Page No.
Revision
Engineer JdL Date May 2018
Checked Date
Job No. 31033 W/S Job Title GMT Phase2 parking structure block C
Subject GMT Phase 2 parking structure Block C - 10m span - 350 slab
Reinforced Concrete Slab
Location Span reinforcement
Forces Slab Dimensions
Maximum Moment M = 40 kNm/m Slab depth 200 mm
Tension reinft cover 25 mm
Comp. reinft cover 25 mm
Material Properties Span of slab 1.5 m
Characteristic strength of tension reinforcement fy = 460 N/mm2
Concrete Strength fcu = 30 N/mm2
Compression and Tension Reinforcement
Effective depth (tension reinft) d= 167 mm
Effective depth (comp reinft) d' = 30 mm
k= 0.048 No compression reinft. required
Lever arm z= 157.6 mm
x= 20.9 mm
Tension Reinforcement
Required tension reinforcement Areq = 581 mm2/m
Provided tension reinforcement Aprov = 1005 mm2/m Provide T 16 s @ 200 cts
Tension reinforcement ok
Compression Reinforcement
Required tension reinforcement As' = 0 mm2/m
Provided tension reinforcement As'prov = 393 mm2/m Provide T 10 s @ 200 cts
Compression reinft ok
Deflection
Basic span/effective depth ratio 27
Design service stress fs = 177 N/mm2
Tension modification factor 1.62
Compression modification factor 1.07
Modified span/effective depth ratio 46.9
Actual span/effective depth ratio 9.0
Span/effective depth ratio ok
REINFORCED CONCRETE SLAB DESIGN In accordance with BS 8110 : Part 1 : 1997
Job Title:
Job Number:
Beam reference:
Forces Beam Dimensions
Maximum moment M= 40.0 kNm/m Depth
Tens. reinft cover
Material properties Comp. reinft cover
460 N/mm
2
Char. strength tension reinft fy = Span
Concrete strength fcu = 30 N/mm2
Compression and Tension Reinforcement
Effective depth to tension reinft d= 167.0 mm
Effective depth to comp.reinft d' = 30.0 mm d'/x = 1.436127
k= 0.048 No compression r
Lever arm factor 0.944
Lever arm z= 157.6 mm
x= 20.9 mm
Reduced char. strength comp reinft not reqd N/mm2
Tension reinforcement
Tension reinforcement required As = 581 mm2/m
Tension reinforcement provided As prov = 1005 mm2/m Provide
Compression reinforcement
Compression reinforcement required As' = 0 mm2/m
Compression reinforcement provided As' prov = 392.6991 mm2/m Provide T
Max shear stress 4.38178
400/d 2.39521
Shear link spacing s= mm
Deflection
Basic span/effective depth ratio 27
Design service stress fs = 177 N/mm2
Modification factor (tension reinft) 1.620279
Modification factor (compression reinft) 1.072686
Modified span/effective depth ratio 46.9
Actual span/effective depth ratio 9.0
Minimum tension reinforcement As min = 217 mm2
Minimum compression reinft. As' min = 0 mm2
200 mm
1000
25 mm
25 mm
1.5 m
No compression reinft. required
16 @ 200 CTS
Tension reinforcement ok
10 @ 200 CTS
Compression reinft ok
Span/effective depth ratio ok
Pass