Grundfosliterature 1569
Grundfosliterature 1569
Grundfosliterature 1569
SQFlex
Renewable-energy-based water supply systems
50/60 Hz
SQFlex
2
SQFlex
1
Product data
1. Product data
Performance range
H
[m] SQFlex Solar
220
200
E 1700 W p
180
D 800 W p
160 C 400 W p
B 200 W p
140 A 100 W p
120
100
80
60
40
20 A B C D E
TM022337
0
3
0 10 20 30 40 50 60 70 Q [m /day]
H
[m
SQ Flex Wind
200
180
D 8 m/s
160 C 7 m/s
B 6 m/s
140 A 5 m/s
120
100
80
60
A B C D
40
20
TM022411
0
3
0 10 20 30 40 50 60 70 Q [m /day]
3
1 SQFlex
Applications Pump
Product data
Being designed for continuous as well as intermittent The SQF pump range comprises two pump technologies:
operation, the SQFlex system is suitable for water supply • helical rotor pump (3") for high heads and small flow
applications in remote locations, such as: rates
• villages, schools, hospitals, single-family houses • centrifugal pump (3" and 4") for low heads and large
• farms (livestock watering, irrigation) flow rates.
• game reserves(watering applications) The performance curves below illustrate the pump
performance of the two pump models.
• conservation areas (pumping of surface water)
H
• floating pump installations for water pumping from
ponds and lakes.
SQFlex system
The SQFlex system is a reliable water supply system
based on renewable energy sources, such as solar and
wind energy. The SQFlex system incorporates an SQF
submersible pump. A
Very flexible as to its energy supply and performance, the
B
TM022425
SQFlex system can be combined and adapted to any
need according to the conditions of the installation site.
Q
The system components are:
• SQF submersible pump Performance ranges for helical rotor and centrifugal
pumps
• CU 200 SQFlex control unit
• CIU 903 SQFlex control unit (option for remote
Pos. Description
monitoring)
A Helical rotor pump
• IO 50 SQFlex switch box B Centrifugal pump
• IO 101/IO 101 B SQFlex switch box Q day
• charge controller
All pump types are available in two material variants:
• energy supply system:
• SQF is the standard version made of stainless steel
- solar panels DIN W.-Nr. 1.4301
- wind turbine • SQF-N is made of stainless steel DIN W.-Nr. 1.4401.
- generator
- batteries.
4
SQFlex
1
Motor IO 101/IO 101 B SQFlex switch box
Product data
The motor has been developed specifically for the SQFlex The IO 101/IO 101 B is a switch box designed for
system and is designed according to the permanent- switching the system power supply on and off.
magnet principle with built-in electronic unit. The IO 101/IO 101 B is used in solar-powered SQFlex
The SQFlex 3" motor range comprises different motor systems with a backup generator.
sizes, the MSF 3 with 4 different maximum power input
(P1) ratings of 300 W, 900W, 1400 W and 2500 W. Charge controller
The motor speed range is 3000-10700 min-1 or 500-3600 The charge controller is used when a battery backup
system is installed with an SQFlex pumping system.
min-1, depending on the motor size, power input and load.
The motor is available in two material variants: Solar modules
• MSF 3 is the standard version made of stainless steel The Grundfos solar modules are developed specifically for
DIN W.-Nr. 1.4301 the SQFlex system. The solar modules are equipped with
plugs and sockets enabling easy connection in parallel.
• MSF 3 N is made of stainless steel DIN W.-Nr. 1.4401.
The number of the required solar modules depends on the
The motor has three internal limitations: following:
• maximum power input (P1) • quantity of water
• maximum current of 8,4 A or 12 A • head
• maximum speed of 10700 min-1 or 3600 min-1. • location of installation.
The pump delivers its maximum performance when one of For further information on solar modules, contact
the above limitations is reached. Grundfos.
Supply voltage
Generator
Flexible regarding power supply and power range, the
In case the primary power supply is temporarily
motor can be supplied with either DC or AC voltage:
insufficient, the SQFlex system can be powered by a
• 30-300 VDC, PE (100-300VDC for 2500W motor) diesel- or gasoline generator.
• 1 x 90-240 VAC - 10 %/+ 6 %, 50/60 Hz, PE.
Batteries
CU 200 SQFlex control unit The SQFlex system can be powered by batteries with
CU 200 is a combined status, control and communication a 30-300 VDC voltage supply of and a maximum current
unit designed for the SQFlex system. Moreover, CU 200 of 8.4 A. DC power supply operation is limited to the
enables the connection of a level switch placed in a water highest possible power depending on the voltage. For
reservoir or tank. example, 48 VDC provides a limiting maximum power of
403 W.
CIU 903 SQFlex control unit for remote
monitoring
CIU 903 is a combined monitoring, control and
communication unit designed to work directly with a
SQFlex pump. When combined with a CIM 280 GRM
module, it enables remote monitoring through Grundfos
Go. Moreover, CIU 903 can be connected to a start/stop
switch, a level switch or a pulsating water meter.
It also works with Grundfos GO.
5
1 SQFlex
Sand content
Maximum sand content: 50 g/m3 (50 ppm).
A higher sand content considerably reduces the lifespan
of the pump.
