FusionServer 2288H V6 Server Technical White Paper PDF
FusionServer 2288H V6 Server Technical White Paper PDF
FusionServer 2288H V6 Server Technical White Paper PDF
Issue 07
Date 2022-11-11
Notice
In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise
description and easy understanding, which does not mean that "xFusion" may have any other meaning.
Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion
Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd. shall not bear any liability resulting
from the use of "xFusion".
The purchased products, services and features are stipulated by the contract made between xFusion and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
2022-11-11 ii
FusionServer 2288H V6 Server
Technical White Paper Contents
Contents
2022-11-11 iii
FusionServer 2288H V6 Server
Technical White Paper Contents
2022-11-11 iv
FusionServer 2288H V6 Server
Technical White Paper Contents
2022-11-11 v
FusionServer 2288H V6 Server
Technical White Paper Contents
2022-11-11 vi
FusionServer 2288H V6 Server
Technical White Paper About This Document
Purpose
This document describes the FusionServer 2288H V6 rack server in terms of features,
structure, specifications, and component hardware and software compatibility.
Intended Audience
This document is intended for pre-sales engineers.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
2022-11-11 vii
FusionServer 2288H V6 Server
Technical White Paper About This Document
Change History
Issue Release Date Change Description
2022-11-11 viii
FusionServer 2288H V6 Server
Technical White Paper 1 Overview
1 Overview
For details about the 2288H V6 nameplate information, see A.4 Nameplate.
2022-11-11 9
FusionServer 2288H V6 Server
Technical White Paper 1 Overview
2022-11-11 10
FusionServer 2288H V6 Server
Technical White Paper 2 Features
2 Features
2022-11-11 11
FusionServer 2288H V6 Server
Technical White Paper 2 Features
⚫ 2288H V6-16DIMM servers support a maximum of 16 DDR4 ECC 3200 MT/s DIMMs.
The DDR4 ECC DIMMs support registered DIMMs (RDIMM) and load-reduced
DIMMs (LRDIMMs), which provide high speed and availability. A server supports a
maximum memory capacity of 2048 GB and a maximum memory bandwidth of 400
GB/s in theory.
⚫ Flexible drive configurations meet a variety of business requirements and ensure high
elasticity and scalability of storage resources.
⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times
more I/O operations per second (IOPS) than a typical hard disk drive (HDD). The use of
all SSDs provides higher I/O performance than the use of all HDDs or a combination of
HDDs and SSDs.
⚫ The use of 12 Gbit/s SCSI (SAS) serial connection for internal storage provides 2x data
transmission rate than the use of 6 Gbit/s SAS connection, maximizing the performance
of I/O-intensive applications.
⚫ With Intel integrated I/O, the third-generation Intel® Xeon® Scalable processors integrate
the PCIe 4.0 controller to shorten I/O latency and improve overall system performance.
⚫ 2288H V6-32DIMM supports a maximum of eleven standard PCIe 4.0 expansion slots.
2288H V6-16DIMM supports a maximum of two standard PCIe 4.0 expansion slots and
five standard PCIe 3.0 expansion slots.
⚫ 2288H V6-32DIMM supports two FlexIO cards (adapting to the OCP 3.0 network
adapter). 2288H V6-16DIMM supports one FlexIO card (adapting to the OCP 3.0
network adapter) with flexible configuration of GE/10GE/25GE/100GE network
adapters which are hot swappable.
2022-11-11 12
FusionServer 2288H V6 Server
Technical White Paper 2 Features
⚫ The NC-SI feature allows a network port to serve as a management port and a service
port. The NC-SI feature is disabled by default and can be enabled through the iBMC or
BIOS.
⚫ The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault handling.
⚫ The server chassis panel ensures security of local data.
⚫ Chassis cover opening detection is supported to enhance security.
⚫ Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer
overflow attacks when working with a supported OS.
⚫ The Intel Converged Boot Guard & Trusted Execution Technology (Intel CBnT)
prevents malicious software attacks based on hardware, prevents the firmware from
being maliciously modified, and prevents the execution of unauthorized boot blocks. It
also allows applications to run in their own independent space without being affected by
other software running in the system, thereby enhancing security.
⚫ The secure boot based on the chip RoT implements level-by-level firmware verification
starting from the hardware RoT and builds a complete secure boot chain.
⚫ The trusted platform module (TPM) and trusted cryptography module (TCM) provide
advanced encryption functions, such as digital signatures and remote authentication.
⚫ The following requirements in NIST SP 800-147B are met:
− The BIOS firmware digital signature update mechanism is supported. During the
upgrade, the digital signature is verified to prevent unauthorized BIOS firmware
upgrade.
− The flash security protection mechanism is supported to prevent unauthorized
modification of the flash memory in the OS.
The service port with NC-SI enabled supports the following configuration:
⚫ Configuring any network port on the FlexIO card or PCIe NIC (with NC-SI enabled).
⚫ Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port. The VLAN ID
is 0 and disabled by default.
⚫ Configuring IPv4 addresses (IPv4 address, subnet mask, and gateway) and IPv6 addresses (IPv6
address, prefix length, and gateway) for this port.
Energy Efficiency
⚫ The server supports 80 Plus Platinum/Titanium PSUs of different energy efficiency
levels. The PSU efficiency reaches 96% at 50% load.
⚫ Active/standby power supply and HVDC power supply are supported, improving the
efficiency of the power supply system.
⚫ Efficient voltage regulator-down (VRD) power supplies for boards minimize the energy
loss from DC/DC power conversion.
⚫ Area-based, Proportional-Integral-Derivative (PID) intelligent fan speed adjustment and
intelligent CPU frequency scaling optimize heat dissipation and reduce overall system
power consumption.
⚫ The improved thermal design with energy-efficient fans ensures optimal heat dissipation
and reduces system power consumption.
⚫ The server is protected with power capping and power control measures.
⚫ Staggered spin-up of drives reduces the server boot power consumption.
2022-11-11 13
FusionServer 2288H V6 Server
Technical White Paper 3 Physical Structure
3 Physical Structure
2022-11-11 14
FusionServer 2288H V6 Server
Technical White Paper 3 Physical Structure
2022-11-11 15
FusionServer 2288H V6 Server
Technical White Paper 3 Physical Structure
3 PSU 4 Chassis
5 I/O module 3 6 Supercapacitor holder
7 Air duct 8 Intrusion sensor
NOTE
The air duct cannot be installed
on a server with built-in drives.
2022-11-11 16
FusionServer 2288H V6 Server
Technical White Paper 4 Logical Structure
4 Logical Structure
⚫ The server supports one or two third-generation Intel® Xeon® Scalable Ice Lake
processors.
⚫ The server supports up to 32 memory modules.
2022-11-11 17
FusionServer 2288H V6 Server
Technical White Paper 4 Logical Structure
⚫ The CPUs (processors) interconnect with each other through three UPI links at a speed
of up to 11.2 GT/s.
⚫ The PCIe riser card connects to the processors through PCIe buses to provide ease of
expandability and connection.
⚫ CPU1 and CPU2 each support one OCP 3.0 network adapter.
⚫ The screw-in RAID controller card on the mainboard connects to CPU 1 through PCIe
buses, and connects to the drive backplane through SAS signal cables. A variety of drive
backplanes are provided to support different local storage configurations.
⚫ The LBG-R Platform Controller Hub (PCH) is integrated on the mainboard to support
five USB 3.0 ports.
⚫ The BMC management chip integrated on the mainboard supports ports such as a video
graphic array (VGA) port, a management network port, and a serial port.
⚫ The server supports one or two third-generation Intel® Xeon® Scalable Ice Lake
processors.
⚫ The server supports up to 16 memory modules.
⚫ The CPUs (processors) interconnect with each other through three UPI links at a speed
of up to 11.2 GT/s.
