Bipigard Coaltar Finish

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

TUFFKOTE

PROTECTIVE COATINGS
BIPIGARD COALTAR FINISH
Data Sheet No. SPL/PMG/2019100071

A two component polyamine cured high build coal tar epoxy paint giving very good toughness and water resistance. The
product performs extremely well in total, partial or intermittent immersion in salt or fresh water. It withstands corrosive
conditions in soil immersion and also certain acidic and alkaline environments.

Product Information Surface Preparation


Steel Surface
Color Black Surface must be clean, dry & free from
contamination. Prior to paint application all
Finish Smooth & Semi-glossy surfaces should be assessed and treated in
accordance with ISO 8504:2000. Abrasive blast
Flash Point Above 23 C
clean to SA 2½ is recommended. If Abrasive blast
Mixing Ratio Base : Accelerator cleaning is not possible it is recommended to
(By Volume) 9:1 hand tool/ power tool cleaning up St2 or St3
before application of this this product.
Volume Solids 70 ± 3 % Concrete Substrate
Ensure that the surface is cured for minimum 28
Recommended dry Days. Remove laitance, loose surface powder by
75 - 100 microns
film thickness light sand blasting. If blast cleaning is not feasible,
roughen the surface by acid etching with 10%
Corresponding wet Hydrochloric Acid solution followed by thorough
107 - 142 microns
film thickness freshwater hosing to remove any residual acid.
The surface should be perfectly dry and clean
Theoretical before applying this coat.
9.33 – 7.0 Sq.metre /litre
Spreading Rate
For damage area rectification please contact the
Surface dry 5 -10 hours Technical team of Shalimar Paints Limited.
Handle dry 24 hours
Drying time @ 30°C
Hard dry 24 - 48 hours Application Details
Full curing 7 days Method of Application
Brush / Roller / Airless Spray
Interval before Over- Minimum 24 hours Notes on Airless Spray
coating Maximum 7 days
Tip Range 21 – 29 thou.
Total Output 2500-3000 psi.
Volatile organic Fluid Pressure (210 kg/sq.cm.)
Compound (VOC) 250 gm/ltr (EPA Method 24) Pot Life 6 - 8 hours
12 months minimum @ 30°C if Thinner Thinner 6756
stored in a dry sealed
Storage Life container at shaded condition Uses
away from heat source and
ignition For use as topcoat in Sluice gate, Barrage Gates,
Pipes, Penstocks, Storage Tank, Structural Works
Dry Heat in Power Plants, Fertilizer Plants, Chemical
Up to 120C (Intermittent)
Resistance Factories and Concrete bridges etc

1
BIPIGARD COALTAR FINISH

SURFACE 1ST COAT


Typical System Selection
2ND COAT 3RD COAT 4TH COAT

Epigard Epoxy Zinc Rich


Bipigard Coaltar Bipigard Coaltar
Steel Primer/ Epigard Zinc -
Finish Finish
Rich / Epigard HB ZP
Primer
Epiplus Superbuild ST Bipigard Coaltar Bipigard Coaltar
- Do - -
Coating Finish Finish

Epigard HP Off White


Concrete Bipigard Coaltar Bipigard Coaltar
Primer / Bipigard -
Surface Finish Finish
Coaltar Finish

Chemical Resistance Guide (with suitable top


coat)
EXPOSURE Acids Alkalis Solvents Salt Water
SPLASH & SPILLAGE Good Excellent Good Excellent Excellent
FUMES & OUTDOOR EXPOSURE Good Excellent Very Good Excellent Excellent

Health & Safety


Use Proper Personal Protective Equipment(PPE) during application of this product.

Please consult Material Safety Datasheet (MSDS)

Precaution
Provide adequate ventilation during application and drying. Clean Spray gun equipment and hose immediately
after application of material.

Standard Pack Size


10 & 20 litres - For available pack size contact local representative of Shalimar Paints Limited

NOTES:
1. This Product datasheet supersedes all previous datasheet and subject to change without prior notice
2. Do not apply when surface temperature is less than 3C than dew point.
3. Mixing with mechanical agitator is strongly recommended
4. Use material within stipulated potlife
5. Do not apply paints when environment temperature rises above 50 C or when relative humidity rises above 85%. Do not
apply during rain, fog or mist.
6. Use of thinners other than supplied or approved by Shalimar may adversely affect product performance
7. Drying is dependent on temperature, relative humidity and thickness; ranges is given for considering those parameters
8. System Guide is a typical and for indicative purpose only, however this can have wide range of combination. For
details, please contact Shalimar Paints limited
9. Request for details information of surface preparation, paint application on the recommended coating system

DISCLAIMER: This PDS is by no means a comprehensive data. The company will not be liable for losses or damages howsoever caused including liability for
negligence, which may be suffered by the user of the data contained therein. It is the user's responsibility to conduct all necessary tests to confirm the suitability
of any product or system for their intended use. No guarantee of result is extended since conditions of use are beyond our control. Liability is limited to
replacement of the product hence cost of labour charges or consequential damages are excluded.

Rev 2 - 2