end. This may be necessary for example, if the customer requires additional information which may not fit on to a Ring. Customers may specify which labelling system they require, and may request additional information on the label.

Puretag Labelling and Colour Coding


This system is only applicable to the EPDM (RC or FP) or Silicone (SI) rubber covered grades of Corroflon. A label and/or Colour Code is encapsulated on to the braid by a transparent rubber cover which is integrally vulcanised and fully bonded to the rubber cover on the hose. Another alternative is an RFID programmable tag, encapsulated in the Rubber (Aflex Hose Flowtag system) - consult Aflex Hose for details. Further information is available on the Puretag product information document on the website.

Colour Coding
This system is applicable to all grades of Bioflex hose. A coloured PTFE spiral strip is wound on to the hose. It can be left loose, or it can be encapsulated under a transparent, heat-shrunk polyolefin sleeve.

Page 36

Correct Hose Configuration & Length Calculations - for Bend Radius


Hose Configuration Requirements
Hose Assemblies are usually connected at both ends in service. They may then either remain in a fixed, or static configuration or in a flexing, or dynamic configuration. Whether static or dynamic, the First Rule concerning the configuration of the hose is that the bend radius of the hose must never be less than the Minimum Bend Radius (MBR) for the hose as listed in the relevant hose brochure. The most common situation when this is likely to occur is when the hose is flexed at the end fitting, with stress being applied to the hose at an angle to the axis of the end fitting. Typically, this happens either because the length of the hose is too short, or because the weight of the hose plus contents creates a stress at an angle to the end fitting. The Second Rule, therefore, if possible, is to design the configuration to ensure that any flexing in the hose takes place away from the end fittings.

(DYNAMIC) CONFIGURATION
INCORRECT - Hose too short Less than MBR

(S TA TI C ) C O N F I G U R A TI O N
INCORRECT - Weight of hose is at 90 to Axis of End Fittings Less than MBR

CORRECT - No flex at end fittings

CORRECT - No flex at end fittings OR

90 Elbow end fittings

Page 37

Correct Hose Configuration & Length Calculations - for Abrasion & Torque
The Third Rule is that the hose configuration should always be designed, and supported where necessary, to avoid any possibility of external abrasion. In some cases, the length, configuration and angle of the hose can be designed to avoid abrasion. In others, static or moving support frames or support wheels are required.

Abrasion

Incorrect - Hose abrasion against hose) Incorrect - Abrasion inside support

Correct - No hose abrasion Correct - No abrasion over support

The Fourth Rule is that the hose must not be subjected to torque, either during connection, or as a result of the flexing cycle. Torque (twist) in the hose can be applied during connection if the hose is accidentally twisted, or if the second end being connected is a screwed connection, and the hose is subjected to torque during final tightening. In a flexing application, if any flexing cycle of the hose occurs in 3 dimensions instead of 2, then torque will also occur:

CORRECT - Flexing movement takes place in 2 dimensions

INCORRECT - Flexing movement takes place in 3 dimensions, so torque is applied

Both Corroflon and Bioflex hose have good resistance to a small level of torque, much better resistance that rubber or SS hose types, but it is still the best practice to take whatever steps are necessary to eliminate torque. If in doubt, consult Aflex Hose.

Page 38

Hose Configurations & Length Calculations - for Length Calculation


Calculating the Hose Length
The formula for calculating the bent section of the hose length around a radius is derived from the basic formula that the circumference of a circle = 2R, where R = the radius of the circle, and = a constant, = 3.142. So, if the hose goes around a 90 bend, which is 1/4 of a full circumference, and the radius of the bend is R, then the length of the hose around the bend is = 1/4 x 2R. Or half way round, in a U-shape, = 1/2 x 2R. Note : In calculating the length of a hose assembly, the (non-flexible) length of the end fittings must be added in, also the length of any straight sections of hose, as in the following example: Example : To calculate the length for a 2 bore size hose with flange end the other 600mm long. Length of Bent Section (yellow) = 1/4 x 2R (334) = 1/4 x 2 x 3.142 x 334 = 525mm Length of top, Straight Section, including the top end fitting length = 600 - 334 = Length of bottom end fitting Total length of Hose Assembly Things to consider (a) A hose will normally take the longest radius available to it to go around a corner, not the MBR! Also - always remember to include the non-flexible end fitting lengths.
334mm