⚫ CPU1 supports one OCP 3.0 network adapter.
2022-11-11 18
FusionServer 2288H V6 Server
Technical White Paper 4 Logical Structure
⚫ The screw-in RAID controller card on the mainboard connects to CPU 1 through PCIe
buses, and connects to the drive backplane through SAS signal cables. A variety of drive
backplanes are provided to support different local storage configurations.
⚫ The LBG-R Platform Controller Hub (PCH) is integrated on the mainboard to support
three USB 3.0 ports.
⚫ The BMC management chip integrated on the mainboard supports ports such as a video
graphic array (VGA) port, a management network port, and a serial port.
2022-11-11 19
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5 Hardware Description
2022-11-11 20
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 21
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 22
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 23
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 24
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 25
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 26
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.1.3 Ports
Port Positions
⚫ 8 x 2.5" drive configuration
2022-11-11 27
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
management port
3 VGA port - -
2022-11-11 28
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Port Description
2022-11-11 29
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Note: The VGA port and iBMC direct connect management port cannot be used at the
same time.
2022-11-11 30
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ I/O module 1 and I/O module 2 each support a PCIe riser module, 2 x 3.5" rear-drive module, or
module with 2 x 2.5" rear drives and one PCIe riser module.
⚫ I/O module 3 supports a PCIe riser module or 4 x 2.5" rear-drive module.
⚫ For details about the OCP 3.0 network adapter, see 5.1.6.1 OCP 3.0 Network Adapters .
⚫ The figure is for reference only. The actual configuration may vary.
⚫ Server with four GPUs on the rear panel
2022-11-11 31
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
1 Slot2 2 Slot3
3 Slot6 4 Slot7
5 PSU 2 6 Power supply unit (PSU) 1
7 (Optional) FlexIO card 2 8 (Optional) Slot 9
NOTE
The FlexIO card slot supports
only OCP 3.0 network adapters.
⚫ For details about the OCP 3.0 network adapter, see 5.1.6.1 OCP 3.0 Network Adapters .
⚫ The figure is for reference only. The actual configuration may vary.
⚫ Server with 11 Standard PCIe Cards on the Rear Panel
1 Slot1 2 Slot2
3 Slot3 4 Slot4
5 Slot5 6 Slot6
2022-11-11 32
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
7 Slot7 8 Slot8
9 Slot9 10 Slot10
11 Slot11 12 Power supply 2
13 Power supply unit (PSU) 1 14 (Optional) FlexIO card 2
NOTE
The FlexIO card slot supports
only OCP 3.0 network adapters.
⚫ For details about the OCP 3.0 network adapter, see 5.1.6.1 OCP 3.0 Network Adapters .
⚫ The figure is for reference only. The actual configuration may vary.
Indicator Positions
⚫ Server with a drive module or PRM on the rear panel
5 PSU indicator - -
2022-11-11 33
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5 PSU indicator - -
5 PSU indicator - -
2022-11-11 34
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Indicator Description
2022-11-11 35
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.2.3 Interface
Port Positions
⚫ Server with a drive module or PRM on the rear panel
2022-11-11 36
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Port Description
2022-11-11 37
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.3 Processors
⚫ The server supports one or two processors.
⚫ If only one processor is required, install it in socket CPU1.
⚫ Processors of the same model must be used in a server.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility
Checker to determine the components to be used.
2022-11-11 38
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.4 Memory
5.1.4.1 DDR4 Memory
5.1.4.1.1 Memory ID
You can determine the memory module properties based on the label attached to the memory
module.
2022-11-11 39
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
1 Capacity ⚫ 16 GB
⚫ 32 GB
⚫ 64 GB
⚫ 128 GB
⚫ 256 GB
2 Number of ranks ⚫ 1R: single-rank
⚫ 2R: dual-rank
⚫ 4R: quad-rank
⚫ 8R: octal-rank
3 Data width on the DRAM ⚫ x4: 4-bit
⚫ x8: 8-bit
4 Type of the memory interface ⚫ PC4: DDR4
5 Maximum memory speed ⚫ 2933 MT/s
⚫ 3200 MT/s
6 Memory latency parameters ⚫ W = 20-20-20
(CL-tRCD-tRP) ⚫ Y = 21-21-21
⚫ AA = 22-22-22
7 DIMM type ⚫ R = RDIMM
⚫ L = LRDIMM
2022-11-11 40
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
D DIMM031(L)
E (primary) DIMM040(E)
E DIMM041(M)
F (primary) DIMM050(F)
F DIMM051(N)
G (primary) DIMM060(G)
G DIMM061(O)
H (primary) DIMM070(H)
H DIMM071(P)
CPU2 A (primary) DIMM100(A)
A DIMM101(I)
B (primary) DIMM110(B)
B DIMM111(J)
C (primary) DIMM120(C)
C DIMM121(K)
D (primary) DIMM130(D)
D DIMM131(L)
E (primary) DIMM140(E)
E DIMM141(M)
F (primary) DIMM150(F)
F DIMM151(N)
G (primary) DIMM160(G)
G DIMM161(O)
H (primary) DIMM170(H)
H DIMM171(P)
2022-11-11 41
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ A server must use DDR4 memory modules of the same part number (P/N code), and the
memory speed is the minimum value of the following items:
⚫ Memory speed supported by a CPU
⚫ Maximum operating speed of a memory module
⚫ The DDR4 DIMMs of different types (RDIMM and LRDIMM) and specifications
(capacity, bit width, rank, and height) cannot be used together.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker
to determine the components to be used.
⚫ The memory can be used with the third-generation Intel® Xeon® Scalable Ice Lake
processors. The maximum memory capacity supported by all processor models is the
same.
⚫ The total memory capacity is the sum of the capacity of all DDR4 DIMMs.
The total memory capacity refers to the capacity when DDR4 memory modules are fully
configured. For details about the memory capacity when PMem modules are used together
with DDR4 memory modules, see 5.1.4.2.3 Memory Compatibility.
⚫ For details about the capacity type of a single memory module, see "Search Parts" in the
Compatibility Checker.
⚫ The maximum number of memory modules supported depends on the memory type and
rank quantity.
Each memory channel supports a maximum of 8 ranks. The number of memory modules supported by
each channel varies depending on the number of ranks supported by each channel:
Number of memory modules supported by each channel ≤ Number of ranks supported by each memory
channel/Number of ranks supported by each memory module
⚫ A memory channel supports more than eight ranks for LRDIMMs.
A quad-rank LRDIMM generates the same electrical load as a single-rank RDIMM on a memory bus.
Parameter Specifications
2022-11-11 42
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Parameter Specifications
servera
Maximum DDR4 512 1024 2048 4096 8192
memory capacity of the
server (GB)
Actual 1DPCb 3200 3200 3200 3200 2933
rate
(MT/s) 2DPC 3200 3200 3200 3200 2933
This section applies to a server fully configured with DDR4 memory modules. If PMem modules are
used together, see 5.1.4.2.4 DIMM Installation Rules.
2022-11-11 43
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
At least one DDR4 memory module must be installed in the primary memory channels
corresponding to CPU 1.
2022-11-11 44
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 45
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 46
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.4.2 PMem
5.1.4.2.1 Memory Identifier
2022-11-11 47
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2 SN 8089-A2-2008-00002461
3 Model NMB1XXD512GPSU4
4 Capacity (GB) ⚫ 128
⚫ 256
⚫ 512
5 SN QR code 8089-A2-2008-00002461
2022-11-11 48
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
B (primary) DIMM110(B)
B DIMM111(J)
C (primary) DIMM120(C)
C DIMM121(K)
D (primary) DIMM130(D)
D DIMM131(L)
E (primary) DIMM140(E)
E DIMM141(M)
F (primary) DIMM150(F)
F DIMM151(N)
G (primary) DIMM160(G)
G DIMM161(O)
H (primary) DIMM170(H)
H DIMM171(P)
⚫ The PMem modules must be used with the DDR4 memory modules. For details, see
FusionServer PMem 200 User Guide.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker
to determine the components to be used.
