D.10 E.1 Jembo STD INQ 1259 PT. Gracia Dikatamas

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

PDV/1259 /2021

To : PT. Gracia Dikatamas

Schedule of Technical Data

Date 8-Sep-21 Rev. 0


FOR APPROVAL
Prepared

Budi Darmawan
Engineer

Checked

Anggono
Supervisior

Approved

Praptono Hadi Prasetyo


Manager
Rev. : 0

TCU/XLPE/SWA/PVC-FL IEC 60228, IEC 60502-1


Schedule of Technical Data
0.6/1 (1.2) kV IEC 60332-3/C

1 1. Conductor : Tinned Annealed Copper wire class 2


2. Insulation : Extruded XLPE
2
3. Inner Sheath : Extruded PVC-FL Cat C (Black Colour)
4. Armour : Galvanized Steel Wire
3
5. Outer Sheath : Extruded PVC-FL Cat C (Black Colour)
4

Core identification :
5
- 3 Cores : Red, Yellow, Black

Marking by Ink Jet Printing :


e.g. IEC 60502 60332-3/C JEMBO CABLE TCU/XLPE/SWA/PVC-FL 3 x 4 mm² 0.6/1 kV "Year" "Length Marking"
Length Marking by Ink Jet Printing with interval every 1 meter

CONSTRUCTION
Conductor Insulation Inner Sheath Armour Outer Sheath Approx. Approx.
Standard
Item Number Nominal Size No of Shape Approx. Nom. Nom. Nom. Nom. OD Cable Length per
drum/coil
wire dia. Thickness Thickness Diameter Thickness of Cable Weight

sqmm - - mm mm mm mm mm mm kg/km m

AT2XRY00003004MI 3x4 7 rm 2,49 0,7 1,0 0,80 1,8 15,8 486 1000

rm : Round Stranded
- Tolerance of overall diameter : OD ≤ 20 mm : ± 1.0 mm, OD ≤ 40 mm : ± 2 mm, OD > 40 mm : ± 5%

CHARACTERISTICS

Max. DC Short Circuit AC


Min. Insulation Current Carrying Capacity at 30ºC
Conductor
Item Number Nominal Size Resistance at Current at Voltage
Resistance at
20°C
20°C In Ground In Air 1 sec. test

sqmm Ohm/km M.Ohm.km A A kA kV / 5 min.

AT2XRY00003004MI 3x4 4,7 1.800 36 42 0,53 3,5


- Minimum bending radius:
- Installed : 12 x OD
- Standard packing : wooden drum
Rev. : 0
NYRGbY (Tinned)
Schedule of Technical Data IEC 60228, IEC 60502-1
0.6/1 (1.2) kV

1 1. Conductor : Tinned Annealed Copper wire class 2


2. Insulation : Extruded PVC
2
3. Inner Sheath : Extruded PVC (Black Colour)

3 4. Armour : Galvanized Steel Wire and Tape


5. Outer Sheath : Extruded PVC (Black Colour)
4

Core identification :
5
- 3 Cores : Red, Yellow, Black

Marking by Ink Jet Printing :


e.g. IEC 60502 JEMBO CABLE NYRGbY (Tinned) 3 x 6 mm² 0.6/1 kV "Year" "Length Marking"
Length Marking by Ink Jet Printing with interval every 1 meter

CONSTRUCTION
Conductor Insulation Inner Sheath Armour Outer Sheath Approx. Approx.
Standard
Item Number Nominal Size No of Shape Approx. Nom. Nom. Nom. Nom. OD Cable Length per
drum/coil
wire dia. Thickness Thickness Thickness Thickness of Cable Weight

sqmm - - mm mm mm mm mm mm kg/km m

ATYRGbY0003006MI 3x6 7 rm 3,06 1,0 1,0 1,3 1,8 19,9 869 1000

rm : Round Stranded
- Tolerance of overall diameter : OD ≤ 20 mm : ± 1.0 mm, OD ≤ 40 mm : ± 2 mm, OD > 40 mm : ± 5%

CHARACTERISTICS

Max. DC Current Carrying Capacity at Short Circuit AC


Min. Insulation
Conductor 30ºC
Item Number Nominal Size Resistance at Current at Voltage
Resistance at
20°C
20°C In Ground In Air 1 sec. test

sqmm Ohm/km M.Ohm.km A A kA kV / 5 min.

ATYRGbY0003006MI 3x6 3,11 40 36 43 0,65 3,5


- Minimum bending radius:
- Installed : 12 x OD
- Standard packing : wooden drum

,
Rev. : 0

Schedule of Technical Data TCU/XLPE/OS/PVC


BS EN 50288-7
INSTRUMENT CABLE 300/500 V

1. Conductor : Tinned Annealed copper wire class 2


2. Insulation : Extruded XLPE
1
3. Overall Screen ( OS ) : Helically Overlapped Polyester Tape
Tinned annealed copper wire 0.5 mm² (20/0.18)
2
Helically overlapped single coated aluminium tape
contacted with drain wire
3
Helically Overlapped Polyester Tape
4. Outer Sheath : Extruded PVC (Black Colour)
4

Core identification :
- Multi Pair : Black and White with Numbering

Marking by Ink Jet Printing :


e.g. BS EN 50288-7 JEMBO CABLE TCU/XLPE/OS/PVC 2 x 2 x 2,5 mm2 300/500 V "Year" "Length Marking"
Length Marking by Ink Jet Printing with interval every 1 meter

CONSTRUCTION

Conductor Insulation Outer Sheath Approx. Approx.


Standard Length per
Item Number Nominal Size No of Shape Approx. Nom. Nom. OD Cable
drum
wire dia. Thickness Thickness of Cable Weight

sqmm - - mm mm mm mm kg/km m

AT2XOY0002P205MB 2 x 2 x 2,5 7 rm 1,95 0,7 1,8 16,2 269 1000

rm : Round Stranded (Class 2)


Tolerance of overall diameter : OD ≤ 20 mm : ± 1.0 mm, OD ≤ 40 mm : ± 2 mm

CHARACTERISTICS

AC
Max. DC Conductor Min. Insulation
Item Number Nominal Size Voltage
Resistance at 20°C Resistance at 20°C
test

sqmm Ohm/km M.Ohm.km V / 1 min.

AT2XOY0002P205MB 2 x 2 x 2,5 7,76 1.000 2.000


- Minimum bending radius:
- Installed : 12 x OD
- Standard packing : wooden drum