L = 1/4 x 2R

266mm 66mm 857mm


600 - 334 = 266mm 600mm

= = 525 + 266 + 66 =

fittings, to be fitted in a 90 configuration with one leg 400mm long,

L = 1/2 x 2R

R
334mm

cycle, not the least extended. (c) If the configuration is simply too complex for calculation, then obtain a length of flexible tubing of some kind, mark on paper, or a wall, or floor, or both where the connection points will be relative to each other, scaled down if necessary, then manually run the flexible tubing between them with full radii round bends. Measure the extended length, then scale up if necessary to determine the approximate length of the hose. If in doubt, consult Aflex Hose.
RADIUS R = 400 - 66 = 334

End Fitting Length = 66mm

Page 39

lengths for the most extended configuration during the flexing

33

(b) In dynamic applications, remember to always calculate the

400mm

Conditions of Sale
General Aflex PTFE hose products have not been designed or tested to be suitable for use in any Aerospace, Medical Implantation or Radioactive applications and such use is therefore strictly prohibited unless written approval from Aflex Hose Ltd has been given. Aflex Hose Ltd will not accept liability for any failures of the Aflex Hose Products which are caused by customers failing to perform their Responsibilities as specified in these Conditions of Sale. It is the customers strict Responsibility to review all of the usage limitations given for the hose which he intends to use in an application, to ensure that the application conditions are in compliance with those usage limitations. The usage limitations are specified both on this page, in the Full Brochures for the relevant products on the Aflex Hose website. Customers must always consult the latest, up to date information, which is only available and downloadable from the Aflex website. It must be accepted, however, that the usage limitations specified elsewhere in the Hose Product Information and on this page are intended as a guide only, since every possible factor in every type of application cannot possibly be covered. It is therefore the Customers Responsibility to ensure the design suitability and safety of the products in their intended applications, giving particular consideration to the chemical and electrostatic compatibility of the fluids or gases passing through, the possibility of diffusion of fluid or gases through the PTFE hose lining, the possibility of external corrosive conditions, the types and likelihood of excessive mechanical abuse, such as abrasion (internal or external), crushing, excessive flexing or vibrations etc, and any excessive temperature and/or pressure pulsing conditions, all of which may cause premature hose failure. It is also the Customers Responsibility to consider, and take account of the degree of risk involved in any hose failure, including the provision of adequate protection in the event of any risk to employees or the general public. In applications where any type of hose failure would lead to financial losses if the hose is not replaced immediately, it is the Customers Responsibility to order and hold in stock spare hose(s) accordingly. It is also the Customers Responsibility to advise Aflex Hose in writing if there are any special requirements for the hose, including cleaning, or drying, or extra testing requirements which are in addition to normal industrial standards. If the Customer has any doubts concerning these or any other usage limitation or safety parameters, it is the Customers Responsibility to consult Aflex Hose Ltd, to request a written response to any queries. It is the Responsibility of the Customer to ensure that if the product is sold on, or passed on, however many times, that all the necessary information including this page and the Aflex Hose website address are also passed on to the final user, together with a specific requirement that the final user must review the usage limitations in terms of his own application. Hose Service Life It is not possible to guarantee a minimum service life for any of the Aflex Hose products which can be applicable for every type of application. (For example, PTFE lined hose has been used in one application where it was cycled with hot steam, then cold water, also flexed every 17 seconds 24 hours per day, and the customer was very satisfied with a service life of 3 weeks before failure. In other light duty applications carrying pharmaceutical products, however, many Corroflon hoses are still performing satisfactorily after 20 years in service). Service life predictions or guarantees can only be given in cases where all the relevant information concerning the application is given in writing to Aflex Hose, and Aflex Hose subsequently replies in writing prior to the order being placed. If such a written undertaking is not sought and given, then Aflex Hose cannot be held liable for any hose product failure which the customer considers to be premature, excepting failures which are due to faulty materials or manufacturing defects. 