⚫ The memory must be used with the third-generation Intel® Xeon® Scalable Ice Lake
processors. The maximum memory capacity supported by all processor models is the
same.
⚫ The PMem module can work only in App Direct Mode (AD) and Memory Mode (MM).
The total supported memory capacity is calculated as follows:
− PMem module in AD mode
Total memory capacity = Total capacity of all PMem modules+ Total capacity of all
DDR4 memory modules
− PMem module in MM mode
Total memory capacity = Total capacity of all PMem modules (The DDR4 memory
modules are used as the cache and therefore are not calculated as memory capacity.)
2022-11-11 49
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
For details about the AD and MM modes, see FusionServer PMem 200 User Guide.
⚫ For details about the capacity type of a single memory module, see "Search Parts" in the
Compatibility Checker.
⚫ The maximum number of memory modules supported depends on the memory type and
rank quantity.
Each memory channel supports a maximum of 8 ranks. The number of memory modules supported by
each channel varies depending on the number of ranks supported by each channel:
Number of memory modules supported by each channel ≤ Number of ranks supported by each memory
channel/Number of ranks supported by each memory module
2022-11-11 50
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 51
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 52
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.5 Storage
5.1.5.1 Drive Configurations
5.1.5.1.1 8 x 2.5" Drive Pass-through Configuration
Drive configuration
2022-11-11 53
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 54
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 1 in Table 5-9
0 0
1 1
2 2
3 3
4 4
5 5
2022-11-11 55
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
6 6
7 7
44 44
45 45
46 46
47 47
⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 2 and 8 x 2.5" drive
pass-through configuration 3 in Table 5-9
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
44 44 -
2022-11-11 56
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
45 45 -
46 46 -
47 47 -
⚫ Drive slot numbers of 8 x 2.5" drive pass-through + 11 x PCIe card configuration 1, and
8 x 2.5" drive + 4 x GPU configuration 1 in Table 5-9
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
2022-11-11 57
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4Note
5 5 5Note
6 6 6Note
7 7 7Note
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
0 0 0
2022-11-11 58
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
Drive configuration
2022-11-11 59
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 60
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
2022-11-11 61
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 -
5 5 -
6 6 -
7 7 -
8 8 -
9 9 -
10 10 -
11 11 -
Drive configuration
2022-11-11 62
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 63
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 64
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 65
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 66
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
2022-11-11 67
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
8 8
9 9
10 10
11 11
44 44
45 45
46 46
47 47
Figure 5-44 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2)
Figure 5-45 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
2022-11-11 68
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 69
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-46 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
Figure 5-47 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
2022-11-11 70
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
10 10 10
11 11 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
47 47 -
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
2022-11-11 71
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
42 42 12
43 43 13
44 44 -
45 45 -
46 46 -
47 47 -
0 0 0
1 1 1
2 2 2
2022-11-11 72
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 0
41 41 1
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 73
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
42 42 0
43 43 1
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 74
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
44 44
45 45
46 46
47 47
Figure 5-52 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2)
2022-11-11 75
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-53 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8Note
9 9 9Note
10 10 10Note
11 11 11Note
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
2022-11-11 76
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
47 47 -
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
Figure 5-54 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
Figure 5-55 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
0 0 0
1 1 1
2022-11-11 77
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8Note
9 9 9Note
10 10 10Note
11 11 11Note
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
47 47 -
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
Drive configuration
2022-11-11 78
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 79
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 80
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 81
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 82
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-56 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2)
2022-11-11 83
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-57 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 84
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
36 36 8
37 37 9
38 38 10
39 39 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 12Note
45 45 13Note
46 46 14Note
47 47 15Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate drive slot numbers are displayed on a RAID controller card, you are advised
to locate the drive based on the EID.
2022-11-11 85
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-58 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
2022-11-11 86
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-59 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 87
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
36 36 8
37 37 9
38 38 10
39 39 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 12Note
45 45 13Note
46 46 14Note
47 47 15Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate drive slot numbers are displayed on a RAID controller card, you are advised
to locate the drive based on the EID.
Figure 5-60 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2)
2022-11-11 88
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-61 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
Figure 5-62 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
Figure 5-63 Drive slot numbers (3.5" drives in I/O module 1 and 2.5" drives in I/O module
2)
2022-11-11 89
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 90
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-64 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
Figure 5-65 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
2022-11-11 91
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
10 10 10
11 11 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
47 47 -
⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 5 (dual RAID controller cards)
in Table 5-28
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
2022-11-11 92
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 0
41 41 1
44 44 -
45 45 -
46 46 -
47 47 -
Figure 5-67 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
2022-11-11 93
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-68 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
42 42 14
43 43 15
44 44 -
45 45 -
46 46 -
2022-11-11 94
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
47 47 -
Drive configuration
2022-11-11 95
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
2022-11-11 96
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9
10 10
11 11
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
0 0 0
1 1 1
2 2 2
2022-11-11 97
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
3 3 3
4 4 -
5 5 -
6 6 -
7 7 -
8 8 -
9 9 -
10 10 -
11 11 -
16 16 -
17 17 -
18 18 -
19 19 -
20 20 -
21 21 -
22 22 -
23 23 -
44 44 4
45 45 5
46 46 6
47 47 7
Drive configuration
2022-11-11 98
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 99
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 100
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
2022-11-11 101
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
2022-11-11 102
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0Note
1 1 1Note
2 2 2Note
3 3 3Note
4 4 -
5 5 -
6 6 -
7 7 -
8 8 -
9 9 -
10 10 -
11 11 -
12 12 -
13 13 -
14 14 -
15 15 -
16 16 -
17 17 -
18 18 -
19 19 -
20 20 -
21 21 -
22 22 -
23 23 -
44 44 4
45 45 5
46 46 6
47 47 7
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
2022-11-11 103
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
2022-11-11 104
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
23 23
44 44
45 45
46 46
47 47
0 0 0Note
1 1 1Note
2 2 2Note
3 3 3Note
4 4 -
5 5 -
6 6 -
7 7 -
8 8 -
9 9 -
2022-11-11 105
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
10 10 -
11 11 -
12 12 -
13 13 -
14 14 -
15 15 -
16 16 -
17 17 -
18 18 -
19 19 -
20 20 -
21 21 -
22 22 -
23 23 -
44 44 4
45 45 5
46 46 6
47 47 7
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ Drive slot numbers of 24 x 2.5" drive pass-through configuration (three RAID controller
cards) in Table 5-38
2022-11-11 106
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 0
9 9 1
10 10 2
11 11 3
12 12 4
13 13 5
14 14 6
15 15 7
16 16 0
17 17 1
18 18 2
2022-11-11 107
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
19 19 3
20 20 4
21 21 5
22 22 6
23 23 7
44 44 -
45 45 -
46 46 -
47 47 -
Drive configuration
2022-11-11 108
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 109
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 110
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 111
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
2022-11-11 112
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 113
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
2022-11-11 114
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 115
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
2022-11-11 116
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 8Note
45 45 9Note
46 46 10Note
47 47 11Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate drive slot numbers are displayed on a RAID controller card, you are advised
to locate the drive based on the EID.
0 0 0
2022-11-11 117
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 8Note
45 45 9Note
46 46 10Note
47 47 11Note
2022-11-11 118
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 5 (dual RAID controller cards)
in Table 5-44
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
2022-11-11 119
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 0
41 41 1
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 120
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-83 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
Figure 5-84 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 121
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
42 42 27
43 43 28
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 122
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Figure 5-85 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2)
Figure 5-86 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module
2)
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 123
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
42 42 27
43 43 28
44 44 8Note
45 45 9Note
46 46 10Note
47 47 11Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate drive slot numbers are displayed on a RAID controller card, you are advised
to locate the drive based on the EID.
