TLB Modbus TCP Digital Amplifier en PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

TLB

Digital / Analog weight Transmitter RS485

TLB
Digital / Analog weight Transmitter RS485

DESCRIPTION

 Weight transmittersuitable for back panel mounting on Omega/DIN rail.


 Space-saving vertical shape.
 Dimensions: 25x115x120 mm.
 6-digit semi-alphanumeric red LED display (8 mm height).
 6 signalling LED.
 Four buttons for the system calibration.
 Extractable screw terminal blocks.

INPUTS/OUTPUTS AND COMMUNICATION

 RS485 serial port for communication via protocols ModBus RTU,


ASCII Laumas bidirectional or continuous one way transmission.
 3 relay outputs controlled by the setpoint values or via protocols.
 2 optoisolated PNP d igital i nputs: status reading v ia s erial
communication protocols.
 1 load cell dedicated input.

FIELDBUSESBUSES
Version   02.2020

Page  1 / 4
TLB
Digital / Analog weight Transmitter RS485

DESCRIPTION CODE

RS485 serial port.


TLB485
Baud rate: 2400, 4800, 9600, 19200, 38400, 115200 (bit/s).

Optoisolated 16 bit analog output.


Current: 0÷20 mA; 4÷20 mA (up to 300 ).
TLB
Voltage: 0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 k ).
Equipped with RS485 serial port.

CANopen port.
Baud rate: 10, 20, 25, 50, 100, 125, 250, 500, 800, 1000 (kbit/s).
TLBCANOPEN
The instrument works as s lave in a synchronous CANopen network.
Equipped with RS485 serial port.

DeviceNet port.
Baud rate: 125, 250, 500 (kbit/s).
TLBDEVICENET
The instrument works as s lave i n a DeviceNet network.
Equipped with RS485 serial port.

CC-Link port.
Baud rate: 156, 625, 2500, 5000, 10000 (kbit/s).
TLBCCLINK
The instrument works as Remote Device Station in a CC-Link network and
occupies 3 stations. Equipped with RS485 serial port.

PROFIBUS DP port.
Baud rate: up to 12 Mbit/s.
TLBPROFI
The instrument works as s lave i n a Profibus-DP network.
Equipped with RS485 serial port.

Modbus/TCP port.
Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBMODBUSTCP
The instrument works as s lave in a Modbus/TCP network.
Equipped with RS485 serial port.

Ethernet TCP/IP port.


Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBETHETCP
The instrument works in an Ethernet TCP/IP network and it is accessible via
web browser. Equipped with RS485 serial port.

2x Ethernet/IP ports.
Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBETHEIP
The instrument works as adapter in an Ethernet/IP network.
Equipped with RS485 serial port.

2x PROFINET IO ports.
Type: RJ45 100Base-TX.
TLBPROFINETIO
The instrument works as device in a Profinet IO network.
Equipped with RS485 serial port.

2x EtherCAT ports.
Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBETHERCAT
The instrument works as s lave i n an EtherCAT network.
Equipped with RS485 serial port.

2x POWERLINK ports.
Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBPOWERLINK
The instrument works as s lave i n a Powerlink network.
Equipped with RS485 serial port.

2x SERCOS III ports.


Type: RJ45 10Base-T or 100Base-TX (auto-sensing).
TLBSERCOS
The instrument works as s lave in a Sercos III network.
Version   02.2020

Equipped with RS485 serial port.

Page  2 / 4
TLB
Digital / Analog weight Transmitter RS485

CERTIFICATIONS

TECHNICAL FEATURES

Version   02.2020

Page  3 / 4
TLB
Digital / Analog weight Transmitter RS485

MAIN FUNCTIONS

Version   02.2020

Page  4 / 4

The information provided herein is to the best of our knowledge true and accurate, it is provided for guidance only. All specifications are subject to change without prior notification.
Althen – Your expert partner in Sensors & Controls | althensensors.com
Althen stands for pioneering measurement and custom sensor solutions. In addition we offer services such as calibration, design & engineering, training and renting of measurement equipment.
Germany/Austria/Switzerland Benelux France Sweden USA/Canada Other countries
[email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

You might also like