2 4 M o n t h Wa r r a n t y Aflex Hose Ltd warrants its products to be free from faulty materials or manufacturing defects from the date of the initial sale, for 24 months. N.B. All ETH hoses are only warranted for 12 months. P r o d u c t Fa i l u r e In the event of a product failure, Aflex Hose requests that the product should not be cut up or tampered with, but should be de-contaminated and returned to Aflex Hose, plus a decontamination certificate, for examination and analysis of the fault. The customer should also provide full details in writing of the application conditions under which the hose failed, including Pressure, Vacuum, Temperature, Flexing and any cycling of any of these, also the fluid and gases passing through the hose, and the total time that the hose has been in service. The customer may send his own witness to the examination if required. Aflex Hose will provide a full Non Conformance Report for the customer. If faulty materials or a manufacturing defect in the hose was responsible for the failure to perform then, the maximum liability to be accepted by Aflex Hose would include the invoice value of the failed hose itself, or the invoice value of the whole customer order if appropriate, also any reasonable costs for removal and replacement of the hose, and costs for packing and despatching the failed hose back to Aflex Hose. Aflex Hose Ltd will not accept liability for any other consequential or financial losses, including, but not limited to loss of profits, loss of products or downtime costs. Untested Hose for Self Assembly by Customers Aflex Hose sometimes supplies loose hose, without end fittings attached to Self Assembly Customers, who will then cut the hose to length and attach end fittings to make up Hose Assemblies. Self Assembly Customers must then accept the responsibility to carry out pressure testing of 100% of such assemblies to 11/2 times the Maximum Working Pressure (MWP) if the hose as listed in the Full Product Brochure before supply for end use, to validate both the hose and the end fitting attachment. When pressure testing hoses with a plastic or rubber outer cover, the cover will mask any signs of leakage for a time. It is therefore recommended that after the Hydrostatic Pressure Test, the hose should be tested at the MWP with air under water for a minimum test period of 5 minutes. Unless the customer requests, and Aflex Hose confirm that their loose hose is pressure tested before supply, such testing is not normally applied by Aflex Hose, because this testing requirement is satisfied by the Self Assembly Customer during his own testing of the finished Hose Assembly. The Self Assembly Customer must also accept responsibility for determining and approving the Design Suitability of the hose assemblies for their intended use before supply. This includes determining and requesting or applying any special tests which may be identified as necessary to ensure suitability for the intended use. Aflex Hose will only accept liability for its hose products which are assembled by Aflex Approved Self-Assembly Companies if all the hose and fitting components were supplied by Aflex Hose or approved for use by Aflex Hose, and they were assembled and tested in accordance with Aflex Hoses current Manufacturing and Testing Instructions, available to approved Self Assemblers in an I-Bay on the Aflex Hose website. Untested Hose Assemblies Aflex Hose is sometimes requested by customers to attach non-standard end fittings to hose assemblies which they supply, and in some cases it is not possible to connect these fittings to the pressure test system. In such cases a Concession not to test is obtained from the Customer, and a label is attached to the hose assembly, warning that it requires pressure testing before use. Fo r c e M a j e u r e Aflex Hose Ltd shall not be liable for any delay or default in performing in accordance with any Customers order if the delay or default is caused by conditions beyond its control, including, but not limited to wars, insurrections, strikes, natural disasters or performance failures by Carriers, sub-contractors or other third parties outside the control of Aflex Hose Ltd. Legal System These Conditions of Sale are subject to English Law.

Page 40

The Worlds Leading Manufacturer of PTFE Flexible Hose.


Spring Bank Industrial Estate, Watson Mill Lane, Sowerby Bridge, Halifax, West Yorkshire HX6 3BW Tel: +44 (0) 1422 317200 Fax: +44 (0) 1422 836000 Website: www.aflex-hose.com

Certificate No. 1977

UK BIOFX/01.02.11 Rev 13