2022-11-11 124
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives
support surprise hot swap.
2022-11-11 125
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ If the VMD function is disabled, NVMe drives support only orderly hot swap.
2022-11-11 126
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.6 Network
5.1.6.1 OCP 3.0 Network Adapters
OCP 3.0 network adapters provide network expansion capabilities.
⚫ The FlexIO slot supports the OCP 3.0 network adapter, which can be configured as
required.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility
Checker to determine the components to be used.
2022-11-11 127
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ For details about the OCP 3.0 network adapter, see the documents of each OCP 3.0
network adapter.
PCIe Slots
⚫ Server with a drive module or PRM on the rear panel
− I/O module 1 provides slots 1, 2, and 3. If a two-slot PCIe riser module is used, slot
1 is unavailable. If a module with 2 x 2.5" drives and one PCIe card is used, slots 1
and 2 are unavailable.
− I/O module 2 provides slots 4, 5, and 6. If a two-slot PCIe riser module is used, slot
4 is unavailable. If a module with 2 x 2.5" drives and one PCIe card is used, slots 4
and 5 are unavailable.
− I/O module 3 provides slots 7 and 8. If a one-slot PCIe riser module is used, slot 7
is unavailable.
2022-11-11 128
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ I/O module 2 supports two HHHL PCIe x8 and one HHHL x16 GPU cards.
⚫ I/O module 3 supports two HHHL PCIe x8 GPU cards.
⚫ Server with four GPU cards on the rear panel
⚫ Select this model when three or four FHFL dual-slot x16 GPU cards are required.
⚫ GPU cards are installed in slots 2, 3, 6, and 7 in sequence.
⚫ Server with 11 standard PCIe cards on the rear panel
PCIe Riser Modules (Applicable to the Server with a Drive Module or PCIe Riser
Module on the Rear Panel)
⚫ PCIe riser module 1 (universal)
− Provides PCIe slots 1, 2, and 3 when installed in I/O module 1.
− Provides PCIe slots 4, 5, and 6 when installed in I/O module 2.
2022-11-11 129
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 130
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 131
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 132
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ PCIe riser module 7 (applicable to the 24 x 2.5" drive pass-through model 1/2)
Installed in I/O module 1 or 2.
2022-11-11 133
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 134
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 135
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
PCIe Riser Modules (Applicable to the Server with Four GPU Cards on the Rear
Panel)
⚫ PCIe riser module 1 or PCIe riser module 2
− PCIe riser module 1 provides slots 2 and 3.
− PCIe riser module 2 provides slots 6 and 7.
2022-11-11 136
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 137
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 138
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
PCIe Riser Modules (Applicable to the Server with 11 Standard PCIe cards on
the Rear Panel)
⚫ PCIe riser module 1
Provides PCIe slots 1, 2, 3, 4, 5, and 6 when installed in PCIe riser module 1.
2022-11-11 139
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 140
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Server with Drive Modules or PCIe Riser Modules on the Rear Panel
2022-11-11 141
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 142
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 143
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 144
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 145
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 146
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 147
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.8 PSUs
⚫ The server supports one or two PSUs.
⚫ The server supports AC or DC PSUs.
2022-11-11 148
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 149
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.10 LCD
Function
The LCD displays the installation status and running status of server components and enables
users to set the IP address of the iBMC management network port on the server.
The LCD and the server iBMC form an LCD subsystem. The LCD directly obtains device
information from the iBMC. The LCD subsystem does not store device data.
2022-11-11 150
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
UI
Tab Function
2022-11-11 151
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Tab Function
temperature of the server.
Info. Displays the IP address and MAC address of the iBMC
management network port, device SNs, asset information, and
firmware version.
Setting Sets the IP address of the iBMC management network port.
For details about how to use the LCD module, see FusionServer Rack Server LCD User
Guide.
2022-11-11 152
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.1.11 Boards
5.1.11.1 Mainboard
2022-11-11 153
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
(SLIMLINE7/J31) CONN/J109)
7 Built-in storage expansion 8 2 x USB 3.0 ports (USB3.0
port (SD CARD/J87) CONN/J88)
9 Rear VGA port (VGA 10 Serial port (COM/J6020)
CONN/J60)
11 BMC management network 12 BMC management board
port (BMC_GE /J6019)
13 LCD connector (LCD 14 OCP 3.0 network adapter 1
CONN/J6025) connector (OCP1
CONN/J108)
15 Rear-drive backplane power 16 NC-SI connector (NCSI
connector 2 (REAR BP CONN/J114)
PWR2/J21)
17 LP slimline 6 connector for 18 PCIe riser 1 slot (PCIE
OCP 3.0 network adapter 1 RISER1/J50)
(SLIMLINE6/J13)
19 TPM/TCM connector (J10) 20 mini-SAS HD connector C
(MINIHD PORTC/J4)
21 Drive backplane power 22 Built-in USB 3.0 connector
connector 3 (HDD BP (INNER USB3.0/J110)
PWR3/J89)
23 Right mounting ear connector 24 mini-SAS HD connector B
(RCIA BOARD/J113) (MINIHD PORTB/J5)
25 Rear-drive backplane power 26 mini-SAS HD connector A
connector 1 (REAR BP (MINIHD PORTA/J6)
PWR1/J64)
27 SATA connector 1 28 SATA connector 2
(SATA1/J1) (SATA2/J2)
29 Cell battery holder (U9) 30 VROC key connector (Soft
RAID KEY/J3)
31 LP slimline 1 connector 32 LP slimline 2 connector
(SLIMLNE1/J11) (SLIMLNE2/J84)
33 Fan module 4 connector 34 Fan module 4 connector (2U
(J100) FAN4/J98)
35 Fan module 3 connector (J97) 36 Fan module 3 connector (2U
FAN3/J95)
37 Intrusion sensor connector 38 Fan module 2 connector (J93)
(INTRUDER CONN/S1)
39 Low-speed signal connector 40 Fan module 2 connector (2U
for the front-drive backplane FAN2/J91)
(FRONT HDD BP/J75)
41 Fan module 1 connector 42 Fan module 1 connector (2U
2022-11-11 154
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
(J102) FAN1/J67)
43 Left mounting ear connector 44 LP slimline 4 connector
(LCIA BOARD/J106) (SLIMLINE4/J12)
45 LP slimline 3 connector 46 Power connector for the
(SLIMLINE3/J85) built-in-drive backplane
(INNER HDD PWR/J22)
47 Drive backplane power 48 BBU power connector (BBU
connector 2 (HDD BP POWER/J13001)
PWR2/J88)
49 Drive backplane power 50 Rear-drive backplane power
connector 1 (HDD BP connector 3 (REAR BP
PWR1/J26) PWR3/J20)
51 PSU 2 connector (PSU2/J56) 52 LP slimline 5 connector
(SLIMLINE5/J30)
53 Low-speed signal connector 54 Low-speed signal connector
for the built-in-drive for the rear 4 x 2.5" drive
backplane (INNER HDD backplane (REAR 4x2.5
BP/J27) HDD BP/J57)
55 PSU 1 connector (PSU1/J28) - -
⚫ Use connectors 34, 36, 40, and 42 when the 8038+ fan modules are configured.
⚫ Use connectors 33, 34, 35, 36, 38, 40, 41, and 42 when the 8080 fan modules are
configured.
