Bid Plan - Avery
Bid Plan - Avery
Bid Plan - Avery
ARCHITECTURAL
A1
A2
LAND USE AND ZONING
A3
EA
ING AR
PARK
ARCHITECTURAL
STRUCTURAL
ELECTRICAL
SANITARY
MECHANICAL
1 2 3
10000
2000 2325 3675 2000
20AT 2P
2000
2000
SCHEDULE OF LOADS AND COMPUTATION
A LEGEND : CKT. NO. L.O. C.O. OTHERS VOLTS VOLT AMPERE AMP ACB SIZE WIRE CONDUIT
1 8 230 1600 6.96 20A 2 - 3.5 mm² THHN
20 mm Ø
SERVICE ENTRANCE ACU OUTLET 2 4KW RANGE 230 4000 17.39 20A
1 - 3.5 mm² THHN
2 - 5.5mm² THHN
25 mm Ø
1 - 3.5mm² THHN
3400
3400
S1 S1
M KILOWATT HOUR METER RANGE OUTLET 3 REF 230 1000 4.35 20A 2 - 3.5 mm² THHN
1 - 3.5 mm² THHN 20 mm Ø
S1
6
CONVENIENCE OUTLET REFRIGERATOR OUTLET 4 ACU 1.5HP 230 2310 10.04 20A 2 - 3.5 mm² THHN
1 - 3.5 mm² THHN 20 mm Ø
2 - 3.5 mm² THHN
20 mm Ø
B S1
E.F. EXHAUST FAN WEATHERPROOF OUTLET 5
6 14
ACU 1.5HP 230
230
2310
1400
10.04
6.08
20A
20A
1 - 3.5 mm² THHN
2 - 3.5 mm² THHN
20 mm Ø
1 - 3.5 mm² THHN
12000
12000
S1
LIGHTING OUTLET ELECTRIC SERVICE ENTRANCE 7 SPARE 230 1000 4.35 20A
3600
TOTAL 14,620 63.56
S1 SINGLE SWITCH TELEPHONE OUTLET COMPUTATION : APPLY 80% DEMAND FACTOR
S3
S2 DOUBLE SWITCH VA
C S3 3 GANG SWITCH
CABLE TV OUTLET I =
230
14,620
x 80% + 25% ( 10.04 )
I = x 0.80 + 2.51
S4 4 WAY SWITCH 230
3000
3000
IT = 53.36 AMPERES
ELECT. PANEL BOARD
USE 2 - 60 mm² THW WIRE AND 1 - 14 mm² TW WIRE IN 50 mm Ø RSC PIPE
ALSO USE 60AT 2POLE CIRCUIT BREAKER AS MAIN
DISCONNECTING MEANS.
2000 2325
10000
3675 2000
RISER AND POWER DIAGRAM ELECTRICAL NOTES:
LIGHTING LAYOUT 1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN
GROUND FLOOR PLAN
SCALE
1 : 100M ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, THE APPLICABLE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
FROM MECO SOURCE THE RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITY AND
THE REQUIREMENTS OF THE LOCAL POWER, TELEPHONE AND
1 2 3 COMMUNICATION COMPANIES.ALL ELECTRICAL WORKS HEREIN SHALL BE
10000 2 - 14 mm²/ 1 - 5.5 mm² UNDER THE DIRECT SUPERVISION OF A DULY LICENSED PROFESSIONAL
2000 2325 3675 2000 THW WIRE IN 25mmØ RSC ELECTRICAL ENGINEER, REGISTERED ELECTRICAL ENGINEER,OR A
230V / 115V
1Ø 50Hz REGISTERED MASTER ELECTRICIAN
M
2000
2000
2. UTILITY VOLTAGE TO THE UNIT SHALL BE SINGLE PHASE, 2 -WIRES, 230V, 60HZ, 2P.
3400
4
CONDUITS SHALL BE USED WHERE REQUIRED. MINIMUM SIZE OF CONDUITS
SHALL BE 15mm INTERNAL DIAMETER.
20A 20A
B 1
C.O. 1 2 RANGE 4. ALL WIRES SHALL BE COPPER, PVC INSATLLED AND NYLON JACKETED TYP
E "THHN" UNLESS OTHERWISE INDICATED. THE MINIUM SIZE FOR POWER
12000
12000
3600
3
5. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF
#8 HOME RUN
20A 20A THE SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY AND
C ACU 5 6 LIGHTS
ALSO THE ACTUAL LOCATION OF THE TELEPHONE SYSTEM ENTRANCE FOR
CONNECTION TO THE LOCAL TELEPHONE CABLE FACILITIES
3000
3000
SPARE 7 20A 20A 8 SPARE 6. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS:
ELECT. POST a.) LIGHT SWITCHES 1.40m ABOVE FLOOR FINISH
PB 12mm x 3.00
GROUND ROD
b.) CONVENIENT OUTLETS
c.) TELEPHONE OUTLET
0.30m
0.30m
do / as required
do / as required
2000 2325 3675 2000
d.) PANEL BOARDS AND CABINETS 1.40m do / AT CENTER
BUNGALOW
10000
2
BUILDINGS WHETHER EXECUTED PARTLY OR WHOLE.
LIC. NO.: PTR NO.
SECTION 25 RA 545 GOVERNORS DRIVE, GENERAL TRIAS, CAVITE
ISSUED AT: ISSUED ON: APPROVED FOR THE OWNER:
TO SERVICE EQUIPMENT
2
BUILDINGS WHETHER EXECUTED PARTLY OR WHOLE.
LIC. NO.: PTR NO.
SECTION 25 RA 545 GOVERNORS DRIVE, GENERAL TRIAS, CAVITE
ISSUED AT: ISSUED ON: APPROVED FOR THE OWNER:
GENERAL NOTES FOR PLUMBING :
1. ALL PLUMBING WORKS INDICATED HEREIN SHALL MEET THE PROVISIONS OF THE PLUMBING CODE OF THE PHILIPPINES,
THE NATIONAL BUILDING CODE & THE RULES & REGULATIONS OF CITY MUNICIPALITY.
LEGEND: 2. PLUMBING CONTRACROR SHALL COORDINATE THE DRAWINGS WITH THE RELATED DRAWINGS & SPECIFICATIONS &
WC WATER CLOSET NOTIFY THE CONSULTING ENGINEER OF ANY DISCREPANCY FOUND THEREIN.
LAV LAVATORY 3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER
FAU FAUCET TRADE SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
H.B. HOSE BIBB 4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH & INVERT ELEVATIONS OF ALL
S.S. SOIL STUCK EXISTING PIPES & STRUCTURES AS VERIFIED BY THE CONTRACTOR.
M.H. MAN HOLE 5. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE & COORDINATE THE WORK WITH THE SEWER LINE
F.D. FLOOR DRAIN EFFICIENT DISPOSAL POINT & WATER LINE SERVICE CONNECTING LINE
C.B. CATCH BASIN 6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% MINIMUM UNLESS OTHERWISE SPECIFIED.
CWL COLD WATER LINE 7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS.
VTR VENT THRU ROOF 8. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
DC DIGESTIVE CHAMBER
LC 9. ALL PIPE SIZE & DIMENSION ARE IN mm.
LEECHING CHAMBER
10. ALL PLUMBING WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISIONS OF A DULY LICENSED SANITARY
ENGINEER OR MASTER PLUMBER.
SANITARY LAYOUT
PVC
P-TRAP
2
BUILDINGS WHETHER EXECUTED PARTLY OR WHOLE.
LIC. NO.: PTR NO.
SECTION 25 RA 545 GOVERNORS DRIVE, GENERAL TRIAS, CAVITE
ISSUED AT: ISSUED ON: APPROVED FOR THE OWNER:
UNION PATENTE WATER
LENGTH METER
MH MH CHECK VALVE HOSE BIBB
0.15 2L/3 L/3 0.15
REDUCER
@ 0.20m. O.C., B.W.
0.30
UNION
0.35
INLET
0.40
0.15
0.15 AIR SPACE PATENTE
W/2
SCUM LEVEL
1.80 M.
OUTLET
MANHOLE MH
WIDTH
DIGESTION CHAMBER
LEACHING CONCRETE SUPPORT
CCIP WATER LINE
MH CO WELL
CO @ 0.20m. O.C., B.W. CCIP WATER LINE
W/2
MANHOLE FIN. FLR. LVL.
MH
L = 1.80 M
0.15
0.15
.15
PLAN W= 1.40 M CL
SECTION
FROM SERVICE WATER
ISOMETRIC LAY-OUT
SCALE 1 : 50 METERS
2
BUILDINGS WHETHER EXECUTED PARTLY OR WHOLE.
LIC. NO.: PTR NO.
SECTION 25 RA 545 GOVERNORS DRIVE, GENERAL TRIAS, CAVITE
ISSUED AT: ISSUED ON: APPROVED FOR THE OWNER:
D. NOTES ON FOUNDATION
A. GENERAL NOTES:
BUNGALOW
ROOF FRAMING PLAN
SCALE 1 : 100M
TABLE 2
TABLE 1
BUNGALOW
FOUNDATION PLAN
SCALE 1 : 100M
1
BUILDINGS WHETHER EXECUTED PARTLY OR WHOLE.
LIC. NO.: PTR NO.
SECTION 25 RA 545 GOVERNORS DRIVE, GENERAL TRIAS, CAVITE
ISSUED AT: ISSUED ON: APPROVED FOR THE OWNER: