Applications
Line protection
Station protection
Base stations
Electrical specifications
DC spark-over voltage 1) 2) 4) 350 V
± 20 %
Impulse spark-over voltage4)
at 100 V/μs - typical values of distribution < 700 V
at 1 kV/μs - typical values of distribution < 800 V
Service life 3)
5 operations 50 Hz, 1 s 10 A
10 operations 8/20 μs 10 kA
Insulation resistance at 100 VDC4) >1 GΩ
4)
Capacitance at 1 MHz < 1.5 pF
Transverse delay time < 0.2 μs
Arc voltage at 1 A ~ 35 V
Glow to arc transition current ~1 A
Glow voltage ~ 200 V
Weight ~ 2.2 g
Operation and storage temperature -40 ~ +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, blue negative
1/2
Gas Discharge Tubes GDTR3RD7-350
Dimensional drawing
15.5 ±0.5
Ø1.0
4.4±0.3 4.4±0.3 Dimensions in mm
GDT R 3R D7-350
DC Spark-over Voltage of 350V (at 100V/s)
Diameter: Ø7.5×T11.5
3 Electrodes
Lead Configuration
R=Radial Leads
Gas Discharge Tubes
Package Information
Quantity:100PCS(Plastic box),5000PCS(Carton)
Measurement: 197×167×9mm(Plastic box),360×260×210mm(Carton)
Effectivity: Reference documents shall be the issue in effect on the date of invitation for bid.
Caution: Operation beyond the rated voltage or current may result in rupture electrical arcing or flame.