2022-11-11 155
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 156
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 157
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 158
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 159
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 160
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 161
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 162
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 163
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Built-in-Drive Backplane
⚫ 4 x 3.5" drive backplane
2022-11-11 164
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Rear-drive backplane
⚫ 2 x 2.5" drive backplane
2022-11-11 165
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 166
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Server with 8 x 2.5" drives has two types of front panels. The front panels appearance Figure 5-132 of
the chassis delivered on or before June 30, 2022 is shown in Figure 1. The front panels appearance
Figure 5-133 of the chassis delivered after June 30, 2022 is shown in Figure 2.
2022-11-11 167
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 168
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Server with 8 x 2.5" drives has two types of front panels. The indicators and buttons on the front panels
Figure 5-137 of the chassis delivered on or before June 30, 2022 are shown in Figure 1. The indicators
and buttons on the front panels Figure 5-138 of the chassis delivered after June 30, 2022 are shown in
Figure 2.
2022-11-11 169
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 170
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 171
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 172
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Indicator Positions
Indicator Description
2022-11-11 173
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.2.3 Interface
Port Positions
2022-11-11 174
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Port Description
2022-11-11 175
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.3 Processor
⚫ The server supports one or two processors.
⚫ If only one processor is required, install it in socket CPU1.
⚫ Processors of the same model must be used in a server.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility
Checker to determine the components to be used.
2022-11-11 176
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.4 Memory
5.2.4.1 DDR4 Memory
5.2.4.1.1 Memory ID
You can determine the memory module properties based on the label attached to the memory
module.
1 Capacity ⚫ 16 GB
⚫ 32 GB
⚫ 64 GB
⚫ 128 GB
2 rank(s) ⚫ 1R = Single rank
⚫ 2R = Dual rank
⚫ 4R = Quad rank
⚫ 8R = Octal rank
3 Data width on the DRAM ⚫ x4: 4-bit
⚫ x8: 8-bit
4 Type of the memory interface ⚫ PC4 = DDR4
5 Maximum memory speed ⚫ 2933 MT/S
⚫ 3200 MT/S
6 Column Access Strobe (CAS) ⚫ W=CAS 20-20-20
latency ⚫ Y=CAS 21-21-21
⚫ AA=CAS 22-22-22
7 DIMM type ⚫ R = RDIMM
⚫ L = LRDIMM
2022-11-11 177
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
CPU 1 A DIMM000(A)
B DIMM010(B)
C DIMM020(C)
D DIMM030(D)
E DIMM040(E)
F DIMM050(F)
G DIMM060(G)
H DIMM070(H)
CPU 2 A DIMM100(A)
B DIMM110(B)
C DIMM120(C)
D DIMM130(D)
E DIMM140(E)
F DIMM150(F)
G DIMM160(G)
H DIMM170(H)
2022-11-11 178
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ A server must use DDR4 memory modules of the same part number (P/N code), and the
memory speed is the minimum value of the following items:
⚫ Memory speed supported by a CPU
⚫ Maximum operating speed of a memory module
⚫ The DDR4 DIMMs of different types (RDIMM and LRDIMM) and specifications
(capacity, bit width, rank, and height) cannot be used together.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker
to determine the components to be used.
⚫ The memory can be used with the third-generation Intel® Xeon® Scalable Ice Lake
processors. The maximum memory capacity supported by all processor models is the
same.
⚫ The total memory capacity is the sum of the capacity of all DDR4 memory modules.
⚫ For details about the capacity type of a single memory module, see "Search Parts" in the
Compatibility Checker.
⚫ The maximum number of memory modules supported depends on the memory type and
rank quantity.
Each memory channel supports a maximum of 8 ranks. The number of memory modules supported by
each channel varies depending on the number of ranks supported by each channel:
Number of memory modules supported by each channel ≤ Number of ranks supported by each memory
channel/Number of ranks supported by each memory module
Parameter Specifications
2022-11-11 179
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
At least one DDR4 memory module must be installed in the primary memory channels
corresponding to CPU 1.
2022-11-11 180
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 181
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 182
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.5 Storage
5.2.5.1 Drive Configurations
5.2.5.1.1 8 x 2.5" drive pass-through configuration
Drive configuration
2022-11-11 183
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 1 in Table 5-65
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
44 44
45 45
46 46
47 47
⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 2 and 8 x 2.5" drive
pass-through configuration 3 in Table 5-65
2022-11-11 184
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
44 44 -
45 45 -
46 46 -
47 47 -
Drive configuration
2022-11-11 185
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 8 x 3.5" drive pass-through configuration 1 and 8 x 3.5" drive
pass-through configuration 2 in Table 5-68
2022-11-11 186
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 187
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Drive configuration
2022-11-11 188
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 189
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 190
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 1 in Table 5-70
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
40 40
41 41
44 44
45 45
46 46
47 47
2022-11-11 191
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 2 and 12 x 3.5" drive
pass-through configuration 3 in Table 5-70
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
44 44 -
45 45 -
46 46 -
2022-11-11 192
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
47 47 -
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 0
41 41 1
2022-11-11 193
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
44 44 -
45 45 -
46 46 -
47 47 -
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
2022-11-11 194
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
11 11
40 40
41 41
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8Note
9 9 9Note
10 10 10Note
11 11 11Note
2022-11-11 195
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
40 40 12
41 41 13
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
Drive configuration
2022-11-11 196
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 197
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 198
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 1 and 12 x 3.5" drive EXP
configuration 2 in Table 5-76
0 0 0
1 1 1
2022-11-11 199
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
44 44 -
45 45 -
46 46 -
47 47 -
⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 3 and 12 x 3.5" drive EXP
configuration 4 in Table 5-76
2022-11-11 200
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 201
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
36 36 8
37 37 9
38 38 10
39 39 11
40 40 12
41 41 13
44 44 12Note
45 45 13Note
46 46 14Note
47 47 15Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate RAID controller card numbers are displayed, identify the RAID controller
cards based on the EID.
⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 5 (dual RAID controller cards)
in Table 5-76
2022-11-11 202
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 0
41 41 1
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 203
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
40 40 12
41 41 13
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 204
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
2022-11-11 205
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
9 9 9
10 10 10
11 11 11
36 36 8
37 37 9
38 38 10
39 39 11
40 40 12
41 41 13
44 44 12Note
45 45 13Note
46 46 14Note
47 47 15Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate RAID controller card numbers are displayed, identify the RAID controller
cards based on the EID.
Drive configuration
2022-11-11 206
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 207
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 208
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
Slot numbers
⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 1 and 25 x 2.5" drive EXP
configuration 2 in Table 5-82
0 0 0
2022-11-11 209
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 210
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 3 and 25 x 2.5" drive EXP
configuration 4 in Table 5-82
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
2022-11-11 211
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 8Note
45 45 9Note
46 46 10Note
47 47 11Note
⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can
manage the drive and allocate a number to the drive.
⚫ If duplicate RAID controller card numbers are displayed, identify the RAID controller
cards based on the EID.
⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 5 (dual RAID controller cards)
in Table 5-82
2022-11-11 212
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 0
41 41 1
44 44 -
45 45 -
2022-11-11 213
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
46 46 -
47 47 -
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
2022-11-11 214
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
13 13 13
14 14 14
15 15 15
16 16 16
17 17 17
18 18 18
19 19 19
20 20 20
21 21 21
22 22 22
23 23 23
24 24 24
40 40 25
41 41 26
44 44 -
45 45 -
46 46 -
47 47 -
2022-11-11 215
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives
support surprise hot swap.
2022-11-11 216
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ If the VMD function is disabled, NVMe drives support only orderly hot swap.
2022-11-11 217
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.6 Network
5.2.6.1 OCP 3.0 Network Adapters
OCP 3.0 network adapters provide network expansion capabilities.
⚫ The FlexIO slot supports the OCP 3.0 network adapter, which can be configured as
required.
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility
Checker to determine the components to be used.
⚫ For details about the OCP 3.0 network adapter, see the documents of each OCP 3.0
network adapter.
