The document outlines technical specifications for power transformers, including standards, service conditions, and key parameters. It specifies standards like IS 2026 and IS 1180 for power and distribution transformers. Parameters include type (dry/oil), rating, frequency, voltage, short circuit rating, impedance, winding configuration, tap changers, creepage distance, terminations, mounting, cooling, and monitoring requirements. Minimum requirements are defined for ratings, construction, insulation level, tapping methods, clearances, and general points based on transformer capacity.

Uploaded by

raj sekhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views3 pages

Transformer Specification

The document outlines technical specifications for power transformers, including standards, service conditions, and key parameters. It specifies standards like IS 2026 and IS 1180 for power and distribution transformers. Parameters include type (dry/oil), rating, frequency, voltage, short circuit rating, impedance, winding configuration, tap changers, creepage distance, terminations, mounting, cooling, and monitoring requirements. Minimum requirements are defined for ratings, construction, insulation level, tapping methods, clearances, and general points based on transformer capacity.

Uploaded by

raj sekhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Standards

IS 2026 (Specification of Power Transformer)


1 Standards IS 1180 (Specification outdoor type oil immersed distribution transformer)
IEC 60076
Service Conditions
2 Location Outdoor/ Indoor
3 Ambient Temperature
4 Altitude
Project Specific
5 Seismic Zone
6 Wind
Technical Parameters
7 Type Dry Type / Oil type

8 Rating of transformer (kVA)


9 Frequency (Hz) 50/ 60Hz

10 Voltage Rating (HV/LV)


11 Short Circuit (kA) for 1sec
12 Impedance (%Z)
13 Winding Connection & Material
14 Tap Changer (OCTC/OLTC)
15 Minimum Creepage (mm/Kv)
HV side Termination
16
(Cable Box/ Bushings/ Busduct)

LV side Termination
17
(Cable Box/ Bushings/ Busduct)

18 Marshalling Box

19 Mounting Arrangement of Transformer

20 Cooling Cabinet 2x50%

21 Online conditional monitoring DGA, PD etc


Mimimum Parameter to be checked as per IS1180

1 Ratings

<200kVA (Refer Table - 3)


>200kVA and <2500kVA (Refer Table - 6)

3 Contruction

4 Basic Insulation Level

5 Winding Connection Dyn11

5 Tapping Methods & Range

6 Minumum Air Clearance


7 General Points