Lucknow Airport Status Report
Lucknow Airport Status Report
Basement
7 40
16
1
2
39
32
130
MR 16 IN Port Available To be Used in Ph 1 Remark
96 3 No deviation in BoQ
DEPARTURE LVL ARRIVAL
FLOOR MEZZANINE
FLOOR
Primary System
DEVICE Quantity
DAEP BIOMETRIC READER (BCAS) 18 2
AEP AEP BIO METRICS ACCESS ONE SIDE READER 5 0
AEP AEP AEP BIO METRICS BOTH SIDE READER 10 0
Secondary System
CR SMART CARD READER 39 27
MR52-S3 29 27
LP1501 6 4
MR16 1-IN, 1-OUT 2-IN, 1-OUT
LP1501 2 2
BIO BIOMETRIC READER 0 2
PU PUSH BUTTON 0 0
Other Vender
EL ELECTRIFIED LOCKING DOOR 38 33
DPS DOOR POSTIONING SENSOR 38 33
FE FREE EXIT 19 21
6 8
ARRIVAL FLOOR BASEMENT BASEMENT GROUND No of Mech. Qty as per
PLAN MEZZANINE FLOOR FLOOR PLAN FLOOR PLAN Barriers/Doors survey/map
Primary System
Total Total Device QTY
0 0 0 0 20 20
7 0 0 0 12 12
8 0 0 0 18 36
Secondary System
23 1 8 2 100 100
22 1 8 2 89 89
4 1 2 1 18 18
2-IN, 1-OUT 1-IN, 1-OUT 6-IN, 4-OUT
2 2 8 8
5 0 0 0 7 7
1 0 0 0 1 1
Other Vender
48 1 15 2 137 137
48 1 15 2 137 137
25 1 8 2 76 76
15 7
QUT AS Remark
FOR BOQ
primary
primary
primary
128
86
25
10 secondary
25
Type Qty.
Access Control Management Servers 4
Server / Desktop / Desktop Workstation 18
Printers Multifunction Printers 2
Laser Jet Network Printer 2
Smart Card Biometric Reader cum Controller (Wall Mount) 15
Primary System
13 8 Core Cable 8Core Cable for the Biometric ACS
6900
6900
2100
7205
1200
4000
2450
1900
Basment Arrival
Floor level Mezzanine Arrival Mezzanine Departure
Number of Fire
Egress Door 7 15 8 6
Mapped Fire Egress
Door 5 12 7 5
Number of MR16
IN used 0 3 2 0
Number of MR16
OUT used 0 3 2 0
Site Name Status
Site Pending Partial Site Pending Site Not Found Site Done
Arrival 27 6 5 4
Arrival Mezzanine 19 9 1 1
Departure 44 1 4 4
Basement 3 5
Basement Mezzanine 1
Utility Services Area 2
Total Site 95 22 10 9
Arrival 23 5 1 3
Arrival Mezzanine 28 2 0 0
Departure 39 0 0 10
Basement 8 0 0 0
Basement Mezzanine 1 0 0 0
Utility Services Area 2 0 0 0
Total Site 101 7 1 13
atus
Location Change Total
1 43
0 30
53
8
1
2
1 137
atus
Scosta Biometric Reader Biometric Reader Total
(ONE SIDE- swing Barrier) (BCAS)
9 0 41
0 2 30
5 18 54
0 0 8
0 0 1
0 0 2
14 136
Priority Order Document List
1 Detailed Architecture
2 DCI document
3 Mapping of Interface Requirement Document(IRD)
Airport Campus Network (ACN)
4
Fire Alarm System (FAS)
5
Video Management System (VMS)
6
7 Network Time Protocol Server (NTPS)
8 Airport Operation Control Center (AOCC)
9 Airport Campus Network (ACN)
Access Flap Gate (AFG)
10
11 Fire Alarm System (FAS) HICD
12 Network Time Protocol Server (NTPS)
13 Video Management System (VMS)
14 Airport Operation Control Centre (AOCC)
15 Mapping of ICD Document
Status
2/17/2023 Review
Provided by ICAD
Primary System
1 Desktop Workstation 18
2 RFID Readers (IP65 Rated) 4
4 RFID Encoder 2
Secondary System
1 Access Control Management Servers (Database & Application) 2
m
Site Not Confirmed Yet
Site Not Confirmed Yet
Push to exit switch mounting Location is not
conform, only the conformation is output
connection with Swing Barrier.
Site Not Confirmed Yet
m
Site Not Confirmed Yet
Terminal Management
Office Corridor As per Naveen Sir
24-25/E-F suggestion we have added
two new door conduit
(Departure)