2022-11-11 218
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
PCIe Slots
⚫ I/O module 3 provides slots 5 and 6. If a one-slot PCIe riser module is used, slot 5 is
unavailable.
⚫ The mainboard provides PCIe slots 1, 2, 3, and 4, and a built-in PCIe slot.
2022-11-11 219
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 220
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 221
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.8 PSUs
⚫ The server supports one or two PSUs.
⚫ The server supports AC or DC PSUs.
⚫ The PSUs are hot-swappable.
⚫ The server supports two PSUs in 1+1 redundancy.
⚫ PSUs of the same P/N code must be used in a server.
⚫ The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs
with dual input live wires.
⚫ If the DC power supply is used, purchase the DC power supply that meets the
requirements of the safety standards or the DC power supply that has passed the CCC
certification.
2022-11-11 222
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
⚫ Contact your local sales representative or see "Search Parts" in the Compatibility
Checker to determine the components to be used.
2022-11-11 223
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.10 LCD
Function
The LCD displays the installation status and running status of server components and enables
users to set the IP address of the iBMC management network port on the server.
The LCD and the server iBMC form an LCD subsystem. The LCD directly obtains device
information from the iBMC. The LCD subsystem does not store device data.
2022-11-11 224
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
UI
Tab Function
For details about how to use the LCD module, see FusionServer Rack Server LCD User
Guide.
2022-11-11 225
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
5.2.11 Board
5.2.11.1 Mainboard
2022-11-11 226
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 227
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 228
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 229
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 230
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 231
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
All drive configurations in 5.2.5.1.5 25 x 2.5" drive EXP configuration support this
backplane.
Built-in-Drive Backplane
⚫ 4 x 3.5" drive backplane
Rear-drive backplane
⚫ 2 x 3.5" drive backplane
2022-11-11 232
FusionServer 2288H V6 Server
Technical White Paper 5 Hardware Description
2022-11-11 233
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
6 Product Specifications
2022-11-11 234
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
− RDIMM and LRDIMM support
− Max. 3200 MT/s memory speed
− The DDR4 memory modules of different types
(RDIMM and LRDIMM) and specifications (capacity,
bit width, rank, and height) cannot be used together.
− A server must use DDR4 memory modules of the same
P/N code.
⚫ Up to 16 PMem modules
− The PMem modules must be used with the DDR4
memory modules, and only one PMem module can be
installed in each memory channel.
− The PMem modules support the AD or MM mode.
− Max. 3200 MT/s memory speed
− The PMem modules of different specifications (capacity
and rank) cannot be used together.
− For details about the PMem modules, see FusionServer
PMem 200 User Guide.
NOTE
The preceding information is for reference only. For details, see
"Search Parts" in the Compatibility Checker.
2022-11-11 235
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
⚫ Supports hot swap of SAS/SATA/NVMe U.2 drives.
NOTE
The NVMe drives support:
⚫ Before using the VMD function, contact technical support
engineers of the OS vendor to check whether the OS supports the
VMD function. If yes, check whether the VMD driver needs to be
manually installed and check the installation method.
⚫ Surprise hot swap if the VMD function is enabled and the latest
Intel VMD driver is installed.
⚫ Orderly hot swap if the VMD function is disabled.
⚫ Supports a variety of RAID controller cards. For details,
see "Search Parts" in the Compatibility Checker.
− The RAID controller card supports RAID configuration,
RAID level migration, and drive roaming.
− The RAID controller card supports a supercapacitor for
power-off protection to ensure user data security.
− The PCIe RAID controller card occupies one PCIe slot.
− The RAID controller card supports Intel VROC (VMD
NVMe RAID) for RAID management. Different VROC
keys can be configured to support different RAID
levels.
For details about the RAID controller card, see V6 Server
RAID Controller Card User Guide.
NOTE
If the BIOS is in legacy mode, the 4K drive cannot be used as the boot
drive.
2022-11-11 236
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
⚫ Server model with 11 standard PCIe cards installed on the
rear panel: one PCIe slot dedicated for a screw-in RAID
controller card, two FlexIO slots dedicated for OCP 3.0
network adapters, and 11 slots for standard PCIe cards.
For details, see 5.1.7.2 PCIe Slots and 5.1.7.3 PCIe Slot
Description.
NOTE
The preceding information is for reference only. For details, see
"Search Parts" in the Compatibility Checker.
2022-11-11 237
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
⚫ Secure boot
⚫ Front bezel (optional)
⚫ Chassis cover opening detection
Category Specifications
2022-11-11 238
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Specifications
Acoustic noise The declared A-weighted sound power levels (LWAd) and
declared average bystander position A-weighted sound
pressure levels (LpAm) listed are measured at 23°C (73.4°F) in
accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
⚫ Idle:
− LWAd: 5.73 Bels
− LpAm: 40.2 dBA
⚫ Operating:
− LWAd: 6.62 Bels
− LpAm: 49.1 dBA
NOTE
Actual sound levels generated during server operation vary depending
on server configuration, load, and ambient temperature.
SSDs and HDDs (including NL-SAS, SAS, and SATA) cannot be preserved for a long time in the
power-off state. Data may be lost or faults may occur if the preservation duration exceeds the specified
maximum duration. When drives are preserved under the storage temperature and humidity specified in
the preceding table, the following preservation time is recommended:
⚫ Maximum preservation duration of SSDs:
⚫ 12 months in power-off state without data stored
⚫ 3 months in power-off state with data stored
⚫ Maximum preservation duration of HDDs:
⚫ 6 months in unpacked/packed and powered-off state
⚫ The maximum preservation duration is determined according to the preservation specifications
provided by drive vendors. For details, see the manuals provided by drive vendors.
2022-11-11 239
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Description
NOTE
⚫ See Figure 6-1 for methods in measuring physical dimensions of
the chassis.
⚫ Methods measuring chassis with 3.5" and 2.5" drives are the same.
The 3.5" drive chassis is used as an example.
2022-11-11 240
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Description
Component Specifications
2022-11-11 241
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
⚫ Max. 270 W TDP
NOTE
The preceding information is for reference only. For details, see
"Search Parts" in the Compatibility Checker.
2022-11-11 242
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
Intel VMD driver is installed.
⚫ Orderly hot swap if the VMD function is disabled.
⚫ Supports a variety of RAID controller cards. For details,
see "Search Parts" in the Compatibility Checker.
− The RAID controller card supports RAID configuration,
RAID level migration, and drive roaming.
− The RAID controller card supports a supercapacitor for
power-off protection to ensure user data security.
− The PCIe RAID controller card occupies one PCIe slot.
For details about the RAID controller card, see V6 Server
RAID Controller Card User Guide.
NOTE
If the BIOS is in legacy mode, the 4K drive cannot be used as the boot
drive.
2022-11-11 243
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Component Specifications
NOTE
You are not advised to install the operating system on the USB storage
media.
Category Specifications
2022-11-11 244
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Specifications
⚫ Storage humidity (within six months): 8% to 80%
⚫ Storage humidity (within one year): 20% to 75%
⚫ Maximum humidity change rate: 20%/h
Air volume ≥204 CFM
Operating altitude ≤ 3050 m (10006.44 ft)
⚫ When the server configuration complies with ASHRAE
Classes A1 and A2 and the altitude is above 900 m
(2952.76 ft), the highest operating temperature decreases by
1°C (1.8°F) for every increase of 300 m (984.24 ft).
⚫ When the server configuration complies with ASHRAE
Class A3 and the altitude is above 900 m (2952.76 ft), the
highest operating temperature decreases by 1°C (1.8°F) for
every increase of 175 m (574.14 ft).
⚫ When the server configuration complies with ASHRAE
Class A4 and the altitude is above 900 m (2952.76 ft), the
highest operating temperature decreases by 1°C (1.8°F) for
every increase of 125 m (410.1 ft).