Salt content
The table below shows the resistance of stainless steel to
Cl-. The values in the table are based on a pumped liquid
with a pH value of 5 to 9.
6
SQFlex
1
Product data
The SQFlex system can be used in various combinations.
Charge controller
Optional extras
1)
Wind turbine
Control unit
Solar panels
Pump
SQFlex Solar
IO 50
CU 200 SQ Flex
10 100 SQ Flex
IO 101
CU 200 SQ Flex
10 100 SQ Flex
10 100 SQ Flex
CU 200 SQ Flex
IO 50 or IO
CU 200
101 2)
Pressure switch
CU 200 SQ Flex
CU 200 SQ Flex
1) For the number of the required solar panels, see the sizing tool at Grundfos Product Center.
2) Optional.
7
1 SQFlex
Optional extras
Solar panels 1)
Control unit
Pump
SQFlex Solar
IO 50
CIU 903
Level switch
IO 50
CIU 903
IO 101 B SQFlex
Pressure tank
SQFlex Solar with pressure control
IO 50
CIU 903
Pressure switch
1) For the number of the required solar panels, see the sizing tool at Grundfos Product Center.
8
SQFlex
2
Overload protection
In case the upper load limit is exceeded, the motor
automatically compensates by reducing the speed. If the
speed falls below the minimum speed, the motor stops
automatically.
TM022436
Horizontal installation
9
2 SQFlex
A permanent-magnet motor gives off a small/negligible Low weight ensures user-friendly handling.
amount of heat to its surroundings. In combination with an
• low weight ensuring user-friendly handling.
efficient internal circulation system leading the heat away
from the rotor, stator and bearings, optimal operating • installation in 3", 4" or larger boreholes.
conditions are ensured for the motor. • A motor starter/starter box is not needed.
As an extra protection, the electronic unit has a built-in
• SQF is available with cable and socket.
temperature sensor. When the temperature rises above
85 °C (185 °F), the motor automatically stops. Once the Note: Horizontal installation requires the water level
temperature drops to 75 °C (165 ° F), the motor electrode to be placed minimum 0.3 to 0.6 m (12 to 24 in)
automatically restarts. above the pump to ensure the dry-running protection.
TM022246
2
10
SQFlex
3
Applications
3. Applications
SQFlex Solar
The SQFlex Solar system is the simplest of the SQFlex 12
range. 7
Benefits
The protective circuit incorporated in the motor electronic
unit stops the pump in case of dry running or similar
situations.
By using the IO 50, the power supply to the pump can be
switched off manually, for example in the following cases:
6 5
• There is no need for water supply.
• The system requires service.
Other benefits:
• easy installation 2
TM022304
SQFlex Solar
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
6 Solar panels
7 Support structure
12 IO 50 SQFlex switch box
11
3 SQFlex
14
switch 15
Benefits
5
Combined with CU 200, the level switch has a pump cut- 6
out function when the water reservoir is full.
CU 200 indicates the following:
• full water reservoir (level switch activated) 2
• pump operation 3
• input power. 4
5
CU 200 indicates operational downtime in the following
1
cases:
• dry running
• service (see CU 200 SQFlex control unit)
• insufficient energy supply.
Other benefits:
TM022305
• easy installation
• maintenance confined to periodic cleaning of the solar
panels
• few and simple components. SQFlex Solar with CU 200 and level switch
12
SQFlex
3
Applications
During periods of limited solar energy, the SQFlex Solar 13
system provides reliable water supply.
The system is connected to an external backup generator
via the IO 101. 10
The system switches automatically to operation via 7 6
generator when the generator is started.
If the generator is stopped manually or runs out of fuel,
the IO 101 automatically changes back to operation via 5
solar energy.
Benefits
The system ensures water supply during the night or
during periods of insufficient solar energy. 2
Other benefits: 3
4
• easy installation
5
• maintenance confined to periodic cleaning of the solar 1
panels
• few and simple components
• flexibility.
Note: IO 101 works with SQFlex up to 1400 W. IO 101B
works with any SQFlex up to 2500 W.
TM022309
SQFlex Solar with backup generator
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
6 Solar panels
7 Support structure
10 Diesel or gasoline generator
13 IO 101 SQFlex switch box
13
3 SQFlex
13
backup generator
During periods of limited solar energy, the SQFlex Solar
system provides reliable water supply.
The water supply is ensured by a diesel or gasoline 10
generator connected to the system through the IO 101. 7 6
TM035497
SQFlex Solar with CU 200 and backup generator
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
6 Solar panels
7 Support structure
10 Diesel- or gasoline-driven generator
11 CU 200 SQFlex control unit
13 IO 101 SQFlex switch box
14 Water reservoir
15 Level switch
14
SQFlex
3
Applications
16
During periods of limited solar energy, the SQFlex Solar 6
system provides reliable water supply.
The water supply is ensured by backup batteries 17
connected to the system through the charge controller. 19
7
The system is connected as shown in the fig. below. .
12 kWatt
11
• Power is provided by the solar panels wired to 18
produce minimum 60 VDC and maximum 110 VDC.
• Power from the solar panels is fed into a 48 VDC
charge controller, which regulates the current fed to 5
the batteries.
