DSE9476 Data Sheet
DSE9476 Data Sheet
DSE9476 SPECIFICATIONS
DC OUTPUT
DSE9476 OUTPUT
20 A DC at 24 V DC
REGULATION
LINE
<0.5%
LOAD
1%
PROTECTIONS
Short Circuit
DC Under & Over Voltage
DC Over Current
Reverse Polarity
Over Temperature
AC Under & Over Voltage
RELATED MATERIALS
TITLE PART NO.
DSE9400 Series Configuration Suite PC Software Manual 057-159
DSE Configuration Suite Installation & Operator Manual 057-151
DSE9476 Installation Instructions 053-235
DSE9400 Operator Manual 057-085
ELECTRO-MAGNETIC COMPATIBILITY
INTELLIGENT BATTERY CHARGER BS EN 61000-6-2
EMC Generic Immunity Standard for
The DSE9476 intelligent battery The chargers do not include any OPERATING TEMPERATURE RANGE
charger can be programmed for moving parts to give added durability BS EN 60068-2-1
Ab/Ae Cold Test -30 ºC
different charging curves to maximise and reliability. They will also continue BS EN 60068-2-2
the life of the battery. to operate during engine cranking and Bb/Be Dry Heat +80 ºC
running. * Refer to de-rating curve in the DSE9476
The DSE9476 is programmed using Operator Manual
the user-friendly DSE Configuration Multiple chargers can be linked VIBRATION
Suite PC software. together to provide a larger current BS EN 60068-2-6
output. Ten sweeps in each of three
major axes
The charger is mounted to the chassis 5 Hz to 8 Hz ar +/-7.5 mm,
using the fixing holes that are built 8 Hz to 500 Hz at 2 gn
into the case. The chargers’ stylish
HUMIDITY
design includes three coloured LEDs
BS EN 60068-2-30
to indicate charging status and fault Db Damp Heat Cyclic 20/55 ºC
conditions. at 95% RH 48 Hours
BS EN 60068-2-78
Cab Damp Heat Static 40 ºC
at 93% RH 48 Hours
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS