KingPigeon-K4 Manual
KingPigeon-K4 Manual
KingPigeon-K4 Manual
The GSM Elderly Care Alarm System is a new released smart solution for take care of
senior, aged, elder or disabled people on their daily life.
Big LED display temperature and time, easy setting by smart phone APP and installed
for house, the system helps users to know if there have fall down incident, SOS help,
emergency alarm from families, and smoke, gas, water leakage alarm of the house,
indoor temperature, or if elderly didn’t get up on time by SMS text, etc.
Nowadays, the aging trend is very serious in all countries, and lots of seniors living
alone, the elderly care system well used for take care of families by the advanced and
reliable technology.
Elderly Care Alarm System
Applications
Elderly living care, Home Safety, SOS call, Emergency call
Nurse room, Care center, Telecare
Microphone Push-to-Talk
Just push the SOS button then make a phone call with families or ask for help.
The system auto answering phone call from White List numbers (or all numbers optional).
Bottom View
Daily life care
5 6 7
8 You can receive the alert SMS text if no activities detected by sensors during the
4 3 2 1 monitoring time period.
For example, install one door contact sensor on the main gate, setting time period at
16:00~18:00pm,if the main gate not opened during that time, you will get alert SMS.
1
3 Temperature monitoring
4 You can receive the alert SMS text when indoor temperature is too hot or too cold.
1 2
Wiring and Start Setting Confirm the Panel’s SIM Card Number
Using smart phone APP is easy and simple-- search Senior Helper on Google Play store,
download and install the APP to your Android Smart phone for configuration.
Trying to send SMS
You can also send SMS commands as below explanation to configure the system.
The 1234 on below SMS commands is default password, change it to your new password #
SMS Command:
1234L the Panel's SIM Card Number #
The panel can get mobile operator's date & time according to the phone number,
LED will correct and display the real time after few minutes when setting done.
If it can't get correct date & time automatically, please try to remove or add the
country code, for example, setting 0086 13510150873 or +86 13510150873
instead of 13510150873.
3 4
Alarm Receiver and White List Numbers Zone Alarm SMS Content (Zone name)
Inquiry:
Inquiry: 1234 B00 #
1234A# ...
1234 B16 #
Delete:
123401A# Delete Zone alarm SMS Conten:
... 1234 B00 ##
1234 10A# ...
1234 B16 ##
The position 1~3 used for alarm receiver too, these 3 numbers can receive
1. Zone number 00 is the SOS button on the panel, default: no SMS, means when press
alarm SMS text and phone call when alarm occurrence.
the SOS button, system makes phone call for talk only.
Who can call in to talk 2. If no alarm SMS content on the zone(SMS Command: 1234Bxx##), means alarm
call only when this zone alarming.
3. Alarm SMS content max. 40 characters.
SMS Command:
Allow all numbers can call in (default)
1234CC Default Zone alarm SMS content:
00: (default: no SMS) ---For the SOS button on panel.
Only the White List numbers can call in (Caller-ID)
01: Has not got up bed alarm! ---For monitoring sensor.
1234DD
02: Fall Down Alarm! ---For EM-90 fall down sensor/SOS pedant.
When call in, the panel answers(picks up) phone call 03: Smoke Detector Alarm! --- For SM-100 Smoke detector (*optional).
automatically after two rings. 04: Water Leakage Alarm! — For WL-100 Water Leakage detector (*optional).
If you enable the Caller-ID(only the white list numbers 05: Gas Leakage Alarm! — For GL-100A Gas detector (*optional).
can call in to talk), then the panel will identify the last 4 06: Panic Help Alarm! — For EM-60/70/100/100B/YK series buttons(*optional).
digits of the call in phone number to decide to “answer”
07: SOS Ask For Help! --For EM-60/70/100/100B/YK series buttons(*optional).
or “reject”.
...
16: SOS Ask For Help! -- For EM-60/70/100/100B/YK series buttons(*optional).
5 6
Get up Monitoring Time Temperature Alarm Threshold
Example on the APP screen shot is: For example, 1234T#L 016 #H 028 #
1234Q 0530 # 0820 #
When temperature higher/lower than the threshold
Disable the Get up Monitoring Alarm: more than 10 minutes, the 1st alarm receiver will get
The special zone type for take care of elderly, FIXED in the zone number 1 only. Inquiry SMS Commands
The purpose of this Monitoring Zone:
SMS Command:
Take care of elder people’s activities on daily life.
?
You can get reply message with the SMS command list.
For example, install one wireless door sensor at your Dad’s bed room, setting the
monitoring time period at 05:30~08:20, If he didn’t get up (didn’t open his door) during
that time, system sends alert SMS “Has not Get Up!”, make audible alarm and alarm
call. Reset
You can also edit the SMS text as you like, i.e.: “Dad did not get up yet.”
Press and hold the UP and DOWN button on back side, switch ON, and release the buttons
Recommend sensors: when LED shows RESET.
Wireless door sensors, Curtain PIR motion sensors. Reboot the panel, system enter to factory mode.
Caution: All phone numbers, wireless sensors and other parameters will be removed.
7 8
Add Wireless Sensors Safety Directions
Change sensor:
If you need to change sensor on an existing zone (LED shows xx USE ), press the
Avoid Use at Gas Station
SET button, LED shows xx --- , then you can add a new sensor to this zone. Do not use the alarm system at a gas station. Power off
it when near fuels or chemicals.
Exit Learning mode:
On Learning mode, press and hold SET button for 3 seconds.
Power it off near Blasting Places
Please follow relevant restrictive regulations. Avoid using
Default SMS Content the device in blasting places.
9 10
Specifications Trouble Shooting
No GSM signal
GSM Frequency Quad-band 850/900/1800/1900 MHz
1)Backup battery low voltage.
Wireless Zones 16 2)GSM Module connection loose in transportation.
Radio Frequency 433.92MHz 3)GSM Signal is too weak.
Solution
Rated Power Supply 9~24V DC/1A 1)Plug the AC/DC Power adapter.
Power Consumption 12V input, Max. 270mA, Standby 30mA 2)Please take the panel to a mobile phone repair store, and then ask the engineer
SIM Card Support 3V SIM Card to check the GSM Module socket and the GSM Module connection.
3)Please change another location to install the alarm panel.
Antenna 50 Ω SMA antenna interface
Temperature Range -20~+60 °C Auto Restart– Backup battery low voltage.
Humidity Range Relative humidity 90% (condensing free) Solution – Plug the AC/DC Power adapter.
Backup Battery 3.7V/900mAH Li-ion rechargeable False Alarm – PIR Motion sensor installation incorrect.
Exterior Dimension 13*13*2.7 cm (5.12*5.12*1.06 inch) Solution -- Please install the PIR sensor according to the user manual carefully.
Net Weight 200 g (0.44 lb)
No SMS/Call when alarm,No action when you send SMS command
1)GSM Operator communication protocol.
2)Didn’t setup SMS Alert/Call receiver’s phone umbers.
Packing List 3)Caps Lock letters in the SMS.
Solution
Main unit *1 1)Change another GSM Operator SIM Card for test.
Wireless Fall detector EM-90 *1 2)Setting SMS Alert/Call receiver’s phone umbers correctly, e.g.: country code.
3)Check the commands with CAPS LOCK and correct format.
Wireless PIR Motion sensor *1
Power supply: AC/DC12V/1A *1 Can not call in to the alarm panel
User manual *1 1)Country code incorrect.
Packing size: 15*14*9 cm (5.9*5.5*3.5 inch) 2)GSM Signal too weak.
Gross weight: 500 gram (1.1 lb) Solutions
1)Check and ensure the country code format, e.g.: 0086 or +86.
2)Please put the alarm panel in strong signal coverage area.
11 12