4
• From the charge controller, power passes into the
3
battery bank, which consists of the number of
appropriately sized batteries wired in series to achieve 2
48 VDC (rated) output.
1
• Power is drawn from the battery bank and routed
through a CU 200. Option: An IO 50 or IO 101 can be
installed to enable disconnection of the DC voltage. If
an IO 101 is installed, it is possible to add a generator
to the system.
TM034232
• Power is run from CU 200 to the SQFlex pump.
Benefits
SQFlex Solar with backup batteries
The system ensures water supply during the night or
during periods of insufficient solar energy.
Pos. Description
Other benefits:
1 SQF pump
• easy installation
2 Submersible drop cable
• maintenance confined to periodic cleaning of the solar 3 Cable clips
panels 4 Straining wire
• few and simple components 5 Wire clamps
• flexibility. 6 Solar panels
Note: CU 200 works with SQFlex up to 1400 W. CIU 903 7 Support structure
works with any SQFlex up to 2500 W. 11 CU 200 SQFlex control unit
12 IO 101 SQFlex switch box (optional)
16 Charge controller
17 Batteries
18 Pressure switch
19 Pressure tank
15
3 SQFlex
SQFlex Wind
Applications
Benefits
The breaker box makes it possible to slow down or stop
the wind turbine in the following cases:
• There is no need for water supply.
• The system requires service.
2
3
4
5
1
TM022306
SQFlex Wind
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
8 Wind turbine
9 Breaker box
16
SQFlex
3
Applications
8
14
switch 15
Benefits 5
TM022308
system and slows down or stops the wind turbine in the
following cases:
• There is no need for water supply.
SQFlex Wind with CU 200 and level switch
• The system requires service.
Note: CU 200 works with SQFlex up to 1400 W. CIU 903 Pos. Description
works with any SQFlex up to 2500 W.
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
8 Wind turbine
9 Breaker box
11 CU 200 SQFlex control unit
14 Water reservoir
15 Level switch
Related information
CU 200 SQFlex control unit
17
3 SQFlex
SQFlex Combi
Applications
Benefits 5
The system offers water supply during the night or during
periods of insufficient solar energy.
The breaker box makes it possible to switch off the power
supply in the system and to slow down or stop the wind
2
turbine in the following cases:
3
• There is no need for water supply. 4
• The system requires service. 5
Other benefits: 1
• easy installation
• minimal maintenance
• few and simple components.
TM022307
SQFlex Combi - combination of solar and wind energy
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
6 Solar panels
7 Support structure
8 Wind turbine
9 Breaker box
18
SQFlex
3
Applications
14
switch 8 15
• pump operation 5
1
• input power.
CU 200 indicates operational downtime in the following
cases:
• dry running
• service (see CU 200 SQFlex control unit)
TM022310
• insufficient energy supply.
The breaker box switches off the power supply in the
system and slows down or stops the wind turbine in the SQFlex Combi with CU 200 and level switch
following cases:
• There is no need for water supply. Pos. Description
• The system requires service. 1 SQF pump
Note: CU 200 works with SQFlex up to 1400 W. CIU 903 2 Submersible drop cable
works with any SQFlex up to 2500 W. 3 Cable clips
4 Straining wire
5 Wire clamps
6 Solar panels
7 Support structure
8 Wind turbine
9 Breaker box
11 CU 200 SQFlex control unit
14 Water reservoir
15 Level switch
19
3 SQFlex
power supply
The SQFlex system is connected to a diesel or gasoline
generator.
Benefits
The system provides water supply 24 hours a day,
regardless of the weather.
Other benefits:
• easy installation
• minimal maintenance
• few and simple components.
10
2
3
4
5
1
TM022311
Pos. Description
1 SQF pump
2 Submersible drop cable
3 Cable clips
4 Straining wire
5 Wire clamps
10 Generator
20
SQFlex
4
System components
4. System components
SQF submersible pump • level switch (pos. 9).
The SQF pump is available as a complete unit only. The communication between CU 200 and the pump is
ensured through the power supply cable. This is called
The complete SQF pump consists of the following
mains-borne signaling (or power line
components:
communication), which does not require extra cables
• motor between CU 200 and the pump.
• 2.0 m (6 ft 7 in) cable with water-level electrode and Start, stop and reset the pump with the ON/OFF button
socket (pos. 1).
• cable guard. CU 200 ensures system monitoring and alarm indication.
The operation can be monitored through the following
indications:
TM022217
• water reservoir full (level switch) (pos. 2)
• pump running (pos. 3)
4 3 2 1
11
10
5
TM022325
6 7 8 9
TM022437
CU 200 elements
Wiring diagram 95 mm
263 mm (10.35 in) (3.75 in)
kWatt
to a level switch and is designed for SQFlex power range
up to 1400 W and maximum 8.4 A.
CU 200 incorporates cable entries for the following
connections:
TM078601
21
4 SQFlex
System components
+5 V
+10 V
+24 V
F1 = OVERVOLTAGE
F2 = OVERTEMP
F3 = NO CONTACT
F4 = OVERLOAD
+5 V
+10 V
+24 V
F1 = OVERVOLTAGE
F2 = OVERTEMP
F3 = NO CONTACT
F4 = OVERLOAD
CONTROL INDICATOR
MAX SPEED GND IN
LEVEL SWITCH
TM022515
Electrical connections, CU 200
22
SQFlex
4
System components
remote monitoring
CIU 903 is a combined monitoring, control and
communication unit designed to work directly with a
SQFlex pump. When combined with a CIM 280 GRM
module, it enables remote monitoring through Grundfos
Go. Moreover, CIU 903 can be connected to a start/stop
switch, a level switch or a pulsating water meter. .
CIU 903 is designed to work with all SQFlex up to
2500 W.
External stop
Level switch
The communication between CIU 903 and the pump is
Warning
ensured through the power supply cable. This is called
mains-borne signaling (or power line communication),
NO
NC
C
which does not require extra cables between CIU 903 and
the pump.
Start, stop and reset the pump with the start/stop switch.
1 2 3 4 5 6 7 8 9 10
CIU 903 ensures system monitoring and alarm indication.
The pump operation can be monitored through the
TM079822
following indications:
• water reservoir full (level switch) + -
• pump running. Electrical connections, CIU 903
CIU 903 indicates the following alarms:
• dry running
• service needed:
- no contact to the pump
- overvoltage
- overtemperature
- overload.
Note: CIU 903 replaces CU 200 in the installation.
24-240VAC 24-240VDC
81.4 mm (3.2 in) 108 mm (4.25 in) L N
L N
+ -
154 mm (6.1 in)
TM056100
TM079823
23
4 SQFlex
The IO 50 is designed specifically for solar-powered The IO 101 is designed for solar-powered SQFlex
SQFlex systems. systems.
The IO 50 enables manual starting and stopping of the The IO 101 enables the connection of a backup generator
pump in an SQFlex Solar system, and functions as a in case of insufficient solar energy. The switching between
connection box joining all necessary cables. solar power and generator must be made manually.
If the generator is stopped manually or runs out of fuel,
100 mm (4 in) 80 mm (3.25 in)
the IO 101 automatically changes back to solar.
The IO 101 functions as a box that connects all necessary
cables.
IO 101 SQFlex
ON
TM061035
115 mm (4.56 in)
Wiring diagram, IO 50
1
TM078654
2 3
4
Pos. Description
1 Generator
2 PE
3 Power
4 Pump
24
SQFlex
4
Charge controller
System components
263 mm (10.35 in) 110mm (4.33 in)
The charge controller is used when a battery backup
IO 101 B SQFlex
system is installed with an SQFlex pumping system.
These systems are typically used in applications where
TM083111
low-yielding wells.
The charge controller is an automatic battery charger, and
the only setting required is the battery-selection.
Dimensions, IO 101 B There are three battery types available:
• gel battery
• sealed battery
• flooded battery.
The charge controller enables manual disconnection of
the pump, the solar modules or both at the same time.
Wind turbine
PE PE 1 2 3 4 The wind turbine has a working voltage range of 30 to
DC+/DC- maximum 220 VAC, single- or three-phase.
From
Solar Panel To Pump
A breaker box and must be included in SQFlex Wind
systems.
Note: The breaker box must be ordered separately.
Generator
The generator can be either diesel- or gasoline-driven.
1 The generator must be running steadily before the pump
is started.
TM083112
2
3
4
Pos. Description
1 Generator
2 PE
3 Power
4 Pump
25
5 SQFlex
System sizing
5. System sizing
Sizing of an SQFlex system Solar panel wiring
Grundfos has an online tool for the sizing of SQFlex
Methods of solar panel wiring
systems.
Solar panels can be connected in the following methods:
See Grundfos Product Center. The sizing tool covers both
solar- and wind-powered systems. 1. series wiring
For sizing the proper SQFlex system, the following 2. parallel wiring
parameters are required:
3. series/parallel wiring.
• location of installation
• maximum head The Grundfos SQFlex pump is most efficient at 120 V and
above, up to a maximum of 300 V. To maximize pump
• quantity of water. performance, connect panels to obtain at least 120 V.
Regarding the size of a correct solar-powered SQFlex
Series wiring
system, there are six regions:
All solar panels have a negative (-) and a positive (+)
• North America terminal.
• South America When wiring panels in series, voltages add and amperage
• Australia and New Zealand stays the same.
To wire panels in series, connect the positive terminal of
• Asia and the Pacific
one panel to the negative terminal of the next one.
• Southern Africa
• Europe, Middle East and Northern Africa. 1 2 3 4
TM062377
Voltage effect on pump efficiency
The pump efficiency can vary depending on the input
voltage. This chart shows the dropoff in efficiency as the
voltage gets lower. For example, if you have two systems Solar panel wiring in series
with the exact same wattage rating, but System A is
running at 120V and System B is running at 35V, System Pos. Description
A will produce 20 % more water than System B. 1 Panel #1
120-300 V -0 % 4 Panel #4
90 V -5 %
Panel voltages add in series, so if the panels in fig. Solar
60 V -10 % panel wiring in series are rated at 70 V (GF100), then the
35 V -20 % total voltage is the following:
70 + 70 + 70 + 70 = 280 V
Panel amperage remains the same, so if each panel
produces 1.43 A, then the total current is 1.43 A.
Panel wattage always adds, so if each panel is rated at
100 W, the total wattage (Watts = Volts x Amps) output is
the following:
100 + 100 + 100 + 100 = 400 W
26
SQFlex
5
Parallel wiring Series/parallel circuits
System sizing
When wiring panels in parallel, results are the opposite of A series/parallel circuit is simply two or more series
series wiring: amperages add and voltage stays the same. circuits that are wired together in parallel.
To wire panels in parallel, connect the positive terminal of 1
each panel to the positive terminal of the other panels and
2 3
negative terminal of each panel to the negative terminal of
the other panels.
1 2 3 4
TM062379
TM062378
5 6
ΔP x q x Vmp2
L = [m]
Wp x 100 x 2 x ρ
27
6 SQFlex
Performance curves
6. Performance curves
SQF 0.6-2
Q
[m³/ h]
0.75 SQF 0.6-2
0.70
m
20 m
m
30 m
m
m
m
0m
m
0m
10
15
m
25
m
0.65
0m
50
40
60
70
90
80
10
11
12
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
TM022338
0.00
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 P1 [ W]
SQF 0.6-3
Q
[m³/ h]
0.75 SQF 0.6-3
0.70
0m
0m
0m
0m
0m
0m
0m
m
m
0m
0m
0m
0.65
0m
80
90
10
11
12
13
14
15
16
17
18
19
20
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
TM033926
0.00
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 P1 [ W]
28
SQFlex
6
SQF 1-30
Performance curves
Q
[m³/ h]
2.4
SQF 1-30
2.2
5m
2.0
10 m
1.8
15 m
1.6
20 m
1.4
1.2
1.0 30 m
0.8
0.6
40 m
0.4
0.2
TM068847
0.0
40 60 80 100 120 140 160 180 200 220 240 260 280 300 P1 [ W]
SQF 1-70
Q
[m³/ h]
SQF 1-70
4.5
4.0
20 m
3.5
30 m
3.0
40 m
2.5 50 m
2.0 60 m
1.5 70 m
1.0
0.5
TM078120
0.0
0 100 200 300 400 500 600 700 800 900 1000 P1 [ W]
29
6 SQFlex
SQF 1.2-2
Performance curves
Q
[m³/ h]
SQF 1.2-2
15 m
m
m
m
m
10
1.40
m
20
25
30
m
40
50
m
60
m
70
0m
80
0m
90
1.30
0m
10
11
12
1.20
1.10
1.00
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
TM022339
0.00
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 P1 [ W]
SQF 1.2-3
Q
[m³/ h]
SQF 1.2-3
m
1.40
m
m
90
0
11
m
0
13
m
0
1.30
15
m
17
m
19
1.20
0
m
21
0
23
1.10
0
25
1.00
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
TM044606
0.00
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 P1 [ W]
30
SQFlex
6
SQF 2.5-2
Performance curves
Q
[m³/ h]
SQF 2.5-2
m
m
3.00
5m
m
m
m
m
10
15
m
20
25
m
30
40
m
50
2.80
m
60
70
m
80
0m
0m
90
2.60
10
11
0m
2.40
12
2.20
2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
TM022340
0.00
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 P1 [ W]
SQF 3A-10
Q
[m³/ h]
5.50
SQF 3A-10
5.00 30 m
35 m
4.50 40 m
45 m
4.00 50 m
55 m
3.50 60 m
65 m
3.00 70 m
2.50
2.00
1.50
1.00
0.50
TM033927
0.00
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 P1 [ W]
31
6 SQFlex
SQF 3-20
Performance curves
TM079983
SQF 3-105
Q
[m³/ h]
SQF 3-105
5.0
4.5 60 m
80 m
4.0
100 m
3.5
120 m
3.0
2.5
140 m
2.0
160 m
1.5
1.0
0.5
TM078118
0.0
200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 P1 [ W]
32
SQFlex
6
SQF 5A-3
Performance curves
Q
[m³/ h]
SQF 5A-3
10
9 2m
5m
8
10 m
7
15 m
TM022341
0
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 P1 [ W]
SQF 5A-7
Q
[m³/ h]
SQF 5A-7
10
9 10 m
15 m
8 20 m
25 m
7
30 m
35 m
6
40 m
5
45 m
50 m
4
1
TM022342
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 P1 [ W]
33
6 SQFlex
SQF 5-70
Performance curves
Q
[m³/ h]
SQF 5-70
9
8 20 m
40 m
7
60 m
6
80 m
4 100 m
TM078117
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 P1 [ W]
SQF 7-4
Q
[m³/h]
14 SQF 7-4
13 5m
10 m
12
15 m
11
20 m
10
25 m
9
8
30 m
7
5
35 m
4
1
TM065654
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 P1 [W]
34
SQFlex
6
SQF 7-55
Performance curves
Q
[m³/ h]
11
SQF 7-55
20 m
10
9
40 m
60 m
7
4 80 m
TM078119
0
200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 P1 [ W]
SQF 9-3
Q
[m³/h]
19 SQF 9-3
18
17 5m
16
10 m
15
14 15 m
13
20 m
12
11
10 25 m
9
8
7
6
5
4
3
2
1
TM065655
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 P1 [W]
35
6 SQFlex
SQF 14-3
Performance curves
Q
[m³/h]
26 SQF 14-3
24 5m
22
10 m
20
18
15 m
16
14
20 m
12
10
8
25 m
6
TM065656
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 P1 [W]
EuP ready
MEI index
Minimum Efficiency Index (MEI) means the dimensionless
scale unit for hydraulic pump efficiency at best efficiency
point (BEP), part load (PL) and overload (OL). Regulation
in EU sets efficiency requirements to MEI > 0.1 as of 1
January 2013, and MEI > 0.4 as of 1 January 2015. An
indicative benchmark for the best-performing water pumps
available on the market in 2012 is MEI ≥ 0.70.
36
SQFlex
7
Technical data
7. Technical data
Dimensions and weights
Dimensions [mm] Minimum borehole Net weight
Pump type
L B S [mm] * [kg] *
ø8 S
SQF 0.6-2 (N) 1185 74 RP 1 1/4 76 7.6
SQF 0.6-3 (N) 1235 74 RP 1 1/4 76 7.9
SQF 1-30 (N) 990 74 RP 1 1/4 76 5.1
SQF 1-70 (N) 861 74 RP 1 1/4 76 5.1
SQF 1.2-2 (N) 1225 74 RP 1 1/4 76 7.9
SQF 1.2-3 (N) 1295 74 RP 1 1/4 76 8.2
SQF 2.5-2 (N) 1247 74 RP 1 1/4 76 8.2
SQF 3A-10 (N) 968/1012 101 RP 1 1/4 104 9.5/11.1
L
Electrical data
Maximum power
DC Voltage AC Voltage Speed Maximum current
Pump type Motor type input
[VDC] [VAC] [RPM] [A]
P1 [W]
SQF 0.6-2 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 0.6-3 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 1-30 (N) MSF 3 (N) 30-300 90-240 10700 300 8.4
SQF 1-70 (N) MSF 3 (N) 30-300 90-240 10700 1000 8.4
SQF 1.2-2 (N) MSF 3 (N) 30-300 90-240 3600 1400 8,4
SQF 1.2-3 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 2.5-2 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 3A-10 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 3-20 (N) MSF 3 (N) 30-300 90-240 10700 300 8.4
SQF 3-105 (N) MSF 3 (N) 100-300 90-240 10700 2500 12
SQF 5A-3 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 5A-7 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 5-70 (N) MSF 3 (N) 100-300 90-240 10700 2500 12
SQF 7-4 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 7-55 (N) MSF 3 (N) 100-300 90-240 10700 2500 12
SQF 9-3 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
SQF 14-3 (N) MSF 3 (N) 30-300 90-240 3600 1400 8.4
37
7 SQFlex
SQF pump
Technical data
38
SQFlex
7
Technical data
Electrical data
Supply voltage 24-240 VAC/VDC - 10 %/+ 15 %
Transient overvoltage Category II
Frequency 0-60 Hz
Power consumption Maximum 11 W
IEC: 0.2 - 4 mm2
Cable size
UL: 24-12 AWG
Screened, double twisted-pair
Cross-section: 0.25 - 1 mm2
Recommended cable type
AWG: 24-18
Maximum cable length: 1200 m/4000 ft
Maximum length between the CIU 903 and the pump: 300 m (1000 ft)
Pump cable
Maximum length between the CIU 903 and the level switch: 500 m (1500 ft)
Cable entry 6 x M16 ∅4-10
GENIbus connection
Transceiver RS-485
Protocol GENIbus
Transmission speed 9600 bit/s
Environmental conditions
Altitude above sea level Maximum 2000 m (6500 ft)
Relative air humidity Maximum 100 %
External pollution degree Category 3
IP54 according to IEC 60529
Enclosure class
Type 3R according to UL 50
Ambient temperature
• During operation
- CIU XXX • -20 °C to +45 °C (-4 °F to +113 °F)
- CIU 250-299. • 0 °C to +40 °C (32 °F to 104 °F) (when battery is installed)
• During storage • -20 °C to +60 °C (-4 °F to +140 °F)
- CIU XXX • -20 °C to +35 °C (-4 °F to +95 °F) (when battery is installed)
- CIU 250-299. • -20 °C to +60 °C (-4 °F to +140 °F)
• During transportation • -20 °C to +35 °C (-4 °F to +95 °F) (when battery is installed)
- CIU XXX
- CIU 250-299.
39
7 SQFlex
40
SQFlex
7
Technical data
SQF SQF-N
Pos. Component Material
EN/DIN AISI EN/DIN AISI
1 Valve casing Polyamide
Stainless
1a Outlet chamber 1.4301 304 1.4401 316
steel
1d O-ring NBR
2 Valve cup Polyamide
Silicone
3 Valve seat
(LSR)
Stainless
6 Flange, upper 1.4401 316 1.4401 316
steel
Stainless
7a Retaining ring 1.4301 304 1.4401 316
spring steel
Stainless
9 Pump stator 1.4301 304 1.4401 316
steel/EPDM
Stainless
13 Pump rotor 1.4401 316 1.4401 316
steel
Stainless
16 Torsion shaft 1.4401 316 1.4401 316
steel
Stainless
39 Valve spring 1.4310 310 1.4401 316
spring steel
Stainless
55 Sleeve 1.4301 304 1.4401 316
steel
70 Valve guide Polyamide
159c Sand slinger NBR
Stainless
Cable guard 1.4301 304 1.4401 316
steel
Screws for Stainless
1.4401 316 1.4401 316
cable guard steel
TM022213
41
7 SQFlex
SQF SQF-N
Pos. Component Material
EN/DIN AISI EN/DIN AISI 1a
1 Valve casing Polyamide
Stainless
1a Outlet chamber 1.4301 304 1.4401 316
steel
70
14
1d O-ring NBR rubber
39 14a
2 Valve cup Polyamide
2
3 Valve seat NBR rubber
4a Empty chamber Polyamide 3
6 Top bearing NBR rubber
1 55
7 Neck ring TPU/PBT
18a
Stainless
7a Lock ring 1.4310 310 1.4404 316 1d
spring steel
Neck ring 7a
7b Polyamide
retainer
9b Chamber top Polyamide 6
64
Chamber 18
9c Polyamide
bottom 4a
30
Impeller with
87
13 tungsten carbide Polyamide
9b 86
bearing
Inlet
14 Polyamide 32
interconnector
Stainless 13
14a Ring 1.4301 304 1.4401 316 16
steel
Stainless 9c
1.4301 304 1.4401 316
Shaft with steel
16
coupling Sintered 7
steel
7b
Stainless
18 Cable guard 1.4301 304 1.4401 316
steel
Screws for cable Stainless
18a 1.4401 316 1.4401 316
guard steel
Cone for
30 pressure Polyamide
equalisation 222a
32 Guide vanes Polyamide
Stainless 225
39 Spring 1.4406 316LN 1.4406 316LN
spring steel
Stainless
55 Pump sleeve 1.4301 304 1.4401 316
steel
64 Priming screw Polyamide
70 Valve guide Polyamide
86 Lip seal ring NBR rubber
Cone for 201
pressure Polyamide /
87
equalisation NBR rubber
complete
TM012745
220
42
SQFlex
7
Technical data
Standard N-version
Pos. Component Material
EN
1 Valve casing Stainless steel 1.4301 1.4401
2 Valve cup Stainless steel 1.4301 1.4401
3 Valve seat Rubber type NBR NBR-FKM
7 Neck ring NBR/TPU
8 Bearing NBR
Carbon/graphite
Washer for stop
HY22 in PTFE
ring
mass
9 Chamber Stainless steel 1.4301 1.4401
12 Impeller Stainless steel 1.4301 1.4401
Inlet
14 Cast stainless steel 1.4308 1.4408
interconnector
Strainer Stainless steel 1.4301 1.4401
16 Shaft complete Stainless steel 1.4057 1.4460
17 Strap Stainless steel 1.4301 1.4401
18 Cable guard Stainless steel 1.4301 1.4401
TM061193
43
7 SQFlex
Standard N-version
Pos. Component Material
EN
1 Valve casing Cast stainless steel 1.4301 1.4401
2 Valve cup Cast stainless steel 1.4301 1.4401
3 Valve seat NBR-FKM NBR-FKM NBR-FKM
TPU/PPS- TPU/PPS-
7 Neck ring TPU/PPS-FKM
FKM FKM
8 Bearing LSR/FKM LSR/FKM LSR/FKM
Washer for stop Carbon/graphite
8a
ring HY22 in PTFE mass
9 Chamber Stainless steel 1.4301 1.4401
13 Impeller Stainless steel 1.4301 1.4401
Inlet
14 Cast stainless steel 1.4308 1.4408
interconnector
15 Strainer Stainless steel 1.4301 1.4401
16 Shaft complete Stainless steel 1.4057 1.4460
17 Strap Stainless steel 1.4301 1.4401
18 Cable guard Stainless steel 1.4301 1.4401
TM061110
Example SQF 9
44
SQFlex
7
Technical data
MSF 3, 500-3600 RPM
MSF 3 MSF 3 N
Pos. Component Material
EN/DIN AISI EN/DIN AISI
Stator with
201 sleeve, Stainless steel 1.4301 304 1.4401 316
complete
202 Rotor Stainless steel 1.4301 304 1.4401 316
202a Stop ring PP
202c Shaft end Stainless steel 1.4401 316 1.4401 316
Thrust bearing, Stainless
203 1.4401 316 1.4401 316
stationary steel/carbon
Bearing plate
205 with radial Silicon carbide 1.4301 304 1.4401 316
bearing
Stainless
Thrust bearing, steel/
206 1.4401 316 1.4401 316
rotating aluminium
oxide Al2O3
Motor cable with
220
plug
222a Filling plug Silicone (LSR)
223 Electronic unit
224 O-ring NBR
225 Top cover PPS
232 Shaft seal NBR
Thrust-bearing
243 Stainless steel 1.4408 316 1.4408 316
housing
Four screws
Stainless steel 1.4401 316 1.4401 316
(M4)
TM022215
45
7 SQFlex
223
220
250
TM011953
46
SQFlex
8
Product numbers
8. Product numbers
SQF submersible pump CU 200 SQFlex control unit
Product Product number
TM022217
CU 200 SQFlex 96625360
CU 200 SQFlex without angle plate 98147203
SQF 9-3 (N) 4" 98978826 98994640 IO 101 SQFlex, 115 V 96481502
47
9 SQFlex
Accessories
9. Accessories
Solar cables Submersible drop cable
The submersible drop cables for SQF pumps are
Length Product
Description Version
[m] number approved for use with potable water (KTW-approved). The
cables are made of EPR (ethylene-propylene rubber).
DC cable (12 AWG/3, Array to
10 98257868
3 mm2), UL-approved, controller (MC4)
for outdoor use with Array to array
MC4 0.5 98257892
(MC4)
TM007882
Level switch
TM022407
Nominal
diameter Product
Description Version
number
[mm]
Product 3G 1.5 mm2
Description 9.6 - 12.5 ID7946
number (round)
Level switch 3G 2.5 mm2
11.5 - 14.5 ID7947
High water level: Contact is closed. 16650 (round)
Low water level: Contact is open. 3-core cable including 2
earth conductor (KTW- 3G 4.0 mm 13.0 - 16.0 ID7948
1) (round)
approved)
Pressure switch 3G 6.0 mm2
14.5 - 20.0 RM4098
(round)
3G x 1.5 mm2
6.5 - 13.2 RM3952
(flat)
Product
Description
number
Pressure switch ID8952
d
impregnate
ing tissue ethane
Clean trichloro d or
inhale
with 1,1,1 when
hazard
(health
wed)
swallo
getrankt
ungstuch en
Reinig Trichlorethan h beim Einatm
mit 1,1,1 tsschadelic
(gesundhelhlucken)
oder Versc
neret
viet impr{g
Renseser trichlorethan
eller
med 1,1,1 ind}nding
ved
(farlig
else)
indtag
-3
A 207
EPP
TM003838
Cross-section
of conductors Product
Description
number
[mm2]
The kit is for watertight shrink-joining of
motor cable and submersible drop
cable (round or flat cable).
Enables the joining of
• cables of equal size
• cables of different size 1.5 - 6.0 96021473
• cable with single leads.
The joint is ready for use after a few
minutes and requires no long hardening
time as do resin joints.
The joint cannot be separated.
48
SQFlex
9
Accessories
TM077621
TM004179
Product
Description
number
Sacrificial anodes are placed on the outside of the pump
Dimensions Product and motor as a protection against corrosion.
Description
[m] number The zinc anode kit consists of 2 zinc anodes and a set
The clips are for fastening of cable and of fasteners. 92836041
straining wire to the riser pipe. Dimensions:
The clips should be fitted every 3 Length: 7.5 Diameter when fitted: 125 mm (4.9 in).
115016
metres. 16 buttons Minimum borehole diameter: 127 mm (5 in).
One set is enough for approximately.
45 m riser pipe.
Straining wire
TM007897
Diameter Product
Description
[mm] number
TM077637
The wire is stainless steel EN 1.4401.
2 ID8957
It retains the submersible pump.1)
motor.
The product number includes 1 zinc anode and 4
threaded rods. 99599098
Dimensions:
Product
Description Material The zinc anode adds 55 mm (2.2 in) to the length of the
number
pump.
Stainless steel Minimum borehole diameter: 76 mm (3 in).
Two clamps per loop ID8960
EN 1.4401
Grease
Description Product number
Grease for lubrication of motor shaft 96037562
49
9 SQFlex
Flow sleeves
Accessories
TM055814
Product
Description Material
number
Flow sleeve including
strainer and supporting Stainless steel EN 1.4301 98253259
bracket
Flow sleeve Stainless steel EN 1.4301 98253254
Strainer Stainless steel EN 1.4301 97943446
Supporting brackets Stainless steel EN 1.4301 97512995
TM013292
max. ø100
210 50 550 50
250
Product
Description Material
number
Flow sleeve including
strainer and supporting Stainless steel EN 1.4301 98148594
bracket
Flow sleeve Stainless steel EN 1.4301 97535677
Strainer Stainless steel EN 1.4301 97943446
Supporting brackets Stainless steel EN 1.4301 97512995
Product
Description Material
number
Flow sleeve including
strainer and supporting Stainless steel EN 1.4301 98255476
bracket
Flow sleeve Stainless steel EN 1.4301 98255472
Strainer Stainless steel EN 1.4301 97943446
Supporting brackets Stainless steel EN 1.4301 97512995
50
SQFlex
10
When you select your country, you will see the menus below. Note that some menus may not be available depending on
the country.
Example: https://product-selection.grundfos.com/uk
Pos. Description
1 Products & services enables you to find products and documents by typing a product number or name into the search field.
2 Applications enables you to choose an application to see how Grundfos can help you design and optimise your system.
3 Products A-Z enables you to look through a list of all the Grundfos products.
4 Categories enables you to look for a product category.
5 Liquids enables you to find pumps designed for aggressive, flammable or other special liquids.
6 Product replacement enables you to find a suitable replacement.
7 WWW enables you to select the country, which changes the language, the available product range and the structure of the website.
8 Sizing enables you to size a product based on your application and operating conditions.
51
96477803
ECM: 1351326
www.grundfos.com
Tel: +45 87 50 14 00
DK-8850 Bjerringbro
12.2022