TECHNICAL DATASHEET
OneProd VMS
Monitoring Case
8 to 32 channels
www.oneprod-system.com
TABLE OF CONTENTS
2. PICTURES......................................................................................................................................... 4
www.oneprod-system.com
1. General Presentation of the product
The OneProd VMS (Versatile Monitoring Station) monitoring case is built up around the
OneProd MVX acquisition and processing unit.
Its application-oriented functions turn it into a powerful multichannel tool that is readily available,
easy to carry and implement at a moment’s notice.
OneProd VMS allows performing temporary signal acquisition and/or monitoring operations on a
machine.
OneProd VMS integrates a OneProd MVX acquisition and processing unit, which results from
01dB-Metravib’s long-time experience in the permanent monitoring of industrial machines in all
domains. The technical specifications of OneProd VMS are then closely linked to those of
OneProd MVX .
OneProd VMS allows for the simultaneous acquisition of up to 32 analogue channels in the 0-20
kHz range, for their storage or for their local processing in order to monitor a machine and/or to
provide data to the OneProd XPR predictive maintenance platform.
Henceforth equipped with the last firmware version (based on OPS4.2) OneProd VMS allows to
catch any transient phenomena and to record the corresponding signals, before and after the
triggering event.
OneProd VMS is available with 8, 16, 24 or 32 channels and can be customised with several
options:
WIFI communication
GSM communication
Relay outputs
Insulated DC input modules
OneProd VMS is compatible with IEPE transducers, AC or DC signals (/- 20V range) and 4-
20mA signals.
The 32 analogue measurement inputs are available as BNC connectors inside the case.
OneProd VMS includes an energy supply (about ½ hour) aiming at compensating for a
momentary power shortage. This function proves particularly interesting when one wants to
capture a phenomenon that may result from a power outage or that can generate a power
outage itself.
OneProd VMS can operate while it is closed and locked in a humid or dusty atmosphere: cables
are inserted in the case through protected raceways.
A laptop computer can be installed in the case for local use or to operate in closed mode inside
the case, which is closed itself.
For easier transport, OneProd VMS includes a telescopic handle and wheels.
3 EN_VMS_DATA_SHEET.DOC
2. Pictures
Anti-dust cable
raceway
Visual display
LEDs
Supporting areas
for the laptop
Main panel :
Connections
Display
Control
Compartment dedicated
to peripherals: power
supply, relays, options
(MODEM, isolators...)
Relays
4 EN_VMS_DATA_SHEET.DOC
Cable passing
areas
Telescopic handle
(retracted position)
Air outlet
Locking
Air inlet
eyelet
Optional bag to
carry cables
Telescopic handle
(Pulled-out position)
Wheels
5 EN_VMS_DATA_SHEET.DOC
3. Block diagram
Direct connection
to XPR
MODEM
(option)
Visual display
Terminal boxes panel
UPS
RS485
24V DC AC mains Up to 32 transducers Logical inputs-Outputs Modbus
6 EN_VMS_DATA_SHEET.DOC
4. Physical and environmental features
4.2. Connections
Parameterizable analogue inputs
o Female BNC connectors
Logical inputs-outputs and RS 485 connection
o Removable screwed-on terminals
o Wire cross-section: from 0.2 to 2.5 mm² (28 – 12 AWG)
o Tightening torque of the screws: 0.5 Nm
Ethernet connection
o 2 x RJ45 connectors
7 EN_VMS_DATA_SHEET.DOC
5. Electrical features
AC source:
o Voltage: 85...264 VAC (from 47 to 63 Hz)
o Consumption under 230 V: 0.6 A
o Recommended protection: 5 A (characteristic C or slow fuse)
o Connectors: European 3p plug with provided cable
DC source:
o Voltage: 24V +/-5%
o Consumption: 2.5 A max
o Connectors: remouvable screwed-on terminals
This battery is charged from the AC mains during the normal operations of the case.
However the battery is not recharged when OneProd VMS is powered by a DC source.
8 EN_VMS_DATA_SHEET.DOC
5.3.4. Tacho input
Input impedance: > 60 kOhms
Maximum voltages: +/- 23.5 V
Low cut-off frequency: 0 Hz
Lowest measurable frequency : 0.2 Hz
Number of pulses per revolution: from 1 to 65535
The first two inputs can be activated locally using switches located on the control panel inside
the case.
All OneProd VMS logical inputs can be activated remotely by closing a dry contact.
The relay output dry contacts are available on the screw terminals.
24Vdc: 140 W
48Vdc: 20 W
60Vdc: 18 W
110Vdc: 23 W
220Vdc: 40 W
250Vac: 1500 VA
9 EN_VMS_DATA_SHEET.DOC
6. Operating
These indicators are also available “as they come along” in MODBUS format on the Ethernet
and RS485 ports of OneProd VMS , in order to be read by a display or storage system. These
measurements are not stored in OneProd VMS .
Since V5.xxx firmware version, OneProd VMS is able to achieve in real time some indicators,
which means that 100% of the corresponding signals is really monitored.
Besides this real time monitoring function, specific “time wave on event” signals can be
recorded. These signals can include what happened before the trigger event (pre-trigger
function).
The transfer of the recorded signals and indicators to the database occurs as soon as possible,
depending on the network availability. Measurements are stored in OneProd VMS as long as the
data transfer to OneProd XPR is not effective.
In all cases, signal acquisitions are regrouped by machines and they can be subjected to the
operating conditions of the machine.
10 EN_VMS_DATA_SHEET.DOC
Stand-alone monitoring:
o OneProd VMS performs monitoring measurements only.
o OneProd VMS computes scalar indicators only.
o OneProd VMS is set up using the OneProd CSM tool.
o Once set up, OneProd VMS is a full stand-alone system.
o Indicators can be displayed with OneProd VIO .
o Indicators and statuses can be transferred through MODBUS-RTC or
MODBUS-TCP.
The following parameters can be taken into account for each machine:
1 rotation speed
2 DC “process” levels
3 logical input statuses
Parameter Value
Anti-aliasing filtering Yes
Conversion technology Delta-sigma
Number of bits 24
Sampling frequency 51.2 kHz
Size of elementary acquisition blocks 1024 samples, i.e., 80 ms
11 EN_VMS_DATA_SHEET.DOC
6.5. Periodic processing
Parameter Value
Length of time block From 1 second to 255 seconds
None
High-pass 2Hz
(3rd order) 10Hz
3kHz
300Hz
1kHz
Low-pass
2kHz
(3rd order)
3kHz
None
None
Integration Single
Double
RMS
Peak
Detection Peak-to-peak
Equivalent peak
Equivalent peak-to-peak
Average value
Calculation mode Average value of acquisition blocks
Maximum value of acquisition blocks
Bearing defect factor
Kurtosis
Specific processing
SFI (Shock Finder Index)
BGI (Blade Gard Index)
Parameter Value
128Hz ; 256Hz ; 512Hz
Sampling frequency
1.28kHz ; 2.56kHz ; 5.12kHz
(Obtained from decimation)
12.8kHz ; 25.6kHz ; 51.2kHz
12 EN_VMS_DATA_SHEET.DOC
6.5.4. Spectral acquisition
Parameter Value
50Hz ; 100Hz ; 200Hz ;
Frequency range 500Hz ; 1kHz ; 2kHz ;
5kHz ; 10kHz ; 20kHz
400
800
Number of lines
1600
3200
Number of averages From 1 to 4096
Acquisition mode Free or synchronised
Average type linear, exponential, peak
0%
Overlap 50%
75%
2Hz
High-pass filter 10Hz
3kHz
None
Integration Single
Double
None
Zoom factor
x2 ; x4 ; x8 ; x16
Maximum resolution: 30 mHz
x32 ; x64 ; x128
Hanning
Windowing Rectangular
Flat-top
Synchronous analysis Yes / no
RMS level
Fmin
Broad band Equivalent peak level
Fmax
Equivalent peak-to-peak level
13 EN_VMS_DATA_SHEET.DOC
6.6. Alarm processing
Parameter Value
None
High
Alarm modes Low
In window
Off window
Parameter Value
2 Hz
High-pass filter (3rdorder)
10 Hz
1 kHz
Low-pass filter (3rd order)
No (20kHz)
No
Integration
Simple (acceleration to velocity)
RMS
Processing Pick value
Peak-to-peak value
Averaged value (DC value)
Averaging exponential
Time constant: 1s to 25s
BGI (Blade Guard Index)
Specific indicators
GCI (Gearbox Condition Index
broadband
Indicators from Real time FFT
Narrow band
Real time FFT: max frequency 1kHz ; 2kHz ; 5kHz ; 10kHz ; 20kHz
Real time FFT: number of lines 400 ; 800 ; 1600 ; 3200 lines
Real time FFT: overlapping 50%
14 EN_VMS_DATA_SHEET.DOC
6.8. Time wave on event
Besides real time monitoring MVX can record specific time waves that can be trigged at all time
and that includes « pre-trigger » capability. I.e. possibility to include what happened BEFORE
the trigger event.
Other indicators (named « cyclic » ones) are performed after dedicated acquisition period.
When MVX ends cyclic indicators processing, then it starts another acquisition cycle, and so on.
Calculation period for the cyclic indicators depends on global MVX load:
Total number of real time indicators.
15 EN_VMS_DATA_SHEET.DOC
7. Metrological features
16 EN_VMS_DATA_SHEET.DOC
8. Communication
Communication Half-duplex
17 EN_VMS_DATA_SHEET.DOC
9. ORDERING INFORMATION
An AC power cord
A 5-meter Ethernet cable
The OneproD-CSM configuration software
The OneproD-VIO-LV visual display software
The OneproD-CAST software toolbox
User manuals in French and in English (available on a CD-ROM)
The laptop computer delivered with the “PC” package or with the “Full” package includes the
fully pre-installed OneProd-XPR software, as well as a travelling backpack.
18 EN_VMS_DATA_SHEET.DOC
The transducer kit delivered with each “full” pack includes:
As many transducers of type ASH-205B as there are channels in the pack
As many R6W-3-J10-32 (10M, Enviroprene, BNC) cables as there are channels in the pack
A carrying pouch
9.3. Upgrades
OneProd VMS can be upgraded to a more performing model or to a model having more measurement
channels
Please contact 01dB-Metravib.
9.4. Options
Reference Content
Commercial name
code (pre-installed in the case)
MVX3370000 WIFI Option for OneProd VMS 1 WIFI modem
MVX3372000 Insulators Option for OneProd VMS 2 galvanic insulators for Dc signals
MVX3373000 Relay Option for OneProd VMS 4 additional relays
01dB-Metravib
200 Chemin des Ormeaux 69578 Limonest Cedex - France
Tel +33 4 72 52 48 00 - Fax +33 4 72 52 4747