⚫ HDDs cannot be used at an altitude of over 3050 m
(10006.44 ft).
Corrosive gaseous Maximum corrosion product thickness growth rate:
contaminant ⚫ Copper corrosion rate test: 300 Å/month (meeting level G1
requirements of the ANSI/ISA-71.04-2013 standard on
gaseous corrosion)
⚫ Silver corrosion rate test: 200 Å/month
Particle contaminant ⚫ The equipment room environment meets the requirements
of ISO 14664-1 Class 8.
⚫ There is no explosive, conductive, magnetic, or corrosive
dust in the equipment room.
NOTE
It is recommended that the particulate pollutants in the equipment room
be monitored by a professional organization.
Acoustic noise The declared A-weighted sound power levels (LWAd) and
declared average bystander position A-weighted sound
pressure levels (LpAm) listed are measured at 23°C (73.4°F) in
accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
⚫ Idle:
− LWAd: 5.98 Bels
− LpAm: 42.6 dBA
⚫ Running:
− LWAd: 6.68 Bels
− LpAm: 49.5 dBA
NOTE
Actual sound levels generated during server operation vary depending
2022-11-11 245
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Specifications
on server configuration, load, and ambient temperature.
SSDs and HDDs (including NL-SAS, SAS, and SATA) cannot be preserved for a long time in the
power-off state. Data may be lost or faults may occur if the preservation duration exceeds the specified
maximum duration. When drives are preserved under the storage temperature and humidity specified in
the preceding table, the following preservation time is recommended:
⚫ Maximum preservation duration of SSDs:
⚫ 12 months in power-off state without data stored
⚫ 3 months in power-off state with data stored
⚫ Maximum preservation duration of HDDs:
⚫ 6 months in unpacked/packed and powered-off state
⚫ The maximum preservation duration is determined according to the preservation specifications
provided by drive vendors. For details, see the manuals provided by drive vendors.
Category Description
NOTE
⚫ See Figure 6-2 for methods in measuring physical dimensions of
the chassis.
⚫ Methods measuring chassis with 3.5" and 2.5" drive are the same.
2022-11-11 246
FusionServer 2288H V6 Server
Technical White Paper 6 Product Specifications
Category Description
The 3.5" drive chassis is used as an example.
2022-11-11 247
FusionServer 2288H V6 Server
Technical White Paper 7 Software and Hardware Compatibility
Use the Compatibility Checker to obtain information about the operating systems and
hardware supported.
⚫ If incompatible components are used, the device may be abnormal. This fault is beyond
the scope of technical support and warranty.
⚫ The performance of servers is closely related to application software, basic middleware
software, and hardware. The slight differences of the application software, middleware
basic software, and hardware may cause performance inconsistency between the
application layer and test software layer.
⚫ If the customer has requirements on the performance of specific application software,
contact technical support to apply for POC tests in the pre-sales phase to determine
detailed software and hardware configurations.
⚫ If the customer has requirements on hardware performance consistency, specify the
specific configuration requirements (for example, specific drive models, RAID controller
cards, or firmware versions) in the pre-sales phase.
2022-11-11 248
FusionServer 2288H V6 Server
Technical White Paper 8 Safety Instructions
8 Safety Instructions
8.1 Security
8.2 Maintenance and Warranty
8.1 Security
General Statement
⚫ Comply with local laws and regulations when installing devices. These Safety
Instructions are only a supplement.
⚫ The "DANGER", "WARNING", and "CAUTION" information in this document does
not represent all the safety instructions, but supplements to the safety instructions.
⚫ Observe all safety instructions provided on the device labels when installing hardware.
Follow them in conjunction with these Safety Instructions.
⚫ Only qualified personnel are allowed to perform special tasks, such as performing
high-voltage operations and driving a forklift.
If this device works in a residential environment, the wireless interference may be generated.
Personal Safety
⚫ This equipment is not suitable for use in places where children may be present.
⚫ Only personnel certified or authorized are allowed to install equipment.
⚫ Discontinue any dangerous operations and take protective measures. Report anything
that could cause personal injury or device damage to a project supervisor.
⚫ Do not move devices or install racks and power cables in hazardous weather conditions.
⚫ Do not carry the weight that is over the maximum load per person allowed by local laws
or regulations. Before moving or installing equipment, check the maximum equipment
weight and arrange required personnel.
⚫ Wear clean protective gloves, ESD clothing, a protective hat, and protective shoes, as
shown in Figure 8-1.
2022-11-11 249
FusionServer 2288H V6 Server
Technical White Paper 8 Safety Instructions
⚫ Before touching a device, wear ESD clothing and gloves (or wrist strap), and remove any
conductive objects (such as watches and jewelry). Figure 8-2 shows conductive objects
that must be removed before you touch a device.
2022-11-11 250
FusionServer 2288H V6 Server
Technical White Paper 8 Safety Instructions
Device Security
⚫ Use the recommended power cables at all times.
⚫ Use power cables only for dedicated servers. Do not use them for other devices.
⚫ Before operating equipment, wear ESD clothes and gloves to prevent
electrostatic-sensitive devices from being damaged by ESD.
⚫ When moving a device, hold the bottom of the device. Do not hold the handles of the
installed modules, such as the PSUs, fan modules, drives, and the mainboard. Handle the
equipment with care.
⚫ Exercise caution when using tools.
⚫ Connect the primary and secondary power cables to different power distribution units
(PDUs) to ensure reliable system operation.
⚫ Ground a device before powering it on. Otherwise, high leakage current may cause
device damage.
Transportation Precautions
Improper transportation may damage equipment. Contact the manufacturer for precautions
before attempting transportation.
Transportation precautions include but are not limited to:
⚫ The logistics company engaged to transport the device must be reliable and comply with
international standards for transporting electronics. Ensure that the equipment being
transported is always kept upright. Take necessary precautions to prevent collisions,
corrosion, package damage, damp conditions and pollution.
2022-11-11 251
FusionServer 2288H V6 Server
Technical White Paper 8 Safety Instructions
For details about the components supported by the server, see "Compatibility" in the Compatibility
Checker.
⚫ Power off all devices before transportation.
Comply with local regulations for the maximum load per person.
Table 8-1 lists the maximum weight one person is permitted to carry as stipulated by a
number of organizations.
For more information about safety instructions, see Server Safety Information.
2022-11-11 252
FusionServer 2288H V6 Server
Technical White Paper 9 System Management
9 System Management
2022-11-11 253
FusionServer 2288H V6 Server
Technical White Paper 9 System Management
2022-11-11 254
FusionServer 2288H V6 Server
Technical White Paper 10 Certifications
10 Certifications
2022-11-11 255
FusionServer 2288H V6 Server
Technical White Paper 10 Certifications
2022-11-11 256
FusionServer 2288H V6 Server
Technical White Paper A Appendix
A Appendix
The label information and location are for reference only. For details, see the actual product.
1 Nameplate 2 Certificate
3 Quick access tag 4 SN
NOTE
For details, see A.2 Product SN.
2022-11-11 257
FusionServer 2288H V6 Server
Technical White Paper A Appendix
device.
A.1.1.1 Nameplate
1 Server Model
For details, see A.4 Nameplate.
2 Device names
3 Power Supply Requirements
4 Vendor Information
5 Authentication ID
A.1.1.2 Certificate
2022-11-11 258
FusionServer 2288H V6 Server
Technical White Paper A Appendix
No. Description
1 Order
2 No.
NOTE
For details, see Figure A-4 and Table A-3.
3 QC inspector
4 Production date
5 No. Barcode
No. Description
1 "P", fixed
2 "Z", fixed
3 ⚫ Y: Server
⚫ B: Semi-finished product of the whole machine.
⚫ N: Loose spare parts
4 "0", Reserved bit.
5 Year (2 digits).
6 Month (1 digit).
⚫ Digits 1 to 9 indicate January to September, respectively.
⚫ Letters A to C indicate October to December, respectively.
7 Day (1 digit).
⚫ Digits 1 to 9 indicate the 1st to 9th
⚫ Letters A to H indicate the 10th to 17th.
⚫ Letters J to N indicate the 18th to 22nd.
⚫ Letters P to Y indicate the 23rd to 31st
8 Hour (1 digit).
⚫ Digits 0 to 9 indicate 0 to 9:00.
2022-11-11 259
FusionServer 2288H V6 Server
Technical White Paper A Appendix
No. Description
⚫ Letters A to H indicate 10 to 17:00.
⚫ Letters J to N indicate 18 to 22:00.
⚫ Letters P to Q indicate 23 to 24:00.
9 Serial number (2 digits)
10 Manufacturing serial number (5 digits).
No. Description
2022-11-11 260
FusionServer 2288H V6 Server
Technical White Paper A Appendix
For details about the warning label, see Server Safety Information.
⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the
mainboard components, important components of the chassis, precautions, and QR codes of
technical resources. The pictures are for reference only. For details, see the actual product.
⚫ The quick guide is optional. For details, see the actual product.
A.2 Product SN
The serial number (SN) on the slide-out label plate uniquely identifies a device. The SN is
required when you contact technical support.
2022-11-11 261
FusionServer 2288H V6 Server
Technical White Paper A Appendix
No. Description
2022-11-11 262
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 263
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 264
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 265
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 266
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 267
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 268
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 269
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 270
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 271
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 272
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 273
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 274
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 275
FusionServer 2288H V6 Server
Technical White Paper A Appendix
⚫ When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the rated
value.
⚫ When a single fan is faulty, the system performance may be affected.
⚫ When the 6342/6348/8351N/8358/8358P/8360Y/8362/8368/8380 processors are configured, I/O
modules 1, 2, and 3 do not support Tesla T4 GPU cards, and I/O module 3 does not support HDDs.
⚫ In 12 x 3.5" drives pass-through configuration and 12 x 3.5" drives EXP configuration, the processor
TDP is required to be no more than 205 W and the total capacity of DIMMs configured no more than
2048 GB when IO module 3 is configured with 4 x 2.5" NVMe drives module.
⚫ It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve
server energy efficiency.
⚫ 8368Q 38c 270 W 2.6 GHz liquid-cooled processors are not supported.
⚫ When the ring temperature is 50°C (122°F), the CPU heat sink must be configured with a 2 U heat
pipe heat sink.
2022-11-11 276
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 277
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 278
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 279
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 280
FusionServer 2288H V6 Server
Technical White Paper A Appendix
⚫ When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the rated
value.
⚫ When a single fan is faulty, the system performance may be affected.
⚫ When the 6342/6348/8351N/8358/8358P/8360Y/8368/8380 processors are configured, I/O modules
do not support Tesla T4 GPU cards, and I/O module 3 does not support HDDs.
⚫ In 12 x 3.5-inch drives pass-through configuration and 12 x 3.5-inch drives EXP configuration, the
processor TDP is required to be no more than 205 W and the total capacity of DIMMs configured no
more than 2048 GB when IO module 3 is configured with 4 x 2.5-inch NVMe drives module.
⚫ It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve
server energy efficiency.
⚫ 8368Q 38c 270 W 2.6 GHz liquid-cooled processors are not supported.
A.4 Nameplate
Certified Model Usage Restrictions
H22H-06 Global
2022-11-11 281
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 282
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 283
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 284
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 285
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 286
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 287
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 288
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 289
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 290
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 291
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 292
FusionServer 2288H V6 Server
Technical White Paper A Appendix
2022-11-11 293
FusionServer 2288H V6 Server
Technical White Paper B Glossary
B Glossary
B.1 A-E
B
BMC The baseboard management controller (BMC) complies with
the Intelligent Platform Management Interface (IPMI). It
collects, processes, and stores sensor signals, and monitors the
operating status of components. The BMC provides the
hardware status and alarm information about the managed
objects to the upper-level management system, so that the
management system can manage the objects.
E
ejector lever A part on the panel of a device used to facilitate installation or
removal of the device.
Ethernet A baseband local area network (LAN) architecture developed
by Xerox Corporation by partnering with Intel and DEC.
Ethernet uses the Carrier Sense Multiple Access/Collision
Detection (CSMA/CD) access method and allows data transfer
over various cables at 10 Mbit/s. The Ethernet specification is
the basis for the IEEE 802.3 standard.
B.2 F-J
G
Gigabit Ethernet (GE) An extension and enhancement of traditional shared media
Ethernet standards. It is compatible with 10 Mbit/s and 100
Mbit/s Ethernet and complies with IEEE 802.3z standards.
2022-11-11 294
FusionServer 2288H V6 Server
Technical White Paper B Glossary
H
hot swap Replacing or adding components without stopping or shutting
down the system.
B.3 K-O
K
KVM A hardware device that provides public video, keyboard and
mouse (KVM).
B.4 P-T
P
panel An external component (including but not limited to ejector
levers, indicators, and ports) on the front or rear of the server.
It seals the front and rear of the chassis to ensure optimal
ventilation and electromagnetic compatibility (EMC).
Peripheral A computer bus PCI, which uses the existing PCI
Component programming concepts and communication standards, but
Interconnect Express builds a faster serial communication system. Intel is the main
(PCIe) sponsor for PCIe. PCIe is used only for internal
interconnection. A PCI system can be transformed to a PCIe
system by modifying the physical layer instead of software.
PCIe delivers a faster speed and can replace almost all AGP
and PCI buses.
R
redundancy A mechanism that allows a backup device to automatically
take over services from a faulty device to ensure uninterrupted
running of the system.
redundant array of A storage technology that combines multiple physical drives
independent disks into a logical unit for the purposes of data redundancy and
(RAID) performance improvement.
S
server A special computer that provides services for clients over a
network.
2022-11-11 295
FusionServer 2288H V6 Server
Technical White Paper B Glossary
system event log Event records stored in the system used for subsequent fault
(SEL) diagnosis and system recovery.
B.5 U-Z
U
U A unit defined in International Electrotechnical Commission
(IEC) 60297-1 to measure the height of a cabinet, chassis, or
subrack. 1 U = 44.45 mm
UltraPath A point-to-point processor interconnect developed by Intel.
Interconnect (UPI)
2022-11-11 296
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
C.1 A-E
A
AC alternating current
B
BBU backup battery unit
C
CCC China Compulsory Certification
CD calendar day
CE Conformite Europeenne
2022-11-11 297
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
D
DC direct current
E
ECC error checking and correcting
EID Enclosure ID
EN European Efficiency
C.2 F-J
F
FB-DIMM Fully Buffered DIMM
FC Fiber Channel
G
GE Gigabit Ethernet
2022-11-11 298
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
H
HA high availability
I
iBMC intelligent baseboard management controller
IC Industry Canada
IP Internet Protocol
C.3 K-O
K
KVM keyboard, video, and mouse
2022-11-11 299
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
L
LC Lucent Connector
M
MAC media access control
N
NBD next business day
O
OCP Open Compute Project
C.4 P-T
P
PCIe Peripheral Component Interconnect Express
POK Power OK
2022-11-11 300
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
R
RAID redundant array of independent disks
S
SAS Serial Attached Small Computer System Interface
SERDES serializer/deserializer
T
TACH tachometer signal
2022-11-11 301
FusionServer 2288H V6 Server
Technical White Paper C Acronyms and Abbreviations
C.5 U-Z
U
UDIMM unbuffered dual in-line memory module
V
VCCI Voluntary Control Council for Interference by Information
Technology Equipment
VGA Video Graphics Array
W
WEEE waste electrical and electronic equipment
2022-11-11 302